• 제목/요약/키워드: Haptic Device

검색결과 228건 처리시간 0.027초

햅틱 장치를 이용한 균형 훈련 시스템 및 효용성 검증 (A Balance Training System using a Haptic Device and Its Evaluations)

  • 윤정원;라힐 아프잘;표상훈;오민균
    • 제어로봇시스템학회논문지
    • /
    • 제20권9호
    • /
    • pp.971-976
    • /
    • 2014
  • Haptic device can be a useful rehabilitation tool in balance training. The proposed system is composed of a body-wear smartphone, Phantom Omni(R) device, and its control PC system. Ten young healthy subjects performed balance tasks with different postures during 30 seconds with their eyes closed. An Android program on the smartphone transferred mediolateral (ML) and anteroposterior (AP) tilt angles to the PC system, which can generate haptic command through haptic device. Statistical data analysis was performed using MATLAB(R). COP (Center of Pressure) related indexes were measured to see reduction in body sway. ANOVA showed that haptic device significantly reduced body sway. Intuitive balance guidance could be generated using an economical and small-sized commercial haptic device, making the system efficient.

6자유도 병렬형 햅틱장치를 이용한 구멍뚫기 작업의 햅틱 디스플레이 (Haptic Display of A Puncture Task with 4-legged 6 DOF Parallel Haptic Device)

  • 김형욱;서일홍
    • 전자공학회논문지SC
    • /
    • 제41권6호
    • /
    • pp.1-10
    • /
    • 2004
  • 본 논문에서는 가상 구멍뚫기 작업의 표현을 위한 햅틱 렌더링 시스템을 제안하였다. 가상 모델을 만들기 위하여 영상 처리기법과 Delaunay 삼각형을 이용하였고, 실시간 어플리케이션에 적용하기 위해 간단하면서도 효율적인 후크의 법칙을 이용하여 힘을 생성하였다. 또한, 직렬형 메커니즘으로 표현하기 어려운 큰 힘을 표현하면서, 병렬형 메커니즘의 특이점 문제를 함께 해결하기 위하여 여유구동 6자유도 병렬형 메커니즘을 햅틱장치로 제안하였고 두 종류의 구멍뚫기 실험을 통하여 큰 힘을 표현할 수 있는 능력을 검증하였다.

Design of a new five-link haptic device considering its dynamics

  • Moon, Chan-Woo;Lee, Sung-Ho;Chung, J.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2535-2539
    • /
    • 2003
  • The haptic system becomes an essential device in the area of tele-operation, video entertainment and medical operation. To control a haptic device, impedance control method is widely used, but force sensor costs so much that open-loop control method is usually preferred for commercial purpose. In this case, modeled/un-modeled dynamics affects the performance of device. In this paper, we present a new 3DOF five-link type haptic device that we can reduce the effect of device dynamics and compensate its dynamics. We also evaluate its performance.

  • PDF

2D 햅틱 인터페이스 장치 설계 및 이를 이용한 가상 에어하키 시스템 구현 (Design and fabrication of a 2D haptic interface apparatus and the realization of a virtual air-hockey system using the device)

  • 백종원;강지민;용호중;최대성;장태정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.78-80
    • /
    • 2005
  • Haptic interface apparatus is the device which can offer users virtual reality not only by visualization of virtual space but also by force or tactile feedback. In this paper, we designed and fabricated a 2D haptic interface device that can be used for various purposes, and implemented a virtual air-hockey system that users can easily find in game rooms. By suitable modeling and haptic rendering, users can feel the impact and the reaction force with his/her hand holding the handle through 2D haptic interface device when he/she hit an air-hockey puck with the handle. Through the trial demonstration. we observed the reasonable effect of direction and speed of a ball like doing in reality.

  • PDF

Direct Control of a Passive Haptic Device Based on Passive Force Manipulability Ellipsoid Analysis

  • Changhyun Cho;Kim, Munsang;Song, Jae-Bok
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권2호
    • /
    • pp.238-246
    • /
    • 2004
  • In displaying a virtual wall using a passive haptic device equipped with passive actuators such as electric brakes, unsmooth motion frequently occurs. This undesirable behavior is attributed to time delay due to slowness in the virtual environment update and force approximation due to the inability of a brake to generate torque in arbitrary directions. In this paper a new control scheme called direct control is proposed to achieve smooth display on the wall-following task with a passive haptic device. In direct control, brakes are controlled so that the normal component of a resultant force at the end-effector vanishes, based on the force analysis at the end-effector of the passive haptic device using the passive FME (Force Manipulability Ellipsoid). Various experiments have been conducted to verify the validity of the direct control scheme with a 2-link passive haptic system.

케이블 컨듀잇 구조의 수술용 햅틱 마스터 장치의 개선과 smooth backlash inverse를 이용한 backlash 보정 (Improvement of surgical haptic master device using cable-conduit and backlash compensation by smooth backlash inverse)

  • 최우혁;윤성민;이민철
    • 로봇학회논문지
    • /
    • 제9권1호
    • /
    • pp.48-56
    • /
    • 2014
  • In robotic surgery, a surgeon checks only a surgical site of patient in the progress of surgery by vision and sound information. In order to solve this limited information, the haptic function is necessary. And haptic surgical robot is also necessary to design a haptic master device. The master device for laparoscope operation with cable-conduit was developed in previous research to give haptic function. It suggested a possibility of developing a master device by using the cable-conduit. However, it is very inconvenient to use. Therefore, this paper suggests a new mechanism design structure to solve the problems of the previous work by new forming a new master device. And it has proved that it's usability is better than previous one. Furthermore it has also experimented and analyzed that a backlash of new master device is compensated by smooth backlash inverse algorithm.

텐던 구동방식의 장착형 역/촉감 제시기구의 개발에 관한 연구 (Development of exoskeletal type tendon driven haptic device)

  • 이규훈;최혁렬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1285-1288
    • /
    • 1997
  • The basic technology of virtual reality can be described as the cognition of the condition change in virtual world by stimulating the visual, auditory, kinesthetic and tactile sensation. Among these, the kinesthetic and tactile sensation is one of the most important things to recognize the interaction. In this paper, it is addressed the haptic device which help the human feel the sense of the operator, and is designed in modular type to expand for five fingers later. the haptic device is driven by tendon and ultrasonic motors located in the wrist part. Each joint is actuated by coupled tendons and adopts more actrator by one than the number of the joints, called 'N+1 type'. The haptic device adopts metamorphic 4-bar linkage structure and the length of linkages, shape and the location of joint displacement sensor are optimized through the analysis.

  • PDF

ER 유체를 이용한 햅틱 마스터와 가상 MIS 환경의 연동제어 (Force-Feedback Control of an Electrorheological Haptic Device in MIS Virtual Environment)

  • 강필순;한영민;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.422-427
    • /
    • 2006
  • This paper presents force-feedback control performance of a haptic device in virtual environment of minimally invasive surgery(MIS). As a first step, based on an electrorheological(ER) fluid and spherical geometry, a new type of master device is developed and integrated with a virtual environment of MIS such as a surgical tool and human organ. The virtual object is then mathematically formulated by adopting the shape retaining chain linked(S-Chain) model. After evaluating reflection force, computational time, and compatibility with real time control, the virtual environment of MIS is formulated by interactivity with the ER haptic device in real space. Tracking control performances for virtual force trajectory are presented in time domain, and theirtrackingerrorsareevaluated.

  • PDF

전기유변 유체를 이용한 햅틱 마스터와 가상의 최소침습수술 환경과의 연동제어 (Force-feedback Control of an Electrorheological Haptic Device in MIS Virtual Environment)

  • 강필순;한영민;최승복
    • 한국소음진동공학회논문집
    • /
    • 제16권12호
    • /
    • pp.1286-1293
    • /
    • 2006
  • This paper presents force-feedback control performance of a haptic device in virtual environment of minimally invasive surgery(MIS). As a first step, based on an electrorheological (ER) fluid and spherical geometry, a new type of master device is developed and integrated with a virtual environment of MIS such as a surgical tool and human organ. The virtual object is then mathematically formulated by adopting the shape retaining chain linked(S-chain) model. After evaluating reflection force, computational time, and compatibility with real time control, the virtual environment of MIS is formulated by interactivity with the ER haptic device in real space. Tracking control performances for virtual force trajectory are presented in time domain.