• 제목/요약/키워드: HPLC quantification

검색결과 403건 처리시간 0.032초

HPLC-PDA를 이용한 정향(Eugenia caryophyllata) 중의 eugenol 분석법 확립 및 검증 (Determination of eugenol in Eugenia caryophyllata by high-performance Liquid chromatography with photodiode array detection and method validation)

  • 윤형준;윤소미;이명헌;손성완
    • 대한수의학회지
    • /
    • 제48권1호
    • /
    • pp.9-16
    • /
    • 2008
  • A method for the quantification of eugenol in the medicinal herb Clove was developed and validated. For preparation of sample solutions clove was dried at $60^{\circ}C$ for 2h and ground by mixer and extracted with 95% ethanol for shaking extraction. The elutes were analyzed by HPLC system included a reversed phase column, a isocratic mobile phase of 60% methanol and PDA detector set at 280 nm. Calibration graphs were linear with very good correlation coefficients ($r^2>0.9999$) from $0.0125~1{\mu}g/ml$. The limit of detection per sample injection ($20{\mu}l$) was $0.81ng/{\mu}l$ and limit of quantification was $2.47ng/{\mu}l$. The method showed good intra-day precision (%RSD 0.08 ~ 0.27%) and inter-day precision (%RSD 0.32 ~ 1.19%).

Simultaneous Determination of Albiflorin, Cinnamaldehyde, Cinnamic Acid, Daidzin, Glycyrrhizin, Liquiritin, Paeoniflorin and Puerarin in Galgeun-tang by HPLC-PDA

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • 대한한의학회지
    • /
    • 제31권6호
    • /
    • pp.8-15
    • /
    • 2010
  • Objectives: We investigated to develop and validate HPLC-PDA methods for simultaneous determination of eight constituents in Galgeun-tang (GGT). Methods: Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 230 nm, 254 nm, and 280 nm, were used for quantification of the eight marker components of GGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Results: Calibration curves were acquired with $r^2$ > 0.9999, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 3.0%. The recovery rate of each component was in the range of 87.33-101.38%, with an RSD less than 7.0%. The contents of the eight components in GGT were 1.98-12.17 mg/g. Conclusions: The established method will be applied for the quantification of marker components in GGT.

Validation and measurement uncertainty of HPLC-UV method for quercetin quantification in various foods

  • Seo, Eunbin;Lim, Suji;Yun, Choong-In;Shin, Jae-Wook;Kim, Young-Jun
    • 한국식품과학회지
    • /
    • 제53권6호
    • /
    • pp.682-687
    • /
    • 2021
  • The purpose of this study was to validate a high-performance liquid chromatography (HPLC) method for the quantitative analysis of quercetin in various foods. The method was based on HPLC-UV (360 nm). The method was validated using candy, beverage, and sausage which were tested for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. Matrix-matched calibration was also applied. The calibration curves (0.5-50 mg/L) showed good linearity (r2≥0.9998). LOD and LOQ ranged from 0.15 to 0.31 mg/kg and from 0.44 to 0.93 mg/kg, respectively. The average accuracy and precision at 0.5, 2.5, and 10 mg/kg ranged from 84.3 to 102.0% and 0.7 to 3.0 relative standard deviation (RSD%), respectively. This study confirmed the applicability of the proposed method by applying it to commercial products, such as teas and beverages. Thus, the proposed analytical method is suitable for quantifying quercetin in various foods.

꾸지뽕나무 뿌리로부터 Cudratricusxanthone A와 Cudraxanthone D의 분리 및 함량 분석 (Isolation and Quantitative Analysis of Cudratricusxanthone A and Cudraxanthone D from Roots of Cudrania tricuspidata Bureau)

  • 박수연;김은남;정길생
    • 생약학회지
    • /
    • 제50권1호
    • /
    • pp.59-64
    • /
    • 2019
  • Cudrania tricuspidata Bureau (Moraceae) has been used for physical weakness, impotence and insomnia in traditional Korean medicine. In this study, cudratricusxanthone A and cudraxanthone D were isolated from roots of C. tricuspidata and quantification were achieved by using high performance liquid chromatography (HPLC) method with diode array detector. The isolated compound was identified by NMR analysis and HPLC method was validated by linearity, precision and specificity test. The results showed that calibration curves of two compounds indicated great linearity with a correlation coefficient ($R^2$) of 0.9976 and 0.9995. The limits of detection (LOD) for cudratricusxanthone A and cudraxanthone D were 1.15, $0.11{\mu}g/ml$. Intra-day precision of cudratricusxanthone A and cudraxanthone D were 0.32~1.99%, 0.09~3.32% and inter-day precision were 0.59~2.40%, 0.28~1.55% RSD (%) values, respectively. The specificity was confirmed by chromatograph and quantitative contents of cudratricusxanthone A and cudraxanthone D were $0.46{\pm}0.02%$ and $1.53{\pm}0.06%$. Therefore, this study can be used as a basic research data for the quantitative analysis of derived compounds from roots of C. tricuspidata.

Analytical Quality by Design Methodology Approach for Simultaneous Quantitation of Paeoniflorin and Decursin in Herbal Medicine by RP-HPLC Analysis

  • Kim, Min Kyoung;Park, Geonha;Hong, Seon-Pyo;Jang, Young Pyo
    • Natural Product Sciences
    • /
    • 제27권4호
    • /
    • pp.264-273
    • /
    • 2021
  • Simultaneous quantification of multiple marker compounds in herbal medicine by high performance liquid chromatography (HPLC) analysis is still a challenge due to the complexity in various parameters to be considered and co-existing multi-components. As a case study, a reliable HPLC method for simultaneous quantification of paeoniflorin from Paeoniae Radix and decursin from Angelicae Gigantis Radix in various commercial herbal medicine was developed based on analytical quality by design (AQbD) strategy. As a first step, risk assessment was performed to select the critical method parameters (CMPs) which were decided as organic mobile phase ratio and column oven temperature. In order to evaluate the effect of the CMPs on critical method attributes (CMAs) of peak resolution and tailing, central composite design (CCD) was employed. The final chromatographic conditions were optimized as follows: column- C18, 4.6 × 250 mm, 5 ㎛ particle size; mobile phase- A: acetonitrile, B: 0.1% acetic acid water; detection wavelength- 235 nm for paeoniflorin, 325 nm for decursin; column oven temperature- 25℃; flow rate- 1.0 mL/min; gradient mobile phase system as Time (min) : % A, 0:14, 25:14, 30:50, 60:50, 61:100, 65:100, 66:14, 75:14. The method was successfully validated according to the International Conference on Harmonization (ICH) guidelines and piloted for ten commercial herbal medicines.

TLC를 이용한 이소플라본의 신속한 정량 분석 (Rapid Quantitative Analysis of Isoflavones using TLC)

  • 김경선;박관화;백무열;강길진;박천석
    • 한국식품과학회지
    • /
    • 제36권4호
    • /
    • pp.558-562
    • /
    • 2004
  • TLC를 이용하여 간편하고 신속하게 정량적인 이소플라본의 분석을 수행할 수 있는 조건을 개발하였다. 전개 용매로는 chloroform : methanol : water : acetic acid를 각각 60 : 30 : 10 : 0.5의 비율로 하였을 때 최적의 분리를 보였으며, 정량적인 분석은 UV에서의 흡광도를 densitometer를 사용하여 spot의 intensity를 계산함으로 가능하였다. HPLC분석법과의 비교 결과 $0.15-1.80{\mu}g/{\mu}L$의 범위에서 이소플라본을 정량적으로 분석할 수가 있었다. 또한 TLC를 이용하여 일반 콩과 식물에 포함되어 있는 이소플라본의 함량 측정 결과 HPLC의 결과와 상당히 근소한 값으로 일치하여 TLC방법으로 간편하고 빠르게 정량적인 측정이 가능함을 확인하였다.

Study on the Marker Steroids of New Zealand Deer (Cervus elaphus var. scoticus) Velvet Antler by UPLC-MS/MS and HPLC-PDA Methods - (II)

  • Lee, Nam Kyung;Jang, Kyoung Hwa;Lee, Jong Tae;Park, Hee Won;Han, Sung Tai;In, Gyo
    • Natural Product Sciences
    • /
    • 제25권1호
    • /
    • pp.49-58
    • /
    • 2019
  • Eleven steroid hormones (SHs: androstene-3,17-dione, estrone, ${\beta}$-estradiol, ${\alpha}$-estradiol, testosterone, dehydroepiandrosterone, $17{\acute{a}}$-hydroxyprogesterone, medroxyprogesterone, megestrol acetate, progesterone, and androsterone) were detected from New Zealand deer (Cervus elaphus var. scoticus) velvet antler (NZA, 鹿茸 ). A method for the quantification of eleven SHs was established by using ultraperformance liquid chromatography (UPLC)-MS/MS. The linearities ($R^2$ > 0.991), limits of quantification (LOQ values, 0.3 ng/mL to 23.1 ng/mL), intraday and interday precisions (relative standard deviation: RSD < 2.43%), and recovery rates (97.3% to 104.6%) for all eleven SHs were determined. In addition, a method for the quantification of three 7-oxycholesterols (7-O-CSs: 7-ketocholesterol, $7{\alpha}$-hydroxycholesterol, and $7{\beta}$-hydroxycholesterol) in the NZA was established by using an HPLC-photodiode array (PDA) method. The linearities ($R^2$ > 0.999), LOQ values (30 ng/mL to 350 ng/mL), intraday and interday precisions (RSD < 1.93%), and recovery rates (97.2% to 103.5%) for the three 7-O-CSs were determined. These quantitative methods are accurate, precise, and reproducible. As a result, it is suggested that the five steroid compounds of androstene-3,17-dione, androsterone, 7-ketocholesterol, $7{\alpha}$-hydroxycholesterol, and $7{\beta}$-hydroxycholesterol could be marker steroids of NZA. These methods can be applied to quantify or standardize the marker steroids present in NZA.

A HPLC-UV method for quantification of ivermectin in solution from veterinary drug products

  • Kim, Young-Wook;Jeong, Wooseog
    • 한국동물위생학회지
    • /
    • 제45권3호
    • /
    • pp.243-248
    • /
    • 2022
  • The HPLC conditions for analysis of ivermectin in solutions dosage forms of commercial anthelmintics are different for each product. The purpose of this study was to establish a standardized chromatographic method for the quantification of ivermectin in solution. The separation was achieved on Waters Xbridge C18 column (4.6×150 nm, 5 ㎛) using different kinds of mobile phase composed of water/methanol/acetonitrile (15/34/51, v/v and 19.5/27.5/53, v/v), with UV detection at wavelengths 245 nm and 254 nm. A total of five commercial ivermectin in solution samples were analyzed. In this study, the optimal chromatographic conditions for analysis of ivermectin in solution were mobile phase of water/methanol/acetonitrile (15/34/51, v/v) at a flow rate of 1.0 mL/min and a detection wavelength of 245 nm using a Waters Xbridge C18 column (4.6×250 nm, 5 ㎛) at a column temperature of 25℃. The linearity was observed in the concentration range of 50~150 ㎍/mL, with a correlation coefficient, r2= 0.99999. The limit of detection and the limit of quantification were 0.88 and 2.68 ㎍/mL, respectively. The accuracy (% recovery) was found to be 98.9 to 100.3%. Intra-day and Intermediate precisions with relative standard deviations were less than 1.0%. The content of ivermectin for five market samples ranged 91.2~102.7%. The proposed method was also found to be robust, therefore, the method can be used for the routine analysis of ivermectin in solutions dosage forms.

NIRS를 이용한 삼지구엽초의 이카린 함량 분석 (Quantification of Icariin Contents in Epimedium koreanum N. by Using a Near Infrared Reflectance Spectroscopy)

  • 김용호;최병열;백흠영;이영상
    • 한국약용작물학회지
    • /
    • 제10권5호
    • /
    • pp.340-343
    • /
    • 2002
  • 삼지구엽초에 함유되어 있는 icariin 함량을 신속하게 추정하기 위하여 NIRS(근적외선 분광분석기)를 이용한 분석 방법을 검토하였다. HPLC를 이용하여 분석된 삼지구엽초 유전자원 150계통에 대한 이카린 함량치를 NIRS 스펙트럼에 적용시켜 42개의 calibration set 와 26개의 valilion set를 구분하였다. NIRS의 검량식을 몇가지 방법에 의하여 비교분석한 결과 2차미분된 스텍트럼을 MPLS(Modified Partial Least Squares)를 이용한 회귀식에 이용하는 것이 가장 적합하였다. HPLC를 이용한 유전자원들의 이카린 함량은 평균 $0.424%(0.12{\sim}0.67%)$이었으며, NIRS에서 도출된 검량식과의 상관계수는 0.951을 나타내었다. 따라서 삼지구엽초의 이카린 함량은 NIRS를 이용하여 신속 편리하게 분석할 수 있음이 인정되었다.

후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구 (Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS)

  • 주민규;박명순;박용남
    • 분석과학
    • /
    • 제27권3호
    • /
    • pp.140-146
    • /
    • 2014
  • 후 컬럼 동위원소 희석법(PCID, post column isotope dilution)을 HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry)에 적용한 정량법에서 내부 표준물을 동시에 사용하여 정확도와 정밀도를 개선하였다. 전통적인 여러 정량법과 후 컬럼 동위원소 희석법을 비교하여 볼 때에 PCID의 경우에 컬럼내에서 발생하는 오차가 가장 큰 요인으로 작용하였음을 알 수 있었다. PCID에서 내부 표준물을 사용하여 컬럼내에서의 손실에 대한 오차를 효과적으로 보정하고 정확도와 정밀도를 개선할 수 있었다. 셀레늄 화학종인 SeMet을 시료로 사용하고 내부 표준물로 MeSecys 또는 $Se^{4+}$를 이용한 결과, 사용하지 않은 경우와 비교하면 상대오차는 각 각 31%와 13%에서 모두 1% 대로 낮아져 정확도가 크게 개선되었으며, 상대 표준편차는 5.1%와 6.9%에서 각각 1.5%와 0.2%로 정밀도 또한 크게 개선되었다. PCID에서 내부 표준물을 사용하였을 때의 정량분석법의 장점을 다른 분석법과 비교 토의하였다.