• Title/Summary/Keyword: HYSYS

Search Result 60, Processing Time 0.034 seconds

Preliminary study and development of $kW_e$-class liquid fuel based SOFC system (액상 연료 용 $kW_e$급 SOFC 시스템 사전 연구 및 개발)

  • Yoon, Sang-Ho;Kim, Sun-Young;Bae, Joong-Myeon;Baek, Seung-Whan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.21-24
    • /
    • 2008
  • We have developed a $kW_e$ class liquid fuel based solid oxide fuel cell (SOFC) system. Our final target is to develop the 1 $kW_e$ diesel based SOFC system for residential power generator(RPG). In this study, we present the conceptual design of SOFC system. System is composed of hot-box and cold-box. Planar typed SOFC stack, heat exchanger, combustor for stack tail gas, and fuel processor, such as fuel reformer and desulfurizer, are contained in the hot-box. And several balance of plants(BOP), such as fuel suppliers and controller, are contained in the cold-box. Before the SOFC system fabrication, we have already operated the selfsustaining fuel processor, and heat exchange of all heat-related components is simulated using ASPEN HYSYS, because heat maintenance and management in hot-box are important for stable operation of SOFC system. The self-sustained fuel processor was successfully operated for about 250 hours, and heat exchange is enough to operate the SOFC system.

  • PDF

Application of An Energy-Efficient Distillation System using Three Columns to Hexane Process (3기의 증류탑을 이용한 에너지 절약형 증류탑의 헥산공정에의 응용)

  • Kim, Young-Han;Hwang, Kyu-Suk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.39-46
    • /
    • 2005
  • Though a fully thermally coupled distillation column-an energy efficient distillation system-consumes less energy, it is not widely implemented in practice due to its operational difficulty. A 3-column distillation system having improved operability is proposed here, and its energy saving performance and application related issues are investigated from the implementation result to a practical hexane process. When an energy integration is employed, the proposed system requires 18% less energy than a conventional 2-column system, which is found from the HYSYS simulation. Though more control loops than the 2-column system are required, the proposed system has better controllability of product compositions and the pressure control of the system is easier.

Study on Control Efficiency of Fully Thermally Coupled Distillation Column for BTX Separation (BTX 분리용 열복합 증류탑의 제어성능에 관한 연구)

  • Kim, Mi Hee;Park, Chang Won;Lee, Ju-Yeong;Kim, Young Han;Hwang, Kyu Suk
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.725-730
    • /
    • 2010
  • The fully thermally coupled distillation columns(FTCDC) are thermodynamically more efficient than conventional columns. Despite these advantages, industry has been reluctant to use FTCDC. This can be largely attributed to the lack of established design procedures and column operability. In this study, the $3{\times}3$control structure was applied to control the FTCDC which was simulated using Aspen HYSYS on the possible control structure of 4 kinds and control performance was investigated. As the result of dynamic simulations, one of the proposed structures had better controllability of product compositions and control efficiency was evaluated.

Performance Simulation of BOG Reliquefaction System for Dual Fuel Engine of LNG Carrier (LNG 선박 Dual Fuel 엔진용 BOG 재액화 시스템의 성능 시뮬레이션)

  • Lee, Sang-Hoon;Shin, You-Hwan;Lee, Yoon-Pyo;Yoo, Ho-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.148-153
    • /
    • 2008
  • As the oil price is dramatically jumping up, the consumption of LNG is rapidly expanding and the size of LNG carriers becomes bigger. For LNG ships, the application of DF (Dual-Fuel) engines gradually increases because of high efficiency, which alternatively use diesel or BOG (Boil-Off Gas) from cargo tank as a fuel. The surplus BOG from LNG cargo tank should be exhausted by GCU or liquefied through the BOG reliquefaction system and returned back. This study focused into its operational characteristics through the process simulation using HYSYS and discussed details on the influence of the variations of some operational parameters such as a distribution ratio by the change of fuel mass flow into the DF engine.

  • PDF

Performance Analysis of WHR-ORC Using Hydrocarbon Mixtures for 20kW Gross Power at Low Temperature

  • Kwakye-Boateng, Patricia;Yoon, Jung-In;Son, Chang-Hyo;Hui, Kueh Lee;Kim, Hyeon-Uk
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.140-145
    • /
    • 2014
  • Exploitation of renewable energies is on the increase to mitigate the reliance on fossil fuels and other natural gases with rocketing prices currently due to the depletion of their reserves not to mention their diverse consequences on the environment. Divergently, there are lots of industries "throwing" heat at higher temperatures as by products into the environment. This waste heat can be recovered through organic Rankine systems and converted to electrical energy with a waste heat recovery organic Rankine cycle system (WHR-ORC). This study uses the annual average condenser effluent from Namhae power plant as heat source and surface seawater as cooling source to analyze a waste heat recovery organic Rankine cycle using the Aspen HYSYS simulation software package. Hydrocarbon mixtures are employed as working fluid and varied in a ratio of 9:1. Results indicate that Pentane/Isobutane (90/10) mixture is the favorable working fluid for optimizing the waste heat recovery organic Rankine cycle at the set simulation conditions.

Effect on Heat Exchangers Efficiency on Performance of Cryogenic Refrigeration Cycles (열교환기 효율이 초저온 냉동사이클 성능에 미치는 영향)

  • Yoon, Jung-In
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.58-63
    • /
    • 2013
  • This paper presents the new cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$. The performance of the cascade liquefaction cycles with respect to temperature differences in the LNG heat exchangers is analyzed using HYSYS software and then compared the performance of these cycles with phillips optimized cascade liquefaction cycle. The coefficient of performance of the new liquefaction cycles considered in this study decreases with the temperature differences in the LNG heat exchangers, but the compressor work, expander work and heat capacity in the LNG heat exchanger increases, respectively. From the comparison of performance of three cycles, the cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ showed the highest COP. And the cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$ presented the second and third highest COP, respectively. In the view of performance, the optimized cascade liquefaction cycle using $C_3H_8-C_2H_4-C_1H_4$ yields much better COP. But, in the environment view, it is found that the cascade liquefaction cycle using $CO_2-C_2H_6-N_2$ shows favorable characteristics.

A Study on the Engineering Design for 250kW-Grade Waste Gas Heat Recovery (250kW급 폐열회수 시스템 공정설계에 관한 연구)

  • Kim, Kyoung Su;Bang, Se Kyoung;Seo, In Ho;Lee, Sang Yun;Jeong, Eun Ik;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.90-95
    • /
    • 2019
  • This study aims to gain the design data through the process design of the organic Rankine cycle, which can produce 250kW of electric power through waste heat recovery. In this study, a simulation was conducted using APSEN HYSYS to make the model for the process design of the 250kW-class waste heat recovery system. For the thermodynamic model, the test was conducted with hot water as the heat source, the water steam as the cooling water for the cooler, and the refrigerant R245FA in the cycle. In the final design, it was expected and found from the simulation that the cycle efficiency was 12.62% and that 250kW of power was produced considering the margin of 80%.

A Preliminary Study on Direct Ethanol SOFC for Marine Applications

  • Bo Rim Ryu;To Thi Thu Ha;Hokeun Kang
    • Journal of Navigation and Port Research
    • /
    • v.48 no.2
    • /
    • pp.125-136
    • /
    • 2024
  • This research presents an innovative integrated ethanol solid oxide fuel cell (SOFC) system designed for applications in marine vessels. The system incorporates an exhaust gas heat recovery mechanism. The high-temperature exhaust gas produced by the SOFC is efficiently recovered through a sequential process involving a gas turbine (GT), a regenerative system, steam Rankine cycles, and a waste heat boiler (WHB). A comprehensive thermodynamic analysis of this integrated SOFC-GT-SRC-WHB system was performed. A simulation of this proposed system was conducted using Aspen Hysys V12.1, and a genetic algorithm was employed to optimize the system parameters. Thermodynamic equations based on the first and second laws of thermodynamics were utilized to assess the system's performance. Additionally, the exergy destruction within the crucial system components was examined. The system is projected to achieve an energy efficiency of 58.44% and an exergy efficiency of 29.43%. Notably, the integrated high-temperature exhaust gas recovery systems contribute significantly, generating 1129.1 kW, which accounts for 22.9% of the total power generated. Furthermore, the waste heat boiler was designed to produce 900.8 kg/h of superheated vapor at 170 ℃ and 405 kP a, serving various onboard ship purposes, such as heating fuel oil and accommodations for seafarers and equipment.

Study of LNG Reliquefaction Process in LNG Carriers (LNG 선박에서 천연가스 재액화공정의 재액화량에 관한 연구)

  • Ko, Byoung-Seok;Kim, Bum-Su;Lee, Heon-Seok;Kang, Yun-Jin;Kim, Min-Seop;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.21-27
    • /
    • 2010
  • In the past vaporized gases from a carrier were burned or used for fuel. Due to the movement of bigger LNG carriers and using diesel engine, it is limited that ways of deposing vaporizes gases from the carrier by the act of environment. For getting over the problem, a reliquefaction process is considered. Even though the reliquefaction process was created to three generation process, it has been researched and developed to optimize the process. Basically the reliquefaction process is compartmentalized into Reverse Brayton Cycle System and Claude Cycle System. This research is focused on the reliquefaction efficiency with the systems and changing equipments arrangement by using HYSYS. The result could be use for a design of a reliquefaction process.

Study on the Comparison of New and Used Reliquefaction System of Boil-Off-Gas by LNG Cold Energy (냉열을 이용한 LNG 증발기체 BOG 재액화 신공정과 기존공정에 관한 비교연구)

  • Lee, Dong-Hyuck;Jang, Chang-Bong;Jung, Sang-Yong;Kim, Jung-Hwan;Lee, Heon-Seok;Kim, Bum-Su;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.42-46
    • /
    • 2010
  • BOG(Boil Off Gas) is formed about 0.05 vol%/day from LNG(Liquefied Natural Gas) tanks of LNG receiving terminal. To recycle the BOG using direct contacting, Previously the quantities of LNG and BOG is mixed at the ratio of 11:1 by mass. However simple this process uses, there is the difficulty of processing operation resulted from decrease of using LNG in summer. To complement these shortcomings, Advantages of the process are investigated by comparison of cost and analysis of the indirect contact method using LNG cold energy. It was studied that principles and types of development using LNG cold energy which is abandoned in the carburettor and found how to contact each to find the appropriate cold energy development process. Therefore, in this research, the indirect contact method will be investigated the feasibility of a comparative analysis by using HYSYS.