• Title/Summary/Keyword: HVAC (Heating

Search Result 186, Processing Time 0.03 seconds

The Measurement of the Indoor Air Quality in Subway (전동차의 실내 공기청정도 측정 평가)

  • So, Jin-Sub;Yoo, Seong-Yeon;Yun, Cha-Jung;Kim, Wan-Jong;Kang, Sung-Hae;Park, Duk-Sin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1325-1329
    • /
    • 2007
  • Indoor air quality is an important determinant of human health and comfort. However, the complexity of pollution sources and the multitude of parties responsible for creating indoor exposures makes the improvement of air quality difficult. The HVAC(Heating, Ventilating and Air-Conditioning) system is important facility to provide comfortable environment passenger service. The Ministry of Environment is established "Indoor Air Quality Management guidelines in Public Facilities"in December 2006. Hereupon, the train and the subway are included. In this research air quality in the Subway compartment has been measured. As a result, the concentrations of PM10 and $CO_2$ were reached to 93% and 61% of the regulation values, respectively. Thus, the indoor air qualities of subway have been proved that they satisfy the recommended guidelines by the Ministry of Environment.

  • PDF

The development of Air-cleaner with Roll Filter inside railroad passenger car (롤필터를 장착한 객차용공기청정장치 개발)

  • Lee, Young-Seop;NamGoong, Seok
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1297-1301
    • /
    • 2007
  • The indoor air quality guideline of public transportation means was prepared recently. therefore we consider a countermeasure for the indoor air quality improvement of public transportation means. In this work, air-cleaner with roll filter system which developed alternative of indoor air quality guideline. The develpoed roll filter system is two function. the first function harmoniously circulated to heating and cooling air through HVAC system and secondary function removed PM(particluatie matters) which re-scatting to passenger's movement and suppled from outdoor air. Filter media of roll filter system select optimum electret mesh filter out of many filter media. Selected filter media was performanced tests of pressure drop, collection efficiency and dust holding capacity. Finally developed roll filter system was performanced bench test.

  • PDF

A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX (CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.

Design and Preparation of High-Performance Bulk Thermoelectric Materials with Defect Structures

  • Lee, Kyu Hyoung;Kim, Sung Wng
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.2
    • /
    • pp.75-85
    • /
    • 2017
  • Thermoelectric is a key technology for energy harvesting and solid-state cooling by direct thermal-to-electric energy conversion (or vice versa); however, the relatively low efficiency has limited thermoelectric systems to niche applications such as space power generation and small-scale or high-density cooling. To expand into larger scale power generation and cooling applications such as ATEG (automotive thermoelectric generators) and HVAC (heating, ventilation, and air conditioning), high-performance bulk thermoelectric materials and their low-cost processing are essential prerequisites. Recently, the performance of commercial thermoelectric materials including $Bi_2Te_3$-, PbTe-, skutterudite-, and half-Heusler-based compounds has been significantly improved through non-equilibrium processing technologies for defect engineering. This review summarizes material design approaches for the formation of multi-dimensional and multi-scale defect structures that can be used to manipulate both the electronic and thermal transport properties, and our recent progress in the synthesis of conventional thermoelectric materials with defect structures is described.

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

A Case Study on the Design for Jeong-eup Second Safety Evaluation Tentative Research Institute (안전성평가연구소 정읍제2안전성평가시험연구동 설계사례)

  • Jung, Jong-Lim;Oh, Kun-Hyoan;Jung, Jae-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.552-557
    • /
    • 2008
  • This paper introduces to schematic design for Korea Institute of Toxicology Second Campus at Jeong-eup and provides fundamental information and data in order to design this laboratory facility to meet the criteria of G.L.P(Good Laboratory Practice), AAALAC(Association for Assessment and Accreditation of Laboratory Animal Care) and so on. This paper especially focus on design criteria, HVAC(Heating Ventilating and Air Conditioning) equipment and systems, plumbing equipment and systems, maintenance of equipment and systems and energy saving system of this laboratory facility.

  • PDF

Temperature and Humidity Monitoring Using Ubiquitous Senor Network in Railway Cabin (철도차량 객실 온습도 USN 모니터링 기술)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.948-951
    • /
    • 2008
  • Ubiquitous sensor network (USN) based on ZigBee communication protocol has been used in various application fields, such as home-network, intelligent building and machine, logistics, environmental monitoring, military field, security field and etc. The ZigBee is targeted at radio-frequency application that require a low data rate, long battery life and secure network. Especially, the USN system can be applied efficiently to building-indoor where the complex geometry is adopted. In this study, all 90 points of railway cabin indoor were monitored for temperature and humidity using USN technology. All sensors were pre/post-calibrated and the temperature/humidity change were analyzed in a railway cabin in real-time. The results would be useful to develop the cabin heating, ventilating and air conditing (HVAC) system to meet all passengers' thermal comfort regardless of their seat position.

  • PDF

A Study on Improvement of Residential Environment for Indoor Space of University Dormitory through the Evaluation of User Satisfaction -the case of university dormitory in gwangju- (이용자 평가를 통한 대학기숙사 내부공간의 거주환경개선에 관한 연구 -광주광역시내 종합대학 기숙사를 중심으로-)

  • Park, Hang-Ja;Park, Sung-Jin;Lee, Cheong-Woong
    • Journal of the Korean housing association
    • /
    • v.18 no.2
    • /
    • pp.129-136
    • /
    • 2007
  • This study, as a case study of four university dormitories in Gwangju, examined the situation of interior space and conducted a quantitative survey investigating importance about the interior space and assessment factors of residential environment on users. Then user satisfaction at the assessment factors of residential environment was analyzed to draw problems and explore improvement. The results showed the following problems that should be resolved: Bedrooms should increase the area of convex space; toilets and bathrooms should be changed into a cluster type at least in common use by floor; rest space should reinforce heating and cooling system; robby space should become mixed space for various user's behavior; private fitness rooms should be planned as group fitness space; private libraries should reinforce lighting facilities; and computer rooms should complement and improve HVAC.

The Measurement of the Indoor Air Quality in KTX Train (KTX 객실내 공기청정도 측정)

  • So, Jin-Sub;Lee, Sung-Uk;Park, Duck-Shin;Yoo, Seong-Yeon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1210-1213
    • /
    • 2006
  • Indoor air quality is an important determinant of human health and comfort. However, the complexity of pollution sources and the multitude of parties responsible for creating indoor exposures makes the improvement of air quality difficult. The KTX HVAC(Heating, Ventilating and Air-Conditioning) system is important facility to provide comfortable environment passenger service. The Ministry of Environment is planning to enforce$\square\square$Indoor Air Quality Management law in Public Facilities$\square\square$in year 2008. Hereupon, the train and the subway are included. In this research air quality in the KTX Train compartment has measured. As a result, The average amounts of PM10(particulate matters), $CO_2$(carbon dioxide)measured $20{\mu}g/m^3$, 1,097ppm in KTX respectively. There are compare to regulation the value is 10% for PM10 and 43% for $CO_2$. Thus, the indoor air quality of KTX train have been proved satisfy the recommendation the Ministry of Environment guidelines.

  • PDF

Study of Effects of Body Leakage on Performance of a Sunroof (차체 기밀특성이 선루프 성능에 미치는 영향 연구)

  • 이영림
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.201-209
    • /
    • 2001
  • Some passenger cars with sunroofs open at tilted positions experience reverse flows into cabin rooms and wind noises much louder compared to other cars. In this study, flows around open sunroofs are numerically studied with the variations of body leakage. The effects of body leakage on ventilation and wind noise of a sun roof are examined, in particular. Furthermore, flow visualization, pressure, and noise measured from wind tunnel and road tests are presented. The results show that too small body leakage results in poor performance of ventilation and generates high wind noise around a sunroof. It is therefore very important to secure an adequate body leakage from the early design stage to achieve better performance of a sunroof as well as passengers' comfort related to HVAC(Heating, Ventilation, and Airconditioning).

  • PDF