• Title/Summary/Keyword: HVDC System

Search Result 377, Processing Time 0.026 seconds

Design of Emotional Learning Controllers for AC Voltage and Circulating Current of Wind-Farm-Side Modular Multilevel Converters

  • Li, Keli;Liao, Yong;Liu, Ren;Zhang, Jimiao
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2294-2305
    • /
    • 2016
  • The introduction of a high-voltage direct-current (HVDC) system based on a modular multilevel converter (MMC) for wind farm integration has stimulated studies on methods to control this type of converter. This research article focuses on the control of the AC voltage and circulating current for a wind-farm-side MMC (WFS-MMC). After theoretical analysis, emotional learning (EL) controllers are proposed for the controls. The EL controllers are derived from the learning mechanisms of the amygdala and orbitofrontal cortex which make the WFS-MMC insensitive to variance in system parameters, power change, and fault in the grid. The d-axis and q-axis currents are respectively considered for the d-axis and q-axis voltage controls to improve the performance of AC voltage control. The practicability of the proposed control is verified under various conditions with a point-to-point MMC-HVDC system. Simulation results show that the proposed method is superior to the traditional proportional-integral controller.

Modelling development of the Electromagnetic Transient Analysis of the JeJu Power System (제주 전력계통의 전자기과도해석 모델링 개발)

  • Choi, Joon-Ho;Nam, Hae-Kon;Nam, Soon-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.223-225
    • /
    • 2008
  • 본 논문은 제주 계통의 전자기적 과도 해석을 위해 상세한 전자기 과도해석 모델링 개발 및 절차에 관한 내용을 다루고 있다. 제주 전력계통의 모델링은 크게 제주도내의 화력발전 모델링과 육지와 연계된 해남-제주간 Bi-pole HVDC 모델링으로 구분하여 개발하였고 이를 통합하였다. 모델링의 정확성 확보를 위해 기존에 개발된 PSS/E 모델링과 비교하여 개발하였다. 사례연구로는 HVDC상세 모델과 제주 AC 전력계통을 통합한 과도해석 모델을 사용하여 부하 급변등, 사고해석 등을 사례연구를 수행하였다.

  • PDF

Northeast Asia Interconnection and Regional Reserve Increase Effects (동북아 연계선로 구성 및 지역별 예비력 증가 효과)

  • Lee, Sang-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.417-419
    • /
    • 2005
  • This paper presents the effects and the regional power distribution of an increase or a decrease of a power reserve by load flow calculations under seasonal load patterns of each country for the future power shortages faced by the metropolitan areas or by the southeastern area of the South Korea in North-East Asia. In these connections, the types of a power transmission for interconnection consist of the 765kV HVAC and the HVDC. In this paper, the various cases of the power system interconnections in Far-East Asia are presented, and the resulting interconnected power systems are simulated by means of a power flow analysis performed with the PSS/E 28 version tool. The power flow map is drawn from data simulated and the comparative study is done. In this future, a power flow analysis will be considered to reflect the effects of seasonal power exchanges And the plan of assumed scenarios will be considered with maximum or minimum power exchanges during summer or winter in North-East Asia countries.

  • PDF

Controller of the Capacitor Commutated Converter for Hvdc

  • Tsubota, Shinji;Funaki, Tsuyoshi;Matsuura, Kenji
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.914-919
    • /
    • 1998
  • A Capacitor Commutated Converter (CCC) has less difficulty of commutation failure in comparison to the conventional line commutated converter. This paper proposes the Ar1R control of the CCC in the inverter operation, which deserves as the Ar1R of the conventional converter. The CCC can be operated in high power factor area by using the proposing Ar1R control. The voltage stability at an AC bus connected the CCC inverter is investigated and estimated its ability of preventing the AC voltage collapse. To estimate the voltage stability, this paper developed the simplified converter mathematical model and led the VSF index. The results shows that the AC voltage stability is guaranteed and enables the interconnection to an weak AC system, when compensation factor of the compensation capacitor is higher than 200%.

  • PDF

A Study on the Performance Enhancement of HVDC System Using Hybrid Filter and Energy Recovery Filter (11차/13차 고조파를 동시에 제거하는 Single Tuned 필터)

  • Kim C.K.;Yang B.M.;Jeong G.J.;Ahan J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.717-721
    • /
    • 2003
  • Two non-conventional HVDC converter arrangements are compared. These include the Capacitor Commutated Converter (CCC) in which series capacitors are included between the converter transformer and the valves, and the Controller Series Capacitor Converter (CSCC), based on more conventional topology, in which series capacitors are inserted between the AC filter bus and the AC network. Results show that both options have comparable steady state and transient performance. Danger of ferroresonance with the CSCC option is eliminated by controlling the amount of series compensation. The dynamic performance simulations is peformed by PSCAD/EMTDC

  • PDF

Multi-physics Analysis for Temperature Rise Prediction of Power Transformer

  • Ahn, Hyun-Mo;Kim, Joong-Kyoung;Oh, Yeon-Ho;Song, Ki-Dong;Hahn, Sung-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.114-120
    • /
    • 2014
  • In this paper, a method for multi-physics analysis of the temperature-dependent properties of an oil-immersed transformer is discussed. To couple thermal fields with electromagnetic and fluid fields, an algorithm employing a user defined function (UDF) is proposed. Using electromagnetic analysis, electric power loss dependent on temperature rise is calculated; these are used as input data for multi-physics analysis in order to predict the temperature rise. A heat transfer coefficient is applied only at the outermost boundary between transformer and the atmosphere in order to reduce the analysis region. To verify the validity of the proposed method, the predicted temperature rises in high-voltage (HV) and low-voltage (LV) windings and radiators were compared with the experimental values.

A Study on Improvement of Powerfactor and Source Waveform Converter System of Power Supply for HVDC Transmission (HVDC 송전을 위한 전원용 컨버터 시스템의 역률 및 파형개선에 관한 연구)

  • Hwang, Lak-Hoon;Lee, Chun-Sang;Lee, Sang-Yong;Na, Seng-Kwon;Cho, Moon-Taek
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.395-397
    • /
    • 1999
  • This paper presents a method of improving the power factor and the waveform of A.C line currents and the out waveforms of AC to DC fully bridge converter systems which is achieved by connecting converters in series and parallel. The results of simulation show that the power factor and the source voltage and current waveforms are improved by the method of connecting converter in series, and the controlled input voltage and current waveform using a current limit controller.

  • PDF

Study on 36-pulse Back-to-Back Voltage Source Converter with Pulse-Interleaving Auxiliary Circuit for HVDC Application (펄스다중화 보조회로를 이용한 36-펄스 Back-to-Back 전압원 컨버터의 직류송전 적용연구)

  • Baek, Seung-Taek;Choi, Jun-Young;Han, Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.3
    • /
    • pp.102-108
    • /
    • 2006
  • This paper proposes a 36-pulse back-to-back voltage source converter using four sets of 12-pulse bridges with pulse-Interleaving auxiliary circuit. The proposed back-to-back voltage source converter has an independent control capability of active power and reactive power at the at connection point. The principle of increasing the number of pulses was analyzed using theoretical approach. The operational feasibility of proposed system was verified through computer simulations with PSCAD/EMTDC software. The proposed back-to-back converter can be widely used for the HVDC and FACTS devices.

Electrical characteristics simulation of thyristor devices for HVDC transmission (HVDC용 사이리스터 소자의 전기적 특성 simulation 연구)

  • Kim, Sang-Cheol;Seo, Kil-Soo;Kim, Eun-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1559-1561
    • /
    • 2003
  • In northeast Asia, there will be several important HVDC transmission lines to be established in Korea and China for perspective electric network market. 5500V 4-inches High voltage thyristor can be used in the DC transmission and distribution of electric power system. In this application, many thyristors are connected in series for each thyristor valves. Therefore, the required low reverse-recovery charge QRR and low on-state voltage drop $V_{TM}$ for such thyristor is necessary to this application. In our work, the on-state and off-state voltage performance was simulated by commercial simulation software.

  • PDF

Economic Considerations Underlying the Adoption of HVDC and HVAC for the Connection of an Offshore Wind Farm in Korea

  • Hur, Don
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.157-162
    • /
    • 2012
  • Wind energy is created in mega-sized wind farms situated kilometers off shore. In fact, two possibilities are considered for the transmission system between the offshore wind farm and the onshore grid: high-voltage direct current and high-voltage alternating current. From this point of view, the current paper aims to compare both systems for a 2 GW wind farm situated 80 km from the Point of Common Coupling on an economic basis using a discounted cash flow analysis. A tool is developed in Microsoft Excel to allow for quick insight in the variation of input parameters.