• Title/Summary/Keyword: Half Disc

Search Result 45, Processing Time 0.027 seconds

Vertically Half Disc-Loaded Ultrawideband Monopole Antenna (VHDMA) with Horizontally Top-Loaded Small Disc (수평 원형 디스크가 로딩된 반원 디스크 초광대역 모노폴 안테나)

  • 이재욱;조춘식;김종면
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.11
    • /
    • pp.1051-1061
    • /
    • 2004
  • In this Paper, a new antenna(VHMDA) characteristics of half-circular/elliptical disc-loaded planar antennas with horizontally top-loaded small disc is studied by simulation and measurements with additional resonant structure. The transfer function characteristics of Gaussian pulse from the designed UWB transmitter antenna has been investigated. The radiation pattern of the proposed antenna in azimuth is nearly omni-directional response, which is usulally required in conventional monopole antenna. In addition to that, the simulation and measured results show that the return loss characteristics of VHDMA covers considerably large bandwidth with small area. From the measured results of the circular and half-circular disc-loaded monopole antennas with small disc mounted on the top, it is found that the half disc-loaded monopole antenna with additional structure can be comparable to the circular disc-loaded monopole antenna in respect o( size and electrical performances. Surface wave and dielectric losses often caused by the printed antenna using high dielectric constant does not occur in metallic planar antenna with good impedance matching and without lossy matching unit. This structure implies that the performance of return loss is directly related with the radiation efficiency.

Cu Via-Filling Characteristics with Rotating-Speed Variation of the Rotating Disc Electrode for Chip-stack-package Applications (칩 스택 패키지에 적용을 위한 Rotating Disc Electrode의 회전속도에 따른 Cu Via Filling 특성 분석)

  • Lee, Kwang-Yong;Oh, Tae-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.3
    • /
    • pp.65-71
    • /
    • 2007
  • For chip-stack package applications, Cu filling characteristics into trench vias of $75{\sim}10\;{\mu}m$ width and 3 mm length were investigated with variations of the electroplating current density and the speed of a rotating disc electrode (RDE). Cu filling characteristics into trench vias were improved with increasing the RDE speed. There was a Nernst relationship between half width of trench vias of Cu filling ratio higher than 95% and the minimum RDE speed, and the half width of trenches with 95% Cu filling ratio was linearly proportional to the reciprocal of root of the minimum RED speed.

  • PDF

Unintentional temporomandibular joint disc reduction after orthognathic surgery: A case report with long-term imaging follow-up

  • Hak-Sun, Kim;Sang-Sun, Han;Chena, Lee
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.409-413
    • /
    • 2022
  • This report presents a rare case where a displaced temporomandibular joint (TMJ) disc was reduced to its normal position after orthognathic surgery, and long-term magnetic resonance imaging (MRI) follow-up visualized these postoperative changes. A 22-year-old male patient presented for facial asymmetry. He also complained of pain in the right TMJ area, and MRI showed disc displacements in both TMJs. After orthognathic surgery for facial asymmetry correction, the TMJ was re-evaluated. The symptom had resolved and the disc was positioned within the normal range during mouth opening. However, 6 and a half years after surgery, he complained of recurrent pain in the right joint, and MRI revealed medial disc displacement in the right TMJ. In conclusion, the influence of orthognathic surgery on the disc position might continue for a long time until the TMJ adapts to the new position. Careful and long-term follow-up is suggested to assess the TMJ complex.

Design and Performance Evaluation of the Vibration Absorber of Vertical Direction Using Numerical Simulation and Shock Test (수치적 시뮬레이션과 충격 시험을 통한 수직방향 진동절연 완충기 설계 및 성능 평가)

  • Park, Sang-Gil;Bang, Seung-Woo;Kwon, O-Cheol;Lee, Jung-Youn;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.5
    • /
    • pp.558-563
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc' spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock Isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing $h_o/t$ ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.

Performance Evaluation of the Vibration Absorber of Vertical Direction using Numerical Modeling and Shock Test (수치 모델링과 충격 시험을 통한 수직방향 진동절연 완충기의 성능 평가)

  • Park, Sang-Gil;Bang, Seung-Woo;Kwon, O-Cheol;Lee, Jung-Youn;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.990-993
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc'spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing ho/t ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.

  • PDF

Appropriate Block Level in Neurolytic Lumbar Sympathetic Ganglion Block (신경파괴적 요부교감신경절 차단의 적정 부위)

  • Kim, Hee-Jung;Lee, Cheol-Oh;Shin, Yang-Sik;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.199-206
    • /
    • 2001
  • Background: The lumbar sympathetic ganglia are variable in both position and numbers. The aim of this study was to detect the appropriate lumbar vertebral level where the lumbar sympathetic ganglia primarily aggregate. Methods: Forty patients comprising of hyperhidrosis (26 cases), complex regional pain syndrome (10 cases), peripheral artery occlusion disease (3 cases) and postherpetic neuralgia (1 case) underwent lumbar sympathetic block. We randomly selected one of two (L2 or L3) levels and the L4 level. The position of the needle tip and distribution of dye was verified by injection of a mixture of radio-opaque dye (1.5 ml) and 4% lidocaine (1.5 ml) and subsequently confirmed by L-spine anteroposterior and a lateral view X-ray. We considered the response positive when the skin temperature increased more than $1^{\circ}C$ in 5 min. Results: In general, the positive response ratio was greater when the needle tip located at the L2 or L4 level vice L3 and when the drug was distributed on the lower half of the L4 body and in the L4/5 intervertebral disc space. In a right side block, the positive response ratio was greater when the drug was distributed on the lower half of the L4 body and in the L4/5 intervertebral disc space, although in a left side block there was no significant difference seen between the levels. The complications of the neurolytic block were alcohol neuritis (7.5%) and hypoesthesia (5%) on the L1 or L2 dermatome. Conclusions: The best effect with least chance of complication may be induced by spreading the drug on the lower half of the L4 body and/or into the L4/5 intervertebral disc space by placing the needle tip on the L4 body.

  • PDF

ENAMEL SURFACE EVALUATION ON VARIOUS REMOVAL TECHNIQUE OF BRACKET (DBS): A STUDY WITH THE SCANNING ELECTRON MICROSCOPY (수종의 BRACKET(DBS)제거방법에 따른 법랑질 표면에 대한 주사전자현미경적 연구)

  • Song, Jung-Kook;Sohn, Byung-Hwa
    • The korean journal of orthodontics
    • /
    • v.15 no.2
    • /
    • pp.271-277
    • /
    • 1985
  • With modification of the acid etch technique and improvements of the physical and mechanical properties of the acrylic resin, the removal of directly bonded attachments and the finishing of the underlying enamel have become an acute clinical problem. This study was to evaluation the efficacy of recently introduced instrumentation and techniques to remove bonded brackets and residual resin, and restore the affected enamel surface to an acceptable clinical condition. Fortyeight premolar which were scheduled for extraction for orthodontic purposes were bonded with brackets using super-C ortho. Four additional premolars with untreated surfaces were used as controls. After one weak the brackets were removed and the residual resin removed by hand scaler, green stone, green rubber wheel, sandpaper disc, tungsten carbide bur, Sof-lex disc. Half the experimental teeth were given a final pumicing and then all were extracted and stored in 50 percent ethanol. The scanning electron microscopy was used to evaluated the enamel surface. Following results were obtained; 1. A satisfactory result was obtained by means of the Sof-lex disc. 2. The order of the scratch formation was the procedure using hand scaler, green atone, tungsten carbide bur, sandpaper disc, green rubber wheel, and Sof-lex disc. 3. The procedures using green stone and tungsten carbide bur showed many groove formations and the other procedures showed none. 4. final pumicing serves effectively to remove residual adhesive and restore the enamel surface.

  • PDF

The Clinical Analysis of Short Hospitalization for Patients with Lumbar Disc Herniation (요추 추간판 탈출증 환자의 단기 입원에 대한 임상적 분석)

  • Lim, Byung-Cheol;Song, Jun-Hyeok;Park, Hyang-Kwon;Shin, Kyu-Man;Park, Dong-Been;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.242-246
    • /
    • 2001
  • Objective : The short hospitalization or outpatient care for patients undergoing laminectomy is not popular practice in Korea. We evaluated the clinical and economical significance of short hospitalization for patients undergoing microdiscectomy for their lumbar disc herniation. Material and Methods : From March 1999 to December 2000, patients were hospitalized for intended short period hospitalization for lumbar disc surgery. Their radiological and clinical data were analyzed for their clinical and economical results. We compared these data with 20 patients who hospitalized conventionally. Results : Total of 64 patients were evaluated. Three were lost to follow-up. Mean postoperative hospitalization period is 2.0 days(excluding one patient). Excellent to good outcome was achieved in 90.6 % of the patients. They payed about half expenses for hospitalization compared with conventional group. Their mean number of outpatient visit was 3.0. Conclusion : Short hospitalization for lumbar disc surgery is an acceptable option in Korea. It is also economically beneficial while achieving acceptable clinical results.

  • PDF

Design Optimization to achieve an enhanced flatness of a Lab-on-a-Disc for liquid biopsy (액체생검용 Lab-on-a-Disc의 평탄도 향상을 위한 최적화)

  • Seokkwan Hong;Jeong-Won Lee;Taek Yong Hwang;Sung-Hun Lee;Kyung-Tae Kim;Tae Gon Kang;Chul Jin Hwang
    • Design & Manufacturing
    • /
    • v.17 no.1
    • /
    • pp.20-26
    • /
    • 2023
  • Lab-on-a-disc is a circular disc shape of cartridge that can be used for blood-based liquid biopsy to diagnose an early stage of cancer. Currently, liquid biopsies are regarded as a time-consuming process, and require sophisticated skills to precisely separate cell-free DNA (cfDNA) and circulating tumor cells (CTCs) floating in the bloodstream for accurate diagnosis. However, by applying the lab-on-a-disc to liquid biopsy, the entire process can be operated automatically. To do so, the lab-on-a-disc should be designed to prevent blood leakage during the centrifugation, transport, and dilution of blood inside the lab-on-a-disc in the process of liquid biopsy. In this study, the main components of lab-on-a-disc for liquid biopsy are fabricated by injection molding for mass production, and ultrasonic welding is employed to ensure the bonding strength between the components. To guarantee accurate ultrasonic welding, the flatness of the components is optimized numerically by using the response surface methodology with four main injection molding processing parameters, including the mold & resin temperatures, the injection speed, and the packing pressure. The 27 times finite element analyses using Moldflow® reveal that the injection time and the packing pressure are the critical factors affecting the flatness of the components with an optimal set of values for all four processing parameters. To further improve the flatness of the lab-on-a-disc components for stable mass production, a quarter-disc shape of lab-on-a-disc with a radius of 75 mm is used instead of a full circular shape of the disc, and this significantly decreases the standard deviation of flatness to 30% due to the reduced overall length of the injection molded components by one-half. Moreover, it is also beneficial to use a quarter disc shape to manage the deviation of flatness under 3 sigma limits.

  • PDF

Preservation of Motion at the Surgical Level after Minimally Invasive Posterior Cervical Foraminotomy

  • Lee, Young-Seok;Kim, Young-Baeg;Park, Seung-Won;Kang, Dong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.433-440
    • /
    • 2017
  • Objective : Although minimally invasive posterior cervical foraminotomy (MI-PCF) is an established approach for motion preservation, the outcomes are variable among patients. The objective of this study was to identify significant factors that influence motion preservation after MI-PCF. Methods : Forty-eight patients who had undergone MI-PCF between 2004 and 2012 on a total of 70 levels were studied. Cervical parameters measured using plain radiography included C2-7 plumb line, C2-7 Cobb angle, T1 slope, thoracic outlet angle, neck tilt, and disc height before and 24 months after surgery. The ratios of the remaining facet joints after MI-PCF were calculated postoperatively using computed tomography. Changes in the distance between interspinous processes (DISP) and the segmental angle (SA) before and after surgery were also measured. We determined successful motion preservation with changes in DISP of ${\leq}3mm$ and in SA of ${\leq}2^{\circ}$. Results : The differences in preoperative and postoperative DISP and SA after MI-PCF were $0.03{\pm}3.95mm$ and $0.34{\pm}4.46^{\circ}$, respectively, fulfilling the criteria for successful motion preservation. However, the appropriate level of motion preservation is achieved in cases in which changes in preoperative and postoperative DISP and SA motions are 55.7 and 57.1%, respectively. Based on preoperative and postoperative DISP, patients were divided into three groups, and the characteristics of each group were compared. Among these, the only statistically significant factor in motion preservation was preoperative disc height (Pearson's correlation coefficient=0.658, p<0.001). The optimal disc height for motion preservation in regard to DISP ranges from 4.18 to 7.08 mm. Conclusion : MI-PCF is a widely accepted approach for motion preservation, although desirable radiographic outcomes were only achieved in approximately half of the patients who had undergone the procedure. Since disc height appears to be a significant factor in motion preservation, surgeons should consider disc height before performing MI-PCF.