• 제목/요약/키워드: Hand defect

검색결과 219건 처리시간 0.023초

Reconstruction of Hand Dorsum Defect Using Double Perforators-Based Anterior Interosseous Artery Island Flap: A Case Report and Description of a New Anterior Interosseous Artery Perforator

  • Inho Kang;Hyun Rok Lee;Gyu Yong Jung;Joon Ho Lee
    • Archives of Plastic Surgery
    • /
    • 제50권4호
    • /
    • pp.409-414
    • /
    • 2023
  • The anterior interosseous artery (AIA) perforator flap is not commonly used in hand dorsum reconstruction compared with alternatives. However, it is a versatile flap with several advantages. Literature on the AIA perforator flap is based on the dorsal septocutaneous branch (DSB), which branches from the AIA and passes through fascia between the extensor pollicis longus (EPL) and extensor pollicis brevis muscles. In the described case, the authors reconstructed a hand dorsum defect in a 78-year-old man using an AIA perforator flap with double perforators supplied by the DSB and a new perforator branching from the distal than DSB. No complication was encountered, and the flap survived completely. A retrospective computed tomography review revealed the presence of the new perforator in 14 of 21 patients. Two types of new perforator were observed. One passed through the ulnar side of the extensor indicis proprius (EIP) muscle and penetrated fascia between the extensor digitorum minimi and extensor digitorum communis tendons, whereas the other passed between the EPL and EIP muscles. This report describes the anatomical location and clinical application of the new AIA perforators. The double perforators-based AIA flap provides a straightforward, reliable means of reconstructing hand dorsum defects.

알루미늄 합금재의 피로크랙 전파거동에 미치는 미소원공결함 (The Influence of the Small Circular Hole Defect on the Fatigue Crack Propagation Behavior in Aluminum Alloys)

  • 김건호;이호연
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.834-840
    • /
    • 2008
  • We carried out fatigue testing with materials of aluminum alloyC7075-T6, 2024-T4) by rotary bending fatigue tester. We investigated fatigue limit, fatigue crack initiation, fatigue crack propagation behavior and possibility of fatigue life prediction to the different small circular hole defect. The summarized result are as follows; Fatigue limit of the smooth specimens were related tensile strength and yield strength. In case of more large applied stress and small circular hole crack defect, the fatigue crack was grown rapidly. The fatigue crack propagation behavior proceed at according to inclusion. Fatigue crack propagation ratio appeared instability and retardation phenomenon in the first half of fatigue life but appeared stability and replied in the latter half. On other hand, this experimental data of the materials are appeared fatigue life predictability.

다채널 진동 센서를 이용한 선박 엔진의 진동 감지 및 고장 분류 시스템 (Defect Detection and Defect Classification System for Ship Engine using Multi-Channel Vibration Sensor)

  • 이양민;이광용;배승현;장휘;이재기
    • 정보처리학회논문지A
    • /
    • 제17A권2호
    • /
    • pp.81-92
    • /
    • 2010
  • 진동 정보를 통해 기계 설비의 상태나 고장 유무를 판단하는 연구들이 다수 진행 중에 있는데, 대부분의 연구에서는 설비에 대한 진동을 모니터링하거나 고장 유무를 판별하여 사용자에게 알리는 수준이다. 본 논문에서는 진동에 의한 고장 진단과 판별을 보다 정교하게 수행하는 선박 엔진의 고장 감지 기법과 시스템을 제안하였다. 일차적으로 이중적 진동 정보 판별 기법을 적용하여 진동 정보를 확인한 다음에 고장 유무를 검사한다. 만일 고장이 발생한 경우에는 진동 정보의 오류 부분만을 이용하여 고장 진동 파형에 대한 오차 범위를 기준으로 어떤 유형의 고장인지를 판별할 수 있는 기법을 적용하였다. 또한 선박의 진동 경향 분석과 엔진 안전 보존을 목적으로 진동 정보를 데이터베이스에 저장하고 추적할 수 있도록 시스템을 구현하였다. 제안 시스템을 선박 엔진의 고장 판별 유무와 고장 진동 파형 감별 인자에 대해 실험을 수행한 결과 고장 유무 판별은 약 100% 정확성을 가졌고 고장 진동 파형의 유형 인식에서는 약 96% 정확성을 가졌다.

얕은 지방층을 포함한 피부복합조직이식을 이용한 손화상 반흔구축의 교정 (Preserved Superficial Fat Skin Composite Graft for Correction of Burn Scar Contracture of Hand)

  • 손대구;정회준;최태현;김준형;한기환
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.716-722
    • /
    • 2008
  • Purpose: Split or full thickness skin graft is generally used to reconstruct the palmar skin and soft tissue defect after release of burn scar flexion contracture of hand. As a way to overcome and improve aesthetic and functional problems, the authors used the preserved superficial fat skin(PSFS) composite graft for correction of burn scar contracture of hand. Methods: From December of 2001 to July of 2007, thirty patients with burn scar contracture of hand were corrected. The palmar skin and soft tissue defect after release of burn scar contracture was reconstructed with the PSFS composite graft harvested from medial foot or below lateral and medial malleolus, with a preserved superficial fat layer. To promote take of the PSFS composite graft, a foam and polyurethane film dressing was used to maintain the moisture environment and Kirschner wire was inserted for immobilization. Before and after the surgery, a range of motion was measured by graduator. Using a chromameter, skin color difference between the PSFS composite graft and surrounding normal skin was measured and compared with full thickness skin graft from groin. Results: In all cases, the PSFS composite graft was well taken without necrosis, although the graft was as big as $330mm^2$(mean $150mm^2$). Contracture of hand was completely corrected without recurrence. The PSFS composite graft showed more correlations and harmonies with surrounding normal skin and less pigmentation than full thickness skin graft. Donor site scar was also obscure. Conclusion: The PSFS composite graft should be considered as a useful option for correction of burn scar flexion contracture of hand.

Investigation of a pre-clinical mandibular bone notch defect model in miniature pigs: clinical computed tomography, micro-computed tomography, and histological evaluation

  • Carlisle, Patricia L.;Guda, Teja;Silliman, David T.;Lien, Wen;Hale, Robert G.;Baer, Pamela R. Brown
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권1호
    • /
    • pp.20-30
    • /
    • 2016
  • Objectives: To validate a critical-size mandibular bone defect model in miniature pigs. Materials and Methods: Bilateral notch defects were produced in the mandible of dentally mature miniature pigs. The right mandibular defect remained untreated while the left defect received an autograft. Bone healing was evaluated by computed tomography (CT) at 4 and 16 weeks, and by micro-CT and non-decalcified histology at 16 weeks. Results: In both the untreated and autograft treated groups, mineralized tissue volume was reduced significantly at 4 weeks post-surgery, but was comparable to the pre-surgery levels after 16 weeks. After 16 weeks, CT analysis indicated that significantly greater bone was regenerated in the autograft treated defect than in the untreated defect (P=0.013). Regardless of the treatment, the cortical bone was superior to the defect remodeled over 16 weeks to compensate for the notch defect. Conclusion: The presence of considerable bone healing in both treated and untreated groups suggests that this model is inadequate as a critical-size defect. Despite healing and adaptation, the original bone geometry and quality of the pre-injured mandible was not obtained. On the other hand, this model is justified for evaluating accelerated healing and mitigating the bone remodeling response, which are both important considerations for dental implant restorations.

전외측대퇴근막 유리피판술을 이용한 수부의 재건 (Reconstruction of hand using anterolateral thigh fascial free flap)

  • 김기완;김진수;이동철;기세휘;노시영;양재원
    • Archives of Plastic Surgery
    • /
    • 제36권5호
    • /
    • pp.571-577
    • /
    • 2009
  • Purpose: The Provision of thin and pliable tissue and the adequate coverage of tendon - gliding surface is necessary for a soft tissue defect of the hand with exposure of bone, tendon and muscle. This report will discuss our experience with anterolateral thigh fascial free flap for the reconstruction of the soft tissue defect of the hand. Methods: Between February 2004 and August 2008, seven patients with full - thickness soft tissue defects of the hand were reconstructed by means of a composite anterolateral thigh fascial free flap. There were soft tissue defects associated with trauma (n=5), scar contracture (n=1) and necrosis due to ischemia (n=1). Flaps were harvested from the anterolateral thigh as adipofascial flaps with only a small sheet of fascia and fatty tissue above it. The fascia and the skin of the donor site was closed directly and delayed split - thickness skin graft was performed. Result: All flaps survived completely. The size of the transferred flap ranged from $2{\times}4cm$ to $5{\times}8cm$. Thin flap coverage was possible without secondary debulking operations. It left minimal donor site morbidity with a linear scar. In one case, the thigh muscle herniation in the donor site was developed. Conclusion: The anterolateral thigh fascial free flap provided thin and pliable tissue which can establish a tendon - gliding mechanism, minimal bulk, minimal donor site morbidity. The disadvantages of this technique were the need for a skin graft and the muscle herniation of donor site.

역행성 후 골간 동맥 피판을 이용한 수부결손의 재건 (Reconstruction of Hand Defects with Reverse Posterior Interosseous Artery Flaps)

  • 서영석;박형택;이군식
    • Archives of Reconstructive Microsurgery
    • /
    • 제10권2호
    • /
    • pp.149-153
    • /
    • 2001
  • Various types of flaps including local flaps, pedicle flaps and free flap have been used to reconstruct hand soft tissue defects, but each flaps have some limitation and disadvantages. The reverse posterior interosseous artery flap described by Zancolli and Angrigiani have some advantages : preserving the major artery of the hand, minimal donor site morbidity and thin skin. From May 1999 to May 2001, we reconstructed 18 cases of hand defects in industrial injury with reverse posterior interosseous artery flaps and partial distal part necrosis of flaps due to infection developed in a case but other 17 cases survived completely without any specific complication.

  • PDF

큐렛팁을 장착한 압전방식 초음파치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구 (The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Casting Gold Removal in Vitro)

  • 이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제31권3호
    • /
    • pp.531-542
    • /
    • 2001
  • Periodontal debridement is most important procedure in periodontal treatment, because periodontal disease is the biofilm infection. The use of ultrasonic instrument has many clinical advantages compared to classical hand instrument. The introduction of newly developed ultrasonic scaler tips made the use of ultrasonic scaler popular. However the study of tooth substance removal according to the working parameters of ultrasonic scaler with newly developed tips is not sufficient. The purpose of this study is to evaluate the effects of working parameters of piezoelectric ultrasonic scaler with curette tip on casting gold removal. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1.0 N, 2.0 N) and power setting was adjusted 2, 4, 8 in P mode and S mode and instrumentation time was 5 seconds. The defect depth and width were measured with profile meter and defect surface was examined by SME. The depth of defect was significantly large in S mode( $39.58{\pm}19.35{\mu}m$) compared to P mode( $8.37{\pm}6.98{\mu}m$). There was significant decrease of depth of defect between 1.0N($32.87{\pm}27.18{\mu}m$) and 2.0N( $14.86{\pm}15.04{\mu}m$). The area of defect was also significantly large in S mode($4482.42{\pm}3551.71{\mu}m^2$) compared to P mode( $922.06{\pm}960.32{\mu}m^2$). There was significant decrease of area of defect between 1.0N($3889.12{\pm}3936.00{\mu}m$) and 2.0N( $974.66{\pm}986.01{\mu}m$). The change of mode did not effect on the width of the defect. The change of power setting did not effect on the depth, width, and area of defect. In spite of limitation of this study it could be concluded that the use of piezoelectric ultrasonic scaler with curette tip on S mode could make significant tooth substance loss.

  • PDF

도플러 넓어짐 스펙트럼을 이용한 희토류 증감지 결함 특성 (The Defect Characterization of Rare-earth Intensifying Screen Material by Doppler Broadening Positron Annihilation Spectrometer)

  • 이종용;김창규;송기영;김재홍
    • 한국재료학회지
    • /
    • 제15권6호
    • /
    • pp.370-374
    • /
    • 2005
  • Doppler broadening spectrometer for positron annihilation experiment(DBPAS) has been used to characterize nano size defect structures in materials. DBPAS measures the concentration, spatial distribution, and size of open volume defects in the rare-earth intensifying screen materials. The screens were exposed by X-ray varying the exposed doses from 3, 6, 9, and 12 Gy with 6 W and 15 MV respectively and also irradiated by 37 MeV proton beams ranging from 0 to $10^{12}ptls$. The S parameter values increased as the exposed time and the energies increased, which indicated the defects were generated more. The S parameters of the samples with X-rays varied from 0.5098 to 0.5108, on the other hand, as proton beams varied from 0.4804 to 0.4821.

삼심방증 치험 2례 (Cor Triatrium; A Classic Type and a Type Combibed with Atrial Septal Defect; Report of Two Cases)

  • 손제문
    • Journal of Chest Surgery
    • /
    • 제26권7호
    • /
    • pp.543-547
    • /
    • 1993
  • Cor triatriatum is a rare entity of congenital heart disease characterized by the presence of a fibrousmuscular diaphragm that subdivides the left atrium into a proximal or "accessory" chamber and a distal or "true" left atrial chamber. In the other hand, cor triatriatum is a variant of abnormal connection between the pulmonary vein and true left atrium which is separated from accessory left atrium receiving pulmonary venous blood flow by fibromuscular diaphragm. We experienced two cases of cor triatriatum. One of them was classical, and the other case was combined with atrial septal defect and all pulmonary veins were drained into the " common pulmonary venous chamber " which connected with right atrium and there was no direct communication between the accessory chamber and true left atrium. The abnormal diaphragms were excised and the atrial septal defect was repaired with pericardial patch in case II. The postoperative courses were not eventful and the patients were discharged with good result, and have been in good condition upto now.n good condition upto now.

  • PDF