• Title/Summary/Keyword: HVDC System

Search Result 377, Processing Time 0.033 seconds

Mechanical Strength Calculation of HVDC Valve Hall (HVDC시스템 밸브홀의 기계적 강도 계산)

  • Kim, Chan-Ki;Lee, Seong-Do;Kang, Ji-Won;Yoon, Yong-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.442-448
    • /
    • 2016
  • This paper presents electromagnetic force effect of the conductor and insulator in the HVDC valve hall. This paper is based on IEC 60865, which is applicable to the mechanical and thermal effects of short-circuit currents. The paper contains procedures for the calculation of the electromagnetic effect on HVDC conductors and flexible conductors, as well as the thermal effect on HVDC conductors. The results are applied to the Godeok -Dangjin HVDC system.

Test of MMC HVDC Control System using Hardware-in-the-Loop Simulation (HILS를 이용한 MMC HVDC 제어 시스템 시험)

  • Lee, Dong-Gyu;Lee, Jun-Chol;Choi, Jong-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.339-340
    • /
    • 2015
  • 본 논문에서는 HVDC 제어 시스템의 기능 검증을 위해 구축한 RTDS 기반의 HILS(Hardware-In-the Loop Simulation)시스템 및 시험 결과를 소개하였다. MMC 기반 VSC HVDC는 다수의 직렬 연결된 SM(Sub-Module)을 개별 제어해야 하므로 기존의 LCC HVDC 및 2/3-Level 컨버터 기반의 VSC HVDC와 같은 설비들보다 훨씬 더 복잡한 VBE 구조를 가지고 있다. 또한 짧은 시간 내에 정밀한 제어가 가능해야 하므로 높은 제어 정밀도가 요구된다. (주)효성에서는 제어 시스템의 성능 검증을 위해 RTDS 기반의 HILS(Hardware-In-the Loop Simulation)시스템을 구축하였으며, 이를 이용하여 HVDC 제어 시스템의 성능 시험을 수행하였다. 본 논문에서는 구축된 RTDS 기반의 HILS 시스템 및 시험 결과를 소개하였다.

  • PDF

Analysis of Acoustic Noise Characteristics of Jindo-Cheju HVDC (진도-제주 HVDC 변환설비 소음특성 분석)

  • Kim, Jae-Han;Kim, Chan-Ki;Lee, Seong-Doo;Kim, Jin-Young
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.574-576
    • /
    • 2010
  • HVDC converter station consists of a number of noise sources such as converter transformer, ac filter, cooling system and so on. In this paper, we analyzed the simulation results of the outdoor acoustic noise characteristics for HVDC converter station. It shows that maximum noise level in boundary of HVDC converter station exceeds regulation value. The main factors in generating maximum noise level are ac filter and converter transformer. Then we applied some soundproof countermeasure in HVDC converter station. Shielding wall is enough to reduce transformer noise level but not enough to reduce ac filter noise level. In case of ac filter, soundproof building is effective in satisfying noise level regulation in boundary of HVDC converter station. In addition, we also studied effects of season, soundproof woods, ground.

  • PDF

A Fault Location Algorithm Using Wavelet Transformation for HVDC Cables (웨이블렛 변환을 이용한 HVDC 케이블 고장점 표정 알고리즘)

  • Kwon, Young-Jin;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1311-1317
    • /
    • 2008
  • In this paper, a fault location algorithm using wavelet transform is proposed for HVDC cable lines. The arriving instants of the first and second fault-induced backward travelling waves can be detected by using wavelet transform. The fault distance is estimated by using the time difference between the two instants of backward travelling waves and the velocity of the travelling wave. To distinguish between the backward wave from fault point and the backward wave from the remote end, polarities of backward waves are used. The proposed algorithm is verified varying with fault distances and fault resistances in underground cables of VSC(voltage source converter) HVDC system and CSC(Current Source Converter) HVDC respectively. Performance evaluations of the proposed algorithm shows that it has good ability for a fault location of HVDC cable faults.

Development of HVDC 500kV PPLP MI cable systems in Korea (HVDC 500kV PPLP MI 케이블시스템 개발)

  • Lee, Soo-bong;Cho, Dong-sik;Lee, Tae-ho;Kim, Sung-yun;Lee, Su-kil;Jeon, Seung-ik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1202-1203
    • /
    • 2015
  • This paper describes the development of HVDC ${\pm}500kV$ polypropylene laminated paper (PPLP) mass-impregnated (MI) type cable system for HVDC transmission lines. As you know, mass-impregnated type cable generally has only insulating layer with the Kraft paper impregnated with a high-viscosity insulating compound. But polypropylene laminated paper is made of a layer of extruded polypropylene (PP) film sandwiched between two layers of Kraft paper. Thanks to PP film and its combination with Kraft paper, PPLP has higher AC, Impulse (Imp.) and DC breakdown (BD) strengths as well as lower dielectric loss than conventional Kraft paper insulation. In addition, Kraft MI cable has a limitation for the maximum conductor temperature as $55^{\circ}C$ But this PPLP MI cable has higher maximum conductor temperature than that of Kraft MI cable due to advantage of oil drainage characteristics. It is the most economic type of cable for HVDC transmission. Also HVDC ${\pm}500kV$ PPLP MI cable system was developed including land joints and outdoor-terminations. In order to prove the mechanical and electrical performances, the type test was carried out according to CIGRE recommendations. A full scale cable system has been tested successfully. And additional load cycle and polarity reversal tests on the cable system showed a higher performance compared with a similar mass impregnated paper cable.

  • PDF

Control of a VSC-HVDC Transmission System based on Modular Multilevel Converters (모듈형 멀티레벨 컨버터로 구성된 고압직류 송전시스템의 제어)

  • Cui, Shenghui;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.341-342
    • /
    • 2014
  • VSC-HVDC system based on Modular Multilevel Converter (MMC) is an emerging technology since compared to the conventional VSC-HVDC system an MMC presents several advantages such as modularity, low dv/dt, low harmonics, and low switching losses. In this paper, a comprehensive control strategy of an MMC-based VSC-HVDC system is proposed. In contrast to the conventional system control strategy, the DC side of the MMC operates as a controlled voltage source by the proposed method, and the dynamics of the transmission line voltage and current can be actively controlled. Validity of the proposed strategy was verified by 201-level full-scale computer simulation.

  • PDF

Study of Electrode Cracking in High Voltage Direct Current System (초고압 직류 설비의 전극봉 부식원인에 대한 연구)

  • Park, Jong-Kwang;Kim, Chan-Ki;Yang, Byoung-Mo;Choy, Young-Do;Han, Byeong-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.525-526
    • /
    • 2006
  • One of the electrode in Haenam converter, which is role of rectifier in Jeju-Haenam HVDC system is destroyed and we found many cracks at another electrode and we also found many cracks in Jeju converter station, which is role of inverter of Jeju-Haenam. HVDC system, there is no exact reason for these phenomenon, even though the life cycle of these electrode is 40 years. So, the experts for HVDC system in KEPCO and Anotec corporation, which is manufacturer of electrode, would perform research for the reason of electrode disorder. In this paper analyze the reason of electrode disorder and corrosion in high voltage direct current system.

  • PDF

A Study of Circulating Current in MMC based HVDC System under an Unbalanced Grid Condition (불평형 전원 조건에서 MMC 기반 HVDC 시스템 순환전류에 관한 연구)

  • Do, Won-Seok;Kim, Si-Hwan;Kim, Tae-Jin;Kim, Rae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1193-1201
    • /
    • 2015
  • This paper presents a study of circulating current of modular multi-level converter (MMC) based a high voltage direct current (HVDC) system under unbalanced grid conditions. Due to the connection of a dependent DC source in each phase, the MMC system inherently generates the power ripple of double-line-frequency components in the AC-side and as a result, the additional sinusoidal current named circulating current flows through the each arm. Reliability improvement of HVDC system under an unbalanced grid condition is one of the important criteria. Generally, the modeling of the circulating current is based on the power relation between DC-side and AC-side. However, the method is not perfectly matched in the MMC system due to the difference of the structural characteristic. In this paper, improved modeling method of circulating current is proposed, which is based on the inner arm power. The proposed method is verified by several simulations to have good agreement of the circulating current components.

Design of Direct-Current Fuzzy Controller for Mitigating Commutation Failure in HVDC System

  • Gao, Benfeng;Yuan, Kewei;Dong, Peiyi;Luo, Chao;Zhao, Shuqiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1450-1458
    • /
    • 2018
  • Commutation failures can deteriorate the availability of high-voltage direct current (HVDC) links and may lead to outage of the HVDC system. Most commutation failures are caused by voltage reduction due to ac system faults on inverter side. The commutation failure process can be divided into two stages. The first stage, from the occurrence to the clearing of faults, is called 'Deterioration Stage'. The second stage, from the faults clearing to restoring the power system stability, is called 'Recovery Stage'. Based on the analysis of the commutation failure process, this paper proposes a direct-current fuzzy controller including prevention and recovery controller. The prevention controller reduces the direct current to prevent Commutation failures in the 'Deterioration Stage' according to the variation of ac voltage. The recovery controller magnifies the direct current to speed up the recovery of power system in the 'Recovery Stage', based on the recovery of direct voltage. The validity of this proposed fuzzy controller is further proved by simulation with CIGRE HVDC benchmark model in PSCAD/EMTDC. The results show the commutation failures can be mitigated by the proposed direct-current fuzzy controller.

Double-tuned Filter Design Applied to HVDC System and Assessment of Impedance Characteristic (HVDC System 적용 Double-tuned 필터의 설계 방법 및 임피던스 특성 검토)

  • Lee, Hee-Jin;Son, Gum-Tae;Nam, Tae-Sik;Baek, Seung-Taek;Lee, Uk-Wha;Jung, Yong-Ho;Hur, Kyeon;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.207-208
    • /
    • 2011
  • 세계적으로 대용량 장거리 송전에 대한 요구가 증가함에 따라 HVDC(High Voltage Direct Current) 시스템에 관심이 집중되고 있다. 대규모 전력전송이 가능한 전류형 HVDC 시스템은 무효전력 및 고조파를 발생시킨다. 따라서 이를 보상하기 위해 여러 종류의 AC필터가 사용된다. 본 논문에서는 HVDC 시스템에서 주로 사용되는 double-tuned 필터의 두 가지 설계방식을 검토한다. 또한 저항을 투입하여 공진을 줄이는 damped double-tuned 필터의 임피던스 특성을 살펴본다.

  • PDF