• Title/Summary/Keyword: HVAC type

Search Result 48, Processing Time 0.026 seconds

A Study on Design Decision of Qualitative Design Factors in Selecting of HVAC Type for Building (건축물의 공조방식 선택과정에 있어서 질적 설계요소들의 디자인 결정방법에 관한 연구)

  • 우세진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.762-769
    • /
    • 2004
  • Not only in building design but also in HVAC system design, it is important to ensure an objectivity in schematic design. In the study, the author suggested a method to make a logical decision for quality design factors a(footing the selection of HVAC type in initial design process, and to provide objective design values. Fuzzy theory, one of the theories describing in quantitative way the ambiguous-natured linguistic values, was used to determine the qualitative design factors of linguistic parameter nature. It was found that it has a potential as a method to determine a HVAC type satisfying the required values of qualitative design factors involved in selection of the system type. But this needs further studies to be settled in the selecting of HVAC type.

A Study on the Introduction of Fuzzy system into the Decision-Making process of HVAC designers

  • Woo, Se-Jin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.1
    • /
    • pp.12-17
    • /
    • 2004
  • This study is designed to grope for logical methods in the decision-making process of human beings such as creation and analysis. With this in mind, the paper worked with a process where the designers of a design team gather and analyze their opinions in a design process to decide on the HVAC system of buildings. The paper introduced the fuzzy theory, or one of the methods to quantitatively describe language values with ambiguous features, suggesting a method to determine the judgement and suggestion values of the HVAC designers with the characteristics of language variables as the values of design factors greatly influencing the HVAC system. As a result, the paper tested the possibility of the fuzzy system as a logical method to gather the judgement of HVAC designers in a stage of HVAC type selection exerting a great influence on the experience and judgement of the designers and having powerful linguistic features and to determine an appropriate HVAC type which can satisfy the suggested values of related design factors.

Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System (공조기가 설치된 고분 내에서의 열 및 음 환경 평가)

  • Park, Jin-Yang;Jun, Hee-Ho;Jun, Yong-Du;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.

Performance of an Duct-type HVAC System for Conservation of Ancient Tombs (고분보존용 덕트형 공조시스템의 운전 특성)

  • Jun, Yong-Du;Lee, Kum-Bae;Park, Jin-Yang;Ko, Seok-Bo;Jun, Hee-Ho;Youn, Young-Muk
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.29-34
    • /
    • 2006
  • Although the importance of good conservation of historic sites including ancient royal tombs is well aware, still not much attention has been paid for the facilities and systems to preserve those historic sites, which includes precious artifacts as wall paints and carved works, etc. Even the level of general understanding about the environment of the underground space of tombs is not satisfactory. In Korea, researchers have recently begun addressing the importance of maintaining proper environment for underground space as of ancient tombs and are making efforts to develop suitable HVAC(heating, ventilating and air-conditioning) systems for them. In this study, an HVAC system for a tomb ($D{\times}W{\times}H=1.3m{\times}3.0m{\times}1.2m$) was installed to maintain suitable indoor conditions for conservation of tomb. The temperature and humidity inside the tomb were measured to represent the performance of the installed duct-type HVAC system. Vibration levels due to the installed an HVAC system are alive investigated experimentally. According to the measured data, the level of vibration inside the present model tomb with the duct-type unit showed significantly lower values than the case with the indoor unit inside.

  • PDF

VAV Air Conditioning Research for Ship HVAC Efficiency (선박 HVAC 효율 증가를 위한 변풍량 방식 공기조화 연구)

  • Kang, Young-Min;Kim, Min-Wook;Jang, Jae-Hee;Kim, Hui-Mang;Oh, Jeon-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.93-95
    • /
    • 2016
  • In recent years, attention of ship owners for the energy saving of the vessel is being collected due to the volume decline. Ship accommodation consists of watertight type windows and is closed, Ship HVAC is used to promote a comfortable environment for the crew. In addition requirements for comfort of the crew is getting stronger with the improvement of living standards, there is a need for HVAC improvements. In this paper, propose method to save energy and improve HVAC controls by using the HVAC structure of the variable air volume.

  • PDF

Analysis of a Mount Type HVAC Control System Using Axiomatic Design (공리적 설계를 이용한 매립형 공기조화시스템의 분석)

  • Lee, Se-Jung;Hong, Eul-Pyo;Kim, Dae-Whan;Kim, Su-Ok;Park, Gyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1028-1033
    • /
    • 2008
  • The mount type HVAC control system is a type of an HVAC control system which is installed between a ceiling and ceiling boards of a room to control room temperature. Although the device is quite popular, design is conducted by a conventional way where engineering intuition and experiences are utilized. It is found that the design process is fairly inefficient and time-consuming because there are a lot of feedbacks. The axiomatic approach is used to investigate the design characteristics of the mount type HAVC control system and the Independence Axiom is utilized for the investigation. The Overall hierarchy is established up to the level of parts. It is found that the current design has many coupled and redundant aspects. The hierarchy is reorganized based on the Independence Axiom and a new design process is found. To exploit the new design process in practice, a design manual is made.

  • PDF

Evaluation of Noise Reduction Performance of HVAC System for Ships (선박용 HVAC 시스템의 소음저감성능 평가)

  • Kim, Sang-Ryul;kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Lee, Sung-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.497-503
    • /
    • 2010
  • In this paper, evaluation of noise reduction performance of HVAC system for ships by means of HVAC mock-up system is presented. Test is done for six different types of HVAC elements including room unit, silencer, etc. It is found that when diameter of silencer is small and air flow is large, flow noise degrades insertion loss. However, as diameter of silencer becomes larger, the effect of flow noise becomes smaller, and insertion loss up to 25 dB is measured. It is observed that insertion loss of diffuser type room unit is usually between zero and 10 dB, whereas that of the nozzle type room unit can be down to - 15 dB. In addition, it is shown that changing duct arrangement can reduce cabin noise by up to 2 dB, and providing same air flow to each room unit is crucial for generating less noise.

A Case Study on the Analysis of Characteristics of Marine HVAC Duct - For the Development of Maintenance Robot's Movement Algorithm - (선박 공조닥트의 특성분석에 관한 사례 연구 - 유지관리용 로봇의 이동 알고리즘 개발을 위한 분석 -)

  • Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.211-217
    • /
    • 2006
  • This study is focused on the analysis of the characteristics of marine HVAC duct. These results will be applied to develope a robot which is for maintaining a cabin comfort, convenience and healthy through HVAC duct. The followings are the results of this study. (1) The evaluated items which proposed by at the view point of robot's function can be adapted to other vessels for the same purpose, (2) For the case of round type duct. the maximized conditions which robot has to have are straight length of 40.152mm, inclination of $45^{\circ}$. horizontal bending of $90^{\circ}$. increasing diameter of 1.28 times, and 0.625 times decreasing diameter in branch. (3) For the case of rectangular type duct. the maximized conditions are straight length of 15.987mm. aspect ratio of 4.17:1, inclination of $18.92^{\circ}$. horizontal bending of $90^{\circ}$, and 0.65 times decreasing diameter in branch.

Numerical Study to Improve the Flow Uniformity of Blow-Down HVAC Duct System for a Train (전동차용 Blow-Down HVAC 덕트 시스템의 유동 균일도 향상을 위한 수치적 연구)

  • Kim, Joon-Hyung;Rho, Joo-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.18-23
    • /
    • 2016
  • A HVAC(Heating Ventilation and Air Conditioning) is adapted to increase the comfort of the cabin environment for train. The train HVAC duct system has very long duct and many outlets due to the shape of a train set. the duct cross section shape is limited by a roof structure and equipments. Therefore, the pressure distribution and flow uniformity is an important performance indicator for the duct system. In this study, the existing blow down type HVAC duct system for a train was supplemented to improve the flow uniformity by applying a design method combining design of experiment (DOE) with numerical analysis. The design variables and the test sets were selected and the performance for each test set was evaluated using CFD(Computational Fluid Dynamics). The influence of each design variable on the system performance was analysed based on the results of the performance evaluation on the test sets. Furthermore, the optimized model, whose the flow uniformity was improved was produced using the direct optimization(gradient-based method). Finally, the performance of the optimized model was evaluated using numerical analysis, and it was confirmed that its flow uniformity has indeed improved.

An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage (지하도상가의 HVAC 구성방식에 따른 운전특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF