• Title/Summary/Keyword: Hard x-ray

Search Result 209, Processing Time 0.02 seconds

Radiative pressure feedback in obscured quasars

  • Jun, Hyunsung;Assef, Roberto;Ricci, Claudio;Stern, Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.36.4-36.4
    • /
    • 2019
  • Ricci et al. (2017, Nature, 549, 488) discovered a lack of high accretion rate, obscured Active Galactic Nuclei (AGN) in the hard X-ray selected Swift/BAT local AGN survey. This was interpreted as radiative pressure driven AGN feedback clearing its immediate vicinity composed of dusty gas (having an effectively low Eddington limit in the order of 0.01-0.1), and governing the level of nuclear obscuration. As we find Eddington-limited accretion and high extinction values among obscured, luminous AGN (quasars) however, it may be that the local X-ray AGN and the distant quasars undergo different feedback mechanisms in clearing their surroundings. In this study, we simply compare the obscuring column density and Eddington ratio values for quasars selected by various methods, including X-ray obscured, optically blue, infrared red/luminous, and submillimeter bright AGN. We find obscured quasars lying on the column density-Eddington ratio diagram previously unoccupied by Ricci et al., suggesting that radiative pressure is insufficient to clear its dusty structure at high luminosity, or that the dust in obscured quasars are more extended than the low luminosity counterparts to become fully transparent. We discuss alternative feedback scenarios that may be more relevant for obscured quasars.

  • PDF

A Method for Region-Specific Anomaly Detection on Patch-wise Segmented PA Chest Radiograph (PA 흉부 X-선 영상 패치 분할에 의한 지역 특수성 이상 탐지 방법)

  • Hyun-bin Kim;Jun-Chul Chun
    • Journal of Internet Computing and Services
    • /
    • v.24 no.1
    • /
    • pp.49-59
    • /
    • 2023
  • Recently, attention to the pandemic situation represented by COVID-19 emerged problems caused by unexpected shortage of medical personnel. In this paper, we present a method for diagnosing the presence or absence of lesional sign on PA chest X-ray images as computer vision solution to support diagnosis tasks. Method for visual anomaly detection based on feature modeling can be also applied to X-ray images. With extracting feature vectors from PA chest X-ray images and divide to patch unit, region-specific abnormality can be detected. As preliminary experiment, we created simulation data set containing multiple objects and present results of the comparative experiments in this paper. We present method to improve both efficiency and performance of the process through hard masking of patch features to aligned images. By summing up regional specificity and global anomaly detection results, it shows improved performance by 0.069 AUROC compared to previous studies. By aggregating region-specific and global anomaly detection results, it shows improved performance by 0.069 AUROC compared to our last study.

Microstructure and Magnetic Properties of Nanocomposite Sm2Fe15Ga2Cx/α-Fe Permanent Magnets

  • Cheng, Zhao-hua
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.18-23
    • /
    • 2003
  • In our previous work, microstructure and magnetic properties of two-phase exchange-coupled $Sm_2Fe_{15}Ga_2C_{x}$/$\alpha$-Fe nanocomposites have been investigated by means of x-ray diffraction, transmission electron microscopy and magnetization measurement. It was found the exchange coupling between the magnetically hard phase $Sm_2Fe_{15}Ga_2C_{x}$ and the magnetically soft one ${\alpha}$-Fe results in an enhancement of the remanence. The sizes of crystallites of both phases are, however much larger than the Block domain-wall width of the magnetically hard phase. This microstructure gives rise to a concave demagnetization curve and consequently reduces the maximum energy Product. In order to improve their magnetic properties, a few Percent of Zr, which may be effective to refine the microstructure through rapid quenching, was introduced into the nanocomposites. The addition of Zr was found to improve the magnetic properties significantly, Under optimum heat-treatment conditions, the remanence, coercivity and maximum energy Product increase from 0.65 T, 0.48 T and 50 kJ/$m^{3}$ for the Zr-free sample to 0.72 T, 0.77 T and 71.6 kJ/$m^{3}$ for the 1 at.% Zr-containing one, respectively, The improvements of magnetic properties are due to the refinement of microstructure by the addition of Zr.

A STUDY ON WEAR AND CORROSION RESISTANCE OF CrN$_{x}$ FILMS BY CATHODIC ARC ION PLATING PROCESS

  • Han, Jeon-G.;Kim, Hyung-J.;Kim, Sang-S.
    • Journal of Surface Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.545-548
    • /
    • 1996
  • $CrN_x$ films were deposited on SKD61 and S45C by cathodic arc ion plating process. In this study, the microstructure, microhardness, a hesion, wear and corrosion properties of the CrNx films were studied for various nitrogen partial pressures and the results were compared with those from the electroplated hard Cr. The crystal structure of the films was characterized by X-ray diffraction. Wear tests were performed under no lubricant condition at atmosphere by ball-on-disc type tribotester. Corrosion resistance of the films were studied by electrochemical corrosion test, measuring current demsity-potential curves. The results indicated that the $CrN_x$ films formed using ion plation method showed higer hardness and lower current density, friction coefficient than electroplated hard Cr. Consequently, the application of the CrNx coationgs by ion plating which is free of environmental pollution, is expected to improve lifetime of components in industrial practice.

  • PDF

In vivo visualization of liquid-feeding phenomena of a butterfly (나비 펌프의 구조와 동적 거동의 in vivo 가시화)

  • Lee, Seung-Chul;Kim, Bo-Heum;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.69-73
    • /
    • 2011
  • Butterflies have been known to suck viscous liquids through a long, cylindrical proboscis using the large pressure difference formulated by the cyclic expansion and contraction of a muscular pump located inside their head. However, there are few studies on the liquid-feeding phenomena in a live butterfly, because it is hard to observe the internal morphological structures under in vivo condition. In this study, the dynamic motion of the pump system in a butterfly was in vivo visualized using synchrotron X-ray micro-imaging technique to analyze the liquid-feeding mechanism. The period of the liquid-feeding process is about 0.3sec. The expansion stage is about two times larger than the contraction stage in one cycle. The cyclic variation of pump volume generate large negative suction pressure and the pressure difference inside the long proboscis of a butterfly is estimated to be larger than 1atm.

CLUSTER MERGERS AND NON-THERMAL PHENOMENA: A STATISTICAL MAGNETO-TURBULENT MODEL

  • CASSANO R.;BRUNETTI G.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.583-587
    • /
    • 2004
  • With the aim to investigate the statistical properties and the connection between thermal and non-thermal properties of the ICM in galaxy clusters, we have developed a statistical magneto-turbulent model which describes, at the same time, the evolution of the thermal and non-thermal emission from galaxy clusters. In particular, starting from the cosmological evolution of clusters, we follow cluster. mergers, calculate the spectrum of the magnetosonic waves generated in the ICM during these mergers, the evolution of relativistic electrons and the resulting synchrotron and Inverse Compton spectra. We show that the broad band (radio and hard x-ray) non-thermal spectral properties of galaxy clusters can be well accounted for by our model for viable values of the parameters (here we adopt a EdS cosmology).

Detection for demineralization of dental hard tissues using index-sequenced radiographs (방사선사진의 인덱스-순서 분석을 통한 치아경조직의 탈염화 검출)

  • Park, Dong-Hyun;Park, Young-Ho;Kim, Kyung-Sook;Park, Jeong-Hoon;Lee, Gi-Ja;Choi, Sam-Jin;Choi, Yong-Suk;Hwang, Eui-Hwan;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.2
    • /
    • pp.61-68
    • /
    • 2009
  • Purpose : The purpose of this study was to develop the radiographic technique for detecting the demineralization which is known as indication of dental caries. Materials and Methods: This technique was based on the comparing of multiple radiographs which was irradiated by multiple X-ray spectra. For the meaningful comparing, the multiple radiographs were reconstructed to the dosimetrically consistent images using a standard material. The difference of resulting images of same target with multiple spectra represents the difference of response of material as regards the spectra. Results : We have found about 10% of demineralization of dental hard tissues particularly in the proximal region through the analyzing of differences. Conclusion: Most intriguing thing in this investigation was that the method to analyze difference shows us to an anatomic structure of dental hard tissues even if absolute values of optical density were excluded during the procedures. (Korean J Oral Maxillofac Radiol2009; 39: 61-8)

  • PDF

Evaluation of Asymetric Film-Screen System (비대칭(非對稱) 필름-스크린 시스템에 관한 검토(檢討))

  • Huh, Joon;Kim, Jung-Min;Lee, Sun-Sook;Lee, In-Ja;Choi, Jong-Hak;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 1993
  • Asymetric system have been introduced in these years by KODAK company nam of Insight system for the purpose of improve the chest image. We have had a problem of chest radiology that it is very difficult to visualize the lung field and modiastinal region at one shot. That's why we are the RT using the technique of high voltage hard quality radiography in chest radiography. Also it is known the c-type wide latitude film can lift up the density of mediastinal structures. Authors investigated the photographic characteristics and physical structure of Insight system. Method 1. Investigated the structure of Emulsion layer. Calculated the particle size of Insight system using SEM(Scanning Electron Microscope). 2. Photographic characteristics has been compared the Insight system with the ortho KM/MG combination in $60{\sim}120kV$ range. Results 1. The particle size of backside film were investigated about 2 times larger that of front side film. 2. The front and backscreen's thickness ratio was detected 1 : 3.87, that the backscreen's thickness was thicker than frontscreen. 3. At the view point of photographic characteristics the frontside of insight system make up the contrast, backside make up the density at low exposure lesion.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Fabrication of WC-Ni-Si-B4C Composite and Diffusion Bonding with Stainless Steel (WC-Ni-Si-B4C계 초경합금 제조 및 스테인레스 스틸과의 확산접합)

  • Won, Jong-Wun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.594-598
    • /
    • 2015
  • The effects of Ni on the mechanical properties of WC-Xwt.%Ni-1.5wt.%Si-1.1wt.%$B_4C$ composite (X = 21.6, 23.6, 25.6 and 27.6 wt.%) were investigated in order to replace Co with Ni as the binder metal for hard materials based on WC-Co system. Using X-ray diffraction, optical microscopy, field-emission scanning electron microscopy results, the microstructure, pore distribution and grain size of the composites sintered at $1,150^{\circ}C$ were examined with different fraction (X = 21.6, 23.6, 25.6 and 27.6 wt.%) of binder metal Ni. The average WC grain size of the $WC-Ni-Si-B_4C$ composites was about $1{\mu}m$. The Rockwell hardness : A (HRA) and transverse rupture strength were about 88HRA and $110kgf/mm^2$, respectively. The obtained sample was bonded with SM45C at a temperature of $1,050^{\circ}C$. The thickness and mechanical properties of the bonded area were investigated with different dwell time at a bonding temperature of $1,050^{\circ}C$.