• 제목/요약/키워드: HPGe Detector

검색결과 102건 처리시간 0.025초

Experimental and Simulated Efficiency of a HPGe Detector in the Energy Range of $0.06{\sim}11$ MeV

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.234-242
    • /
    • 2003
  • The full energy peak efficiency of a hyper pure germanium (HPGe) detector was calibrated in a wide energy range from 0.06 to 11 MeV. Both the experimental technique and the Monte Carlo method were used for the efficiency calibration. The measurement was performed using the standard radioisotopes in the low energy region of $60{\sim}1408$ keV, which was further extended up to 11 MeV by using the $^{14}N(n,r)\;and\;^{35}Cl(n,r)$ reactions. The GEANT Monte Carlo code was used for efficiency calculation. The calculated efficiency had the same dependency on the r-ray energy with the measurement, and the discrepancy between the calculation and the measurement was minimized by fine-tuning of the detector geometry. From the calculated result, the efficiency curve of the HPGe detector was reliably determined particularly in the high energy region above several MeV, where the number of measured efficiency points is relatively small despite the wide energy region. The calculated efficiency agreed with the measurement within about $7\%$. In addition to the efficiency calculation, the origin of the local minimum near 600 keV on the efficiency curve was analyzed as a general characteristics of a HPGe detector.

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

  • Marcel Ohera;Lubomir Gryc;Irena Cespirova;Jan Helebrant;Lukas Skala
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4039-4047
    • /
    • 2023
  • This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special software to control, measure and process the data. The system was calibrated for the local air kerma rates measured on helicopter board and its conversion to the air kerma rates at 1 m above the ground was proposed. Two examples of the air kerma rates measured over the former uranium mining areas are presented and compared with the results of other airborne system on the board. This airborne HPGe system could be also used for measuring the surface activities in a radiation event. The nuclides of 131I, 132Te - 132I, 133I, 134I, 135I, 137Cs, 134Cs, 88Rb and 103Ru were selected from possible nuclear power plant emergency scenarios. The Monte Carlo simulation was used to calculate HPGe detector efficiencies for the flight altitudes from 25 to 300 m for the energies from 300 keV to 3 MeV of the nuclides in question. Also, the detection limits according to the Currie method as well as ISO 11929-2010 for selected nuclides are presented.

고효율 HPGe 검출기의 동시합성효과 보정 연구 (Study on the cascade summing correction for high efficiency HPGe detector)

  • 이모성
    • Journal of Radiation Protection and Research
    • /
    • 제30권3호
    • /
    • pp.107-112
    • /
    • 2005
  • 단일 핵종의 붕괴시 방출된 두 감마선이 함께 검출기에 흡수될 때 cascade summing이 일어난다. 이 효과는 일부 핵종에서 10% 이상의 계통적 오차를 야기한다. 이들 동시합성 효과를 추산하기 위해 검출기 주위에서 측정한 피크-토탈 비를 사용하여 그 효과를 직접 계산하였다. 검출기 주번에서 주어진 에너지에 대한 피크-토탈 비는 일정하지 않을 수 있으며, 따라서 측정된 값의 평균을 사용하여야 한다 산란 물체에 의한 피크-토달 비의 영향에 대한 결과도 함께 포함되어 있다.

Signal Shapes from a Closed-ended Coaxial HPGe Detector

  • Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.451-458
    • /
    • 1997
  • Signal shapes from a closed-ended coaxial HPGe detector are investigated by numerical methods. The detector used in this study has a volume of 72 ㎤ with relative efficiency of 15%. The electric field and potential distributions in the detector are determined by solving the Poisson equation at the depletion and operating bias. Hence the time dependent signal shapes induced on the electrode are obtained from the energy balance consideration and tv solving the equation of motion for the charge carriers. For various initial positions of a charge carrier pair, the collection times of induced charge vary in the range of 70 - 404 nsec.

  • PDF

HPGe 검출기를 사용한 감마분광분석계의 점검선원 개발 (Development of a simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector)

  • 이모성
    • Journal of Radiation Protection and Research
    • /
    • 제38권2호
    • /
    • pp.119-123
    • /
    • 2013
  • HPGe 검출기를 사용하는 감마 분광분석계의 건전성을 점검하기 위한 실험실 선원이 개발되었다. 점검 선원은 0.154 mm 이하의 라듐이 풍부한 토양을 밀봉된 원통형 시료 용기에 담은 것으로, 검출기 교정에 사용할 12 개의 감마선이 방출된다. 점검 선원의 스펙트럼은 1년 동안 1개월 간격으로 측정하였으며, 스펙트럼에 나타난 감마선 피크들의 특성을 조사하였다. 감마 분광분석계가 정상일 때 라듐과 그 붕괴 생성물에서 3% 이상 방출률을 갖는 감마선들의 피크면적과 반치폭은 77 keV 피크를 제외하고는 각각 표준편차 2%와 3% 이내에서 일정하였다. 따라서 점검 선원은 77 keV부터 2202 keV까지 영역에 있는 10개의 피크를 사용하여 분광분석계의 건전성을 점검하는데 충분한 것으로 판단되었다.