• 제목/요약/키워드: Hardened concrete

검색결과 566건 처리시간 0.025초

타설법에 따른 역타콘크리트의 강도에 관한 연구 (A Study on Strenth of Top-Down concrete on placing ways of kind)

  • 이영도;윤상혁;정근호;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.37-40
    • /
    • 2002
  • The purpose of this study is promote perfect of construction and progress of packing ability through comparison and analysis with quality, as placing ways and placing direction are changed. Kinds of concrete are general, high fluidity, and high Performance concrete. Classified with concrete as placing ways - direct ways, sheath way - and placing directing - flange direction, web direction - is analyzed section and strength of hardened concrete. The results of this study is belows the more fluid of concrete, the more useful to top-down method.

  • PDF

무기질 도료를 이용한 시멘트 경화체의 C1 ̄이온확산과 콘크리트의 내구성 평가 (Evaluation of Chloride ions Diffusion on Hardened Cement paste And Durability of Concrete Specimen Using Inorganic Coating Material)

  • 김인섭;이종규;추용식;김병익;신영훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.221-226
    • /
    • 2001
  • Chloride diffusion effect of cement paste, freezing and thawing test, carbonation of concrete specimen were carried out using inorganic coating material. According to the chloride ions diffusion test, it is elucidated that permeability and diffusion coefficient of Cl ̄ ions and apparent coefficient of coated cement paste is smaller than plain cement paste. A durability of coated concrete specimen was enhanced by the experiment result of concrete carbonation and freezing thawing test.

  • PDF

1,200kg/$\textrm{cm}^2$ 초고강도 콘크리트에 관한 실험적 연구 (An Experimental Study on the Ultra High Strength Concrete(Fc=1,200kg/$\textrm{cm}^2$))

  • 소현창;박태규;김재우;정병욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.133-136
    • /
    • 1994
  • This study is to investigate properties of the ultra high-strength concrete using silica rume and fly ash. For this purpose, the properties of fresh concrete and hardened concrete are examined with varing water-cement ratio, silica fume and fly ash content and so on. From these test results, it is possible to maunfacture the miximum strength of 1, 200kg/$\textrm{cm}^2$ with cement content 800kg/$\textrm{m}^3$, 18% water-cement ratio, 105 silica fume content.

  • PDF

도로구조물 적용을 위한 광촉매 콘크리트의 질소산화물(NOx) 제거효율 평가 (Evaluation of NOx Removal Efficiency of Photocatalytic Concrete for Road Structure)

  • 김영규;홍성재;이경배;이승우
    • 한국도로학회논문집
    • /
    • 제16권5호
    • /
    • pp.49-58
    • /
    • 2014
  • PURPOSES : In areas of high traffic volume, such as expressway across large cities, the amount of nitrogen oxides (NOx) emitted into the atmosphere as air pollution can be significant since NOx gases are the major cause of smog and acid rain. Recently, the importance of NOx removal has arisen in the world. Titanium dioxide ($TiO_2$), that is one of photocatalytic reaction material, is very efficient for removing NOx. The NOx removing mechanism of $TiO_2$ is the reaction of solar photocatalysis. Therefore, $TiO_2$ in road structure concrete need to be contacted with ultraviolet rays (UV) to be activated. In general, $TiO_2$ concretes are produced by replacement of $TiO_2$ as a part of concrete binder. However, considerable portion of $TiO_2$ in concrete cannot contact with the pollutant in the air and UV. Therefore, $TiO_2$ penetration method using the surface penetration agents is attempted as an alternative in order to locate $TiO_2$ to the surface of concrete structure. METHODS : This study aimed to evaluate the NOx removal efficiency of photocatalytic concrete due to various $TiO_2$ application method such as mix with $TiO_2$, surface spray($TiO_2$ penetration method) on hardened concrete and fresh concrete using surface penetration agents. The NOx removal efficiency of $TiO_2$ concrete was confirmed by NOx Analyzing System based on the specification of ISO 22197-1. RESULTS : The NOx removal efficiency of mix with $TiO_2$ increased from 11 to 25% with increasing of replacement ratio from 3 to 7%. In case of surface spray on hardened concrete, the NOx removal efficiency was about 50% due to application amount of $TiO_2$ with surface penetration agents as 300, 500 and 700g/m2. The NOx removal efficiency of surface spray on fresh concrete due to all experimental conditions, on the other hand, which was very low within 10%. CONCLUSIONS : It was known that the $TiO_2$ penetration method as surface spray on hardened concrete was a good alternative in order to remove the NOx gases for concrete road structures.

Effect of fly ash and metakaolin on the properties of fiber-reinforced cementitious composites: A factorial design approach

  • Sonebi, Mohammed;Abdalqader, Ahmed;Fayyad, Tahreer;Amaziane, Sofiane;El-Khatib, Jamal
    • Computers and Concrete
    • /
    • 제29권 5호
    • /
    • pp.347-360
    • /
    • 2022
  • Fiber-reinforced cementitious composites (FRCC) have emerged as a response to the calls for strong, ductile and sustainable concrete mixes. FRCC has shown outstanding mechanical properties and ductility where special fibres are used in the mixes to give it the strength and the ability to exhibit strain hardening. With the possibility of designing the FRCC mixes to include sustainable constituents and by-products materials such as fly ash, FRCC started to emerge as a green alternative as well. To be able to design mixes that achieve these conflicting properties in concrete, there is a need to understand the composition effect on FRCC and optimize these compositions. Therefore, this paper aims to investigate the influence of FRCC compositions on the properties of fresh and hardened of FRCC and then to optimize these mix compositions using factorial design approach. Three factors, water-to-binder ratio (w/b), mineral admixtures (total of fly ash and metakaolin by cement content (MAR)), and metakaolin content (MK), were investigated to determine their effects on the properties of fresh and hardened FRCC. The results show the importance of combining both FA and MK in obtaining a satisfactory fresh and mechanical properties of FRCC. Models were suggested to elucidate the role of the studied factors and a method for optimization was proposed.

석회석 미분말의 종류 및 함유율 변화에 따른 고유동 콘크리트의 특성 (The Properties of High Flowing Concrete with the Kind and Content of Limestone Powder)

  • 조중동;홍상희;조병영;장기영;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.267-270
    • /
    • 1999
  • In this paper, the application of limestone powder, which produced by being gathered electrically in the process of manufacturing of cement, to high fluidity concrete are investigated. According to the experimental results, especially, high viscosity and the loss of air content are accomplished by applying limestone powder as the partial substitution of fine aggregates. In case of hardened concrete, high compressive strength can be achieved by using limestone powder.

  • PDF

고로슬래그 분말을 혼화재로 사용한 고강도콘크리트의 기초적 성질에 대한 연구 (A Study on the Fundamental Properties of High-Strength Concrete Using Ground Granulated Blast-Furnace Slag as an Admixture)

  • 문한영;최연왕;문대중;송용규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.30-35
    • /
    • 1995
  • This paper presents fundamental experiment for the properties of high performance concrete in its fresh and hardened state made with ground granulated blast-furnace (GGBF) slag. The result is that the effect of decreasing xoncrete temperature is to the mixing ratio of GGBF slag, but it presents disadvantage in the slump loss phase. In addition to, we know that the splitting tensile strength, compressive strength and elastic modulus of concrete mixed with high fineness GGBF slag are increased at age 28days.

  • PDF

원주형 콘크리트 공시체의 캡핑종류별 압축강도 영향 (An Experimental Study on the Effect of Capping Type of Cylindrical Concrete Specimen on Compressive Strength)

  • 이상완;김수만;백승종;김광돈;이평석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.167-172
    • /
    • 2000
  • There are a variety of factors affecting measured compressive strength of hardened concrete. One of them is the end surface condition of concrete specimen. So, many capping methods have been developed for the specimen to meet the end condition requirement of ASTM C 39. A series of experimental strength comparison study was carried out using several representative capping methods, including pad capping method which is one of unbonded elastomeric capping system and was newly adopted in the ASTM standard. A comparison was also focused on their economy, convenience, harmfulness, etc.

  • PDF

콘크리트 슬래브 마감재료의 계면부착 거동에 관한 실험적 연구 (An experimental study on the adhesive properties of the top coated materials for concrete slab)

  • 이종열;손형호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.273-277
    • /
    • 1995
  • This study presents the physical and adhesive properties of the top coated materials for concrete slab. i.e, cement based top coated materials. epoxy mortar. The purpose of this study offers the investigation of construction factors to affect the quality of the coated materials over hardened concrete. The experimental results shows that the water content 3% of sand decline the strength and adhesive properties of epoxy mortar, on the other hand, dry surface and curing for cement based material.

  • PDF

폐도자기 분말도 변화에 따른 순환골재 사용 콘크리트의 물리적 특성에 관한 연구 (A Study on the Physical Properties of Recycled Aggregates Using Concrete of Changing Waste Pottery Blain Fineness)

  • 류현기;박정민;정재호;김의창;윤승조
    • 한국건설순환자원학회논문집
    • /
    • 제6권2호
    • /
    • pp.119-127
    • /
    • 2011
  • 본 연구의 목적은 폐도자기 분말도 변화에 따른 순환골재 강도 증진에 관한 연구로 유동성은 폐도자기 분말 치환율이 증가할수록 유동성이 감소하는 경향으로 나타났으며, 공기량은 KS 한도범위를 만족하는 것으로 나타났다. 압축강도는 순환골재 및 폐도자기 분말 치환율이 증가할수록 증가경향이고, 내구성으로 건조수축에 의한 길이변화는 폐도자기 미분말이 커질수록 다소 완만한 건조수축율을 나타내었고, 또한 단열온도상승은 순환골재 대체율 및 폐도자기 미분말이 증가할수록 최고온도에서 약 $6{\sim}10^{\circ}C$정도 낮게 나타내어 수화열에 의한 균열저감 효과를 발휘하였다. 순환골재 사용량을 30%정도 권장 하고 있지만 점토인 폐도자기의 분말도를 조절하여 사용할 경우 순환골재의 다량 사용시에는 콘크리트의 제반성상에 문제가 없을 것으로 판단되었다.

  • PDF