터빈 로터 반사각에 따른 의료용 에어터빈 핸드피스의 성능에 관한 수치 해석 (Numerical Analysis on Performance of Dental Air Turbine Handpiece for Various Reflection Angles of Turbine Rotor)

  • 이정호;이상도;김귀순
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.29-32
    • /
    • 2008
  • Dental high-speed air turbine handpieces have been used as a dental cutting tool in clinical dentistry for over 50 years, yet little study has been reported on their flow and performance analysis. Therefore it is necessary to investigate turbine for the performance improvements of an air turbine handpiece. This paper presents pressure on turbine rotor and flow analysis in air turbine handpiece using CFD (computational fluid dynamics). Characteristics on each flow and pressure for four various reflection angles of turbine rotor are presented, and then performance change is analyzed about air turbine handpieces by CFD results.

  • PDF

와동면(窩洞面)의 주사전자현미경적(走査電子顯微鏡的) 연구(硏究) (A SCANNING ELECTRON MICROSCOPIC STUDY OF CAVITY WALL)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제11권1호
    • /
    • pp.11-18
    • /
    • 1985
  • The purpose of this study was to observe the facial, lingual and gingival walls of the cavity walls with various kinds of cutting tools. Class II cavities were prepared in newly extracted sound humen mandibular 1st left premolars, and observed in Sanning electron microscope. Diamond point (#201) and Tungsten Carbide burs (#170L) were used in ultra high speed handpieces (rpm 200000), and Tungsten Carbide bur (#702) and Steel bur (#560) were used in conventional handpieces (rpm 6000). All cavities were prepared under water spray, except for some which were finished with a dry abrasive stone (#57). Some cavities were finished with chisels (#41, 42, 83). The following results were obtained. 1. The cavity walls prepared with Diamond point were rougher than the cavity walls with Carbide burs and Steel burs. 2. The chisels were produced the smoothest surface. 3. The cavity walls which were prepared with cutting blades rotated toward enamel surface from outside, were smoother than cavity walls which were prepared with cutting blades rotated toward outside from the enamel surface.

  • PDF

귀 모형을 이용한 치과 핸드피스에 대한 소음 저감 장치의 효과 분석 (Effect of Noise Cancelling Devices on Dental Handpieces Using Ear Model)

  • 모승한;강준구;김익환;최형준;송제선;신유석
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.62-69
    • /
    • 2020
  • 이 연구는 치과 핸드피스의 소음 수준과 소음 저감 장치의 효과를 평가하기 위한 것이다. 귀 모형은 치과용 핸드피스 작동 중에 내이에 전달되는 소음의 수준을 측정할 수 있도록 설계되었다. 소음의 크기는 귀 모형과 휴대용 소음 측정기를 사용하여 다양한 조건에서 측정되었다. 시판되는 4종의 소음 저감 장치를 귀 모형에 적용한 후 같은 조건에서 소음 수준을 측정한 뒤 비교하였다. 치과 핸드피스의 소음 수준은 조건에 따라 약 82.5 - 84.4 dB이었다. 4종의 소음 저감 장치를 적용했을 때 소음은 67.4 - 73.8 dB로 감소했다. 4종의 장치 모두 핸드피스의 소음을 줄이는데 유의한 효과가 있었다. 강도와 노출 시간을 고려할 때, 치과 소음은 치과 의료진에게 청력 손상을 일으킬 수 있다. 직업적 청력 손상 위험을 예방하기 위해 소음 저감 장치 사용을 고려할 수 있다.

여러 근관치료용 무선 핸드피스의 진동양상 비교 (Comparison vibration characteristics of several wireless endodontic handpieces)

  • 이보경;이윤;박세희;조경모;김진우
    • 구강회복응용과학지
    • /
    • 제38권2호
    • /
    • pp.81-89
    • /
    • 2022
  • 목적: 여러 근관치료용 무선 핸드피스에서 발생되는 진동의 크기와 양상을 비교해 보고자 한다. 연구 재료 및 방법: 클램프로 고정시킨 5개의 근관치료용 무선 핸드피스(X Smart IQ, E Connect S, Endo A Class, ENDOIT, TRAUS ENDO)의 헤드부분에 가속도계를 이용하여 회전운동과 왕복운동방식으로 동작할 때 핸드피스 자체에서 발생하는 진동가속도를 측정하였다. 결과: 모든 근관치료용 무선 핸드피스에서 회전운동보다 왕복운동에서의 평균진동가속도가 유의하게 높게 나타났다(P < 0.001). 회전운동에서는 급격한 진동의 크기 변화 없이 일정한 진폭의 반복적인 진동그래프가 얻어졌으며, 평균진동 가속도 값은 X Smart IQ, Endo A Class, ENDOIT, E Connect S, TRAUS ENDO 순이었고(P < 0.001), X Smart IQ와 Endo A Class 사이에는 통계적으로 유의한 차이가 없었다. 왕복운동에서는 한 주기 안에 특정 지점에서 큰 진폭의 피크가 나타나는 양상의 진동그래프가 얻어졌으며, 평균진동가속도 값은 X Smart IQ, E Connect S, Endo A class, ENDOIT, TRAUS ENDO 순이었다(P < 0.001). 결론: 무선 근관치료용 핸드피스 종류에 관계없이 회전운동보다 왕복운동에서 더 큰 진동이 발생하였다. 왕복운동에서는 모든 핸드피스에서 진동의 차이가 있었다(P < 0.001).

핸드피스용 BLDC 모터 속도 제어시스템의 설계 (Design of Brushless DC Motor Speed Control System for Handpieces)

  • 곽성우;양정민
    • 한국전자통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.597-604
    • /
    • 2016
  • 본 논문에서는 미용 목적의 핸드피스에 사용가능한 BLDC 모터의 속도 제어 시스템을 구현한다. 저비용 개발을 위해 모터 내부의 홀 센서 값을 속도 제어에 이용하였다. 모터 전원 회로와 드라이버 회로는 가정용 220V 전원을 입력으로 사용하도록 설계하였으며 별도의 다른 전원은 필요로 하지 않는다. 핸드피스 작업 시 발생하는 부하 변동에 따른 급속한 속도 증가를 방지하기 위해 별도의 과속 방지 제어기를 탑재하였다. 개발된 제어 시스템은 5,000~30,000 RPM 구간에서 운용 가능하다. 본 연구에서 개발된 핸드피스 모듈에서 부하 변동이 있음에도 불구하고 모터의 속도가 일정하게 유지됨을 실험으로 입증한다.

Subcutaneous Emphysema and Pneumomediastinum during Extraction of Maxillary Third Molar: A Case Report

  • Jung, Da-Woon;Yoon, Hyun-Joong;Lee, Sang-Hwa
    • Journal of Korean Dental Science
    • /
    • 제7권1호
    • /
    • pp.25-30
    • /
    • 2014
  • Subcutaneous emphysema and pneumomediastinum is a relatively uncommon phenomenon. It may occur secondary to dental treatment using high-speed air turbine handpieces, especially after extraction of tooth. Subcutaneous emphysema is often limited only to the areas of head and neck, but also can involve deeper structures. Thorough examination and conservative treatment of these problems are essential in preventing life-threatening complications such as airway obstruction and mediastinitis. The subject of this report is a 57-year-old woman with subcutaneous emphysema and pneumomediastinum during the extraction of maxillary third molar using high-speed air turbine handpiece. If there isn't any appropriate measure, severe complications may occur. Therefore it is important to be well-informed of proper diagnosis and treatment. This article shall present a case report with literature review.

치기공용 에어터빈 핸드피스의 성능에 대한 수치해석적 연구 (A NUMERICAL STUDY ON PERFORMANCE CHARACTERISTICS OF DENTURE HIGH-SPEED AIR TURBINE HANDPIECE)

  • 고동훈;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.271-276
    • /
    • 2010
  • High-speed air turbine handpieces have been used as a denture cutting tool in clinical dentistry for over 50 years. The denture high-speed air turbine handpiece is currently used as the main means of cutting tooth structure and restorative materials in a wide range of denture manufacturing. But little study has been reported on their performance analysis. This research would show the performance characteristics of denture air turbine handpiece by using CFD.

  • PDF

치과 진료실내의 세균오염도와 영향인자에 관한 연구 (A Study on Bacterial Concentrations in Dental Offices)

  • 윤경옥;박희진;손부순
    • 한국환경보건학회지
    • /
    • 제40권6호
    • /
    • pp.469-476
    • /
    • 2014
  • Objectives: The purpose of this study was to identify the stains causing infections in dental clinics by analyzing bacterial contamination, as well as to suggest improvements for infection control in dental clinics. Methods: In this study, a questionnaire survey of 47 dental hospitals and clinics located in Gyeonggi-do and Incheon, South Korea was administered from June 2013 to September 2013 and used to investigate the practice rates of infection control by dental hygienists and to analyze the bacterial contamination levels in dental offices. Results: In the studied institutions, the bacterial contamination levels of water lines were $20.9{\times}10^3$ colony forming units (CFU)/mL for three-way syringes, $12.7{\times}10^3CFU/mL$ for high-speed handpieces and $9.8{\times}10^3CFU/mL$ for gargling water. The bacterial contamination levels of surfaces were $44.9{\times}10^3CFU/mL$ in cuspidors, higher than in unit chairs ($2.9{\times}10^3CFU/mL$) and light handles ($6.7{\times}10^3CFU/mL$). The mean bacterial cell count of water lines and surfaces was relatively high in all establishments founded 11 years ago or more, and the mean bacterial cell count of waterline handpieces was $6.27{\times}10^3CFU/mL$ in establishments founded between one and five years ago, $11.16{\times}10^3CFU/mL$ six to ten years ago and $20.04{\times}10^3CFU/mL$ 11 years ago or more, which suggests that earlier foundation is associated with higher bacterial contamination levels with a statistical difference (p<0.01). Similarly, the mean bacterial cell count of cuspidors using water from water lines was also $70.16{\times}10^3CFU/mL$ in at least 11-year-old establishments, statistically significantly higher among in one- to five-year-old ($4.61{\times}10^3CFU/mL$) and six- to ten-year-old clinics ($47.89{\times}10^3CFU/mL$) (p<0.05). Conclusion: This study may be utilized to improve the bacterial contamination levels in dental offices by controlling the characteristics and environmental factors of dental offices that affect the microbial contamination of waterlines and surfaces in such institutions.

터빈 블레이드 형상에 따른 의료용 에어터빈 핸드피스의 성능 특성에 관한 수치적 연구 (Numerical Study on the Effect of Turbine Blade Shape on Performance Characteristics of a Dental Air Turbine Handpiece)

  • 이정호;김귀순
    • 한국추진공학회지
    • /
    • 제13권1호
    • /
    • pp.34-42
    • /
    • 2009
  • 의료용 고속 에어터빈 핸드피스는 치아 절삭 도구로써 지난 50년 동안 치의학분야에서 사용되어왔으나, 그것에 대한 성능 연구가 많이 없었다. 그래서 수치해석을 이용하여 핸드피스 터빈 형상의 성능 특성을 본 논문에서 연구하였다. 정상상태 방법 중 하나인 프로즌 로터 방식을 이용하여 터빈 블레이드의 위치에 따라 5가지의 경우에서 계산하였다. 형상과 반사각에 따른 터빈 블레이드의 특성을 분석하였다. 계산 결과에 따르면, 터빈 블레이드의 반사각이 증가할 때 토크가 증가하였다.