• Title/Summary/Keyword: Hand defect

Search Result 218, Processing Time 0.026 seconds

Reconstruction of a Circumferential Penile Shaft Defect Using Bilateral Superficial External Pudendal Artery Perforator Flaps (양측 천외음부동맥 천공지 피판을 이용한 음경둘레 연조직 결손의 재건)

  • Park, Jongohk;Shin, Donghyeok;Choi, Hyungon;Kim, Jeenam;Lee, Myungchul
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.296-300
    • /
    • 2018
  • Penile shaft reconstruction requires adequate soft tissue characteristics as well as constant vascular pedicles when considering a perforator flap. The free flap technique using various donor sites and regional conventional and perforator flaps have been utilized for penile shaft reconstruction. Still, the free flap techniques include challenging surgical procedures in addition to postoperative management. The regional flap can be applied to limited defects due to the size and shape. We performed the bilateral superficial external pudendal artery (SEPA) perforator flaps in order to reconstruct a circumferential penile shaft defect. The circumferential wound has noted necrotic tissue involving superficial (Dartos) fascia. We underwent debridement, preserving deep (Buck's) fascia and corpus spongiosum. Thereafter, the soft tissue defect was covered with bilateral SEPA perforator flaps. The patient has been observed for 27 months, showing penile resilience without deformity or wound-related problems.

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.

Oblique Axis Hypothenar Free Flaps: Tips for Harvesting Larger Flaps with Minimal Donor Site Morbidity

  • Sang Ho Oh;Jae In Chung
    • Archives of Plastic Surgery
    • /
    • v.50 no.3
    • /
    • pp.279-287
    • /
    • 2023
  • Background Hypothenar free flaps (HTFFs) have been widely used for reconstructing palmar defects. Although previous anatomical and clinical studies of HTFF have been conducted, this technique still has some limitations. In this study, we describe some tips for large flap design that allows for easy harvesting of HTFFs with minimal donor site morbidity. Methods A total of 14 HTFF for hand defect reconstruction were recorded. The oblique flap was designed in the proximal HT area following relaxed skin tension line along the axis between fourth web space and 10 mm ulnar side of pisiform. A flap pedicle includes one or two perforators with ulnar digital artery and HT branch of basilic vein. In addition, innervated HTFF can be harvested with a branch of ulnar digital nerve. Electronic medical records were reviewed to obtain data on patients' information, operative details, and follow-up period. In addition, surgical outcome score was obtained from the patient, up to 10 points, at the last follow-up. Results Mean harvest time was 46 minutes, and two perforators were included in 10 cases. The mean flap area was 10.84 cm2. There were no problems such as donor site depression, scar contracture, keloids, wound dehiscence, numbness or neuroma pain at donor sites, and hypersensitivity or cold intolerance at flap site, either functionally or aesthetically. Conclusion Palmar defect reconstruction is challenging for hand surgeons. However, large HTFF can be harvested without complications using the oblique axis HTFF technique. We believe our surgical tips increase utility of HTFF for palmar defect reconstruction.

Methods for Improving Hand-off of Different Generations in CDMA Mobile Communications

  • Choi, Dong-You;Park, Chang-Kyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2E
    • /
    • pp.91-97
    • /
    • 2002
  • One of the most important things in mobile phone service is Hand-Off (H/O). Meantime soft H/O and softer H/O have been used between the same generations (2G↔2G) and there is little problem. With user's needs and the development of communication technology, the system with different generation coexists and pilot beacon and time-periodic beacon are used for H/O between generations (2.5G↔2G) to start service, but it is not economic and efficient. To improve such problems, ENHHO developed in April 2001 has recently used. Unfortunately, this method also has the defect of momentary cutoff of communication information during the procedure of H/O in case of more than 5 pilot signals. Accordingly, we suggest algorithm to improve the problem of ENHHO and examines its propriety by analyzing the results of field survey using the algorithm.

Color Analysis of Forehead Flap and Full Thickness Skin Graft in Facial Reconstruction (이마피판술과 후이개부 전층피부이식술을 이용한 안면부 연부조직결손 재건 후 피부 색상의 비교)

  • Cho, Sung Hoo;Yoo, Sung In;Noh, Bok Kyun;Kim, Eui Sik;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Purpose: For facial reconstruction, skin color match is crucial to achieve great aesthetic result. Forehead flap and full thickness skin graft have been used for many years to reconstruct facial defect. Their results are aesthetically valuable with remarkable resemblance and harmony of the skin color between donor and recipient sites. The purpose of this study is to evaluate and compare the aesthetic outcome of the two methods as the analysis of skin color match. Methods: From January 1995 to December 2005, ten forehead flaps and ten full thickness skin grafts were performed. The reconstructed areas of forehead flaps were five noses and five eyelids. Recipient sites of full thickness skin grafts were seven eyelids, two noses and one forehead. In order to obtain the objective validity, the skin color of flap(or graft) and the recipient sites were measured by chromameter. The skin colors were quantified according to a three-dimensional coordinate system used in chromameter, L*(brightness), a*(redness), and b*(yellowness).Results: There was no significant color difference between forehead flap site and adjacent skin in all color values. On the other hand, the L* and b* values of graft sites were significantly lower than those of the adjacent skins. The a* values of graft sites were higher than those of the adjacent skins. Conclusion: This study reveals that skin color match of forehead flap is greater than that of full thickness skin graft. As forehead flap has adequate volume and great color match, it can be useful to reconstruct deep facial defect such as nasal defect. On the other hand, full thickness skin graft can be used for superficial defect like partial eyelid defect.

Tourniquet-Free Hand Surgery Using the One-per-Mil Tumescent Technique

  • Prasetyono, Theddeus O.H.
    • Archives of Plastic Surgery
    • /
    • v.40 no.2
    • /
    • pp.129-133
    • /
    • 2013
  • Background A pneumatic tourniquet is generally used to achieve a bloodless operation field in hand surgery. However, this has changed with tumescent solution-based wide-awake surgery. This study is a preliminary prospective case series study to elaborate the formula and indications of the tumescent technique in hand surgery without a tourniquet. Methods Seven patients (age range, 4 months to 37 years) underwent hand or upper extremity surgery for conditions such as nerve palsy, electric burn defect, fingertip injury, contracture, constriction ring syndrome, or acrosyndactyly. A "one-per-mil" tumescent solution (epinephrine 1:1,000,000+20 mg lidocaine/50 mL saline) was used to create a bloodless operating field without a tourniquet. Observation was performed to document the amount of solution injected, the operation field clarity, and the postoperative pain. Results The "one per mil" epinephrine solution showed an effective hemostatic effect. The tumescent technique resulted in an almost bloodless operation field in the tendon and in the constriction ring syndrome surgeries, minimal bleeding in the flap and contracture release surgeries, and acceptable bleeding in acrosyndactyly surgery. The amount of solution injected ranged from 5.3 to 60 mL. No patient expressed significant postoperative pain. Flap surgeries showed mixed results. One flap was lost, while the others survived. Conclusions Epinephrine 1:1,000,000 in saline solution is a potential replacement for a tourniquet in hand surgery. Further studies are needed to delineate its safety for flap survival.

Updated Surgical Techniques and Expanded Indications of Free Vascularized Fibular Graft

  • Park, Jong Woong
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.2
    • /
    • pp.41-49
    • /
    • 2015
  • Free or pedicled vascularized fibular grafts (VFG) are useful for the reconstruction of large skeletal defects, particularly in cases of scarred or avascular beds, or in patients with combined bone and soft tissue defects. Compared to non-VFG, VEG, which contains living osteocytes and osteoblasts, maintains its own viability and serves as good osteoconductive and osteoinductive graft. Due to its many structural and biological advantages, the free fibular osteo- or osteocutaneous graft is considered the most suitable autograft for the reconstruction of long bone defects in the injured extremity. The traditional indication of VFG is the long bone and soft tissue defect, which cannot be reconstructed using a conventional operative method. Recently, the indications have been widely expanded not only for defects of midtibia, humerus, forearm, distal femur, and proximal tibia, but also for the arthrodesis of shoulder and knee joints. Because of its potential to allow further bone growth, free fibular epiphyseal transfer can be used for the hip or for distal radius defects caused by the radical resection of a tumor. The basic anatomy and surgical techniques for harvesting the VFG are well known; however, the condition of the recipient site is different in each case. Therefore, careful preoperative surgical planning should be customized in every patient. In this review, recently expanded surgical indications of VFG and surgical tips based on the author's experiences in the issues of fixation method, one or two staged reconstruction, size mismatching, overcoming the stress fracture, and arthrodesis of shoulder and knee joint using VFG are discussed with the review of literature.

Effect of δ-Ferrite on the Hot Workability and Surface Defect of STS 304 Billets Containing 3 wt. % Cu (3 wt.% Cu 함유 STS 304 빌렛의 열간가공성과 표면결합에 미치는 δ-ferrite의 영향)

  • Kim, S.W.
    • Korean Journal of Materials Research
    • /
    • v.14 no.6
    • /
    • pp.379-388
    • /
    • 2004
  • To investigate the effect of D-ferrite on the hot workability and surface defect of STS 304 billets containing 3 wt. % Cu, microstructure observations and high temperature mechanical properties test were carried out for the specimens extracted mainly from raw or oxidized billets. It was found that the total $\delta$-ferrite content has little influence on the hot workability, even though the fracture cracks due to high temperature tension or compression test were initiated and propagated mostly along $\delta$/${\gamma}$ boundary in the specimens. On the other hand, it was supposed that the direct causes of surface defects in the wire rolled from the as-continuously cast billet were the grain boundary embrittlement arose from the deep diffusion of oxygen into the grain boundary, and the oxidation of $\delta$-ferrite connected by a grain boundary to the surface during the billet reheating process as well.

Effect of pressure and temperature on bulk micro defect and denuded zone in nitrogen ambient furnace

  • Choi, Young-Kyu;Jeong, Se-Young;Sim, Bok-Cheol
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.3
    • /
    • pp.121-125
    • /
    • 2016
  • The effect of temperature and pressure in the nitrogen ambient furnace on bulk micro defect (BMD) and denuded zone (Dz) is experimentally investigated. It is found that as pressure increases, Dz depth increases with a small decrease of BMD density in the range of temperature, $100{\sim}300^{\circ}C$. BMD density with hot isostatic pressure treatment (HIP) at temperature of $850^{\circ}C$ is higher than that without HIP while Dz depth is lower due to much higher BMD density. As the pressure increases, BMD density is increased and saturated to a critical value, and Dz depth increases even if BMD density is saturated. The concentration of nitrogen increases near the surface with increasing pressure, and the peak of the concentration moves closer to the surface. The nitrogen is gathered near the surface, and does not become in-diffusion to the bulk of the wafer. The silicon nitride layer near the surface prevents to inject the additional nitrogen into the bulk of the wafer across the layer. The nitrogen does not affect the formation of BMD. On the other hand, the oxygen is moved into the bulk of the wafer by increasing pressure. Dz depth from the surface is extended into the bulk because the nuclei of BMD move into the bulk of the wafer.

Complications of endoscopic resection in the upper gastrointestinal tract

  • Takeshi Uozumi;Seiichiro Abe;Mai Ego Makiguchi;Satoru Nonaka;Haruhisa Suzuki;Shigetaka Yoshinaga;Yutaka Saito
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.409-422
    • /
    • 2023
  • Endoscopic resection (ER) is widely utilized as a minimally invasive treatment for upper gastrointestinal tumors; however, complications could occur during and after the procedure. Post-ER mucosal defect leads to delayed perforation and bleeding; therefore, endoscopic closure methods (endoscopic hand-suturing, the endoloop and endoclip closure method, and over-the-scope clip method) and tissue shielding methods (polyglycolic acid sheets and fibrin glue) are developed to prevent these complications. During duodenal ER, complete closure of the mucosal defect significantly reduces delayed bleeding and should be performed. An extensive mucosal defect that comprises three-quarters of the circumference in the esophagus, gastric antrum, or cardia is a significant risk factor for post-ER stricture. Steroid therapy is considered the first-line option for the prevention of esophageal stricture, but its efficacy for gastric stricture remains unclear. Methods for the prevention and management of ER-related complications in the esophagus, stomach, and duodenum differ according to the organ; therefore, endoscopists should be familiar with ways of preventing and managing organ-specific complications.