• Title/Summary/Keyword: Handling Quality

Search Result 526, Processing Time 0.03 seconds

An Image Warping Method for Implementation of an Embedded Lens Distortion Correction Algorithm (내장형 렌즈 왜곡 보정 알고리즘 구현을 위한 이미지 워핑 방법)

  • Yu, Won-Pil;Chung, Yun-Koo
    • The KIPS Transactions:PartB
    • /
    • v.10B no.4
    • /
    • pp.373-380
    • /
    • 2003
  • Most of low cost digital cameras reveal relatively high lens distortion. The purpose of this research is to compensate the degradation of image quality due to the geometrical distortion of a lens system. The proposed method consists of two stages : calculation of a lens distortion coefficient by a simplified version of Tsai´s camera calibration and subsequent image warping of the original distorted image to remove geometrical distortion based on the calculated lens distortion coefficient. In the lens distortion coefficient calculation stage, a practical method for handling scale factor ratio and image center is proposed, after which its feasibility is shown by measuring the performance of distortion correction using a quantitative image quality measure. On the other hand, in order to apply image warping via inverse spatial mapping using the result of the lens distortion coefficient calculation stage, a cubic polynomial derived from an adopted radial distortion lens model must be solved. In this paper, for the purpose of real-time operation, which is essential for embedding into an information device, an approximated solution to the cubic polynomial is proposed in the form of a solution to a quadratic equation. In the experiment, potential for real-time implementation and equivalence in performance as compared with that from cubic polynomial solution are shown.

Improvement Plan of NFRDI Serial Oceanographic Observation (NSO) System for Operational Oceanographic System (운용해양시스템을 위한 한국정선해양관측시스템 발전방향)

  • Lee, Joon-Soo;Suh, Young-Sang;Go, Woo-Jin;Hwang, Jae-Dong;Youn, Seok-Hyun;Han, In-Seong;Yang, Joon-Yong;Song, Ji-Young;Park, Myung-Hee;Lee, Keun-Jong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.3
    • /
    • pp.249-258
    • /
    • 2010
  • This study seeks to improve NFRDI Serial Oceanographic observation (NSO) system which has been operated at current observation stations in the Korean Seas since 1961 and suggests the direction of NSO for practical use of Korean operational oceanographic system. For improvement, data handling by human after CTD (Conductivity-Temperature-Depth) observation on the deck, data transmission, data reception in the land station, and file storage into database need to be automated. Software development to execute QA/QC (Quality Assurance/Quality Control) of real-time oceanographic observation data and to transmit the data with conversion to appropriate format automatically will help to accomplish the automation. Inmarsat satellite telecommunication systems with which have already been equipped on board the current observation vessels can realize the real-time transmission of the data. For the near real-time data transmission, CDMA (Code Division Multiple Access) wireless telecommunication can provide efficient transmission in coastal area. Real-time QA/QC procedure after CTD observation will help to prevent errors which can be derived from various causes.

Minimizing Nutrient Loading from SCB Treated Paddy Rice Fields through Water Management (SCB 액비 시용 논에서 물관리를 통한 양분의 수계 부하 최소화 방안)

  • Kim, Min-Kyeong;Kwon, Soon-Ik;Kang, Seong-Soo;Jung, Goo-Bok;Hong, Seung-Chang;Chae, Mi-Jin;So, Kyu-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.671-675
    • /
    • 2012
  • This study was conducted to establish the BMPs (Best Management Practices) for preventing pollutant loadings from paddy rice field applied livestock liquid manure from 2008 through 2011. Cultivated paddy rice fields (Gyeonggi province, Korea) were treated with SCB (Slurry composting and bio-filtration process) liquid fertilizer. The BMPs for paddy rice field developed in this study includes: 1) the controlling a drainage water gate in paddy rice field from right after SCB liquid fertilizer application to 3 weeks after rice transplanting; 2) livestock liquid fertilizer application to paddy rice soils in 20 days before rice transplanting to encourage the utilization of liquid fertilizer; 3) preservation of surface water depth to 5 cm in a paddy field right after SCB liquid fertilizer applied to minimize a water pollution and enhance the utilization of liquid fertilizer; and 4) blocking a water gate at least for 2 days to inactivate E. coli survival. The findings of this study will provide useful and practical guideline to applicators of agricultural soil in deciding appropriate handling and time frames for preventing pollution of water quality for sustainable agriculture.

A Study on the Automatic Inspection of Sewer Facility Map (하수도시설물도 자동 검수 방안 연구)

  • Kim, Chang-Hwan;Ohk, Won-Soo;Yoo, Jae-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.2
    • /
    • pp.67-78
    • /
    • 2006
  • Local governments began to construct geographic information system to improve government productivity and performance. In support, central government organized a national commission for GIS. The master plan by NGIS has been the base for local government to participate in the construction of GIS at the local level in the under ground facilities management including water and sewers. The challenge faced by sewer facility managers includes controlling 'data accuracy'. The input for sewer data handling for efficient performance in local government requires accurate data. However data manipulation to get the 'good quality' data can be burdensome. Thus, the aim of this research is to provide the appropriate tool to guarantee the high quality of digital data in sewer facility management. It is helpful to pass the data examination by government as well as to insure confidence of decision and data analysis works in local government. In this research, error types of sewer data were classified and pointed the limitation of traditional examination methods. Thus this research suggested more improved method for finding and correcting errors in data input using sewer volume analysis and prediction model as immigrating sewer facility management work to Geographic Information System.

  • PDF

A Study on a Ku-Band High Power and High Efficiency Radial Combiner (Ku 대역 고출력 고효율 Radial Combiner에 대한 연구)

  • Yun, Song-Hyun;Kim, Si-Ok;Lee, Su Hyun;Lim, Byeong-Ok;Lee, Bok-Hyung;Jeon, Yong-Kyu;Kim, Hyun-Kyu;Yoo, Young-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.400-409
    • /
    • 2017
  • We have studied a combiner that can withstand high power while minimizing insertion loss in high frequency band. In particularly, because the output power that can be output per unit elements is much lower in the Ku band and above than in the low frequency band, it is necessary to combine many semiconductor elements in order to make a high power SSPA. A planar combiner such as a microstrip, as the number of elements to be combined increases, the insertion loss increases proportionally, resulting in a reduction in the overall system efficiency and an increase heating value also. The planar combiner also have some problems due to the low power handling rate. To improve these problems, we proposed a Cavity Radial Combiner. A Ku band 16-way Cavity Radial Combiner was fabricated and measured. As a result, it was tested 14dB return loss and over 94.5 % output combining efficiency in design band.

Performance Analysis of Population-Based Bandwidth Reservation Scheme with Various Request Reservation Ratios (요청 예약 비율에 따른 Population-Based Bandwidth Reservation 구조의 성능 분석)

  • Kwon, Se-Dong;Han, Man-Yoo;Park, Hyun-Min
    • The KIPS Transactions:PartC
    • /
    • v.9C no.3
    • /
    • pp.385-398
    • /
    • 2002
  • To accommodate the increasing number of mobile terminals in the limited radio spectrum, wireless systems have been designed as micro/picocellular architectures for a higher capacity. This reduced coverage area of a cell has caused a higher rate of hand-off events, and the hand-off technology for efficient process becomes a necessity to provide a stable service. Population-based Bandwidth Reservation(PBR) Scheme is proposed to provide prioritized handling for hand-off calls by dynamically adjusting the amount of reserved bandwidth of a cell according to the amount of cellular traffic in its neighboring cells. We analyze the performance of the PBR scheme according to the changes of a fractional parameter, f, which is the ratio of request reservation to the total amount of bandwidth units required for hand-off calls that will occur for the next period. The vague of this parameter, f should be determined based on QoS(Quality of Service) requirement. To meet the requirement the value of Parameter(f) must be able to be adjusted dynamically according to the changing traffic conditions. The best value of f can be determined by a function of the average speed of mobile stations, average call duration, cell size, and so on. This paper considers the average call duration and the cell size according to the speed of mobile stations. Although some difference exists as per speed, in the range of 0.4 $\leq$ f $\leq$ 0.6, Blocking Probability, Dropping Probability and Utilization show the best values.

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

High-Value Materials from Microalgae (미세조류 유래 고부가 유용물질)

  • 오희목;최애란;민태익
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.2
    • /
    • pp.95-102
    • /
    • 2003
  • Microalgae are a diverse group of photosynthetic organisms and abundant in every ecosystem in the biosphere. They are common in aqueous environments including marine, brackish and fresh waters and in some habitats that lack eukaryotic life such as some hot springs and highly alkaline lakes. Microalgal biotechnology that is focused on the microalgae-based production of a variety of useful materials such as pharmaceutical comfounds, health foods, natural pigments, and biofuels is considered as an important discipline with the development of biotechnology. In addition, the mass cultivation of microalgae can also contribute to improving the environmental quality by reducing the concentration of $CO_2$ which is one of major gases lead to global warming. Consequently, it seems that the microalgae can be used as an efficient, renewable, environmentally friendly source of high-value biomaterials such as chemicals, pigments, energy, etc. and the microalgal biotechnology will most likely represent a larger portion of modern biotechnology.

Road Runoff Treatment using Pilot Scale-NPS Treatment Plant Filling up Expended Polypropylene Media (발포고분자여재가 충전된 파일럿 규모의 비점오염물질 처리장치를 이용한 도로 강우유출수 처리)

  • Kim, Seogku;Oh, Hyecheol;Ahn, Jaehwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.711-718
    • /
    • 2014
  • Investigated the processing characteristics of the pollutants and runoff due to storm events in the actual application of the road fields and a Non-Point Sources (NPS) pilot scale equipment. This phenomenon has occurred in the influent bypass the blockage occurs after 90 min the expended polymeric media was filled with filtered column. When entering a treatment tank SS 200 mg/L or more high concentration of effluent treatment efficiency was reduced from the reaction time 60 min. Influent concentration less then SS 180 mg/L was stable handling. The $COD_{Cr}/SS$ ratio were analyzed with 0.67, median value. Showed 92.1% and 82.3% respectively with an average removal rate of the SS and the $COD_{Cr}$. If the influent concentration of TP is the 0.5 mg/L or less, the quality of the treated water is 0.1 mg/L levels were expressed in a stable process. And when entering the 1.0 mg/L or more of the treated water, had a greater than average 0.2 mg/L. If the influent concentration of TN is 4~10 mg/L, the treatment water quality level was kept a 1.5~3.0 mg/L. The average removal efficiency of TP and TN respectively 73.9%, 50.4%.

Efficient Patient Information Transmission and Receiving Scheme Using Cloud Hospital IoT System (클라우드 병원 IoT 시스템을 활용한 효율적인 환자 정보 송·수신 기법)

  • Jeong, Yoon-Su
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.4
    • /
    • pp.1-7
    • /
    • 2019
  • The medical environment, combined with IT technology, is changing the paradigm for medical services from treatment to prevention. In particular, as ICT convergence digital healthcare technology is applied to hospital medical systems, infrastructure technologies such as big data, Internet of Things, and artificial intelligence are being used in conjunction with the cloud. In particular, as medical services are used with IT devices, the quality of medical services is increasingly improving to make them easier for users to access. Medical institutions seeking to incorporate IoT services into cloud health care environment services are trying to reduce hospital operating costs and improve service quality, but have not yet been fully supported. In this paper, a patient information collection model from hospital IoT system, which has established a cloud environment, is proposed. The proposed model prevents third parties from illegally eavesdropping and interfering with patients' biometric information through IoT devices attached to the patient's body at hospitals in cloud environments that have established hospital IoT systems. The proposed model allows clinicians to analyze patients' disease information so that they can collect and treat diseases associated with their eating habits through IoT devices. The analyzed disease information minimizes hospital work to facilitate the handling of prescriptions and care according to the patient's degree of illness.