• Title/Summary/Keyword: HPLC-MS-MS

Search Result 911, Processing Time 0.032 seconds

The separation of arsenic metabolites in urine by high performance liquid chromatography-inductively coupled plasma-mass spectrometry

  • Chung, Jin-Yong;Lim, Hyoun-Ju;Kim, Young-Jin;Song, Ki-Hoon;Kim, Byoung-Gwon;Hong, Young-Seoub
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.18.1-18.9
    • /
    • 2014
  • Objectives The purpose of this study was to determine a separation method for each arsenic metabolite in urine by using a high performance liquid chromatography (HPLC)-inductively coupled plasma-mass spectrometer (ICP-MS). Methods Separation of the arsenic metabolites was conducted in urine by using a polymeric anion-exchange (Hamilton PRP X-100, $4.6mm{\times}150mm$, $5{\mu}m$) column on Agilent Technologies 1260 Infinity LC system coupled to Agilent Technologies 7700 series ICP/MS equipment using argon as the plasma gas. Results All five important arsenic metabolites in urine were separated within 16 minutes in the order of arsenobetaine, arsenite, dimethylarsinate, monomethylarsonate and arsenate with detection limits ranging from 0.15 to $0.27{\mu}g/L$ ($40{\mu}L$ injection). We used G-EQUAS No. 52, the German external quality assessment scheme and standard reference material 2669, National Institute of Standard and Technology, to validate our analyses. Conclusions The method for separation of arsenic metabolites in urine was established by using HPLC-ICP-MS. This method contributes to the evaluation of arsenic exposure, health effect assessment and other bio-monitoring studies for arsenic exposure in South Korea.

Simultaneous Determination of Asperosaponins and Iridoid Glycosides from Dipsaci Radix by Using LC-ESI-MS Spectrometry (속단(Dipsaci Radix) 중 Asperosaponins 및 Iridoid glycosides의 LC-ESI-MS에 의한 동시분석)

  • Cho, Hwang-Eui;Son, In-Seop;Kim, Sun-Cheun;Son, Kun-Ho;Woo, Mi-Hee;Moon, Dong-Cheul
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.2
    • /
    • pp.137-146
    • /
    • 2012
  • Dipsaci Radix (Dipsacaceae) has been used as a tonic, an analgesic, anti-inflammatory and anti-complement agents in traditional herbal medicine for the therapy of low back pain, knee pain, rheumatic arthritis, traumatic hematoma, and bone fractures. A high-performance liquid chromatography-electrospray ionization-mass spectrometric method (HPLC-ESI-MS) was developed for the simultaneous quantitation method of the five compounds from the herbal drug: asperosaponin VI and asperosaponin XII (terpene glycosides), sweroside, loganin and dipsacus A(iridoid glycosides). HPLC separation of the analytes was achieved on a C18 column ($150{\times}2.0$ mm i.d., 5 ${\mu}m$) using the aqueous methanol containing 5 mM ammonium acetate with gradient flow of the mobile phase. Detection of the analytes was performed by positive ion electrospray ionization, and selected ion monitoring was used for data acquisition using m/z corresponding molecular adduct ion, $[M+NH_4]^+$ and $[M+H]^+$. Calibration graphs showed good linearity ($r^2$=0.9997) over the wide range of the analytes; intra- and inter-day precisions (RSD, %) were within 9.1% and the accuracy between 94.0-111.0%. Recoveries of the analytes through the assay procedure were in the range of 93.7-110.8%. Analytical results of the herbal drugs of Dipsaci Radix (17 samples) show wide distribution of the five marker compounds and clear difference of the species from Phlomidis Radix (4 samples). The developed method would provide a practical guide for the quality control of the herbal drug.

Simultaneous Analysis of Bioactive Metabolites from Rehmannia glutinosa by HPLC-DAD-MS/MS

  • Won, Tae-Hyung;Ryu, Sung-Kwang;Kang, Sam-Sik;Shin, Jong-Heon
    • Natural Product Sciences
    • /
    • v.16 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • A high-performance liquid chromatography (HPLC) with diode array detector (DAD) and electrospray ionization mass spectrometry (ESI-MS) was established for the simultaneous determination of five representative metabolites of the iridoid and phenolic classes from Rehmannia glutinosa. The optimal chromatographic conditions were obtained on an ODS column (5 mm, $4.6{\times}250\;mm$) with the column temperature at $25^{\circ}C$. The mobile phase was composed of water and acetonitrile using a gradient elution with the flow rate 0.3 mL/min. Detection wavelength was set at 205 nm. All calibration curves showed good linear regression ($r^2$ > 0.997) within test ranges. Limits of detection (LOD) and quantitation (LOQ) values were lower than 0.123 and $0.373\;{\mu}g/mL$, respectively. The developed method provided satisfactory precision and accuracy with overall intra-day and inter-day variations of 0.09 - 0.76% and 0.16 - 1.41%, respectively, and the overall recoveries of 99.03 - 102.67% for all of the compounds analyzed. In addition, effectiveness of diverse extraction methods was compared to each other for the development of standard analytic method. The verified method was successfully applied to the quantitative determination of five representative metabolites in twenty-one commercial Rehmannia glutinosa samples from different markets in Korea and China. The analytical results showed that the contents of the five analytes vary significantly with sources.

Simultaneous Determination of Phenobarbital, Pentobarbital, Amobarbital and Secobarbital in Raw Milk via Liquid Chromatography with Electron Spray Ionization Tandem Mass Spectrometry

  • Tian, Huaixiang;Zhou, Xingxin;Chen, Chen;He, Yabin;Yu, Haiyan;Zheng, Xiaoping
    • Food Science of Animal Resources
    • /
    • v.37 no.6
    • /
    • pp.847-854
    • /
    • 2017
  • A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of four barbiturates (phenobarbital, pentobarbital, amobarbital and secobarbital) in raw milk. The barbiturates were extracted using liquid-liquid extraction, ultrasonication and centrifugation, and purified on an SPE column. Analytes were separated by HPLC on a CSH C18 column eluted using an acetonitrile-water system with a linear gradient dilution programme, and detected by MS/MS. The recoveries of the barbiturates were 85.0-113.5%, and the intra- and inter-assay RSDs were less than 9.8% and 7.3%, respectively. The limit of detection was 5 ng/mL for all four of the barbiturates. The analytical method exhibited good linearity from 10 to 1000 ng/mL; the correlation coefficient ($r^2$) was greater than 0.9950 for each barbiturate. This method was also applied to the determination of barbiturates in real milk samples and was found to be suitable for the determination of veterinary drug residues in raw milk.

Method for Simultaneous Determination of Cyanotoxins in Water by LC-MS/MS (액체크로마토그래프/질량분석기를 이용한 수중 남조독소물질 동시분석법)

  • Kim, Jeong-Hee;Yun, Mi-Ae;Kim, Hak-Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.597-605
    • /
    • 2009
  • Algae bloom occurred in reservoir in summer can cause taste and odor in water and disturb the flocculation and sedimentation processes in water treatment plant and cause sand filter plugging. It was also reported that microcystins, anatoxin and saxitoxin released from cyanobacteria had acute toxic effects on liver and nervous system. For these reasons, many advanced countries inclusive of WHO set the guideline for these toxins and cyanotoxins have been managed with regular monitoring in Korea as well. However, complex sample preparation steps such as a solid phase extraction (SPE) and derivatization are required with an existing analysis method with HPLC. We needed to improve an analysis method for low extraction efficiency and long sample preparation time. In this study, we have established a new LC/MS/MS method which can simultaneously determine 6 cyanotoxins (Microcystins-LR, Microcystins-RR, Microcystins-YR, Anatoxin-a, Saxitoxin, Neosaxitoxin) with only simple filtration step. When $75{\mu}L$ filterated sample was injected onto the LC-MS/MS, the recovery ranged from 86% to 112% and the MDL was $0.025{\sim}0.581{\mu}g/L$. We can make the MDL be lower than the guideline ($1{\sim}3{\mu}g/L$) of advanced countries with simple preparation.

LC-MS/MS Assay Validation for a New Immune Modulator, JHL45, and its Major Metabolite in Plasma: Application to Pharmacokinetic Studies in Rats

  • Baek, In-Hwan;Chae, Jung-Woo;Song, Gyu-Yong;Kwon, Kwang-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2631-2636
    • /
    • 2009
  • JHL45, a novel immune modulator for anti-atopic dermatitis and allergic airway disease, was synthesized from decursin isolated from Angelica gigas. In order to conduct a pharmacokinetic study of JHL45, an analytical method, ideally one that uses a minimal amount of biological sample must first be validated. In this study, a HPLC-MS/MS method was developed and validated for the quantification of JHL45 and its major metabolite, (+)-decursinol, from 10 ${\mu}L$ of rat plasma. JHL45 was stable under the analysis conditions, and intra- and inter-day accuracies exceeded 90.06%, with a precision variability ${\leq}$ 13.16% for each analyte. The mean values for Cmax, AUC8h, half-life of JHL45 in rats after intravenous administration of 5 mg/kg JHL45 were 24.59 μg/mL, 10.02 ${\mu}g{\cdot}h/mL$, and 1.88 h, respectively. The validated method herein will be useful for further pharmacokinetic studies of JHL45, as well as in preclinical and clinical phases.

Simultaneous Determination of 11 Marker Compounds in Gumiganghwal-tang by HPLC-DAD and LC-MS

  • Weon, Jin Bae;Jung, Youn Sik;Ryu, Gahee;Yang, Woo Seung;Ma, Choong Je
    • Natural Product Sciences
    • /
    • v.22 no.4
    • /
    • pp.238-245
    • /
    • 2016
  • Gumiganghwal-tang has been used for the treatment of common cold for a long-time. We developed an accurate and sensitive high performance liquid chromatography-diode array detection (HPLC-DAD) and electrospray ionization mass spectrometry method for the simultaneous determination of ferulic acid, baicalin, bergapten, methyl eugenol, glycyrrhizin, oxypeucedanin, wogonin, nodakenin, atractylenolide III, imperatorin, and atractylenolide I in Gumiganghwal-tang samples. The analytes were separated on a Shiseido C18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}250mm$) with gradient elution with acetonitrile and 0.1% trifluoroacetic acid. Eleven compounds were quantitatively determined by HPLC-DAD and identified by LC-MS data. We also validated this method. The calibration curves of all the compounds showed good linear regression. The limits of detection and the limits of quantification ranged from 0.04 to 0.63 and from 0.12 to $1.92{\mu}g/mL$, respectively. The relative standard deviation values of intra- and inter-days of this method represented less than 2.9%. The recoveries were found to be in the range of 90.06 - 107.66%. The developed method has been successfully applied to the analysis of Gumiganghwaltang samples. The established HPLC method could be used to quality control of Gumiganghwal-tang.

Identification of Novel Standard Compounds for Standardization of Sinbaro3 Pharmacopuncture (신바로3 약침의 표준화를 위한 지표물질 검색)

  • Lee, Jin-Ho;Lee, Jae-Woong;Kim, Min-Jeong;Kim, Eun-Jee;Lee, In-Hee
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.2
    • /
    • pp.65-72
    • /
    • 2015
  • Objectives To investigate and validate potential standard compounds for standardization of Sinbaro3 pharmacopuncture prepared at OO Hospital of Korean Medicine. Methods Sinbaro3 pharmacopuncture was prepared by extraction, purification and hydrolysis of Harpagophytum procumbens, and various potential standard compounds were quantified through HPLC-UV and HPLC-MS analysis. Validation was examined by assessing specificity, linearity, precision, and accuracy. Results The retention time of harpagide and cinnamic acid were 15.2 min and 28.2 min, respectively, and both showed good linearity in analysis by concentration at 0.9999 and 0.9998, respectively. Intra-day variation of precision was 0.0015~0.0045% and 0.0058~0.1629%, while inter-day variation of precision was 0.0011~0.0243% and 0.0098~0.1629%, and that of accuracy was 99.53~99.89% and 99.50~99.91%, respectively. Conclusions Harpagide and cinnamic acid, which are hydrolyzates of harpagoside within Sinbaro3 pharmacopuncture, were both validated using HPLC-MS and HPLC-UV analysis, and Sinbaro3 pharmacopuncture contained 78.41 ug/ml harpagide, and 2.05 ug/ml cinnamic acid.

Determination of thyroid hormones by solid-phase extraction using high performance liquid chromatograph/diode array detector/electro-spray ionization mass spectrometry in urine samples (HPLC/DAD/ESI-MS 및 고체상 추출법을 이용한 뇨시료중 갑상선 호르몬 분석)

  • Kwak, Sun Young;Moon, Myeong Hee;Pyo, Heesoo
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.519-528
    • /
    • 2006
  • An analytical method for the determination of thyroid hormones in urine samples has been studied by using solid-phase extraction and high-performance liquid chromatography/diode array detector/electro-spray mass spectrometry. Seven thyroid hormones were successfully separated by gradient elution on the reverse phase Hypersil ODS column (4.6 mm I.D., 100 mm length, particle size $5{\mu}m$) with ammonium formate buffer and acetonitrile, and UV spectra and mass fragment could be confirmed. The extraction recoveries of thyroid hormones in the urine samples (pH 3) were in the range of 89.0-113.1% with solid-phase extraction by C18, followed by elution with 4 ml of methanol/ammonium hydroxide (9 : 1). The calibration curves showed good linearity with the correlation coefficients ($r^2$) varying from 0.992 to 0.998 and the detection limits of all analytes were obtained in the range of 2-4 ng/ml (3.8-13.0 pmol/ml).

Application of Physiologically Based Pharmacokinetic Modeling with Biological Monitoring Data for Risk Assessment (생물학적 모니터링 데이터를 기초한 PBPK 모델의 활용)

  • Yang, Mi-Hi;Yang, Ji-Yeon;Yi, Bit-Na;Lee, Ho-Sun
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.1 s.56
    • /
    • pp.1-8
    • /
    • 2007
  • Biological monitoring, analyses of internal dose for exposure to toxicants, has been thought as one of the belt approaches for risk assessment. As the amount detected in human samples is generally very low, typically in the parts-per-bilion (ppb) or parts-per-trillion (ppt) range, analytic technologies such at HPLC, GC/MS, LC/MS, and LC/MS/MS have been continuously developed. In addition, route specific and sensitive exposure biomarkers have been developed for proper biological monitoring. PBPK modeling, particularly reverse dosimetry, has been emphasized as an useful method via interpretation of biological monitoring results for regulation of toxicants. Thus, this review is focused on the use of PBPK dosimetry models for toxicology research and risk assessment in Korea.