• Title/Summary/Keyword: Half-Bridge Inverter

Search Result 260, Processing Time 0.022 seconds

A New Half-bridge Resonant Inverter with Load-Freewheeling Modes

  • Yeon, Jae-Eul;Cho, Kyu-Min;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.249-256
    • /
    • 2007
  • This paper presents a new circuit topology and its digital control scheme for a half-bridge resonant inverter. As the proposed half-bridge inverter can be operated in load-freewheeling modes, the pulse-width modulation (PWM) method can be used for the output power control. The proposed half-bridge inverter is based on the resonant frequency-tracking algorithm with the goal of maintaining the unity of the output displacement factor of the load impedance even in varying conditions. In this paper, the operation principle, electrical characteristics, and detailed digital control scheme of the proposed half-bridge resonant inverter are described. The experimental results of the prototype experimental setup to verify the validity of the proposed half-bridge inverter are presented and discussed.

Buck-Boost Interleaved Inverter Configuration for Multiple-Load Induction Cooking Application

  • Sharath Kumar, P.;Vishwanathan, N.;Bhagwan, K. Murthy
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.271-279
    • /
    • 2015
  • Induction cooking application with multiple loads need high power inverters and appropriate control techniques. This paper proposes an inverter configuration with buck-boost converter for multiple load induction cooking application with independent control of each load. It uses one half-bridge for each load. For a given dc supply of $V_{DC}$, one more $V_{DC}$ is derived using buck-boost converter giving $2V_{DC}$ as the input to each half-bridge inverter. Series resonant loads are connected between the centre point of $2V_{DC}$ and each half-bridge. The output voltage across each load is like that of a full-bridge inverter. In the proposed configuration, half of the output power is supplied to each load directly from the source and remaining half of the output power is supplied to each load through buck-boost converter. With buck-boost converter, each half-bridge inverter output power is increased to a full-bridge inverter output power level. Each half-bridge is operated with constant and same switching frequency with asymmetrical duty cycle (ADC) control technique. By ADC, output power of each load is independently controlled. This configuration also offers reduced component count. The proposed inverter configuration is simulated and experimentally verified with two loads. Simulation and experimental results are in good agreement. This configuration can be extended to multiple loads.

A Study on the Reliability and Optimal Control of Half-Bridge Inverter for Induction Beating System (유도 가열용 Half-Bridge 인버터 시스템의 신뢰성 향상 및 최적제어에 관한 연구)

  • 유상봉
    • Journal of the Korean Professional Engineers Association
    • /
    • v.33 no.1
    • /
    • pp.94-105
    • /
    • 2000
  • The purpose of this paper is to obtain the improved reliability and optimal control of the half-bridge inverter for induction heating system. Parasitic inductance components within the inverter circuit for induction heating including the loss-less turn-off snubber capacitor considerably affect stable operation and noise level of the system. This paper analyzes the effect of the inductance in detail and presents a new snubber configuration suitable for the half-bridge inverter to effectively reduce it. In the half-bridge inverter for induction heating the capacity of the loss-less snubber capacitor determines the switching losses because the zero voltage turn-on switching is used. However, the increase of the capacitor is limited by the system specifications, so that it is not easy work to reduce the switching loss. To effectively overcome the limitation, this paper introduces an active auxiliary resonant circuit suitable for the half-bridge inverter circuit, which operates actively according to the variation of load condition. It is also one of the most important study issues for the half-bridge inverter driven induction heater that the development of optimal control scheme considering varied load condition should be achieved. The control strategy ensures a very stable operation of overall inverter system and zero voltage turn-on switching irrespective of sensitive load parameter variations, in particular, even under the non-magnetic materials.

  • PDF

A New Resonant H/B Inverter Having Load Freewheeling Modes (부한 환류모드를 갖는 새로운 반 브리지 공진형인버터)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Oh, Won-Seok;Kim, Hee-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.153-156
    • /
    • 2004
  • This paper presents a new circuit topology of the half-bridge resonant inverter. As the proposed half-bridge inverter can be operated in the load freewheeling modes, pulse width modulation (PWM) control method can be used for the output power control. The proposed half-bridge inverter should keep unity output displacement factor under the load-impedance varying conditions, if a new PWM control scheme based on the resonant frequency tracking algorithm is adopted. In this paper, electrical characteristics, and losses analysis of the proposed half-bridge resonant inverter are described. Simulation and experimental results of the prototype experimental setup to verify the validity of the proposed half-bridge resonant inverter are presented and discussed.

  • PDF

Fuel Cell Generation System Combined Interleaved Full-bridge Converter with Half-bridge Inverter (인터리브드 풀브릿지 컨버터와 하프브릿지 인버터를 결합한 연료전지 발전 시스템)

  • Kim, Heon-Hee;Lee, Hee-Jun;Shin, Soo-Chul;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.518-519
    • /
    • 2012
  • This paper suggested a fuel cell generation system which combined interleaved full-bridge converter with half-bridge inverter. High ratio step-up converter is essential to use the power as general voltage source. Full-bridge converter has high efficiency and can boost the input voltage to high output with transformer. With series connected capacitors, interleaved full-bridge converter and half-bridge inverter are combined. Half-bridge inverter has two fewer switches compared to full-bridge type. Also, switching loss can be reduced. The performance is verified through simulation with 1.5[kW] fuel cell generation system.

  • PDF

A Novel Half-Bridge Resonant Inverter With Load Free-wheeling Modes (부하 환류모드를 갖는 새로운 하프 브리지 공진형 인버터)

  • Yeon Jae-Eul;Cho Kyu-Min;Kim Hee-Jun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.3 s.303
    • /
    • pp.71-80
    • /
    • 2005
  • This paper proposes a new circuit topology of the half-bridge resonant inverter and presents its digital control scheme. As the proposed half-bridge inverter can be operated in the load-freewheeling modes, pulse width modulation (PWM) control method can be used for the output power control. The proposed half-bridge inverter can keep unity output displacement factor under the load-impedance varying conditions, if a new PWM control scheme based on the resonant frequency tracking algorithm is adopted. In this paper, the operation principle, electrical characteristics and detailed digital control scheme of the proposed half-bridge resonant inverter and loss analysis comparing with a conventional half bridge inverter is described. The experimental results of the proto-type experimental setup to verify the validity of the proposed half-bridge resonant inverter are presented and discussed.

New PCS Applied High Boost Ratio Dual Converter and Single Phase Half Bridge Inverter (고승압 듀얼 컨버터와 단상 하프 브릿지 인버터를 적용한 새로운 PCS)

  • Lee, Hee-Jun;Shin, Soo-Choel;Hyun, Seung-Wook;Jung, Yong-Chae;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.515-522
    • /
    • 2013
  • In this paper, a new PCS is proposed which is consisted of high boost dual converter and single phase half-bridge inverter. The proposed PCS is configured in parallel input / serial output, using two interleaved voltage doubler converter. Converter of the proposed PCS is distribute input current by configuring parallel input and reduced turn ratio of transformer by configuring serial output. Also, compositions of the inverter are composed of serial output capacitor of converter and half-bridge inverter. The dual converter and single phase half-bridge inverter is designed and characteristic of the new PCS is analysed. The system of the 1.5[kW] PCS is verified through an experimental about operation and stability.

A Study on Single-Stage High Frequency Resonant Inverter (단일전력단으로 구성된 고주파 공진 인버터에 관한 연구)

  • Won J. S.;Kang J. W.;Kim D. H.;Jung S. G.;Lee Y. S.;Lee B. S.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.750-753
    • /
    • 2002
  • A novel single-stage half-bridge high frequency resonant inverter using ZVS(Zero Voltage Switching) with high input power factor suitable for induction heating applications is presented in this paper. The proposed high frequency resonant Inverter integrates half-bridge boost rectifier as power factor corrector(PFC) and half-bridge resonant inverter into a single stage. The input stage of the half-bridge boost rectifier is working in discontinuous conduction mode (DCM) with constant duty cycle and variable switching frequency. Simulation results through the Pspice have demonstrated the feasibility of the proposed inverter. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

High Power-Factor Single-Stage Half-Bridge High Frequency Resonant Inver (고역률을 가지는 Single-Stage Half-Bridge 고주파 공진 인버터)

  • Won, Jae-Sun;Kim, Dong-Hee;Seo, Cheol-Sik;Cho, Gyu-Pan;Oh, Seung-Hoon;Jung, Do-Young;Bae, Yeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1196-1198
    • /
    • 2002
  • A novel single-stage half-bridge high frequency resonant inverter using ZVS(Zero Voltage Switching) with high input power factor suitable for induction heating applications is presented in this paper. The proposed high frequency resonant inverter integrates half-bridge boost rectifier as power factor corrector(PFC) and half-bridge resonant inverter into a single stage. The input stage of the half-bridge boost rectifier is working in discontinuous conduction mode (DCM) with constant duty cycle and variable switching frequency. So that a high power factor is achieved naturally. Simulation results through the Pspice have demonstrated the feasibility of the proposed inverter. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

Self-Excited Half-Bridge Inverter for Contact less Charger (무접촉 충전기용 자려식 Half-Bridge 인버터)

  • Kim, Yun-Sung;Ahn, Tae-Young;Choi, Byung-Cho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1074-1076
    • /
    • 2000
  • This Paper reports on an experimental and theoretical work about self exited Half-Bridge inverter for contact less battery chargers. The steady state characteristics of inverter are analysis and the experimental result for 500kHz, universal AC source input have been obtained. These inverter is suitable for the portable appliances with battery chargers such as cellular phone.

  • PDF