• 제목/요약/키워드: Hand defect

검색결과 219건 처리시간 0.028초

Soft Tissue Reconstruction of Complete Circumferential Defects of the Upper Extremity

  • Ng, Zhi Yang;Tan, Shaun Shi Yan;Lellouch, Alexandre Gaston;Cetrulo, Curtis Lisante Jr;Chim, Harvey Wei Ming
    • Archives of Plastic Surgery
    • /
    • 제44권2호
    • /
    • pp.117-123
    • /
    • 2017
  • Background Upper extremity soft tissue defects with complete circumferential involvement are not common. Coupled with the unique anatomy of the upper extremity, the underlying etiology of such circumferential soft tissue defects represent additional reconstructive challenges that require treatment to be tailored to both the patient and the wound. The aim of this study is to review the various options for soft tissue reconstruction of complete circumferential defects in the upper extremity. Methods A literature review of PubMed and MEDLINE up to December 2016 was performed. The current study focuses on forearm and arm defects from the level at or proximal to the wrist and were assessed based on Tajima's classification (J Trauma 1974). Data reviewed for analysis included patient demographics, causality, defect size, reconstructive technique(s) employed, and postoperative follow-up and functional outcomes (when available). Results In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, 14 unique articles were identified for a total of 50 patients (mean=28.1 years). Underlying etiologies varied from extensive thermal or electrical burns to high impact trauma leading to degloving or avulsion, crush injuries, or even occur iatrogenically after tumor extirpation or extensive debridement. Treatment options ranged from the application of negative pressure wound dressings to the opposite end of the spectrum in hand transplantation. Conclusions With the evolution of reconstructive techniques over time, the extent of functional and aesthetic rehabilitation of these complex upper extremity injuries has also improved. The proposed management algorithm comprehensively addresses the inherent challenges associated with these complex cases.

Prognosis of Full-Thickness Skin Defects in Premature Infants

  • Moon, Hyung Suk;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • 제39권5호
    • /
    • pp.463-468
    • /
    • 2012
  • Background In the extremities of premature infants, the skin and subcutaneous tissue are very pliable due to immaturity and have a greater degree of skin laxity and mobility. Thus, we can expect wounds to heal rapidly by wound contraction. This study investigates wound healing of full-thickness defects in premature infant extremities. Methods The study consisted of 13 premature infants who had a total of 14 cases of full-thickness skin defects of the extremities due to extravasation after total parenteral nutrition. The wound was managed with intensive moist dressings with antibiotic and anti-inflammatory agents. After wound closure, moisturization and mild compression were performed. Results Most of the full-thickness defects in the premature infants were closed by wound contraction without granulation tissue formation on the wound bed. The defects resulted in 3 pinpoint scars, 9 linear scars, and 2 round hypertrophic scars. The wounds with less granulation tissue were healed by contraction and resulted in linear scars parallel to the relaxed skin tension line. The wounds with more granulation tissue resulted in round scars. There was mild contracture without functional abnormality in 3 cases with a defect over two thirds of the longitudinal length of the dorsum of the hand or foot. The patients' parents were satisfied with the outcomes in 12 of 14 cases. Conclusions Full-thickness skin defects in premature infants typically heal by wound contraction with minimal granulation tissue and scar formation probably due to excellent skin mobility.

Innervated Cross-Finger Pulp Flap for Reconstruction of the Fingertip

  • Lee, Nae-Ho;Pae, Woo-Sik;Roh, Si-Gyun;Oh, Kwang-Jin;Bae, Chung-Sang;Yang, Kyung-Moo
    • Archives of Plastic Surgery
    • /
    • 제39권6호
    • /
    • pp.637-642
    • /
    • 2012
  • Background Fingertip injuries involving subtotal or total loss of the digital pulp are common types of hand injuries and require reconstruction that is able to provide stable padding and sensory recovery. There are various techniques used for reconstruction of fingertip injuries, but the most effective method is functionally and aesthetically controversial. Despite some disadvantages, cross-finger pulp flap is a relatively simple procedure without significant complications or requiring special techniques. Methods This study included 90 patients with fingertip defects who underwent cross-finger pulp flap between September 1998 and March 2010. In 69 cases, neurorrhaphy was performed between the pulp branch from the proper digital nerve and the recipient's sensory nerve for good sensibility of the injured fingertip. In order to evaluate the outcome of our surgical method, we observed two-point discrimination in the early (3 months) and late (12 to 40 months) postoperative periods. Results Most of the cases had cosmetically and functionally acceptable outcomes. The average defect size was $1.7{\times}1.5$ cm. Sensory return began 3 months after flap application. The two-point discrimination was measured at 4.6 mm (range, 3 to 6 mm) in our method and 7.2 mm (range, 4 to 9 mm) in non-innervated cross-finger pulp flaps. Conclusions The innervated cross-finger pulp flap is a safe and reliable procedure for lateral oblique, volar oblique, and transverse fingertip amputations. Our procedure is simple to perform under local anesthesia, and is able to provide both mechanical stability and sensory recovery. We recommend this method for reconstruction of fingertip injuries.

전교통동맥 모형을 이용한 자기공명혈관촬영술의 신호 불균일에 관한 실험적 연구 (An Experimental Study on the Cause of Signal Inhomogeneity for Magnetic Resonance Angiography Using Phantom Model of Anterior Communicating(A-com) Artery)

  • 유병규;정태섭
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권1호
    • /
    • pp.55-62
    • /
    • 2002
  • Aneurysm-mimicking findings were frequently visualized due to hemodynamical causes of dephasing effects around area of A-com artery during magnetic resonance angiography(MRA) and these kind of phenomena have not been clearly known yet. We investigated the hemodynamical patterns of dephasing effect around area of the A-com artery that might be a cause of false intracranial aneurysms on MRA. For experimental study, We used hand-made silicon phantoms of the asymmetric A-com artery as like a bifurcation configuration. In a closed circulatory system with UHDC computer driven cardiac pump system. MRA and fast digital subfraction angiography(DSA) involved the use of these phantoms. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF) and DSA of Phantoms constructed from an automated closed-type circulatory system filled with glycerol solution [circulation fluid(glycerol:water = 1:1.4)]. These findings were then compared with those obtained from computational fluid dynamic(CFD) for inter-experimental correlation study. Imaging findings of MRA, DSA and CFD on inflow zone according to the following: a) MRA demonstrated high signal intensity zone as inflow zone on silicon phantom; b) Patterns of DSA were well matched with MRA on trajectory of inflow zone; and c) CFD were well matched with MRA on the pattern of main flow. Imaging findings of MRA. DSA and CFD on turbulent flow zone according to the following: a) MRA demonstrated hyposignal intensity zone at shoulder and axillar zone of main inflow; b) DSA delineated prominent vortex flow at the same area. The hemodynamical causes of signal defect, which could Induce the false aneurysm on MRA, turned out to be dephasing effects at axilla area of bifurcation from turbulent flow as the results of MRA, DSA and CFD.

  • PDF

결정질 실리콘 태양전지의 패시베이션 적용을 위한 Al2O3/SiON 적층구조의 열적 안정성에 대한 연구 (A Study on the Thermal Stability of an Al2O3/SiON Stack Structure for c-Si Solar Cell Passivation Application)

  • 조국현;장효식
    • 한국세라믹학회지
    • /
    • 제51권3호
    • /
    • pp.197-200
    • /
    • 2014
  • We investigated the influence of blistering on $Al_2O_3$/SiON stacks and $Al_2O_3$/SiNx:H stacks passivation layers. $Al_2O_3$ film provides outstanding Si surface passivation quality. $Al_2O_3$ film as the rear passivation layer of a p-type Si solar cell is usually stacked with a capping layer, such as $SiO_2$, SiNx, and SiON films. These capping layers protect the thin $Al_2O_3$ layer from an Al electrode during the annealing process. We compared $Al_2O_3$/SiON stacks and $Al_2O_3$/SiNx:H stacks through surface morphology and minority carrier lifetime after annealing processes at $450^{\circ}C$ and $850^{\circ}C$. As a result, the $Al_2O_3$/SiON stacks were observed to produce less blister phenomenon than $Al_2O_3$/SiNx:H stacks. This can be explained by the differences in the H species content. In the process of depositing SiNx film, the rich H species in $NH_3$ source are diffused to the $Al_2O_3$ film. On the other hand, less hydrogen diffusion occurs in SiON film as it contains less H species than SiNx film. This blister phenomenon leads to an increase insurface defect density. Consequently, the $Al_2O_3$/SiON stacks had a higher minority carrier lifetime than the $Al_2O_3$/SiNx:H stacks.

열전소자 내부 층간 결함과 열성능 관계에 관한 연구 (Research on the Relationship between Thermoelectric Module with Defects and Thermal Performances)

  • 최철준;고가진;김재열;정윤수
    • 한국기계가공학회지
    • /
    • 제15권4호
    • /
    • pp.125-133
    • /
    • 2016
  • From the first application of a thermoelectric module to nowtoday, it has been more than half a century. The application of a thermoelectric module is becoming more and more widely accepted since, people's requirement rely more and more on the efficiency of thermoelectric modules and their reliability become higher and higher. So people pay more and more attention to the thermoelectric module. In Around the world, the more research for into improving the efficiency of thermoelectric modules is focused on the current materials. at present. However, the research of into available materials had has some limitations, and the research of materials had reached a bottleneckthere are limits to current applications. On the other hand, from the production process, if we assembled by materials withoutmodules without any damages and achieve the ideal state of a joint, we can make the a product to maximize performance and have a longer service life. SoTherefore, in this study we will prove the relationship between the any defects inside and the efficiency of a thermoelectric module to improve the quality management and performance of modern thermoelectric modules at present.

Enhanced pH Response of Solution-gated Graphene FET by Using Vertically Grown ZnO Nanorods on Graphene Channel

  • Kim, B.Y;Jang, M.;Shin, K.-S.;Sohn, I.Y;Kim, S.-W.;Lee, N.-E
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.434.2-434.2
    • /
    • 2014
  • We observe enhanced pH response of solution-gated field-effect transistors (SG-FET) having 1D-2D hybrid channel of vertical grown ZnO nanorods grown on CVD graphene (Gr). In recent years, SG-FET based on Gr has received a lot of attention for biochemical sensing applications, because Gr has outstanding properties such as high sensitivity, low detection limit, label-free electrical detection, and so on. However, low-defect CVD Gr has hardly pH responsive due to lack of hydroxyl group on Gr surface. On the other hand, ZnO, consists of stable wurtzite structure, has attracted much interest due to its unique properties and wide range of applications in optoelectronics, biosensors, medical sciences, etc. Especially, ZnO were easily grown as vertical nanorods by hydrothermal method and ZnO nanostructures have higher sensitivity to environments than planar structures due to plentiful hydroxyl group on their surface. We prepared for ZnO nanorods vertically grown on CVD Gr (ZnO nanorods/Gr hybrid channel) and to fabricate SG-FET subsequently. We have analyzed hybrid channel FETs showing transfer characteristics similar to that of pristine Gr FETs and charge neutrality point (CNP) shifts along proton concentration in solution, which can determine pH level of solution. Hybrid channel SG-FET sensors led to increase in pH sensitivity up to 500%, compared to pristine Gr SG-FET sensors. We confirmed plentiful hydroxyl groups on ZnO nanorod surface interact with protons in solution, which causes shifts of CNP. The morphology and electrical characteristics of hybrid channel SG-FET were characterized by FE-SEM and semiconductor parameter analyzer, respectively. Sensitivity and sensing mechanism of ZnO nanorods/Gr hybrid channel FET will be discussed in detail.

  • PDF

안면부 재건술에서 사용되는 다양한 피판의 색조 비교 (Analysis of Color Difference in Facial Reconstruction used Various Flaps)

  • 박장완;김의식;황재하;김광석;이삼용
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.365-371
    • /
    • 2009
  • Purpose: Good color match holds a key position in facial reconstruction for good aesthetic result. To correct the wide facial soft tissue defect were usually used the tissue expanded cheek flap, deltopectoral flap or radial forearm free flap. This study is aimed to analyse the color difference after flap surgery by using chromameter. Method: From August 1995 to December 2006, 30 patients underwent flap operations were chosen randomly and evaluated color differences between flap site and adjacent skin. Reconstructive procedures included tissue expanded cheek flap(n = 10), deltopectoral flap(n = 10), and radial forearm free flap(n = 10). The measured sites were flap center within a radius of 1 ㎝ and four points of adjacent skin along the flap margin. The color was quantified in a three dimensional coordinate system $L^*$ (brightness), $a^*$ (redness), $b^*$ (yellowness). Results: There was no significant color difference between the pedicled flaps(tissue expanded cheek flap and deltopectoral flap) and adjacent skin area. On the other hand, color values of the radial forearm free flap were statistically different from those of adjacent skin area. Total color difference(${\Delta}E$) of tissue expanded cheek flap and deltopectoral flap were $7.45{\pm}5.78$ versus $9.41{\pm}7.09$, and that of radial forearm free flap was $11.74{\pm}3.85$. They suggest that pedicled flaps have a potential of better color match than radial forearm free flap. Conclusion: Thus, better esthetic result and satisfaction is more likely to be expected in pedicled flaps as long as it could be applied comparing radial forearm free flap.

Cu(In,Ga)$Se_2$ 박막의 Cu 결함 및 In, Ga 비율의 변화에 따른 구조적, 광학적, 전기적 특성 연구 (Structural, optical, and electrical properties on Cu(In,Ga)$Se_2$ thin-films with Cu-defects and In/(In+Ga) ratio)

  • 정아름;김지영;조윌렴;조현준;김대환;성시준;강진규;이동하;남다현;정현식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.47.1-47.1
    • /
    • 2011
  • We report on a direct measurement of two-dimensional chemical and electrical distribution on the surface of photovoltaic Cu(In,Ga)$Se_2$ thin-films using a nano-scale spectroscopic and electrical characterization, respectively. The Raman measurement reveals non-uniformed surface phonon vibration which comes from different compositional distribution and defects in the nature of polycrystalline thin-films. On the other hand, potential analysis by scanning Kelvin probe force microscopy shows a higher surface potential or a small work function on grain boundaries of the thin-films than on the grain surfaces. This demonstrates the grain boundary is positively charged and local built-in potential exist on grain boundary, which improve electron-hole separation on grain boundary. Local electrical transport measurements with scanning probe microscopy on the thin-films indicates that as external bias is increases, local current is started to flow from grain boundary and saturated over 0.3 V external bias. This accounts for carrier behavior in the vicinity of grain boundary with regard to defect states. We suggest that electron-hole separation at the grain boundary as well as chemical and electrical distribution of polycrystalline Cu(In,Ga)$Se_2$ thin-films.

  • PDF

분열효모에서 TREX-2 복합체의 구성요소인 Cdc31이 생장과 mRNA export에 미치는 영향 (Effects of Cdc31, a component of TREX-2 complex, on growth and mRNA export in fission yeast)

  • 고은진;윤진호
    • 미생물학회지
    • /
    • 제52권3호
    • /
    • pp.383-387
    • /
    • 2016
  • 분열효모 Schizosaccharomyces pombe의 cdc31 유전자는 진화적으로 잘 보존된 $Ca^{2+}$-결합 centrin/CDC31 계열에 속하며 방추극체(spindle pole body)의 한 성분인 단백질을 암호화하고 있다. 이 논문에서는 S. pombe의 Cdc31 단백질이 방추극체뿐만 아니라 TREX-2 복합체의 구성인자로서 mRNA의 핵에서 세포질로의 방출에 영향을 미치는지 알아보았다. cdc31 유전자의 발현을 억제하면 생장 결함을 보였고, $poly(A)^+$ RNA도 핵 안에 축적되는 현상을 보였다. 한편 cdc31 유전자를 과발현시키면, 생장과 mRNA 방출에 결함을 보이진 않았지만 세포의 길이가 길어지는 형태를 보였다. Yeast two-hybrid 분석에서 Cdc31 단백질은 TREX-2 복합체의 또 다른 구성인자인 Sac3 그리고 Pci2와 상호작용을 하였다. 이와 같은 결과들은 S. pombe의 Cdc31 단백질도 역시 TREX-2 복합체의 구성인자로 mRNA 방출에 관여하고 있음을 시사한다.