• Title/Summary/Keyword: HVAC duct

Search Result 48, Processing Time 0.029 seconds

Active Control of Noise in HVAC Ducts Using Fuzzy LMS Algorithms (퍼지 LMS 알고리즘을 이용한 공조덕트에서의 능동소음제어)

  • 남현도;안동준;박용식
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.265-272
    • /
    • 1999
  • A LMS algorithms has been widely used for an adaptive filter algorithm in active noise control systems. But this algorithm has poor convergence and it is very difficult to select optimal convergence parameters in this algorithm. In this paper, a fuzzy LMS algorithm where the convergence parameters are computed using a fuzzy logic controller was proposed. A proposed algorithm was applied to active noise control system in HVAC(central Heating Ventilation and Air Conditioning) ducts. The experimental ducts and experimental apparatus were designed and manufactured for experiments, and the modelling of the experimental ducts was also performed for computer simulations. Computer simulations and experiments were performed to show the effectiveness of a proposed algorithm.

  • PDF

Development of a Duct Cleaning Robot and Technology Trends for Subway Stations (지하역사 덕트 청소로봇 기술동향 및 개발)

  • Jeong, Woo-Tae;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1335-1341
    • /
    • 2011
  • Conserving clean air and removing contaminants and particular matters accumulated in the ventilation system of the subway stations are key issue for green railway environment. There is no national guideline or industrial regulations to sustain clean duct and ventilation system, which requires rapid reformation of cleaning procedure and system. In fact, accumulated various particular matters and dusts can occur secondary air contamination and become a primary health harm factor for subway passengers. This study investigates various duct cleaning technologies and trends. In additon, effective cleaning method with an automated robot device is proposed. In particular, current dust cleaning technologies and duct cleaning robots are analyzed based on their functions and feasibilities. The proposed design of automated device is expected to save the operating cost of subway HVAC system and sustain clean air environment.

  • PDF

Computational Analysis on the Noise Characteristics of Ship Large Duct (선박용 대형 덕트의 소음 특성 전산해석 연구)

  • Song, Jee-Hun;Hong, Suk-Yoon;Lee, Yi-Soo;Kwon, Hyun-Wung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.751-758
    • /
    • 2015
  • Noise prediction for HVAC(Heating, Ventilating and Air Conditioning) systems are normally performed by empirical method suggested by NEBB(National Environmental Balancing Bureau, 1994). However, the method is not suitable for large ducts in ships. In this paper, computational analysis methods are used to develop a noise prediction method for the large ducts in ships. To develop regression formula of attenuation of sound pressure level in large ducts, Boundary Element Method(BEM) is used. BEM and Computational Fluid Dynamics(CFD) are applied to the analysis of flow-induced noise in ducts with stiffeners inside. Loud noise above 100 dB can be generated in some cases. Breakout noises of large ducts are also analyzed by using BEM and Finite Element Method(FEM). The acoustic pressure level shows about 10-15dB difference between inside and outside of the duct. Utilizing the results of this study, it is expected that shipyard planners can predict noise of the HVAC system for ships.

Adaptive Active Noise Control in a Duct Using Improved SLMS Algorithms (개선된 SLMS 알고리즘을 이용한 덕트 내에서의 능동소음제어)

  • Seo, Sung-Dae;Nam, Ju-Hyung;Ahn, Dong-Jun;Nam, Hyun-Do
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.433-434
    • /
    • 2007
  • In this paper, active control of noise in a HVAC duct is considered. Most adaptive control filters have used FIR structures based on filtered-x LMS algorithms. But, the IIR structures are more desirable for the active control of duct noise in order to remove the poles introduced by the acoustic feedback and presented an algorithm to adjust the coefficients of an IIR filter using the recursive least mean square (RLMS) algorithm. A smoothed LMS algorithm is proposed to improve a convergent speed of filter parameters when the noise is wide band and power of input is time varying. And computer simulations have performed to show the effectiveness of the proposed algorithm.

  • PDF

Coherent Analysis of vehicle HVAC Using the MDSA Method (다차원 해석법을 이용한 자동차 공조시스템의 기여도분석)

  • Oh Jae-Eung;Hwang DongKun;Abu Aminudin;Lee Jung-Youn;Kim SungSoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.143-150
    • /
    • 2005
  • To verify applicability of multi-dimensional spectral analysis (MDSA) fur noise source identification two different approaches which are frequency response and coherent function have been investigated. The coherence function approach appears able to separate the correlated system when the noise sources were coherent. In this study, we identify contribution of structure-borne-noise of vehicle HVAC system using MDSA method. Firstly, to identify the applicability of MDSA method, 4-inputs of vehicle HVAC system were the signals measured by accelerometers attached on the selected noise sources which were composed of blower, evaporator, heater and duct. While 1-output which was driver's position sound was the SPL signals measured by a remote microphone, when the blower motor was operating. We identify efficiency of systems modeled with four Inputs/single output through ordinary coherence function (OCF) and partial coherence function (PCF). As a result of experiment, the blower accounted for $62-88\%$ of the overall level of sound energy density. Also, according to the analysis of acoustic signal and vibration signals measurement, an investigation of the noise source identification in the vehicle HVAC is presented. With the sound intensity method, the major sources of the vehicle HVAC radiation are verified. Also the method of improving the noise reduction is proposed by attaching damping patch access to blower motor and noise reduction is verified.

Effect of a Variation of a Main Duct Area on Flow Distribution of Each Branch (주덕트의 단면적 변화가 분지덕트의 유량분배에 미치는 영향)

  • Lee Jai-Ho;Kim Beom-Jun;Cho Dae-Jin;Yoon Suck-Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.386-395
    • /
    • 2005
  • With the development of a living standard, the importance of indoor air conditioning system in all kinds of buildings and vehicles has increased. A lot of researches on energy losses in a duct and various kinds of flow pattern in branches or junctions have been carried out over many years, because the primary object of a duct system used in HVAC is to provide equal flow rate in the interior of each room by minimizing pressure drop. In this study, to get equal flow distribution in each branch, a blockage is applied to the rectangular duct system. The flow analysis for flow distribution of a rectangular duct with two branches was performed by CFD. By using SIMPLE algorithm and finite volume method, flow analysis is performed in the case of 3-D, incompressible, turbulent flow. Also, the standard $k-{\varepsilon}$ model and wall function method were used for analysis of turbulent fluid flow. The distribution diagrams of static pressure, velocity vector, turbulent energy and kinetic energy in accordance with variation of Reynolds number and blockages location in a rectangular duct show that flow distribution at duct outlets is improved by a blockage. In this rectangular duct system, mean velocity and flow rate distribution in two branch outlets are nearly constant regardless of variation of Reynolds number, and a flow pattern of the internal duct has a same tendency as well.

PIV Measurement of Flow Inside of HVAC Blower Unit (자동차 HVAC용 Blower Unit 내부 유동장의 PIV 계측)

  • Ji, Ho-Seong;Kim, Bo-Ram;Lee, Sang-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.165-173
    • /
    • 2007
  • Flow characteristics inside a blower unit of an automotive HVAC module were investigated experimentally using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser, a high-resolution CCD camera, optics and a synchronizer. The prototype siroco-fan with forward-curved blades was operated under the same condition of real car. The scroll casing was made transparently for capturing clear flow images. The time-averaged velocity fields were measured in three cross sections. Flow is accelerated with going toward the outer wall of scroll due to centrifugal force and large pressure gradient formed in the region between the fan and the outer casing wall. The presence of the cut-off region and diffusing duct of fan outlet influences largely the flow structure inside the blower unit.

A Study on the Refractory Performance Verification of the Thermal Insulators for AES Ducts and Piping (AES 계열 덕트·배관 단열재의 내화성능 검증에 관한 연구)

  • Kwang-Ho Ham;Jea-Chun Sa;Joo-Hwan Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.419-429
    • /
    • 2024
  • Purpose: To enhance the non-combustibility of fire protection piping insulation and improve the heat resistance of smoke extraction duct insulation, I plan to verify the suitability of AES insulation materials for these applications through performance testing. Method: The non-combustibility, heat resistance, and thermal insulation performance of AES insulation materials will be verified through various tests. Result: According to the 'Standards for Flame Retardancy and Fire Spread Prevention of Building Finishing Materials,' the results of non-combustibility and gas toxicity tests confirmed the non-combustible properties. The standard fire resistance tests verified the fire resistance performance. Additionally, the thermal insulation performance was confirmed through building insulation tests. Conclusion: As the performance tests on AES inorganic insulation materials have proven their noncombustibility, fire resistance, and thermal insulation performance, these materials are considered a viable alternative for improving fire spread prevention in buildings.

Development of Thermal Mass Flow Meter (열전달 질량유량계 개발)

  • Chi, Daesung
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF

A Numerical Analysis of the Pressure Drop according to the Shape of TiO2 Photocatalyst-coated Module in a HVAC Duct (HVAC 덕트 내에 설치된 광촉매코팅 모듈의 형상이 압력강하에 미치는 영향)

  • Hwang, Kwang-Il;Koo, Jae-Hyoek;Kim, Da-Hye;Lee, Hyun-In;Choi, Young-Guk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1055-1062
    • /
    • 2011
  • The purpose of this study is to develop the shape of photocatalyst-coated module for improve the IAQ, which is installed at inside of ductwork and detachable. Including 3 column types(square, circle, diamond) and 2 fin types(diamond and square), totally 5 types are previously declared for numerical analysis and comparison, 5 types are. As the results of numerical analysis, almost the velocity varied at the range of ${\pm}0.3m$ from the module, except the Type A-3(diamond column type) which is affected to ${\pm}0.4m$ range and shows the biggest velocity differences. Among the 5 types, the diamond fin type(Type B-1) is analyzed as the most stable in velocity. And the results of local pressure drop show that the difference of pressure coefficient of Type B-1 is computed as 0.59, and that of Type A-3 is 2.44. Meanwhile, from the effect analysis of the number of module, the flow conflict happens and the pressure difference between before and after the module increases if there are over 3 modules inserted.