• 제목/요약/키워드: Half Mirror

검색결과 64건 처리시간 0.024초

A NON-RECURSIVE APPROACH TO NEVANLINNA-PICK INTERPOLATION PROBLEM

  • Kim, Jeongook
    • 호남수학학술지
    • /
    • 제41권4호
    • /
    • pp.823-835
    • /
    • 2019
  • A solution for Nevanlinna-Pick interpolation problem with low complexity is constructed via non-recursive method. More precisely, a stable rational function satifying the given interpolation data in the complex right half plane is found by solving a homogeneous interpolation problem related to a minial interpolation problem for the given data in the right half plane together with its mirror-image data.

AC-PDP의 휘도와 효율 향상을 위한 Dichroic Mirror의 응용에 관한 연구 (A study on the application of dichroic mirror for the improvement of luminance and luminous efficacy in an AC Plasma Display Panel)

  • 송병무;김중균;황만수;황기웅
    • 한국진공학회지
    • /
    • 제10권1호
    • /
    • pp.98-103
    • /
    • 2001
  • 차세대 평판 디스플레이로서 플라즈마표시기(Plasma Display Pannel, PDP)는 현재 350 $\textrm{cd/cm}^2$의 휘도와 l lm/W 정도의 효율을 갖는 AC형 PDP가 개발되어 있으나, 음극선관(CRT)의 피크 휘도가 700 $\textrm{cd/cm}^2$, 효율이 수 1 m/W인 것을 감안하면 음극선관을 대체할 수 있는 표시기가 되기 위해서는 PDP의 휘도와 효율을 더욱 개선시킬 필요가 있다. 반사형 AC-PDP셀 내에서 가스 방전으로 발생된 진공 자외선(Vacuum Utraviolet, VUV) 중 배면판 쪽으로 진행되는 부분은 형광체를 여기시켜 가시광을 발생시키게 되지만, 전면판 쪽으로 진행되는 부분은 발광에 사용되지 못하고 있다. 본 연구에서는 PDP 셀 전면판의 유전체와 보호막 사이에 VUV를 반사시킬 수 있는 다이크로익 미러(Dichroic mirror)를 증착함으로써 셀 내의 VUV 이용 효율을 증가시켜 휘도와 효율을 향상시킬 수 있는 방법을 제안하였다. 다이크로익 미러를 정확하게 설계하기 위해서 미러에 사용되는 $MgF_2$, $LaF_3$, MgO 박막의 VUV 영역에서의 광학 계수(Optical Constant)를 실험과 시뮬레이션을 이용한 광도 측정법(Photometric method)을 통해서 구하였다 (1). 이 값들을 이용해서 플라즈마 표시기의 패널 방전에서 방출되는 빛의 휘도를 결정짓는 가장 중요한 요소인 147nm 부근의 진공자외선을 반사시킬 수 있는 다이크로익 미러를 설계하였다. 다이크로익 미러는 전자빔 증착기 (I-beam evaporator)를 이용하여 증착되었고, 박막의 광학 계수 결정을 위한 반사도(Reflectance), 투과도(Transmittance) 측정과 다이크로익 미러의 반사도 측정은 Reflectometer를 이용해 측정하였다. 패널 실험은 동일한 패널 내에 반쪽 면에만 다이크로익 미러를 증착시켜 방전 전압에 따른 휘도와 효율을 미러가 없는 면과 동일 조건하에 비교 측정하였다. 여러 방전 조건하에서 다이크로익 미러를 AC-PDP에 적용한 경우가 그렇지 않은 경우보다 휘도와 효율이 약 20-30% 정도 증가함을 확인하였다.

  • PDF

정상모드에서 수신된 텔레메트리를 이용한 외란에 의한 천리안위성 자세영향 분석 (Attitude analysis induced by the disturbances on COMS using the received telemetries during normal mode)

  • 박영웅;박봉규
    • 항공우주기술
    • /
    • 제11권1호
    • /
    • pp.27-41
    • /
    • 2012
  • 본 논문에서는 천리안위성의 자세에 영향을 미치고 있는 외란과 그 영향을 KARI 지상국에 수신된 정상모드 텔레메트리를 통해 분석하였다. 천리안위성은 2010년 6월 26일에 쿠루 발사장에서 성공적으로 발사된 후 궤도상시험까지 마치고 현재까지 약 1년 6개월간 주요 임무인 기상과 해양 관측을 완벽하게 수행하고 있다. 천리안 위성 자세에 영향을 미치는 외란으로는 태양에 의한 것, 탑재체 미러 기동과 지구센서 미러 및 휠 기동에서 발생되는 스파이크에 의한 것 등이 주로 관측되었다. 이외에 운용을 하면서 발생된 특이한 자세영향을 분석한 결과를 정리하였다.

스타일링을 위한 스마트 미러 (Smart Mirror for Styling)

  • 강수빈;권승하;김윤호;이수익;한영오
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1271-1278
    • /
    • 2021
  • 본 논문에서는 얼굴인식을 통해 가상으로 사용자의 얼굴에 안경 및 헤어 스타일을 선택하여 체험하고 날씨별 옷차림을 추천하여 다양한 스타일을 가이드하는 스마트 미러를 구현하였다. 또한 영상을 시청하는 동시에 화면을 보면서 메이크업이 가능하다. 그리고 라즈베리파이, 아크릴판, 하프 미러 필름을 사용하여 기존의 스마트 미러의 비용을 절감하였다. 날씨, 날짜, 달력, 뉴스 등의 기본 정보도 추가하였으며, 터치스크린을 사용함으로써 사용자의 편의를 증대하였다.

LED Array의 반사영상에 의한 경면체의 3차원 형상 측정 (Three-Dimensional Shape Measurement of a Specular Object by LED Array Reflection)

  • 김지홍
    • 한국광학회지
    • /
    • 제27권1호
    • /
    • pp.41-46
    • /
    • 2016
  • 본 논문은 경면체의 3차원 형상을 측정하기 위한 광학시스템에 관한 것으로, 특히 LED 배열로 이루어진 점광원과 하프미러, 이미지센서로 구성된 비전시스템을 구성하여 광로분석을 수행하고 효과적인 근사화 방법을 제시한다. 실험을 통하여 취득된 영상 내의 점광원의 상대적 위치변화로부터 경면체의 3차원형상의 효과적 추정이 가능함을 보인다.

A Two-Step Micromirror for Low Voltage Operation

  • Hwang Yong-Ha;Han Seungoh;Lee Byung-Kab;Kim Jae-Soon;Pak James Jungho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권6호
    • /
    • pp.270-275
    • /
    • 2005
  • In order for the application of the in-vivo endoscopic biopsy, a micromirror which can be driven at a low voltage is required. In this paper, a two-step micromirror composed of bottom electrodes, moving plate and top mirror plate is proposed. Because an electrical wiring of two plates are separated, they can be actuated separately. Therefore, an intermediate moving plate plays an important role in reducing the driving voltage in half. The designed device was fabricated by the surface micromachining. Maximum rotation angle of $6.3^{\circ}$ was obtained by applying DC 48V, while a conventional one-step mirror pulled down at DC 120V. The designed structure can be used in microphotonic applications requiring low driving voltage.

Performance Improvement of Near Earth Space Survey (NESS) Wide-Field Telescope (NESS-2) Optics

  • Yu, Sung-Yeol;Yi, Hyun-Su;Lee, Jae-Hyeob;Yim, Hong-Suh;Choi, Young-Jun;Yang, Ho-Soon;Lee, Yun-Woo;Moon, Hong-Kyu;Byun, Yong-Ik;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권2호
    • /
    • pp.153-160
    • /
    • 2010
  • We modified the optical system of 500 mm wide-field telescope of which point spread function showed an irregularity. The telescope has been operated for Near Earth Space Survey (NESS) located at Siding Spring Observatory (SSO) in Australia, and the optical system was brought back to Korea in January 2008. After performing a numerical simulation with the tested value of surface figure error of the primary mirror using optical design program, we found that the surface figure error of the mirror should be fabricated less than root mean square (RMS) $\lambda$/10 in order to obtain a stellar full width at half maximum (FWHM) below $28\;{\mu}m$. However, we started to figure the mirror for the target value of RMS $\lambda$/20, because system surface figure error would be increased by the error induced by the optical axis adjustment, mirror cell installation, and others. The radius of curvature of the primary mirror was 1,946 mm after the correction. Its measured surface figure error was less than RMS $\lambda$/20 on the table of polishing machine, and RMS $\lambda$/15 after installation in the primary mirror cell. A test observation performed at Daeduk Observatory at Korea Astronomy and Space Science Institute by utilizing the exiting mount, and resulted in $39.8\;{\mu}m$ of stellar FWHM. It was larger than the value from numerical simulation, and showed wing-shaped stellar image. It turned out that the measured-curvature of the secondary mirror, 1,820 mm, was not the same as the designed one, 1,795.977 mm. We fabricated the secondary mirror to the designed value, and finally obtained a stellar FWHM of $27\;{\mu}m$ after re-installation of the optical system into SSO NESS Observatory in Australia.

DEVELOPMENT OF LIGHTWEIGHT OPTICAL TELESCOPE KIT USING ALUMINUM PROFILE AND ISOGRID STRUCTURE

  • Park, Woojin;Lee, Sunwoo;Han, Jimin;Ahn, Hojae;Ji, Tae-Geun;Kim, Changgon;Kim, Dohoon;Lee, Sumin;Kim, Young-Jae;Kim, Geon-Hee;Kim, Junghyun;Kim, Ilhoon;Pak, Soojong
    • 천문학회지
    • /
    • 제55권1호
    • /
    • pp.11-22
    • /
    • 2022
  • We introduce the Transformable Reflective Telescope (TRT) kit that applies an aluminum profile as a base plate for precise, stable, and lightweight optical system. It has been utilized for optical surface measurements, developing alignment and baffle systems, observing celestial objects, and various educational purposes through Research & Education projects. We upgraded the TRT kit using the aluminum profile and truss and isogrid structures for a high-end optical test device that can be used for prototyping of precision telescopes or satellite optical systems. Thanks to the substantial aluminum profile and lightweight design, mechanical deformation by self-weight is reduced to maximum 67.5 ㎛, which is an acceptable misalignment error compared to its tolerance limits. From the analysis results of non-linear vibration simulations, we have verified that the kit survives in harsh vibration environments. The primary mirror and secondary mirror modules are precisely aligned within 50 ㎛ positioning error using the high accuracy surface finished aluminum profile and optomechanical parts. The cross laser module helps to align the secondary mirror to fine-tune the optical system. The TRT kit with the precision aluminum mirror guarantees high quality optical performance of 5.53 ㎛ Full Width at Half Maximum (FWHM) at the field center.

그래픽 DRAM 인터페이스용 5.4Gb/s 클럭 및 데이터 복원회로 (A 5.4Gb/s Clock and Data Recovery Circuit for Graphic DRAM Interface)

  • 김영란;김경애;이승준;박성민
    • 대한전자공학회논문지SD
    • /
    • 제44권2호
    • /
    • pp.19-24
    • /
    • 2007
  • 최근 대용량 데이터 전송이 이루어지면서 하드웨어의 복잡성과 전력, 가격 등의 이유로 인하여 입력데이터와 클럭을 함께 수신 단으로 전송하는 병렬버스 기법보다는 시리얼 링크 기법이 메모리 인터페이스에 많이 사용되고 있다. 시리얼 링크 기법은 병렬버스 기법과는 달리 클럭을 제외한 데이터 정보만을 수신단으로 보내는 방식이다. 클럭 및 데이터 복원 회로(clock and data recovery 혹은 CDR)는 시리얼 링크의 핵심 블록으로, 본 논문에서는 그래픽 DRAM 인터페이스용의 5.4Gb/s half-rate bang-bang 클럭 및 데이터 복원회로를 설계하였다. 이 회로는 half-rate bang-bang 위상검출기, current-mirror 전하펌프, 이차 루프필터, 및 4단의 차동 링타입 VCO로 구성되었다. 위상 검출기의 내부에서 반 주기로 DeMUX된 데이터를 복원할 수 있게 하였고, 전체 회로의 용이한 검증을 위해 MUX를 연결하여, 수신된 데이터가 제대로 복원이 되는지를 확인하였다. 설계한 회로는 66㎚ CMOS 공정파라미터를 기반으로 설계 및 layout하였고, post-layout 시뮬레이션을 위해 5.4Gb/s의 $2^{13}-1$ PRBS 입력데이터를 사용하였다. 실제 PCB 환경의 유사 기생성분을 포함하여 시뮬레이션 한 결과, 10psRMS 클럭 지터 및 $40ps_{p-p}$ 복원된 데이터 지터 특성을 가지고, 1.8V 단일 전원전압으로부터 약 80mW 전력소모를 보인다.

냉간 압연기용 롤의 배열이 마멸에 미치는 영향 (The Effect of Roll Arrangement in the Cold Rolling Mill on the Wear)

  • 손영지
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.74-80
    • /
    • 1999
  • Work roll wear in the cold rolling of mild steel strip is strongly affected by rolling materials, rolling conditions such as roll arrangement in the cold rolling mill and lubrication. The tests were performed to find the effects of roll arrangement n the cold rolling mill on the work roll wear under the same lubricating conditions. The obtained results are as follows:If the distance of cold rolling is about 60km, the surface roughness of its was reduced by half(Ra 0.49${\mu}{\textrm}{m}$) and Pc(peak count) also was decreased to 60 ea/cm.It is easier for CC(Continuous casting) to make a slip on rolling than IC(Ingot casting). It is due to surface mirror in which first residual product appears and iron powder included Al2O3 is sticked. Because bending degree of 4Hi-rolling mill is higher than 6Hi-rolling mill, the first surface mirror was occurred to its center-point which is loaded strongly. 6Hi-rolling mill shape-controlled by intermediate roll doesn't need the initial crown to work roll. Therefore, fatigue and wear would appear a little bit.

  • PDF