• Title/Summary/Keyword: Handle size

Search Result 291, Processing Time 0.027 seconds

A study on the determination of an optimal handle diameter for a signal billy (신호봉 손잡이의 최적 굵기 결정에 관한 연구)

  • 변승남;이동훈
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.15-27
    • /
    • 1997
  • The objectives of this study were twofold; (1) to determine an optimal handle size of a signal billy, based on the subjective assessment of grip comfort and (2) to investigate the relationship between hand anthropometry and the optimal handle size. Thirty-seven university male students were asked to rate seven cylindrical handles of different diameters in barehanded and gloved conditions, respectively. Among these handles, 3.5cm diameter of the handle size was found to be the most comfortable, in both bardhanded and gloved conditionsl. However, no statistically significant reduction in grip comfort occurred within handle diameter ranging from 2.5cm to 4.0cm. As the handle diameter was deivated from the range, grip discomfort in creased significantly. A Spearman rank correlation coefficient test revealed that hand anthropometries such as finger lengths, hand circumference, and hand thickness were statistically significant factors on the determination of the optimal handle size. The implications of these findings were discussed. The results of this study can be used as guidelines in designing the hand tools for power grip.

  • PDF

Evaluation of Individual Finger Force to Grip Strength in Various Grip Spans and Hand Sizes (파지 폭과 손 크기에 따른 각 손가락이 총 악력에 미치는 영향 분석)

  • Jung, Myung-Chul;Kim, Dae-Min;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.59-65
    • /
    • 2007
  • In this study, six grip spans (45mm-65mm) were tested to evaluate the effects of handle grip span and user's hand size on maximum grip strength, individual finger force, and subjective ratings of comfort using a digital dynamometer with individual force sensors. Forty-six males were assigned into three hand size groups according to their hand lengths. Results showed that overall 55mm and 50mm grip spans were the most comfortable sizes and associated with the highest grip strength in the maximum grip force exertions, whereas 65mm grip span was rated as the least comfortable size as well as the lowest grip strength. In the interaction effect of grip span and hand size, small and middle hand sized participants rated the best preference and the least preference grip spans differently with large hand sized participants. With respect to the analysis of individual finger force, the middle finger force was the strongest and the highest contribution to the total finger force, followed by ring, index and little fingers. In addition, it was noted that each finger had a different optimal grip span for exerting maximum force resulting in a bowed contoured shaped handle for two-handle hand tools. Thus, the grip spans for two-handle hand tools might be designed according to the users' hand and finger anthropometrics to maximize performance and subjective perception of comfort.

Sample size calculations for clustered count data based on zero-inflated discrete Weibull regression models

  • Hanna Yoo
    • Communications for Statistical Applications and Methods
    • /
    • v.31 no.1
    • /
    • pp.55-64
    • /
    • 2024
  • In this study, we consider the sample size determination problem for clustered count data with many zeros. In general, zero-inflated Poisson and binomial models are commonly used for zero-inflated data; however, in real data the assumptions that should be satisfied when using each model might be violated. We calculate the required sample size based on a discrete Weibull regression model that can handle both underdispersed and overdispersed data types. We use the Monte Carlo simulation to compute the required sample size. With our proposed method, a unified model with a low failure risk can be used to cope with the dispersed data type and handle data with many zeros, which appear in groups or clusters sharing a common variation source. A simulation study shows that our proposed method provides accurate results, revealing that the sample size is affected by the distribution skewness, covariance structure of covariates, and amount of zeros. We apply our method to the pancreas disorder length of the stay data collected from Western Australia.

Measurement of the hand-transmitted vibration using a miniature 3-axes accelerometer (초소형 3축 가속도계를 이용한 수전달 진동 측정에 관한 연구)

  • 송치문;장한기;김승한;채장범
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1043-1047
    • /
    • 2003
  • Most of the measurement and the evaluation of hand-transmitted vibration have been performed by using a small size single axis accelerometer between the handle and the hand palm or a three axis accelerometer attached on an adapter outside the hand(indirect measurement). It is most desirable for the correct evaluation of hand-transmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm in the three axis(direct measurement) as recommended in ISO 5349-1. In the study three axes acceleration measurement device was developed of which the thickness was less than 7mm so that it can be placed between the handle and the palm without any inconvenience during the measurement. To verify the performance of the developed device, measured acceleration by the two methods, direct and indirect, were compared in the study.

  • PDF

Ergonomic Factors Assessment on Hand Tool Handle (수공구 손잡이의 인간공학적 요소 평가)

  • Yang Sung-Hwan;Cho Mun-Son;Kang Young-Sig
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • The goal of this study is to investigate the ergonomic factors in designing or selecting the hand tool handle. Electromyogram (EMG) were measured for various wrist postures and handle sizes under two loading conditions. Anthropometric data were measured and the correlation with EMG measurement data were analyzed. Investigations of this study show that wrist posture should be neutral for minimum muscle tension and optimum handle size can be found by measuring the EMG measurement data. It show that hand width and EMG measurement data is greatly correlated also. This study can be a guide of designing or selecting a hand tool, but further study with large sample sizes and various groups is needed for making general conclusion.

Determination of the Optimal Handle Position for Cartons through the Evaluation of Youth User's Preferences (청년층 사용자 선호도 평가를 통한 박스손잡이의 최적위치 설정)

  • Jung, In-Ju;Jung, Hwa-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.49-56
    • /
    • 2007
  • Handles on objects are very important to increase the safety and efficiency of manual handling of people who use them. In this study, four different prototype cartons combined with auxiliary handles were designed to determine the optimal handle position of cartons through the evaluation of user preferences. Twenty male students are participated in the experiment. Likert-5 point summated rating method was applied to evaluate the user preferences for provided handles of the carton among upper, middle, and lower position under the four different sizes and materials handling conditions(carrying positions). The results show that the subjects preferred upper part of the handle on the small cartons regardless of the carrying positions while upper and middle parts of the handle on the big cartons for handling above the waist height were preferred. An optimal handle position depending on the different sizes of carton and the different carrying positions were recommended based on the results of evaluation. It is thus recommended that the cartons provide handles on its relevant position depending on the size and materials handling condition to reduce the musculoskeletal stress and in turn to increase the user satisfaction.

Robust Estimator of Location Parameter

  • Park, Dongryeon
    • Communications for Statistical Applications and Methods
    • /
    • v.11 no.1
    • /
    • pp.153-160
    • /
    • 2004
  • In recent years, the size of data set which we usually handle is enormous, so a lot of outliers could be included in data set. Therefore the robust procedures that automatically handle outliers become very importance issue. We consider the robust estimation problem of location parameter in the univariate case. In this paper, we propose a new method for defining robustness weights for the weighted mean based on the median distance of observations and compare its performance with several existing robust estimators by a simulation study. It turns out that the proposed method is very competitive.

A Study on the Handles of Clay Cups by Studio Potters (도자기 컵 손잡이에 관한 연구 - 도예공방 생산 수제 컵 손잡이 중심으로 -)

  • Lee, Chi-Youn
    • Archives of design research
    • /
    • v.19 no.1 s.63
    • /
    • pp.293-302
    • /
    • 2006
  • clay cups with handles made in studios in Korea and the United States were selected and analyzed. The shape of cup were fixed to ensure proper comparison between handle size of the cup and position. The variable factors were the thickness of the handle, the number of fingers required to hold the cup, the relationship between the handle's shape and the position of its attachment to the cup, the effect of the handle's setter, the change in shape of the handle's thickness, and the relationship between the cup's weight center and handle. Preference test were designed and tested to the users, and the results were analyzed. The results showed that to make a comfortable handle, it is important to incorporate the shape of the resting hand in the design of the handle. Specifically, the design should be such that the cup can be held comfortably. This is possible if the weight of the cup is spread evenly when several fingers are inside the handle's curve and if such factors as the hand size, the curve of the fingers, and the position that best controls the cup's weight center are carefully considered. At this time, if there is a setter for the thumb, a cup of the same weight can be lifted more lightly. In the design of such a cup, the oval line is drawn by extending the cup's handle toward the direction of the cup's body. If the cup's weight center is located on the oval line, the cup's handle may be said to be effective. In such a case, the nearer the handle is to the cup's body weight center, the less power is needed to lift the cup efficiently. Our test results can be applied as a powerful tools in design and manufacturing cups with handle in terms of artistry and functionality.

  • PDF

A production rescheduling system for a large size parallel machine flow shop (대규모 병렬기계 흐름생산의 재일정계획)

  • Chung, Nam-Kee;Yoo, Chul-Soo;Kim, Jong-Min;Choi, Jeong-Gil
    • IE interfaces
    • /
    • v.9 no.2
    • /
    • pp.75-82
    • /
    • 1996
  • A scheduling system is developed for a parallel machine flow shop which reflects the situations of the manufacturing processes in the tire industry. The schedule is generated via simulation using heuristic rules to get satisfaction on such constraints as due dates, demands, work-in-process, process capacity, set-up times and scheduling speed. This system, constructed with relational DB, SQL and C language, consumes less than 10 minutes of PC simulation to handle real size problems.

  • PDF

Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy (자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광)

  • 문치웅;조경식
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF