• 제목/요약/키워드: HVAC 시스템평가

검색결과 45건 처리시간 0.018초

플러스에너지하우스 설계 및 에너지 성능 평가 (Design and Energy Performance Evaluation of Plus Energy House)

  • 김민휘;임희원;신우철;김효중;김현기;김종규
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.55-66
    • /
    • 2018
  • South Korea aims to shift the 20 percent of electricity supplement from the fossil fuel including the nuclear to renewable energy systems by 2030. In order to realize this agenda in the buildings, the plus energy house is necessary to increase the renewable energy supplement beyond the zero energy house. This paper suggested KePSH (KIER Energy-Plus Solar House) and energy performance of house and renewable energy systems was investigated. The KePSH has the target of generating 40% surplus energy than the conventional house energy consumption. The plus energy house is the house that generates surplus energy from the renewable energy sources than that consumes. In order to minimize the cooling and heating load of the house, the shape design and passive parameters design were conducted. Based on the experimental data of the plug load in the typical house, the total energy consumption of the house was estimated. This paper also suggested renewable energy sources integrated HVAC system using air-source heat pump system. Two cases of renewable energy system integration methods were suggested, and energy performance of the cases was investigated using TRNSYS 17 program. The results showed that the BIPV (building integrated photovoltaic) system (i.e., CASE 1) and BIPV and BIST system (i.e., CASE 2) shows 42% and 29% of plus energy rate, respectivey. Also, CASE 1 can generate 59% more surplus energy compared with the CASE 2 under the same installation area.

차량 내부 탑승자의 쾌적성 평가를 위한 초기 냉방운전 성능에 대한 수치해석적 연구 (Numerical Analysis on the Initial Cool-down Performance Inside an Automobile for the Evaluation of Passenger's Thermal Comfort)

  • 김윤기;양장식;백제현;김경천;지호성
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.115-123
    • /
    • 2010
  • Cool-down performance after soaking is important because it affects passenger's thermal comfort. The cooling capacity of HVAC system determines initial cool down performance in most cases, the performance is also affected by location, and shape of panel vent, indoor seat arrangement. Therefore, optimal indoor designs are required in developing a new car. In this paper, initial cool down performance is predicted by CFD(computational fluid dynamics) analysis. Experimental time-averaging temperature data are used as inlet boundary condition. For more reliable analysis, real vehicle model and human FE model are used in grid generation procedure. Thermal and aerodynamic characteristics on re-circulation cool vent mode are investigated using CFX 12.0. Thermal comfort represented by PMV(predicted mean vote) is evaluated using acquired numerical data. Temperature and velocity fields show that flow in passenger's compartment after soaking is considerably unstable at the view point of thermodynamics. Volume-averaged temperature is decreased exponentially during overall cool down process. However, temperature monitored at different 16 spots in CFX-Solver shows local variation in head, chest, knee, foot. The cooling speed at the head and chest nearby panel vent are relatively faster than at the knee and foot. Horizontal temperature contour shows asymmetric distribution because of the location of exhaust vent. By evaluating the passenger's thermal comfort, slowest cooling region is found at the driver's seat.

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

EnergyPlus를 이용한 건물 부위별 목질제품 적용에 따른 건축물 에너지 절감 기여도 평가 (Evaluation and Analysis of The Building Energy Saving Performance by Component of Wood Products Using EnergyPlus)

  • 서정기;위승환;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권5호
    • /
    • pp.655-663
    • /
    • 2016
  • 최근, 전 세계적으로 온실 가스 증가에 따른 기후 변화에 대한 문제가 논의되고 있다. 그중, 건축물에서의 에너지 소비량은 전체 에너지 소비량의 40%까지 증가할 것으로 예상된다. 따라서 건축물에서의 에너지 소비량 절감에 대한 노력이 필요한 실정이다. 본 연구에서는, 건물에너지 절감에 효과적으로 기여하는 재료 중 하나인 목재를 이용하여, 목질 제품 구성에 따른 중부지방과 남부지방의 난방에너지 요구량에 대하여 시뮬레이션을 통해 분석하였다. 시뮬레이션 도구는 미국 에너지부(Department of Energy)가 BLAST와 DOE-2의 장점을 결합해 만든 동적 에너지 해석 엔진인 EnergyPlus를 이용하였다. EnergyPlus는 다양한 건물 및 HVAC 시스템 구성요소(Object)에 대한 입력항목(Field)을 가지고 있으며, 특히 건물, 공조시스템, 열원기기 사이의 피드백을 통해 통합된 동시계산을 수행하며, ASHRAE Standard 140-2007 표준에 따라 상용 프로그램 간의 비교를 통해 검증된 프로그램이다. 시뮬레이션을 위한 기상데이터는 EnergyPlus에서 제공하는 IWEC 인천 지역과 광주 지역의 epw 형식 기상데이터를 이용하였다. 대상 모델은 한국농어촌공사에서 제시한 2012년 농 어촌주택 표준설계도면 중 '농림-12-26-가' 유형을 이용하였으며 총 10개의 실로 구성되어 있다. 시뮬레이션 분석 결과, 중부지방과 남부지방 별 목질 제품의 적용 범위를 실내마감재, 실외마감재, 창호, 목구조로 단계적으로 변경해 지역에 따라 각각 16 Case의 시뮬레이션을 수행한 결과 실내외의 마감재로 목재를 사용한 것만으로도 에너지 성능이 향상된 것을 확인할 수 있었다.

통합 채광시스템의 건물 냉난방 에너지 성능평가 (Building Energy Savings due to Incorporated Daylight-Glazing Systems)

  • 김정태;안현태;김곤
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.1-8
    • /
    • 2005
  • 건물 내에 존재하는 자연광은 조명원으로 국한되지 않고 시각적, 심리적 자극을 통한 실내 환경의 질적 향상에 이르기까지 에너지절약 및 공간의 쾌적성에 큰 영향을 미친다. 유입되는 자연광량에 비례적으로 연동되는 건물에너지는 전기조명에너지를 절감시키고 난방 기간동안 일사열의 유입에 따른 난방에너지를 절감시킨다. 여름철에는 전기조명의 소등으로 인한 조명원의 발열량이 감소됨으로써 냉방부하의 감소에 이르기까지 포괄적인 영향을 미친다. 조명개발분야의 선진국에서는 에너지 절약형 광원의 대체와 아울러 자연채광과 통합된 최적 조명제어 기술의 운용만이 건물이 가지고 있는 에너지 절약의 잠재력을 현실화시킬 수 있다고 판단하고 있다. 따라서 본 연구는 일반적인 사무소 모델 공간의 에너지 절약형 인공조명을 대상으로 자연광 유입에 따른 연동적 조명제어 기법을 적용하는 경우를 대상으로, 인공조명의 소등량에 따른 조명에너지의 절감량과 이에 수반되는 냉방에너지의 점감량 및 일사열 취즉에 따른 겨울철 난방 부하 절감량을 분석함으로써 자연채광의 건물에너지에 대한 연간 기여도를 통합 분석하였다. 특히 자연채광의 성능은 실험을 통한 측정 데이터를 이용하고 에너지 해석 프로그램을 재구성하여 실질적인 절감량을 도출하도록 시도하였다.