• Title/Summary/Keyword: Harmonic Coefficient

Search Result 174, Processing Time 0.022 seconds

Variation of the Sea Surface Height around the Korean Peninsula with the Use of Multi-satellite Data (Topex/Poseidon, Jason-1, ERS, Envisat) and its Association with Sea Surface Temperature (복합위성자료(Topex/Poseidon, Jason-1, ERS, Envisat)를 이용한 한반도 주변해역에서의 해수면 고도 변화와 해수면 온도의 상관성 연구)

  • Ha, Kyung-Ja;Jeong, Gi-Yong;Jang, Sae-Rom;Kim, Ki-Young
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.6
    • /
    • pp.519-531
    • /
    • 2006
  • Sea surface height (SSH) around fe Korean Peninsula was investigated as a rising rate of $3.89mm\;yr^{-1}$ on the average from 1993 to 2005, which is 1.3 times higher rising rate, compared to the world ocean. In the present study, to investigate SSH changes in regional sections of the East Sea, the Yellow Sea, the South Sea, and the Korea Strait, DT-MSLA (Delayed Time-Maps of Sea Level Anomalies) with multi-satellite data (Topex/Poseidon, Jason-1, ERS, Envisat), provided by AVISO (Archiving, Validation and Interpretation of Satellite Oceanographic data), was used. The periodicity in interannual variability was dominant for $4\sim5$ year in summer, and 3 year in winter as well as an increasing trend. The amplitude and phase for the annual and semi-annual mode in SSH and SST were investigated with harmonic analysis. The geographical distribution of amplitudes for comparison of SSH and SST are slightly reverse in southwest-northeast tilted direction. The monthly SST and SSH is highly correlated correlation coefficient about 0.7 with lag of one or two months over the East Sea and the South Sea during June-August. These results suggest that the Kuroshio stream is dominant during summer over these regions.

Reliability of OperaVOXTM against Multi-Dimensional Voice Program to Assess Voice Quality before and after Laryngeal Microsurgery in Patient with Vocal Polyp (성대 용종 환자의 후두미세수술 전후 음성 평가에서 OperaVOXTM와 Multi-Dimensional Voice Program 간의 신뢰도 연구)

  • Kim, Sun Woo;Kim, So Yean;Cho, Jae Kyung;Jin, Sung Min;Lee, Sang Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.31 no.2
    • /
    • pp.71-77
    • /
    • 2020
  • Background and Objectives OperaVOXTM (Oxford Wave Research Ltd.) is a portable voice analysis software package designed for use with iOS devices. As a relatively cheap, portable and easily accessible form of acoustic analysis, OperaVOXTM may be more clinically useful than laboratory-based software in many situations. The aim of this study was to evaluate the agreement between OperaVOXTM and Multi-Dimensional Voice Program (MDVP; Computerized Speech Lab) to assess voice quality before and after laryngeal microsurgery in patient with vocal polyp. Materials and Method Twenty patients who had undergone laryngeal microsurgery for vocal polyp were enrolled in this study. Preoperative and postoperative voices were assessed by acoustic analysis using MDVP and OperaVOXTM. A five-seconds recording of vowel /a/ was used to measure fundamental frequency (F0), jitter, shimmer and noise-to-harmonic ratio (NHR). Results Several acoustic parameters of MDVP and OperaVOXTM related to short-term variability showed significant improvement. While pre-operative value of F0, jitter, shimmer, NHR was 155.75 Hz (male: 125.37 Hz, female: 183.37 Hz), 2.20%, 6.28%, 0.16, post-operative values of these parameter was 164.34 Hz (male: 129.42 Hz, female: 199.26 Hz), 2.15%, 5.18%, 0.14 Hz in MDVP. While pre-operative value of F0, jitter, shimmer, NHR was 168.26 Hz (male: 135.16 Hz, female: 201.37 Hz), 2.27%, 6.95%, 0.26, post-operative values of these parameters was 162.72 Hz (male: 128.267 Hz, female: 197.18 Hz), 1.71%, 5.36%, 0.20 in OperaVOXTM. There was high intersoftware agreement for F0, jitter, shimmer with intraclass correlation coefficient. Conclusion Our results showed that the short-term variability of acoustic parameters in both MDVP and OperaVOXTM were useful for the objective assessment of voice quality in patients who received laryngeal microsurgery. OperaVOXTM is comparable to MDVP and has high intersoftware reliability with MDVP in measuring the F0, jitter, and shimmer

Development of Evaluation Method of Regional Contractility of Left Ventricle Using Gated Myocardial SPECT and Assessment of Reproducibility (게이트 심근 SPECT를 이용한 좌심실의 국소탄성률 평가방법 개발 및 재현성 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Kang, Won-Jun;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.355-363
    • /
    • 2003
  • Purpose: Regional contractility can be calculated using the regional volume change of left ventricle measured by gated myocardial SPECT image and curve of central artery pressure obtained from radial artery pressure data. In this study, a program to obtain the regional contractility was developed, and reproducibility of regional contractility measurement was assessed. Materials and Methods: Seven patients(male:female=5:2, $58{\pm}11.9$ years) with coronary artery diseases underwent gated Tc-99m MIBI myocardial SPECT twice without delay between two scans. Regional volume change of left ventricle was estimated using CSA (Cardiac SPECT Analyzer) software developed in this study. Regional contractility was iteratively estimated from the time-elastance curve obtained using the time-pressure curve and regional time-volume curve. Reproducibility of regional contractility measurement assessed by comparing the contractility values measured twice from the same SPECT data and by comparing those measured from the pair of SPECT data obtained from a same patient. Results: Measured regional contractility was $3.36{\pm}3.38{mm}Hg/mL$ using 15-segment model, $3.16{\pm}2.25{mm}Hg/mL$ using 7-segment model, and $3.11{\pm}2.57{mm}Hg/mL$ using 5-segment model. The harmonic average of regional contractility value was almost identical to the global contractility. Correlation coefficient of regional contractility values measured twice from the same data was greater than 0.97 for all models, and two standard deviations of contractility difference on Bland Altman plot were 1.5%, 1.0%, and 0.9% for 15-, 7-, and 5-segment models, respectively. Correlation coefficient of regional contractility values measured from the pair of SPECT data obtained from a same patient was greater than 0.95 for all models, and two standard deviations on Bland Altman plot were 2.2%, 1.0%, and 1.2%. Conclusion: Regional contractility of left ventricle measured using developed software in this study was reproducible. Regional contractility of left ventricle will be a new useful index for myocardial function after analysis of the clinical data.

A comparison of acoustic measures among the microphone types for smartphone recordings in normal adults (정상 성인에서 스마트폰 녹음을 위한 마이크 유형 간 음향학적 측정치 비교)

  • Jeong In Park;Seung Jin Lee
    • Phonetics and Speech Sciences
    • /
    • v.16 no.2
    • /
    • pp.49-58
    • /
    • 2024
  • This study aimed to compare the acoustic measurements of speech samples recorded from individuals with normal voices using various devices: the Computerized Speech Lab (CSL), a unidirectional wired pin-microphone (WIRED) suitable for smartphones, the built-in omnidirectional microphone (SMART) of smartphones, and Bluetooth-connected wireless earphones, specifically the Galaxy Buds2 Pro (WIRELESS). This study included 40 normal adults (12 males and 28 females) who had not visited an otolaryngologist for respiratory diseases within the past three months. Participants performed sustained vowel /a/ phonation for four seconds and reading tasks with sentences ("Walk") and paragraphs ("Autumn") in a sound-treated booth. Recordings were simultaneously conducted using the four different devices and synchronized based on the CSL-recorded samples for analysis using the MDVP, ADSV, and VOXplot programs. Compared with CSL, the Cepstral Spectral Index of Dysphonia (CSIDV, CSIDS) and Acoustic Voice Quality Index (AVQI) values were lower in the WIRED and higher in the SMART. The opposite trend was observed for the L/H spectral ratios (SRV and SRS), and the WIRELESS demonstrated task-specific discrepancies. Furthermore, both the fundamental frequency (F0) and the cepstral peak prominence of the vowel samples (CPPV) had intraclass correlation coefficient (ICC) values above 0.9, indicating high reliability. These variables, F0 and CPPV were considered highly reliable for voice recordings across different microphone types. However, caution should be exercised when analyzing and interpreting variables such as the SR, CSID, and AVQI, which may be influenced by the type of microphone used.