• 제목/요약/키워드: HVAC type

검색결과 48건 처리시간 0.025초

인지측면을 고려한 자동차 IP 설계 (Cognitive-oriented Design of Automotive Instrument Panel)

  • 강선모;백승렬;박범
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1987년도 춘계학술대회논문집
    • /
    • pp.143-148
    • /
    • 1987
  • The Design of automotive IP must be designed for improving safety, and for satisfying the consumer's preference and for enlarging the usability of various gauges and information displaydevices. Also, these objects become more important by regarded and will be treated very sensitively for the next-generation vehicle concepts. Therefore, Automotive IP must be designed to adjust these trends, besides accord with car-inner lifestyle. One of these concept's designs is to apply Human Sensibility Ergonomics. This study suggestes the driver-centered design of the IP components that focused on the audio unit and HVAC(Heat and Ventilation Air Conditioner) through cognitive experiment. Primarily, analyzed components of IP in use, then, combined these components (especially, the number and arry of buttons, the position of LCD panel, etc.) nd designed some sample images(prototypes) the same as real size. After the subjects looked at the sam ples at the interval of 0.2/0.4/0.6 seconds, subjects should fill out the given forms from their memory. Then, the optimal prototype of IP was designed in respect to the correctness of cognition. The results will show the basic guideline of optimal design of IP that in the case of aaudio unit, the position of LCD, the array and the number of channel, in the case of HVAC, the position of LCD, TEMP button type and other button types.

  • PDF

공조설비 온라인 유지관리시스템 개발 및 효과분석 (A Development of the On-line Maintenance and Management System for the HVAC Systems and the Evaluation of Its Effects)

  • 이태원;김용기;우남섭
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.591-598
    • /
    • 2009
  • The service quality with the various building equipments tends to depend on the individual superintendent's capability and efforts generally and this often lead to poor maintenances and managements of them. N-BMS(Networked Building Management System), proposed in this study, is a new type of building management method, which links principal equipments within many buildings into a communication network and carries out several significant missions such as fault detection, deterioration diagnosis and control the equipments and so on, as well as monitoring which is the main and unique purpose of the conventional BMS. How to construct the N-BMS was considered to keep performance of equipments high and thus to save energy and resource. LCC(Life Cycle Cost) based analysis was also performed in order to verify the effects of some maintenance and management works for the building HVAC systems.

무균돈사내 급배기구의 적정위치설정에 관한 연구 (A Study on the Proper Location of Ventilation Outlets and Inlets in the Germ Free Pigs' Room)

  • 권순정;손덕영;최윤호
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제14권4호
    • /
    • pp.39-46
    • /
    • 2008
  • Construction and operation of Germ Free Pigs' facilities are very expensive because pigs' rooms and other major rooms of the facility require germfree environments. Especially, running the HVAC system of aseptic facilities requires a lot of expenses. However, proper location and efficient shape of outlets/inlets for the ventilation of the room can reduce the excessive running cost. In order to do that, this study proposes alternative location and shape of ventilation outlets/inlets to the existing design pattern in germfree pigs' room. The design condition of this study is the maintenance of adequate temperature(24$^{\circ}C$, $NH_3$concentration level(below 1.5 ppm), and air stream speed(below .25m/sec) in the pigs' room for the summer and the winter together. As the Software Program, FLUENT(Ver. 6.2) has been used for the analysis of proposed ventilation patterns. In conclusion, wall inlets and ceiling inlet/outlet are advisable in summer, wall inlets and ceiling outlets is advisable in winter. As far as the shape is concerned, diffuser type for the ceiling outlet is desirable.

  • PDF

기획특집 - 초고층 설비설계사례 (HVAC System For Highriser Residential Bilding)

  • 노석남
    • 기술사
    • /
    • 제42권5호
    • /
    • pp.32-36
    • /
    • 2009
  • This project located in IFEZ(Incheon Free Economic Zone) is the first central heating and cooling type for high-rise residential building in korea. The design was performed as the joint venture between Cosentini from U.S.A and wooowon, and our design concept was to save energy. LEED application from USGBC is going on in progress for the first residential building in korea. Careful attention was paid from schematic design for not a durability of structural and architectural, but also durability and safety of M.E.P.

  • PDF

흡음재가 부착된 직방형 소음기의 전달 손실 예측 (Prediction of transmission loss of parallelepiped plenum chambers with liner)

  • 김회전;이정권;박철민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.383-386
    • /
    • 2003
  • This paper deals with transmission loss of 3-dimensional rectangular plenum lined chamber. There are three kinds of rectangular plenum lined chamber: throughflow type, flow-reversal type, and end-in/side-out type. The combination of above three types of rectangular plenum lined chamber is used for the commercial HVAC system and automobile exhaust system. However, the ambiguity and complexity of sound absorbing material property and 3-dimensional property have impeded research. In this paper, the transmission loss of three kinds of rectangular plenum lined chamber is derived and calculated. The effect of increase of sound absorbing material is also considered. Analytical solution is calculated by using the locally-reacting property of sound absorbing material.

  • PDF

에어컨시스템에 대한 계층적 공정 경쟁 유전자 알고리즘을 이용한 최적화된 다중 퍼지제어기 설계 (Design of Optimized Multi-Fuzzy Controllers by Hierarchical Fair Competition-based Genetic Algorithms for Air-Conditioning System)

  • 정승현;최정내;김현기;오성권
    • 제어로봇시스템학회논문지
    • /
    • 제13권4호
    • /
    • pp.344-351
    • /
    • 2007
  • In this paper, we propose an approach to design multi-fuzzy controllers for the superheat and the low pressure that have an influence on energy efficiency and stabilization of air conditioning system with multi-evaporators. Air conditioning system with multi-evaporators is composed of compressor, condenser, several evaporators and several expansion valves. It is quite difficult to control the air conditioning system because the change of the refrigerant condition give an impact on the overall air conditioning system. In order to solve the drawback, we design multi-fuzzy controllers which control simultaneously both three expansion valve and one compressor for the superheat and the low pressure of air conditioning system. The proposed multi fuzzy controllers are given as a kinds of controller types such as a simplified fuzzy inference type. Here the scaling factors of each fuzzy controller are efficiently adjusted by Hierarchical Fair Competition-based Genetic Algorithms. The values of performance index of the simulation results of the A company type compare with simulation results of simplified inference type.

사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성 (Characteristics of Energy Consumption in an Office Building located in Seoul)

  • 박병윤;정광섭
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

지열을 이용한 학교시설의 냉·난방시스템 효율성분석 -에너지 소비량을 중심으로- (Efficiency Analysis of the HVAC system in the School Facilities Using the Geothermal Energy -Focused on the energy consumption-)

  • 박동순;이재림
    • 교육녹색환경연구
    • /
    • 제6권2호
    • /
    • pp.25-52
    • /
    • 2007
  • This paper is focused on the economical efficiency of the geothermal heat pump system in school. As the importance of problems of environment and energy becomes larger, the development and distribution of energy-saving technology in the whole nation has become influential. This paper is intended, targeting on school buildings scattered all over the country, to evaluate the introduction and possibility of a terrestrial heat system which is in the first stage of introduction in the country, through energy consumption and efficiency in case where a terrestrial heat system is introduced. To do that, the author performed a qualitative analysis of the heat pump system using various terrestrial heat energy and the system introduced to existing school buildings and, through the analysis, made tentative evaluation on the most environment-friendly and energy saving type system. Also, the author performed simulation analysis using a currently typical school building standard and, on the basis of this result, conducted efficiency analysis of various heat pump systems. The conclusion according to synthetical analysis & evaluation can be summarized as follows. In case a heat pump system is introduced to a school building, it was deemed the investment in the early stage would increase, but the investment could be collected within 5~6 years through reduction of large operation expenses. Also, it was analyzed in case of terrestrial heat contracted heat mode using midnight electric power among heat pump systems, not only early investment but also operation expenses could be reduced to a great extent. Accordingly in case the system using terrestrial heat energy is applied to the school buildings that are to be newly built or repaired in the future, it will provide an object-lesson to students as well as contributing to energy saving.

  • PDF

다중 증발기를 갖는 에어컨시스템에 대한 최적화된 Multi-Fuzzy 제어기 설계 (Design of Optimized Multi-Fuzzy Controllers for Air-Conditioning System with Multi-Evaporators)

  • 정승현;최정내;오성권
    • 한국지능시스템학회논문지
    • /
    • 제17권1호
    • /
    • pp.7-12
    • /
    • 2007
  • 본 논문은 에어컨시스템의 효율과 안정도에 영향을 주는 과열도와 저압을 제어하기 위한 다중 퍼지제어기 설계를 소개한다. 시스템 에어컨은 압축기 응축기 및 여러 대의 증발기와 확장 밸브로 구성되며, 냉매의 상태가 달라지면 시스템 전반적으로 그 영향이 파급되어 제어가 쉽지 않다. 이에 3대의 확장밸브와 1대의 압축기에서 동시에 과열도와 저압을 효과적으로 제어하는 다중 퍼지제어기를 설계한다. 제안된 퍼지 제어기는 연속형 간략추론 방식과 이산형 lookup_table 방식을 사용하고, 실수코딩 유전자 알고리즘(GAs)을 이용하여 최적의 퍼지제어기의 환산계수를 구한다. 그리고 기존 방식의 결과와 연속형 간략추론 방식 및 이산형 lookup_table 방식의 시뮬레이션 결과를 성능관점에서 상호 비교한다.

이용자 평가를 통한 대학기숙사 내부공간의 거주환경개선에 관한 연구 -광주광역시내 종합대학 기숙사를 중심으로- (A Study on Improvement of Residential Environment for Indoor Space of University Dormitory through the Evaluation of User Satisfaction -the case of university dormitory in gwangju-)

  • 박행자;박성진;이청웅
    • 한국주거학회논문집
    • /
    • 제18권2호
    • /
    • pp.129-136
    • /
    • 2007
  • This study, as a case study of four university dormitories in Gwangju, examined the situation of interior space and conducted a quantitative survey investigating importance about the interior space and assessment factors of residential environment on users. Then user satisfaction at the assessment factors of residential environment was analyzed to draw problems and explore improvement. The results showed the following problems that should be resolved: Bedrooms should increase the area of convex space; toilets and bathrooms should be changed into a cluster type at least in common use by floor; rest space should reinforce heating and cooling system; robby space should become mixed space for various user's behavior; private fitness rooms should be planned as group fitness space; private libraries should reinforce lighting facilities; and computer rooms should complement and improve HVAC.