• 제목/요약/키워드: Half-value layer measurement

검색결과 20건 처리시간 0.02초

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

유방촬영의 kV X-선 빔에서 유효광자에너지에 대한 계산식 (Calculation Formula for Effective Photon Energy in kV X-ray Beam of Mammography)

  • 박영온;이상훈;김종언
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.507-514
    • /
    • 2023
  • 이 연구의 목적은 유방촬영의 X-선 빔에서 유효광자에너지를 쉽게 계산할 수 있는 계산식을 구하는데 있다. X2 MAM Sensor를 사용하여 각각의 설정관전압에 대하여 측정관전압을 얻었다. 알루미늄 여과체의 알루미늄에 대한 질량감쇠계수는 각각의 측정관전압 X-선 빔에서 반가층 측정으로부터 구하였다. 각각의 측정관전압 X-선 빔으로부터 구하여진 알루미늄의 질량감쇠계수는 NIST로부터 얻어진 광자에너지별 알루미늄의 질량감쇠계수에 대응시켰다. 일치하는 질량감쇠계수에 대응하는 광자에너지가 유효광자에너지로 결정되었다. 결정된 유효광자에너지의 계산식은 Origin pro 2019b 통계프로그램에서 각각의 측정관전압에 대한 유효광자에너지를 다항식으로 정합하여 y=28.98968-1.91738x+0.07786x2-0.000946717x3으로 얻었다. 여기서 x는 측정관전압이고, y는 유효광자에너지이다. 이 연구에서 얻어진 유방촬영 X-선 빔의 유효광자에너지의 계산식은 임상에서 X-선 빔과 어떤 물질과의 상호작용 계수를 구하는데 아주 유용하게 사용될 수 있을 것으로 사료된다.

토양(土壤)중 살충제(殺蟲劑) ethoprophos의 분해성(分解性) 및 이동성(移動性)의 측정(測定)과 예측(豫測)에 관한 모델 연구(硏究) (Simulation and Measurement of Degradation and Movement of Insecticide Ethoprophos in Soil)

  • 문영희;김윤태;김영석;한수곤
    • 한국환경농학회지
    • /
    • 제12권3호
    • /
    • pp.209-218
    • /
    • 1993
  • 토양(土壤)중에 있어서 살충제(殺蟲劑) ethoprophos의 행동특성(行動特性)을 조사(調査)한 결과(結果)를 요약(要約)하면 다음과 같다. 실내조건(室內條件)중의 토양(土壤)중 ethoprophos분해(分解)는 일차반응식(一次反應式)에 따랐으며, 반감기(半減期)는 10, 18, $25^{\circ}C$ 에서 각각 12.4, 5.5, 2.5일이었고, Arrhenius activation energy는 73.8 KJ/mol이었다. 수분함량(水分含量)이 7, 14, 19%인 토양(土壤)에서 ethoprophos의 반감기(半減期)는 각각 46.4, 17.6, 6.9일이었으며 Empirical방정식에서 수분의존도(水分依存度)(B)값은 1.67이었다. Ethoprophos의 토양(土壤)중 흡착등온선(吸着等溫線)은 Freundlich식(式)에 따랐으며 흡착분배계수(吸着分配係數)(Kd)값은 0.27이었다. Mini-lysimeter를 이용한 실외조건(室外條件)하의 이동실험(移動實驗)에서 ethoprophos는 대부분이 $0{\sim}2cm$층위(層位)에 분포(分布)되었으며 6cm층위(層位)까지 이동(移動)되었다. 실외포장(室外圃場)에서 ethoprophos의 분해(分解)는 기상변화(氣象變化)와 밀접한 관계를 보였으며, 3월과 10월의 처리에서 반감기(半減期)는 각각 17일과 5일 정도이었고, 처리 후 약 37일에는 90%까지 분해(分解) 소실(消失)되었다. 토양(土壤)중 농약(農藥)의 행동(行動) 예측(豫測) computer model에 의한 ethoprophos의 이동성(移動性)과 잔유성(殘留性)의 예측치(豫測値)는 분석치(分析値)와 유사(類似)하였다.

  • PDF

2층 고무/코드 적층판의 피로 수명 예측 (Prediction of Fatigue Life in 2 Ply Rubber/Cord Laminate)

  • 임동진;이윤기;윤희석;김민호
    • Composites Research
    • /
    • 제16권3호
    • /
    • pp.9-17
    • /
    • 2003
  • 타이어 벨트층내의 코드간 균열연결 및 층간균열진전을 모사하기 위해 자유단을 갖는 2층 고무/코드 적층시험편에 대한 4~11mm 변위제어 실험을 수행하였다. 자유단의 코드간 균열연결시의 폭방향 균열진전량은 45$^{\circ}$ 경사진 코드들간 길이의 절반에 도달할 때의 측정값으로 하였으며, 이는 탐침법에 의해 측정되었다 또한, 자유단에서 코드들간 균열연결을 모사하기위해 2차원의 이상화된 모델링 기법을 고안하였다. 이론수명은 테어링에너지(균열파단면의 단위면적당 방출에너지)를 이용하여 코드간 균열연결수명(임계값)과 이후 최종파손까지의 수명으로 구분하였으며, 이들을 각기 실험값과 비교하였다. 임계값까지의 수명예측은 실험과 비교하여 약 20%, 최종파손까지 약 65%의 오차가 발생하였다. 따라서, 전체 이론수명은 실험과 비교하여 약 45%의 오차를 발생하였다.

치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구 (THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY)

  • 박태원
    • 치과방사선
    • /
    • 제9권1호
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF

이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구 (A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.

Fabrication of Schottky Device Using Lead Sulfide Colloidal Quantum Dot

  • Kim, Jun-Kwan;Song, Jung-Hoon;An, Hye-Jin;Choi, Hye-Kyoung;Jeong, So-Hee
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.189-189
    • /
    • 2012
  • Lead sulfide (PbS) nanocrystal quantum dots (NQDs) are promising materials for various optoelectronic devices, especially solar cells, because of their tunability of the optical band-gap controlled by adjusting the diameter of NQDs. PbS is a IV-VI semiconductor enabling infrared-absorption and it can be synthesized using solution process methods. A wide choice of the diameter of PbS NQDs is also a benefit to achieve the quantum confinement regime due to its large Bohr exciton radius (20 nm). To exploit these desirable properties, many research groups have intensively studied to apply for the photovoltaic devices. There are several essential requirements to fabricate the efficient NQDs-based solar cell. First of all, highly confined PbS QDs should be synthesized resulting in a narrow peak with a small full width-half maximum value at the first exciton transition observed in UV-Vis absorbance and photoluminescence spectra. In other words, the size-uniformity of NQDs ought to secure under 5%. Second, PbS NQDs should be assembled carefully in order to enhance the electronic coupling between adjacent NQDs by controlling the inter-QDs distance. Finally, appropriate structure for the photovoltaic device is the key issue to extract the photo-generated carriers from light-absorbing layer in solar cell. In this step, workfunction and Fermi energy difference could be precisely considered for Schottky and hetero junction device, respectively. In this presentation, we introduce the strategy to obtain high performance solar cell fabricated using PbS NQDs below the size of the Bohr radius. The PbS NQDs with various diameters were synthesized using methods established by Hines with a few modifications. PbS NQDs solids were assembled using layer-by-layer spin-coating method. Subsequent ligand-exchange was carried out using 1,2-ethanedithiol (EDT) to reduce inter-NQDs distance. Finally, Schottky junction solar cells were fabricated on ITO-coated glass and 150 nm-thick Al was deposited on the top of PbS NQDs solids as a top electrode using thermal evaporation technique. To evaluate the solar cell performance, current-voltage (I-V) measurement were performed under AM 1.5G solar spectrum at 1 sun intensity. As a result, we could achieve the power conversion efficiency of 3.33% at Schottky junction solar cell. This result indicates that high performance solar cell is successfully fabricated by optimizing the all steps as mentioned above in this work.

  • PDF

고에너지 광자선에 대한 금속구의 차폐효과 (Protection effect of metal balls against high energy photon beams)

  • 강위생;강석종
    • 한국의학물리학회지:의학물리
    • /
    • 제9권3호
    • /
    • pp.137-141
    • /
    • 1998
  • 납공 (lead ball)과 쇠공(steel ball)을 고에너지 광자선에 대한 차폐재로 이용하는 것이 가능한가를 평가하고 ,4~10MV 엑스선 차폐를 위한 납공과 쇠공의 물리자료를 구하는 것이 목적이다. 직경이 각각 2.0-2.5mm, 1.5-2.0mm 인 납공 및 쇠공을 폭이 균일한 아크릴 용기에 채워, 두께의 균일성 확인을 위해 MV 엑스선사진을 촬영하였으며, 금속공의 평균 밀도와 4~10MV 엑스선에 대한 선감쇠계수를 측정하였다. 선감쇠계수를 측정할 때 Farmer 이온함을 이용하였으며 산란선의 효과를 최소화하기 위해 70cm 거리에서 조사면크기는 5.5cm$\times$5.5cm로 하였다. 비교하기 위해 납판과 철판에 대해서도 같은 종류의 변수를 구하였다. 금속구를 용기에 채웠을 때 분포는 균일하였으며, 납 -공기 혼합물의 밀도는 6.93g/$cm^3$이었으며, 철-공기 혼합물의 밀도는 4.75g/$cm^3$ 이었다. 납의 밀도에 대한 납-공기 혼합물의 밀도의 비는 0.611, 철에 대한 철-공기 혼합물의 밀도의 비는 0.604이었다. 납-공기 혼합물의 반가층은 4MV, 6MV, 10MV 엑스선 각각에 대하여 1.89cm, 2.07cm, 2.16cm 이었으며 납판 반가층의 약 1.64배였다. 철-공기 혼합물의 반가층은 4MV, 6MV, 10MV 엑스선 각각에 대하여 3.24cm, 3.70cm, 4.15cm 이었으며 철판 반가 층의 약 1.65 배였다. 금속구는 용기속에 고르게 채워질 수 있기 때문에 차폐재료로 쓸 수 있다. 납공과 쇠공이 고르게 채워질 때 밀도는 각각 6.93g/$cm^3$, 4.75g/$cm^3$ 이었으며 각각의 반가층은 납 또는 철의 반가층의 1.65배였다. 밀도와 반가층을 곱한 값은 공이나 판에 대해 같은 값이었다.

  • PDF

황해 남동부 해역의 월별 용존무기탄소 재고 추정 (Estimation of Monthly Dissolved Inorganic Carbon Inventory in the Southeastern Yellow Sea)

  • 김소윤;이동섭
    • 한국해양학회지:바다
    • /
    • 제27권4호
    • /
    • pp.194-210
    • /
    • 2022
  • 동중국해 북부와 경계를 이루는 황해 남동부 해역에 대해 무기탄소의 월별 재고와 변동을 초래하는 플럭스들을 상자 모형으로 모의하였다. 월별 용존무기탄소의 자료는 네 차례 계절을 대표하는 관측 결과에 최근 발표된 논문의 자료를 발췌하여 구성하였다. 연간 용존무기탄소(CT)의 재고가 정상상태에 있으며 표층에서 이류에 의한 변동이 무시할 정도로 작다고 가정하고 표층과 심층의 2-상자 모형을 사용했다. 모의 결과 월별 표층과 심층 사이의 재고는 혼합층 두께의 변동에 따른 혼합 플럭스가 -40~35 mol C m-2 month-1의 규모로 주도했다. 대기로부터 유입되는 CO2 플럭스는 약 2 mol C m-2 yr-1 이고, 혼합 플럭스의 1/100 미만으로 작았다. 생물 펌프 플럭스는 4~5 mol C m-2 yr-1 범위로 추정되었는데 이는 현장 실측 자료에 비해서 절반가량 수준이다. 물기둥의 CT 재고는 동계 혼합이 끝나는 4월에 최대를 보이며 성층기에 조금씩 줄어든다. 따라서 CT 총량은 성층기에 혼합기보다 높게 나타나는데 정상상태가 유지되려면 최대와 최소의 차분인 18 mol C m-2 yr-1 (= 216 g C m-2 yr-1)이 동중국해로 송출되어야 한다. 이를 황해 남부 경계 전체에 대해 외삽하면 4 × 109 g C yr-1 규모이다. 이 플럭스는 개념상 대륙붕 펌프에 해당한다. 실제로 태평양 외양역에 도달하려면 동중국해를 거쳐야 하므로 실제로 대륙붕 펌프로 기여하는 플럭스의 크기는 이보다 현저하게 낮을 것으로 전망된다. 자료 부족과 계산에 필수적인 가정에 수반되는 오류 때문에 추정값은 상당한 크기의 오차를 포함하지만 모의를 통해 CT의 변동을 초래하는 플럭스 사이의 상대적인 기여도와 범위를 제약할 수 있었고 향후 연구에서 주목해야 할 사항을 도출할 수 있었다.

1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로 (Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City)

  • 동경래;이선주;권대철;구은회;정재은;이규수
    • Journal of Radiation Protection and Research
    • /
    • 제35권1호
    • /
    • pp.34-42
    • /
    • 2010
  • 현대 의학에서 방사선 이용 영역이 확대되고 비중이 커짐에 따라 개인 피폭선량을 줄이기 위한 노력을 하고 있는 가운데 가장 중요한 문제로 대두되고 있는 것이 방사선 기기에 관한 정도관리이다. 그래서 광주광역시 1차병원을 5개의 구로 나누어 각 구에서 임의로 10개소의 병원을 선정하여 정도관리 항목들의 실제 측정 실험과 광주지역 정도관리 현황에 대해 알아보고자 한다. 실험은 관전압, 관전류, 조사시간의 재현성 시험, 조도측정, 반가층 측정, 중심선속 일치 실험을 시행하였으며, 관전압 재현성 실험 결과 전체 50군데의 병원 합격률은 95.3%로 나타났고 관전류와 조사시간은 각각 77.0%의 합격률을 보였다. 조도는 86.0%의 합격률을 보였다. 반가층은 52.0%의 합격률을 보여 네개의 실험중 가장 낮은 합격률을 보였다. 중심선속 일치실험에서는 대체로 $1.5^{\circ}$ 이내로 중심선속이 일치하였으나 전체 50군데중 30.0%가 중심선속이 $3^{\circ}$이내로 벗어났다. 설문조사 결과로는 58.0%가 정도관리 주기에 대해 알고 있다고 답했으며, 50명 모두 현재 근무하는 병원에서 정도관리에 관한 교육을 받은 적이 없다고 답했다. 비교적 정도관리는 잘 이루어지고 있었지만 가장 시급한 문제는 정도관리의 중요성에 관한 인식이다. 따라서 방사선 작업 종사자들에게 전문적으로 안전관리에 관한 교육과 정확한 방사선 정도관리를 시행한다면 방사선 작업 종사자와 환자에 대한 피폭을 줄일 수 있으며 또한 적은 선량으로 질 높은 영상을 만들 수 있을 것으로 사료된다.