• Title/Summary/Keyword: HV%

Search Result 1,031, Processing Time 0.028 seconds

Structure and Function of the phnF Gene of Pseudomonas sp. Strain DJ77 (Pseudomonas sp. Strain DJ77에서 phnF 유전자의 구조)

  • 이성훈;김성재;신명수;김치경;임재윤;이기성;민경희;김영창
    • Korean Journal of Microbiology
    • /
    • v.33 no.2
    • /
    • pp.92-96
    • /
    • 1997
  • The 6.8 kb Xhol fragment of chromosomal ONA of Pseudomonas sp. 0177 contains the phnDEFG genes involved in the degradation of polyaromatic hydrocarbons and chlorinated aromatics. Here, we report the nucleotide sequence of the ORF encoding a polypeptide consisted of 143 amino acids with a Mr of 13,859. The nucleotide sequence of the ORF is 99% and 68.6% identical to the downstream region of catE of Sphingomonas sp. strain HV3 and the ORF between xylE and xylG of Sphingomonas yanoikuyae Bl, respectively. The deduced amino acid sequence of the PhnF has 62.3% identity with the amino acid encoded hy orfY region of Citrobacter freundii DSM30040. We now confirm that the ORF is located between the catechol 2,3-dioxygenase (C230), phnE, and 2-hydroxymuconic semialdehyde dehydrogenase (2HMSO), phnG.

  • PDF

Design of a Cell Verification Module for Large-density EEPROM Memories (대용량 EEPROM 메모리 셀 검증용 모듈 회로 설계)

  • Park, Heon;Jin, RiJun;Ha, Pan-Bong;Kim, Young-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.2
    • /
    • pp.176-183
    • /
    • 2017
  • There is a problem of long erase and program times in testing large-density memories. Also, there is a need of testing the VT voltages of EEPROM cells at each step during the reliability test. In this paper, a cell verification module is designed for a 512kb EEPROM and a CG (control gate) driver is proposed for measuring the VT voltages of a split gate EEPROM having negative erase VT voltages. In the proposed cell verification module, asymmetric isolated HV (high-voltage) NMOS devices are used to apply negative voltages of -3V to 0V in measuring erase VT voltages. Since erasing and programming can be done in units of even pages, odd pages, or a chip in the test time reduction mode, test time can be reduced to 2ms in testing the chip from 4ms in testing the even and the odd pages.

Plasma nitriding on chromium electrodeposit

  • Wang Liang;K.S. Nam;Kim, D.;Kim, M.;S.C. Kwon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.29-30
    • /
    • 2001
  • This paper presents some results of plasma nitriding on hard chromium deposit. The substrates were C45 steel and $30~50{\;}\mu\textrm{m}$ of chromium deposit by electroplating was formed. Plasma nitriding was carried out in a plasma nitriding system with $95NH_3{\;}+{\;}SCH_4$ atmosphere at the pressure about 600 Pa and different temperature from $450^{\circ}C{\;}to{\;}720^{\circ}C$ for various time. Optical microscopy and X-ray diffraction were used to evaluate the characteristics of surface nitride layer formed by nitrogen diffusion from plasma atmosphere inward iCr coating and interface carbide layer formed by carbon diffusion from substrate outward Cr coating. The microhardness was measured using microhareness tester at the load of 100 gf. Corrosion resistance was evaluated using the potentiodynamic measurement in 3.5% NaG solution. A saturated calomel electrode (SiCE) was used as the reference electrode. Fig.1 shows the typical microstructures of top surface and cross-section for nitrided and unnitrided samples. Aaer plasma nitriding a sandwich structure was formed consisting of surface nitride layer, center chromium layer and interface carbide layer. The thickness of nitride and carbide layers was increased with the increase of processing temperature and time. Hardness reached about 1000Hv after nitriding while 900Hv for unnitrided hard chromium deposit. X-ray diffraction indicated that surface nitrided layer was a mixture of $Cr_2N$ and CrN at low temperature and erN at high temperature (Fig.2). Anodic polarization curves showed that plasma nitriding can greatly improve the corrosion resistance of chromium e1ectrodeposit. After plasma nitriding, the corrosion potential moved to noble direction and passive current density was lower by 1 to 4 orders of magnitude compared with chromium deposit(Fig.3).

  • PDF

Surface Properties, Friction, Wear Behaviors of the HOVF Coating of T800 Powder and Tensile Bond Strength of the Coating on Ti64

  • Cho, T.Y.;Yoon, J.H.;Joo, Y.K.;Cho, J.Y.;Zhang, S.H.;Kang, J.H.;Chun, H.G.;Kwon, S.C.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.11-12
    • /
    • 2008
  • Micron-sized Co-alloy T800 powder was coated on Inconel718 (IN718) using high velocity oxygen fuel (HVOF) thermal spraying by the optimal coating process (OCP) determined from the best surface hardness of 16 coatings prepared by Taguchi program. The surface hardness improved 140-160 % from 399 Hv of IN718 to 560-630 Hv by the coating. Porosity of the coating was 1.0-2.7 %, strongly depending on spray parameters. Both friction coefficients (FC) and wear traces (WT) of the coating were smaller than those of IN718 substrate at both $25^{\circ}C$ and $538^{\circ}C$. FC and WT of IN718 and coating decreased with increasing the surface temperature. Tensile bond strength (TBS) and fracture location (FL) of Ti64/T800 were 8,770 psi and near middle of T800 coating respectively. TBS and FL of Ti64/NiCr/T800 were 8,740 psi and near middle of T800 coating respectively. This showed that cohesion of T800 coating was 8,740-8,770 psi, and adhesion of T800 on Ti64 and NiCr was stronger than the cohesion of T800.

  • PDF

The Removal Study of Restoration Materials for the Ceramics (토기의 복원재료로 사용되는 합성수지 제거 연구)

  • Kim, Hyoyun;Park, Daewoo;Nam, Byeongjik;Jang, Sungyoon
    • 보존과학연구
    • /
    • s.32
    • /
    • pp.61-74
    • /
    • 2011
  • This study examines the removal effects of solvents which were applied on three adhesives and three filling materials for ceramics. The chosen materials are Cemedine C, Loctite$^{(R)}$ 401$^{TM}$, Araldite Rapid Type, plaster of paris, CDKI 520A+B, Araldit$^{(R)}$ SV427-2+HV427-1. For the first examination, each different materials were soaked into different solvents, and then the soften level were compared by compressive pressure. The result of the first exam showed that Cemedine C was dissolved easily in acetone. Furthermore Araldite, CDK and SV427 were soften efficiently by Dichloromethan, Tetrahydrofuran and DMX(Dichloromethan+Methanol+Xylene). However, Loctite and plaster were not able to make sample for the first test. Therefore, the second test carried on only. The second examination, chosen effective solvents from the first test were applied with two different methods; soaking and saturated atmosphere. Almost every sample could removed by soaking method in ten minutes, and saturated atmosphere method needs 24 hours for the safety.

  • PDF

An Experimental Study on Drilling Conditions for the Instrumentation of Nuclear Fuel (핵연료 계장을 위한 천공조건에 대한 실험적 연구)

  • Hong, Jintae;Kim, Ka-Hye;Jeong, Hwang-Young;Ahn, Sung-Ho;Joung, Chang-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.1
    • /
    • pp.113-119
    • /
    • 2013
  • To develop a new nuclear fuel, it needs to make a test fuel rod and carry out burn-up test in the test loop of a research reactor to check the irradiation characteristics of the nuclear fuel. At that time, several sensors such as thermocouples, LVDTs and SPNDs are needed to be attached in and out of the fuel rod and connect them with instrumentation cables. Then, the instrumentation cables deliver the signals measured by the sensors to the measuring device located outside of the reactor pool. In particular, to install a thermocouple in a fuel rod, it needs to drill off holes on the alumina blocks and sintered $UO_2$ pellets. However, because the hardness of a sintered $UO_2$ pellet is 700 Hv (or HRC 61) and that of an alumina block is 1480 Hv, a special drilling machine which adapts a diamond coated drill bit had developed. In this study, several case experiments have been carried out to find an optimal drilling condition of the drilling machine. And, using the optimal drilling condition, minimum numbers of the holes that a drill bit can drill off are verified.

나노질화 처리를 통한 사출금형 특성 연구

  • Sin, Hong-Cheol;Lee, Gyeong-Hwang;Kim, Dae-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.105-105
    • /
    • 2010
  • 자동차 차체부품에 적용되는 플라스틱 소재는 강도와 내마모성, 내충격성의 충분한 물성확보가 필요하며, 이에 플라스틱 소재의 기계적 특성 향상을 위해 유리 섬유가 다량 함유된 복합소재적용이 증가하고 있다. 반면 플라스틱이 고강도화함에 따라 제품 성형을 위한 사출 금형을 손상시키는 사례가 빈번하게 발생하고, 소재의 유동성 저하에 따른 사출 불량이 증가하고 있어 고강성 플라스틱 복합소재에 대응하는 고경도, 고내마모 특성이 부여된 사출 금형의 개발이 시급한 실정이다. 특히 사출 금형에 사용되는 소재는 기존 소재에 비해 우수한 내마모성과 함께 고광택을 유지하는 것이 더욱 중요해졌으며, 이에 따라 유럽, 일본과 국내 연구진에 의해 다양한 연구가 진행되고 있다. 그 중에서도 일본에서 개발되어 국내에도 소개된 래디칼 질화는 기존 질화법에 표면의 화합물 층만을 제어하는 것으로 다소의 표면 광택 효과는 있으나, 플라스틱 사출에 그대로 적용하기에는 무리가 따르므로 그 용도가 극히 제한적이다. 본 연구에서 적용한 나노 질화기술은 0.1torr 이하의 고진공에서 고밀도의 플라즈마 에너지를 발생시키는 방법으로 화합물층이 없는 나노 크기의 질화층을 소재 표면에 형성시키는 기술로서, 처리 후에도 표면의 색상 및 광택의 변화가 없는 것을 특징으로 한다. 또한 표면 경도 및 피로 특성을 향상시킴으로써 금형의 내구 수명을 향상시킬 것으로 기대된다. 본 연구에서는 KP4 금형 소재를 사용하여 플라즈마 이온 질화 시험 조건에 따른 소재의 경도 및 내마모 특성을 파악하고, 미세 조직 분석 및 XRD 분석 등을 통해 내마모 특성 향상에 대한 기본 특성을 평가하였다. 또한 인장시험을 통해 인장강도, 항복강도 및 연신율을 파악하고, 이를 토대로 고주기 피로시험을 실시함으로써 S-N curve를 얻고, 이를 통해 피로 강도 및 피로 수명에 미치는 나노 질화 처리의 영향을 파악하고자 하였다. 플라즈마 이온 질화 시험은 질소와 수소 비율($N_2:H_2$), 진공도, Screen bias voltage, Bias voltage를 변화시켰으며, 챔버 온도는 $400^{\circ}C$로 고정하였으며, 처리시간도 3시간으로 고정하였다. 질소와 수소의 비율은 3:1일 때 최고의 내마모 특성을 보였으며, 진공도는 내마모 특성에 큰 영향을 미치지 않는 것으로 관찰되었다. KP4의 초기 경도값은 약 302 Hv인 반면 최적의 나노 질화처리를 거친 시편에서는 800Hv 이상의 Vickers 경도값을 보였다. SEM 미세조직 분석과 EPMA를 통한 성분 분석을 시행한 결과 표층으로부터 약 $1.5{\mu}m$의 나노질화층을 확인할 수 있었다.

  • PDF

Effects of Alloying Elements on Hardening of 13Cr Stainless Steels Using Plasma Nitriding Process (플라즈마질화처리에 의한 13Cr 스테인리스강의 표면경화특성에 미치는 질화물형성원소첨가의 영향)

  • ;;;;中田一博
    • Journal of Welding and Joining
    • /
    • v.16 no.1
    • /
    • pp.88-97
    • /
    • 1998
  • The surface characteristics of 13Cr stainless steel systems by plasma nitriding were investigated. The plasma nitriding for the 13Cr steels, in which the nitriding forming elements such as Ti, V, W, Nb, Al, Zr and Si were added about 2~3wt.%, respectively, was performed. In all nitrided specimens, .epsilon.-F $e_{2-3}$N, UPSILON.'-F $e_{4}$N and CrN were detected as the nitrides with the a-Fe in the nitrided layer. VN and .betha.- $W_{2}$N were also detected in 13Cr-3V and 13Cr-3W alloys. The growth of the nitrided layer was controlled by the diffusion process. The thickness of the nitrided layer was similar in the 13Cr-2Nb and 3Zr specimens to that of 13Cr(BM) specimen, while the others exhibited the thinner layer. The activation energy for the growth of the nitrided layer in the temperature range of 773-873K was about 130kJ/mol in 13Cr(BM), 13Cr-2Ti, 3W, 3Al, 3Zr and 3Si alloys. The hardness of the nitrided specimens was significantly increased above Hv1000, comparing to the non-nitrided specimen. The specimens with the nitrided forming elements revealed much higher hardness values and, especially, 13Cr-3Al, 3V and 3Si specimens were significantly hardened up to Hv1300.v1300.0.

  • PDF

Characterizations of the Mechanical Properties and Wear Behavior of Ni Plate Fabricated by the Electroforming Process (Electroforming을 이용하여 제조한 Ni 기판의 기계적 특성 및 내마모 거동 분석)

  • Lee, Seung-Yi;Jang, Seok-Hern;Lee, Chang-Min;Choi, Jun-Hyuk;Joo, Jin-Ho;Lim, Jun-Hyung;Jung, Seung-Boo;Song, Keun
    • Korean Journal of Materials Research
    • /
    • v.17 no.10
    • /
    • pp.538-543
    • /
    • 2007
  • We fabricated the Ni plate by electroforming process and evaluated the microstructure, mechanical properties and wear behavior of the Ni plate. Specifically, the effects of addition of wetting agents, SF 1 and SF 2 solutions, on the microstructure and properties were investigated. The microstructure and surface morphology were characterized by transmission electron microscopy (TEM) and atomic force microscopy (AFM), respectively, and friction coefficient was measured by the ball-on-disk method. We found that the microstructure and mechanical properties of Ni plate were changed with kind and amount of wetting agents used. The hardness and tensile strength of Ni plate formed without wetting agents was 228 Hv and 660.7 MPa, respectively, whiled when wetting agent was added, those were improved to be 739 Hv and 1286.3 MPa. These improvements were probably due to the finer grain size and less crystallization of Ni. In addition, when both wetting agents were added, the friction coefficient was reduced from 0.73 to 0.67 which is partially caused by the improved hardness and smooth surface.

Castleman's Disease of the Neck and Mediastinum (경부와 종격동에 발생한 캐슬만씨 병(Castleman's Disease))

  • Nam Kee-Hyun;Choi Hyun-Ho;Lim Chi-Young;Lee Jan-Dee;Kim Seung-Il;Chang Hang-Seok;Hong Soon-Won;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.21 no.1
    • /
    • pp.48-52
    • /
    • 2005
  • Objectives: Castleman's disease(CD) is a lymphoproliferative disorder of unknown etiology. To elucidate the clinicopathologic characteristics of CD, we retrospectively reviewed our experience. Methods: Fifteen patients with CD of the neck and mediastinum were identified. Patients were divided into two groups: group I had an unicentric CD and group II had multicentric CD. The histology of CD was divided into 3 subtypes: hyaline-vascular(HV), plasma cell(PC), and mixed. Results: The study included 12 cases of group I, 3 cases of group II in the clinical aspect and 10 cases with HV, 3 cases with PC, 2 cases with mixed type in the histologic aspect. Of group I patients who underwent complete surgical excision, all are currently free of disease. The clinical course of group II patients was variable. Of two patients with multicentric plasma cell CD who were treated, one remain free from disease and the other had a local recurrence in the neck. One patient with multicentric mixed CD died of disease after 30 months of presentation. Conclusion: Surgical resection is recommend for patients with the unicentric CD, regardless of histologic subtype. Patients with multicentric disease do not benefit from surgical resection and should be candidates for multimodality therapy.