• 제목/요약/키워드: HU (House Field)

검색결과 4건 처리시간 0.018초

안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰 (CT Observation of Alloplastic Materials Used in Blow Out Fracture)

  • 이원;강동희
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Accelerated Thermal Aging Test for Predicting Lifespan of Urethane-Based Elastomer Potting Compound

  • Min-Jun Gim;Jae-Hyeon Lee;Seok-Hu Bae;Jung-Hwan Yoon;Ju-Ho Yun
    • Elastomers and Composites
    • /
    • 제59권2호
    • /
    • pp.73-81
    • /
    • 2024
  • In the field of electronic components, the potting material, which is a part of the electronic circuit package, plays a significant role in protecting circuits from the external environment and reducing signal interference among electronic devices during operation. This significantly affects the reliability of the components. Therefore, the accurate prediction and assessment of the lifespan of a material are of paramount importance in the electronics industry. We conducted an accelerated thermal aging evaluation using the Arrhenius technique on elastic potting material developed in-house, focusing on its insulation, waterproofing, and contraction properties. Through a comprehensive analysis of these properties and their interrelations, we confirmed the primary factors influencing molding material failure, as increased hardness is related to aggregation, adhesion, and post-hardening or thermal-aging-induced contraction. Furthermore, when plotting failure times against temperature, we observed that the hardness, adhesive strength, and water absorption rate were the predominant factors up to 120 ℃. Beyond this temperature, the tensile properties were the primary contributing factors. In contrast, the dielectric constant and loss tangent, which are vital for reducing signal interference in electric devices, exhibited positive changes(decreases) with aging and could be excluded as failure factors. Our findings establish valuable correlations between physical properties and techniques for the accurate prediction of failure time, with broad implications for future product lifespans. This study is particularly advantageous for advancing elastic potting materials to satisfy the stringent requirements of reliable environments.

의재(毅齋) 허백련(許百鍊) 남종화(南宗畵)의 예술심미 고찰 (The foundation and Characteristic on the Aesthetic of EuiJae Huh BaekRyun' Namjonghwa)

  • 김도영
    • 문화기술의 융합
    • /
    • 제6권3호
    • /
    • pp.1-8
    • /
    • 2020
  • 호남 남종화의 상징적 거목이자 호남문화의 스승으로 추앙받는 의재 허백련(1891~1977)은 진도출신으로 소치 허련의 방계이며, 미산 허형의 제자이다. 전통 남종화 정신과 그 기법에 충실한 화격(畫格)을 자득(自得)·자화(自化)하였다. 의재(毅齋)는 광주에서 '연진회(鍊眞會)'를 발족시켜 후진양성을 도모하였고, 해방 후 무등산 아래 산장을 짓고 다도인으로서, 그리고 민족정신을 강조하고 실천했던 사회교육자로서의 또 다른 면모도 보였다. 그는 한시와 화론에 조예가 깊었고, 서예에 있어서 독특한 심미경지를 구현하는 등 시(詩)·서(書)·화(畵) 삼절(三絶)의 전형적 서화가였다. 의재(毅齋)는 특히 산수화에서 탁월한 재능을 보였다. 그의 화풍은 예황풍(倪黃風)의 갈필(渴筆)로써 기존 화법을 준수하면서도 문기(文氣)를 중요시 여겼으며, 탈진습기(脫盡習氣)하여 새로운 실험정신으로 끊임없이 도전했다. 의재(毅齋)의 작품세계는 화풍이나 추구하는 관점의 변화를 작품에 사용한 낙관(落款)을 기준으로, 고법(古法)과 사의간원(寫意簡遠)의 숙련기였던 '의재(毅齋)'시대, 실경(實景)과 남화(南畵)의 융합 화풍으로 절정기를 보였던 '의재산인(毅齋散人)'시대, 청담평안(淸談平安)한 신품경지(神品境地) 구현으로 독자적 화풍을 이룬 '의도인(毅道人)'시대 등 총 3시기로 나누어 살펴볼 수 있다. 의재(毅齋)의 공헌은 동양회화의 지류인 한국회화문화의 정통 남종화에 대한 한 축을 이어왔다는 미술사적인 평가를 넘어 남도화의 보편적 정신과 지역적 특성을 바탕한 실경과 정서를 살린 창의적 계승을 통하여 현대를 잇는 조종(祖宗)이었음을 인식하고, 그의 예술정신과 전통에 대한 열정과 실험정신을 계승해야 할 것이다.

CT 조영제를 이용한 친환경적인 방사선 차폐에 관한 연구 및 고찰 (Research and Consideration of Eco-friendly Radiation Shielding using CT Contrast Agent)

  • 김성길;지연상
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.827-833
    • /
    • 2023
  • 방사선 촬영 조영제는 특수 조영을 필요로 하는 병원에서 인체 장기 및 특정한 부위 검사를 촬영할 때 흔히 쓰이고 있다. 특히 컴퓨터단층촬영(Computed Tomography CT) 조영제는 요오드(Iodine)라는 물질이 혼합되어 있는데 이것이 방사선의 에너지를 흡수하면서 방사선 영상 이미지에서 하얀색으로 보이게 되어 영상의 화질을 더욱 개선시킨다. 또한, 혈관에서 혈액과 같이 움직이는 CT 조영제는 근육 및 물과 확연히 구분을 시켜주고 있어 조영제를 병원에서 많이 사용하고 있다. 이러한 조영제는 엑스레이를 흡수하지만, 엑스레이를 흡수하기 위해서는 밀도가 높거나 방사선 흡수계수가 높아야 한다. 조영제가 혈관에 투입되기 때문에 밀도가 높으면 혈관에 무리가 가서 환자는 쇼크 상태가 오기 때문에 물과 비슷한 밀도를 맞춰야 하고 부작용에 대해 항상 신경을 써야한다. 또한, CT 조영제의 양을 환자의 체형에 따라 조절하면서 쓰고 남은 조영제를 폐기하는데 이것을 방사선 차폐재로 재활용을 할 수 있는 아이디어를 알아보고자 하였다. 조영제와 물을 혼합하는 방법에는 조영제 10%와 물 90%, 조영제 30%와 물 70%, 조영제 50%와 물 50%으로 3가지로 혼합하였다. CT 촬영은 광주광역시 U병원에서 GE사 4채널 CT를 사용하였으며 조영제와 물을 혼합하여 듀란병에 저장하였으며, 물 90%와 조영제 10% 혼합 액체의 밀도가 1.4 g/mL 정도일 때의 물질을 찾아보면 MYLAR라는 물질과 비슷한 것을 확인하였고, 물 70%와 조영제 30% 혼합 액체의 밀도가 1.76 g/mL일 때는 Polyvinylidene과 비슷한 물질인 것을 알 수 있었으며, 물 50%와 조영제 50%일 때 혼합 액체의 밀도는 2.3 g/mL일 때는 콘크리트(concrete) 밀도와 비슷한 밀도를 구성하고 있음을 알 수 있었다. 본 실험의 결과를 통해서 물 50%와 조영제 50%를 혼합한 액체는 콘크리트 차폐와 비슷한 밀도를 가지고 방사선의 차폐가 가능하였다. 따라서 콘크리트 두께와 비교하여 조영제를 50% 이상 첨가한 두께를 이용한 차폐재를 만든다면 충분한 차폐재의 역할을 할 수 있을 것으로 생각된다.