• Title/Summary/Keyword: HUM

Search Result 531, Processing Time 0.024 seconds

Zeolites: Their Features as Pressure Swing Adsorbents and CO2 Adsorption Capacity (제올라이트: 압력순환형 흡착제로서의 특성과 CO2 흡착성능)

  • Kim, Moon-Hyeon;Cho, Il-Hum;Choi, Sang-Ok;Choo, Soo-Tae
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.943-962
    • /
    • 2014
  • Industrial gas drying, dilute gas mixtures purification, air fractionation, hydrogen production from steam reformers and petroleum refinery off-gases, etc are conducted by using adsorptive separation technology. The pressure swing adsorption (PSA) has certain advantages over the other methods, such as absorption and membrane, that are a low energy requirement and cost-effectiveness. A key component of PSA systems is adsorbents that should be highly selective to a gas being separated from its mixture streams and have isotherms suitable for the operation principle. The six standard types of isotherms have been examined in this review, and among them the best behavior in the adsorption of $CO_2$ as a function of pressure was proposed in aspects of maximizing a working capacity upon excursion between adsorption and desorption cycles. Zeolites and molecular sieves are historically typical adsorbents for such PSA applications in gas and related industries, and their physicochemical features, e.g., framework, channel structure, pore size, Si-to-Al ratio (SAR), and specific surface area, are strongly associated with the extent of $CO_2$ adsorption at given conditions and those points have been extensively described with literature data. A great body of data of $CO_2$ adsorption on the nanoporous zeolitic materials have been collected according to pressure ranges adsorbed, and these isotherms have been discussed to get an insight into a better $CO_2$ adsorbent for PSA processes.

Titanium Mesh Cage for Anterior Stabilization in Tuberculous Spondylitis : Is It Safe?

  • Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Kim, Seung-Bum
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.6
    • /
    • pp.412-418
    • /
    • 2006
  • Objective : The safety of titanium metal cages in tuberculous spondylitis has not been investigated. We evaluated the outcome and complications of titanium mesh cages for reconstruction after thoracolumbar vertebrectomy in the tuberculous spondylitis. Methods : There were 17 patients with 18 operations on the tuberculous spondylitis in this study. Sixteen patients were operated with anterior corpectomy and reconstruction with titanium mesh cage followed by posterior transpedicular screw fixations on same day, two pateints were operated by either anterior or posterior approach only. After the affected vertebral body resection and pus drainage from the psoas muscle, titanium mesh cage, filled with morselized autogenous bone, was inserted. All the patients had antituberculosis medication for 18 months. The degree of kyphosis correction and the subsidence of cage were measured in the 15 patients available at a minimum of 2 years. Outcome was assessed with various cross-sectional outcome measures. Recurrent infection was identified by serial ESR[Erythrocyte Sedimentation Rate] and CRP[Cross Reactive Protein]. Results : There was no complication from the use of a titanium mesh cage. Recurrent infection was not detected in any case. Average preoperative of $9.2^{\circ}$ was reduced to $-2^{\circ}$ at immediate postoperative period, and on final follow up period kyphotic angle was measured to be $4.5^{\circ}$. Postoperatively, subsidence was detected in most patients especially at ambulation period, however further subsidence was prevented by the titanium mesh cage. Osseous union was identified in all cases at the final follow-up. Conclusion : The cylindrical mesh cage is a successful instrument in restoring and maintaining sagittal plane alignment without infection recurrence after vertebrectomy for tuberculous spondylitis.

Efficacy of Calcium Sulfate Pellets as Bone Graft Substitute in Lumbar Posterolateral Fusion - Preliminary Report - (요추부 후측방 유합술에서 골편대체물로서 황산칼슘의 효과에 대한 연구)

  • Lee, Seung Ku;Kim, Choong Hyun;Cheong, Jin Hwan;Bak, Koang Hum;Kim, Jae Min;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.5
    • /
    • pp.605-610
    • /
    • 2001
  • Objective : The authors investigated the efficacy of the calcium sulfate(OsteoSet$^{(R)}$ pellets) as an autograft extender when used to perform posterolateral lumbar fusions. Patients and Methods : Twenty patients who underwent lumbar posterolateral arthrodesis for various spinal diseases between October 1999 and March 2000 were evaluated. Arthrodesis was performed by transpedicular screw fixation and bone grafting with a mixture of autograft + calcium sulfate in a 1 : 1 ratio. At time intervals of 1, 2, 3, and 6 months, postoperative radiographs were obtained to review the resorption of calcium sulfate and the evidence of fusion. A modified Lenke scale was used to assess the status of the fusion. Results : At 2 months after operation, the average modified Lenke scale score for the OsteoSet$^{(R)}$ pellets group was 3.8. However at 6 months after operation, the average modified Lenke scale score for the OsteoSet$^{(R)}$ pellets group was 1.8. Resorption of calcium sulfate pellets was revealed in all cases at 6 months after surgery. Conclusion : It is presumed that a combination of calcium sulfate and autograft can play a role as an effective autograft extender in the posterolateral spinal fusion.

  • PDF

Biomechanical Testing of Anterior Cervical Spine Implants: Evaluation of Changes in Strength Characteristics and Metal Fatigue Resulting from Minimal Bending and Cyclic Loading

  • Kim, Sung-Bum;Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.217-222
    • /
    • 2005
  • Objective: To achieve optimal fit of implant, it is necessary to bend the implant during spine surgery. Bending procedure may decrease stiffness of plate especially made of titanium and stainless steel. Typically titanium suffers adverse effects including early crack propagation when it is bent. We investigate whether 6 degree bending of titanium plates would decrease the stiffness after full cyclic loading by comparing with non-bending titanium plates group. Methods: Authors experimented 40 titanium alloy plates of 57mm in length, manufactured by 5 different companies. Total 40 plates were divided into two groups (20 bent plates for experimental group and 20 non-bent plates for control group). Twenty plates of experimental group were bent to 6 degree with 3-point bending technique and verified with image analyzer. Using the electron microscope, we sought for a initial crack before and after 3-point bending. Mechanical testing by means of 6000 cyclic axial-compression loading of 35N in compression with moment arm of 35mm-1.1 Nm was conducted on each plate and followed by the electron microscopic examination to detect crack or fissure on plates. Results: The stiffness was decreased after 6000 cyclic loading, but there was no statistically significant difference in stiffness between experimental and control group. There was no evidence of change in grain structure on the electron microscopic magnification. Conclusion: The titanium cervical plates can be bent to 6 degree without any crack or weakness of plate. We also assume that minimal bending may increase the resistance to fatigue fracture in cervical flexion-extension movement.

Risk Factors for the Development and Progression of Atlantoaxial Subluxation in Surgically Treated Rheumatoid Arthritis Patients, Considering the Time Interval between Rheumatoid Arthritis Diagnosis and Surgery

  • Na, Min-Kyun;Chun, Hyoung-Joon;Bak, Koang-Hum;Yi, Hyeong-Joong;Ryu, Je Il;Han, Myung-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.590-596
    • /
    • 2016
  • Objective : Rheumatoid arthritis (RA) is a systemic disease that can affect the cervical spine, especially the atlantoaxial region. The present study evaluated the risk factors for atlantoaxial subluxation (AAS) development and progression in patients who have undergone surgical treatment. Methods : We retrospectively analyzed the data of 62 patients with RA and surgically treated AAS between 2002 and 2015. Additionally, we identified 62 patients as controls using propensity score matching of sex and age among 12667 RA patients from a rheumatology registry between 2007 and 2015. We extracted patient data, including sex, age at diagnosis, age at surgery, disease duration, radiographic hand joint changes, and history of methotrexate use, and laboratory data, including presence of rheumatoid factor and the C-reactive protein (CRP) level. Results : The mean patient age at diagnosis was 38.0 years. The mean time interval between RA diagnosis and AAS surgery was $13.6{\pm}7.0$ years. The risk factors for surgically treated AAS development were the serum CRP level (p=0.005) and radiographic hand joint erosion (p=0.009). The risk factors for AAS progression were a short time interval between RA diagnosis and radiographic hand joint erosion (p<0.001) and young age at RA diagnosis (p=0.04). Conclusion : The CRP level at RA diagnosis and a short time interval between RA diagnosis and radiographic hand joint erosion might be risk factors for surgically treated AAS development in RA patients. Additionally, a short time interval between RA diagnosis and radiographic hand joint erosion and young age at RA diagnosis might be risk factors for AAS progression.

Design, Fabricaiton and Testing of a Piezoresistive Cantilever-Beam Microaccelerometer for Automotive Airbag Applications (에어백용 압저항형 외팔보 미소 가속도계의 설계, 제작 및 시험)

  • Ko, Jong-Soo;Cho, Young-Ho;Kwak, Byung-Man;Park, Kwan-Hum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.408-413
    • /
    • 1996
  • A self-diagnostic, air-damped, piezoresitive, cantilever-beam microaccelerometer has been designed, fabricated and tested for applications to automotive electronic airbag systems. A skew-symmetric proof-mass has been designed for self-diagnostic capability and zero transverse sensitivity. Two kinds of multi-step anisotropic etching processes are developed for beam thickness control and fillet-rounding formation, UV-curing paste has been used for sillicon-to-glass bounding. The resonant frequency of 2.07kHz has been measured from the fabricated devices. The sensitivity of 195 $\mu{V}$/g is obtained with a nonlinearity of 4% over $\pm$50g ranges. Flat amplitude response and frequency-proportional phase response have been obserbed, It is shown that the design and fabricaiton methods developed in the present study yield a simple, practical and effective mean for improving the performance, reliability as well as the reproducibility of the accelerometers.

Comparing Difference of Volume of Psychiatric Treatments between the Patient with Health Insurance and Those with Medical Assistance - For Inpatients of Korean Psychiatric Hospitals - (건강보험과 의료급여 환자간의 정신요법 진료량 차이 비교 - 정신병원 입원환자를 대상으로 -)

  • Lee, Dae-Hee;Park, Eun-Cheol;Nam, Chung-Mo;Lee, Sang-Gyu;Lee, Dong-Han;Yu, Seung-Hum
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.1
    • /
    • pp.33-38
    • /
    • 2003
  • Objectives : To assess the difference in the volume of psychiatric treatments provided to health insurance inpatients, compared with those on medical assistance(the medical aid program) Korean psychiatric hospitals, and to determine factors which affect the volume of the services. Methods : 21 psychiatrists, from 3 Korean psychiatric hospitals recorded the frequencies psychiatric treatments provided to inpatients in one week (February 18-24, 2002). The records of 329 patients were analyzed through t-tests, and random effectmixed model analyses to define the difference between the two groups, and to find other factors affecting the volume of service. Results : A significant difference in the volume of psychiatric treatments provided was observed between the health insurance and medical assistance groups. The variation in the volume of service between hospitals was prominent, and other factors (gender, agegroup, length of stay and mental disorder)were also found to be significant. The patients on medical assistance received only 70% of the psychiatric treatments of those on health insurance. Conclusions : More effort is required to improve the methods of payment to increase the level of fee scheduling for medical assistance. Further studies on the mechanisms causing these differences in the volume of service are required.

A Comparison of Laparoscopic Cholecystectomy with Open Cholecystectomy in a Korean Hospital (복강경담낭절제술과 개복담낭절제술에 따른 진료량 비교)

  • Lee, Eun-Mee;Yu, Seung-Hum;Sohn, Myong-Sei;Kim, Suk-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.2 s.50
    • /
    • pp.325-333
    • /
    • 1995
  • Laparoscopic cholecystectomy was introduced into Korea in 1990 and has been rapidly replacing open cholecystectomy when the indications were met. In this study a medical utilization and technology was assessed on the selected hospitalized patients with cholelithiasis who underwent open or laparoscopic cholecystectomy from April 1, 1991 to March 31, 1994. The results are as follows. Despite the low reimbursement rate by the health insurance, the number of laparoscopic cases have been steadily increased. The post-operative days before health insurance coverage were significantly shortened from 8.4 days to 4.6 days. The preoperative days before health insurance coverage were significantly shorted from 8.4 days to 4.0 days. The total length-of-stays in the hospital were also significantly shortened from 15.2 days to 10.7 and 9.8 days in laparoscopic cholecystectomy. The laparoscopic cholecystectomy showed low expenses in all aspects expect the average hospital charges per day. For the hospital to have cost containment, it is more effective if length-of-stay is shorter because of high daily inpatient hospital charge. The laparoscopic cholecystectomy also showed shortened anesthesia time and operation time compared with open cholecystectomy that were statistically significant. The mean anesthesia and operation time for open cholecystectomy were 113.2 and 90.2 minutes but those of laparoscopic cholecystectomy were 105.7 and 68.6 minutes. According to this study the laparoscopic cholecystectomy has reduced the medical expenditure and we recommend this procedure over open cholecystectomy. The further discussion on the different morbidity rate between two types of procedure is essential in providing quality medical care, and to educate specialist.

  • PDF

Phenolic Compounds from the Leaves of Nelumbo nucifera Showing DPPH Radical Scavenging Effect (연잎에서 DPPH 라디칼 소거활성을 가지는 페놀성 화합물의 분리)

  • Park, Chan-Hum;Hur, Jong-Moon;Song, Kyong-Sik;Park, Jong-Cheol
    • Korean Journal of Pharmacognosy
    • /
    • v.38 no.3 s.150
    • /
    • pp.263-269
    • /
    • 2007
  • Nelumbo nucifera (Nymphaeaceae) has been widely used in a traditional oriental medicine to treat bleeding, fever, diarrhea, hemorrhoid, sunstroke, dysentery and dizziness. The leaves of this plant were refluxed with methanol, and then fractionated with organic solvents to screen the antioxidant activity using DPPH radical. Ethyl acetate and n-butanol fractions showed good DPPH radical scavenging effects and were carried out column chromatographies to isolate nine compounds. Their chemical structures were characterized as p-hydroxybenzoic acid (1), uracil (2), luteolin (3), quercetin $3-O-{\beta}-D-glucopyranoside$ (4), $rhamnetin 3-O-{\beta}-D-glucopyranoside$ (5), $isorhamnetin 3-O-{\beta}-D-glucopyranoside$ (6), $quercetin 3-O-{\beta}-D-glucuropyranoside$ (7), $quercetin 3-O-{\beta}β-D-xylofuranosyl(1{\rightarrow}2)-{\beta}-D-galactopyranoside$ (8), and adenine (9) by comparison NMR spectral data and with those in references. Compounds 1, 2, 5 and 9 were firstly isolated from this plant. Compounds 1, 3 and 4 showed potent DPPH radical scavenging activity. Especially, compound 3, luteolin showed the higher effect than ascorbic acid used as a positive control.

Vibration Health Monitoring of Helicopter Transmission Systems at Westland Helicopter Ltd.

  • Kang, Chung-Shin;Choi, Sun-Woo;Ahn, Seok-Min;Horsey, M.W;Stuckey, M.J
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.1
    • /
    • pp.48-61
    • /
    • 2000
  • Korea Aerospace Research Institute (KARI) have gained experience with Helicopter Vibration Health Monitoring (VHM) System technology with the help of UK GKN-WHL. GKN-WHL have had many years of experience with the research and development of vibration analysis techniques to improve the health monitoring of helicopter transmissions. This activity was targeted at transmission rig testing at first, but the techniques have been progressively developed where they are now used as a part of integrated Health and Usage Monitoring (HUM) systems on many types of in-service and new helicopters. The technique development process has been considerably aided by an ever expanding database of transmission monitoring experience from both the rig testing and aircraft operations. This experience covers a wide range of failure types from naturally occurring faults to crack propagation studies and covering a wide range of transmission configurations. Primarily based on accelerometer signals GKN-WHL's vibration analysis methods have also been applied to a variety of other sensor types. The transition from an experimental environment to operational VHM systems has been a lengthy process, there being a need to demonstrate technique reliability as well as effectiveness to both regulatory (Airworthiness Authority) and commercial organizations. Another important feature of this process has been the development of close relationships with a number of VHM system hardware and software suppliers. Such an experienced GKN-WHL provides various raw vibration data which was acquired from transmission ground test rig and allow KARI to develop it's own analysis program. KARI made a program and then analyzed the data to coma pre with the results of GKN-WHL. The KARI's results both time domain signals and statistical values show comparable to GKN's.

  • PDF