• Title/Summary/Keyword: HPLC-UV detector

Search Result 218, Processing Time 0.029 seconds

MEASUREMENT OF SYNTHESIS RATE OF LONG-CHAIN ACYL-COENZYME A ESTER IN BOVINE LIVER BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

  • Mitsuhashi, T.;Mitsumoto, M.;Yamashita, Y.;Ozawa, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.1 no.2
    • /
    • pp.99-106
    • /
    • 1988
  • A high performance liquid chromatographic procedure is described for the direct determination of the picomole amount of palmitoyl-Coenzyme A and stearoyl-Coenzyme A, using a stainless steel column packed with C-18 derivatized porous silica ($5{\mu}m$), an isocratic elution with a mixture of 33 mM $KH_2PO_4$/acetonitrile as a mobile phase and a UV detector. The long-chain acyl-Coenzyme A esters were determined in incubated microsomal fractions of a bovine liver to demonstrate the utility of this method for monitoring acyl-CoA synthesis in biological samples. The reaction rate of palmitate was higher than that of stearate. After a 60 minute incubation period, the generated amount of palmitoyl-Coenzyme A and stearoyl-Coenzyme A were approximately 70 and 20 n mol/mg micresomal protein, respectively. The advantage of this method are in that no decomposition of the CoA esters is involved, while the constituent molecular species is detected.

Determination of Trace Aldehydes in Ambient Air by Liquid Chromatography (액체 크로마토그래프법에 의한 대기시료중 미량 알데히드류의 정량)

  • 이용근;정태우
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.339-349
    • /
    • 1995
  • The purpose on this study is to optimize the chromatographic determination method of trace aldehydes in ambient air. Carbonyl compounds in urban air were trapped at $C_{18}$ DNPH-coated cartridges, and generated hydrazone derivatives were separated by HPLC and detected by UV-vis spectroscopic detector at 360nm. Formaldehyde and acetaldehyde compounds could be isolated from urban(Seoul) air with more than 95% collection efficiency. The analytical detection limits for formaldehyde and acetaldehyde are 0.06pp $b_{v}$, 0.08pp $b_{v}$ for 108 L air samples, respectively. The precision of this method are 3 .sim. 4%(RSD) for mutiple injection of hydrazone standards. Separation of seven dinitrophenylhydrazones could be achieved in appoximately 20 minutes operation time using $C_{18}$ column with apprepriate eluent. The method was applied to the analysis of aldehydes and ketone in Seoul ambient air. The 24-h ambient levels of formaldehyde, acetaldehyde reached up to 6 .sim. 14 and 3 .sim. 8ppbv, respectively. The daily average concentration ratio were 0.60 for acetaldehyde/formaldehyde.yde.

  • PDF

Determination of Prednisolone in Tablets by High Performance Liquid Chromatography (HPLC를 이용(利用)한 제제중(製劑中) 프레드니솔론의 함량균일성시험(含量均一性試驗)에 관한 연구(硏究))

  • Kim, Hyung-Kook;Lee, Cheol-Kyu;Ko, Geun-Il;Kim, Jae-Back
    • Journal of Pharmaceutical Investigation
    • /
    • v.13 no.2
    • /
    • pp.59-65
    • /
    • 1983
  • A convenient high performance liquid chromatographic method for the quantitative determination and content uniformity of prednisolone in tablets is described. The prednisolone was chromatographed using a ${\mu}-Bondapak\;C_{18}$ column and the eluent 70% MeOH at a flow rate 1. 0ml/min. Diethylstilbestrol was used as an internal standard. The UV detector response at 254nm was linear over a range of $10{\sim}60{\mu}g/ml$ under conditions of the analysis. Reproducibility studies gave relative standard deviations of $0.3{\sim}0.5%$.

  • PDF

Analysis of Medicinal Plants in Cosmetics(I) Determiantion of Korean Angelica Extract and Cnidium Rhizome Extract in bath Essence (화장품중 생약성분의 분석(I) 육제중의 당귀 및 천궁추출액의 함량분석)

  • 이보섭;김진우
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.16 no.1
    • /
    • pp.30-39
    • /
    • 1990
  • Angelica gigas extract and Cnidium of ficinale extract in Bath essence were determined by high performance liquid chromatography with a UV detector by use of Bondapak C-18 column. Decursin and Ligustilide were used as indicator ingredient for analysis of Angelica gigas extract and Cnidium of ficinale extract. Each indicator ingredient was isolated from each plant and purified using silver-ni-trate treated silica column. Their structure were conformed with IR, NMR and HPLC. The recoveries of Angelica gigas extract and Cnidium officinale extract added to Bath essence sample were 96.5-109.5% and 112-115%.

  • PDF

Quality Control of Adenophorae Radix

  • Park, Yun-Kyung;Yoo, Hye-Hyun;Baek, Seung-Hoon;Lee, Seung-Ho;Kim, Chang-Min;Lee, Kyung-Soon;Park, Man-Ki;Park, Jeong-Hill
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.221.3-222
    • /
    • 2003
  • Adenophorae Radix, the roots of Adenophora triphylla var. japonica Hara (Campanulaceae) is known to be an anti-inflammatory and antitussive drug used for the treatment of lung disease. However quality control method is not established yet. This study is to establish the quality control method of Adenophorae Radix.From the roots of this plant, we isolated (6R,7R)-E,E-tetradeca-4,12-diene-8,10-diyne-1,6,7-triol (1) as a marker compound for the quality control and determined its content by HPLC-UV detector. (omitted)

  • PDF

Risperidone pharmacokinetics in relation to CYP2D6 and MDR1 in healthy male Korean subjects

  • Kang, Hyun-Ah;Cho, Hea-Young;Lee, Suk;Baek, Seung-Hee;Lee, Yong-Bok
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.238.2-239
    • /
    • 2003
  • The purposes of this study were to evaluate the relationship between the genetic polymorphisms in CYP2D6*10 allele, MDR1 (exon 21 and 26) gene and risperidone pharmacokinetics in healthy male Korean subjects. A single dose of 2 mg risperidone tablet was given orally to 23 healthy male Korean volunteers. Blood samples were taken during the 12 hours after the dose. Serum concentrations of risperidone and 9-hydroxyrisperidone were measured using HPLC with UV detector. 23 subjects were genotyped for CYP2D6*10 allele, MDR1 G2677 T and C3435T by polymerase chain reaction-restriction fragment length polymorphism(PCR-RFLP). (omitted)

  • PDF

Determination of Cyhalofop-butyl and its Metabolite in Water and Soil by Liquid Chromatography (LC를 이용한 물과 토양 중 Cyhalofop-butyl과 대사물질의 분석)

  • Hem, Lina;Choi, Jeong-Heui;Liu, Xue;Khay, Sathya;Shim, Jae-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.4
    • /
    • pp.315-322
    • /
    • 2008
  • In this study, a simple, effective, and sensitive method has been developed for the quantitative residue analysis of cyhalofop-butyl and its metabolite cyhalofop acid in water and soil when kept under laboratory conditions. The content of cyholofop-butyl and cyhalofop acid in water and soil was analyzed by first purifying the compounds through liquid-liquid extraction and partitioning followed by Silica gel (adsorption) chromatography. Upon the completion of the purification step the residual levels were monitored through high-performance liquid chromatography (HPLC) using a UV absorbance detector. The recoveries of cyhalofop-butyl from three replicates spiked at two different concentrations ranged from 82.5 to 100.0% and from 66.7 to 97.9% in water and soil, respectively. The limit of detection and minimum detection level of cyhalofop-butyl in water and soil was 0.02 ppm and 10 ng, respectively. The recoveries of cyhalofop acid ranged from 80.7 to 104.8% in water and from 76.9 to 98.1 % in soil. The limit of detection of cyhalofop acid was 0.005 ppm in water and 0.01 ppm in soil, while the minimum detection level was 2 ng both in water and soil. The half-live of cyhalofop-butyl was 4.14 and 6.6 days in water and soil, respectively. The method was successfully applied to evaluate cyhalofop-butyl residues in water and soil applied aj. 30% emulsion, oil in water (EW) product.

Monitoring and risk assessment of pesticide in school foodservice products in seoul, Korea (서울지역 학교급식 식재료의 잔류농약 위해성 평가)

  • Seo, Young-Ho;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.21 no.1
    • /
    • pp.69-74
    • /
    • 2014
  • We tested for residual pesticide levels in school foodservice agricultural products in Seoul, Korea from 2010 to 2012. A total of 316 samples of 23 different types of agricultural products were analyzed via gas chromatography-nitrogen phosphate detector (GC-NPD), an electron capture detector (GC-${\mu}ECD$), a mass spectrometry detector (GC-MSD), and a high performance liquid chromatography-ultraviolet detector (HPLC-UV). We used multi-analysis methods to analyze 185 different pesticide types. Among the selected agricultural products, residual pesticides were detected in 26 samples (8.2%), of which 6 samples (1.9%) exceeded the Korea Maximum Residue limits (MRLs). We detected pesticide residue in more than 65% of the Chwinamul, while 6 among 9 analyzed samples contained pesticide residue, and 1 sample exceeded the Korea MRLs. Among the 185 kinds of pesticides that we have tested, 18 were detected, while 7 of them were detected more than twice. Data obtained were then used for estimating the potential health risks associated with the exposures to these pesticides. The most critical commodity is carbofuran in the perilla leaves, which has contributed 3.8% to the hazard index (HI). These results showed that the detected pesticides could not be considered as a serious public health problem. Nevertheless, constant supervision is recommended.

Simultaneous Determination of Six Bioactive Components in Guibi-tang by HPLC-DAD (HPLC-DAD를 이용한 귀비탕 중 6종 생리활성 물질의 동시분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.313-318
    • /
    • 2010
  • Guibi-tang, a traditional herbal medicine, is used for anti-oxidant, anti-osteoporosis, hemostasis and gastroprotection. To develop an analysis method of simultaneous determination of six compounds, swertisin, decursinol, glycyrrhizin, 6-gingerol, costunolide and decursin in Guibi-tang, a high performance liquid chromatography was used with diode array detector. Six bioactive components were separated on a SHISEIDO $C_{18}$ column ($5\;{\mu}m$, 4.6 mm I.D.${\times}$250 mm) with column temperature $30^{\circ}C$. The gradient elution was composed of water with 0.1% trifluoroacetic acid (TFA) and acetonitrile. UV wavelength was set at 230 nm, 254 nm and 330 nm, respectively. Calibration curve showed good linear regression ($R^2$ > 0.9999). The limits of detection (LOD) and the limits of quantification (LOQ) ranged in 0.03 - 0.23 ${\mu}g/ml$ and 0.08 - $0.70\;{\mu}g/ml$, respectively. The RSD values of intra- and inter-day test were in the range of 0.03 ~ 0.96% and 0.01 ~ 1.46%, respectively. The evaluated results of accuracy test were varied from 92.28% ~ 105.14% with RSD < 1.60%. In conclusion, this developed simultaneous determination method was accuracy and sensitive to the quality evaluation of Guibi-tang.

Simultaneous Analysis of three Marker Components in Hwangryunhaedok-tang by HPLC-DAD (황련해독탕 중 3종 생리활성 물질의 HPLC-DAD 동시 정량분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • YAKHAK HOEJI
    • /
    • v.55 no.1
    • /
    • pp.64-68
    • /
    • 2011
  • In this study, a high performance liquid chromatography-diode array detector method was established, for simultaneous determination of three compounds, berberine, palmatine and geniposide in Hwangryunhaedok-tang, To develop and validate method, $C_{18}$ column (5 ${\mu}M$, 4.6 mm${\times}$250 mm) was used with gradient mobile phase, water containing 0.1% trifluoroacetic acid (TFA) and MeOH at the column temperature of $30^{\circ}C$. UV wavelength was set at 230 and 280 nm. Validation of the chromatography method was evaluated by linearity, precision and accuracy test. Calibration curve of standard components showed good linearity ($R^2$ > 0.9999). The limits of detection (LOD) and limits of quantification (LOQ) varied from 0.05 to 0.17 ${\mu}g/ml$ and 0.15 to 0.53 ${\mu}g/ml$, respectively. The relative standard deviations (RSDs) data of intra-day and inter-day test were in less than 2.99% and 1.90%, respectively. The results of the accuracy test were in the range of 98.36 to 102.52% with RSDs values 0.32 to 1.98%. The results of validation indicated that this method was a very accurate and sensitive assay.