Development of Analytical Methods for Insect Moulting Hormone $({\beta}-Ecdysone)$ by HPLC/UV Using Boronate Derivatization

  • Shim, Jae-Han;Kim, In-Seon;Lim, Kye-Taek
    • Applied Biological Chemistry
    • /
    • 제41권4호
    • /
    • pp.251-256
    • /
    • 1998
  • The analytical method of ${\beta}-ecdysone$, the insect moulting hormone, by high performance liquid chromatograph (HPLC) with UV detector was developed using boronic ester derivatization and applied to the extracts of Ajuga iva, Silene otites and Schistocerca egg. Derivatization of yield with methyl-, butyl-, and phenyl-boronate was completed under mild conditions with 20-hydroxyecdysone. The conversion ratios of boronate were estimated to be 70% in methylboronic acid, 89% in butylboronic acid and 93% in phenylboronic acid. Phenylboronate showed a high sensitivity and demonstrated an effective separation on HPLC. The optimum temperature and reaction time for derivative formation were $25^{\circ}C$ and 20 min. respectively. ${\beta}-Ecdysone$ was effectively identified in extracts of Ajuga iva, Silene otites and Schistocerca egg by the HPLC method.

  • PDF

HPLC를 이용한 뇨 및 혈액중 Metocurine Iodide의 미량분석 (Microanalysis of Metocurine Iodide in Urine and Blood by HPLC)

  • 김경님;이종필;김효진;김박광
    • 약학회지
    • /
    • 제38권4호
    • /
    • pp.379-388
    • /
    • 1994
  • A new method for the analysis of metocurine iodide in biological fluids was developed. Metocurine iodide was quantitatively extracted with rose bengal from aqueous layer into dichloromethane layer and the amount of metocurine iodide was calculated from the amount of rose bengal which was determined by HPLC with fluorescence detector. It was possible to analyze metocurine iodide without the effect of co-prescribed drugs in the concentration range of $0.09{\sim}9.10\;{\mu}g/ml$. The detection limits of metocurine iodide in urine and blood were 0.8 and 1.2 ng at S/N=3, each respectively.

  • PDF

Compositional Sugar Analysis of Antitumor Polysaccharidees by High Performance Liquid Chromatography and Gas Chromatography

  • Kim, Yeong-Shik;Park, Kyung-Shin;Park, Ho-Koon;Kim, Sung-Whan
    • Archives of Pharmacal Research
    • /
    • 제17권5호
    • /
    • pp.337-342
    • /
    • 1994
  • Carbohydrate analysis is important in studying structure and activity of complex polysaccharides. New analytical method was applied to get an information on the composition of polysaccharides showing antitumor activity. Monosaccharides were labeled with 7-amino-1, 3-naph-thalenedisulfonic acid (7-AGA) by reductive amination and separated by HPLC. Five kinds of polysaccharides from Basidiomycetes were hydrolyzed and analyzed in combination with electrophresis and HPLC. At the same time, alditol acetate derivatives were prepared and analyzed by gas chromatography. Two different techniques using different derivatization methods showed very similar results. The monosaccharides from Coriolus versicolor and Cordyceps militaris were glucose and galactose. Phellinus linteus composed of glucose, glactose, mannose, arabinose and fucose. The HPLC method with fluorescence detector was very sensitive compared to other methods.

  • PDF

Simultaneous determination of bisphenol A, chlorophenols and alkylphenols by solid-phase extraction and HPLC

  • Lee, Taejoon;Park, Keun-Young;Pyo, Dongjin
    • 분석과학
    • /
    • 제30권1호
    • /
    • pp.20-25
    • /
    • 2017
  • An analytical method for determining potential endocrine disruptors (bisphenol A, 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol, p-t-butylphenol, p-pentylphenol, p-hexylphenol, p-t-octylphenol, p-heptylphenol, nonylphenol) by solid-phase extraction (SPE) and High Perfomance Liquid Chromatography(HPLC) equipped with fluorescence and variable wavelength detector has been developed. The SPE process for sample concentration was performed on a commercially available Oasis HLB cartridge packed with polymeric sorbents. The effect of elution solvent and elution volume on the recoveries of the analytes were investigated with HPLC. Average recovery of >85% was achieved with 60mg sorbents using 5mL of methanol as elution solvent. Phenolic compounds in canned drinks, beverages and water samples were surveyed by this proposed method.

HPLC를 이용한 돈육 중의 Oxytetracycline, Chloramphenicol 및 Sulfamethoxazole의 동시검출 (The Simultaneous Analysis of Oxytetracycline, Chloramphenicol and Sulfamethoxazole in Pork by HPLC)

  • 조혜연;조진국;이치호
    • 한국축산식품학회지
    • /
    • 제21권1호
    • /
    • pp.64-70
    • /
    • 2001
  • The extraction procedure and HPLC condition were modified to analyze the residues of oxytetracycline, sulfamethoxazole and chloramphenicol in pork, simultaneously. The antibacterial agents in pork were extracted with 0.02M EDTA-Mcilivine buffer:ethanol:acetonitrile (5:3:2). After the removal of fat with n-hexane, the extracts were evaporated and purified with Sep-pak $C_{18}$ cartridge column using 0.01M oxalic acid 0.1% (v/v) triethylamine (TEA) in acetonitrile. The peak of antibacterial agents was detected with $\mu$ Bondapak C18 column, UV detector (280nm) and 0.01M oxalic acid: methanol: acetonitrile (7.5:2.0:0.5). Detection limits for three antibacterial standards were 0.03 ppm. Calibration curves were linear between 0.03 and 2.0 ppm (R$^2$>0.999). When spiked the level of 1.0 ppm of oxytetracycline, sulfamethoxazole and chloramphenicol into meats, the recoveries from meats were 77.3%, 79.7% and 59.3%, respectively. These results showed that the modified extraction method provided good analytical resolution and the recoveries of the above antibacterial agents in meats.

  • PDF

HPLC에 의한 한국산 칡차의 분석 (Studies on the Content of Pueraria Radix in the Tea by HPLC)

  • 김명희;박성배
    • 한국식품위생안전성학회지
    • /
    • 제2권3호
    • /
    • pp.89-95
    • /
    • 1987
  • 시판 갈근으로부터 Isoflavanoid 성분인 Daidzein과 Daidzin을 분리 정제하고 이를 표준물질로 하여 시판 칡차 8종에 대한 칡성분 분석을 HPLC 방법으로 시도하여 다음과 같은 결론은 얻었다. 1. 칡차의 성분 분석법은 종래의 TLC법에 비하여 HPLC를 이용, 신속하고 정확하게 분석할 수 있었다. 2. 추출방법에 따라 성분함량이 크게 영향을 받아 Daidzein을 분석할 경우는 냉침법이, Daidzin의 분석시는 가열 추출법이 양호하였다. 3. 한국산 갈근중 Daidzein과 Daidzin은 0.08% 및 0.66% 함유되었다. 4. 시판 칡차중 고형차류는 칡의 성분이 표기량에 비하여 매우 적게 함유되거나 전혀 함유되지 않은 예도 있으며 액상차의 경우는 엑기스 고형분이 4∼5%가 함유되었다.

  • PDF

역상 HPLC에 의한 polysorbates의 산화에틸렌(EO) 분리 및 정량분석 (Determination and Ethylene Oxide(EO) Separation of Polysorbates by RP-HPLC)

  • 이용화
    • 한국응용과학기술학회지
    • /
    • 제29권4호
    • /
    • pp.585-593
    • /
    • 2012
  • 역상 HPLC에 의한 polysorbate 20, polysorbate 40, polysorbate 60, polysorbate 80의 ethylene oxide(EO)분리 및 간편하고 빠른 정량분석 방법을 개발하였다. 분석조건으로 분리관은 YMC Pack Ph ($250mm{\times}4.6mm$ i.d., $5{\mu}m$) 과 Phenomenex C4 ($250mm{\times}4.6mm$ i.d., $5{\mu}m$)을 사용하였고, 검출기는 ELSD를 사용하였으며, 이동상은 water/acetonitrile의 기울기 용리에 의해 분석되었다. 이때 검량선의 상관계수($r^2$)는 $180.2{\sim}980.5{\mu}g/mL$ 농도 범위에서 0.997이상 이었고, 검출한계, 정밀성이 우수하였다. 이 방법은 olysorbates의 산화에틸렌 분리분석 및 간편하고 빠르게 정량분석 가능함을 보여 주었다.

HPLC/DAD/ESI-MS를 이용한 혈장시료 중 갑상선 호르몬 분석 (Determination of thyroid hormones in plasma samples by high performance liquid chromatograph/diode array detector/electrospray ionization mass spectrometer)

  • 곽선영;문명희;표희수
    • 분석과학
    • /
    • 제20권5호
    • /
    • pp.424-433
    • /
    • 2007
  • 혈장시료 중의 갑상선 호르몬을 고체상 추출법을 이용하여 추출한 후 HPLC/DAD/ESI-MS (high-performance liquid chromatograph/diode array detector/electrospray ionization-mass spectrometer)를 사용하여 분석하였다. 7종의 thyroid hormones의 HPLC 분리조건은 Hypersil ODS 컬럼(4.6 mm I.D., 250 mm length, particle size $5{\mu}m$)을 사용하고 ammonium formate buffer와 아세토나이트릴을 이동상으로 하여 기울기 용리한 결과 완전 분리가 가능하였으며, UV spectra 및 질량스펙트럼을 확인할 수 있었다. 고체상추출법에 의한 전처리 최적 조건을 조사한 결과 시료를 pH 3으로 한 후 C18 고체상을 사용하여 4 mL의 메탄올로 용리할 경우 회수율이 74.5-115.7%로 나타났다. HPLC/ESI-MS를 이용하여 20-500 ng/mL범위에서 검량선을 작성한 결과 $r^2$값은 0.9939-0.9978으로 나타났으며 검출한계는 20-50 ng/mL (38.1-162.8 pmol/mL)로 계산되었다. 정상인의 혈장에서 thyroxine의 정량이 가능하였으며 그 결과 50.98-112.97 ng/mL로 검출되었다.

HPLC의 이동상 용매조건에 따른 인삼 Ginsenoside 분석 (Analytical Optimum of Ginsenosides according to the Gradient Elution of Mobile Phase in High Performance Liquid Chromatography)

  • 박지영;원준연;이충열
    • 한국약용작물학회지
    • /
    • 제15권3호
    • /
    • pp.215-219
    • /
    • 2007
  • HPLC에 의한 미량 Ginsenoside의 분석법을 확립하고자 연구를 수행하였던 바, 그 결과를 요약하면 다음과 같다. 인삼 ginsenosid의 분석은 많이 시도되어 왔으나 주요 사포닌 및 미량 사포닌의 분석법이 정립되지 않고 있는 실정인바, 본 연구에서는 이동상 용매의 기울기 용리를 다양하게 변화를 주어 Rb$_1$, Rb$_2$, Rb$_3$, Rc, Rd, Re, Rf Rg$_1$, Rg$_2$, Rg$_3$, Rh$_1$, Rh$_2$의 총 12종의 사포닌을 양호하게 분리하는데 성공하였다. 이동상의 흐름 속도는 1.00ml/min이고 column온도는 35$^{\circ}$C, UV detector의 파장은 203nm로 모두 일정하게 한 결과였으며, 최적의 분석조건은 H$_2$O와 CH$_3$CN의 용매 조성이 82/18, 70/30, 55/45, 50/50으로 각각의 ginsenosides의 안정적인 Area 값을 얻을 수 있었고 재현성을 시도해본 결과, 반복간 편차가 적어 재현성이 매우 양호한 것으로 나타났다.

HPLC-PDA을 이용한 이진탕 중 6종 성분의 동시분석 (Simultaneous Analysis of Six Compounds in Yijin-tang by HPLC-PDA)

  • 김성실;김정훈;신현규;서창섭
    • 대한한의학방제학회지
    • /
    • 제21권1호
    • /
    • pp.71-79
    • /
    • 2013
  • Objectives : Yijin-tang has been used in the treatment of gastrointestinal diseases such as irritable bowel syndrome, gastritis, and gastric ulcer. In this study, a high-performance liquid chromatography (HPLC) method was established for simultaneous analysis of six compounds, liquiritin, glycyrrhizin, hesperidin, 6-gingerol, homogentisic acid, and 3,4-dihydroxybenzaldehyde in Yijin-tang, a traditional Korean herbal medicinal preparation. Methods : A Gemini C18 column was used for the separation of six constituents at $40^{\circ}C$. The mobile phase using gradient elution consist of two solvent systems, 1.0% acetic acid in water (A) and 1.0% acetic acid in acetonitrile (B). The flow-rate was 1.0 mL/min and injection volume was $10{\mu}g$. The detector was a photodiode array (PDA) detector set at 254 nm and 280 nm. Results : The calibration curves of six compounds showed good linearity in various concentration ranges ($R^2{\geq}0.9997$). The limits of detection (LOD) and limits of quantification (LOQ) were 0.028-$0.192{\mu}g/mL$ and 0.093-$0.540{\mu}g/mL$, respectively. The RSD (%) of the intra and inter day validations were 0.03-0.84% and 0.05 -1.00%, respectively. Recovery was 96.14-01.90% and RSD (%) was less than 1.5%. Conclusions : The established simultaneous analysis methods will help management to improve the quality of Yijin-tang.