• Title/Summary/Keyword: HPGe ${\gamma}$ spectrometer

Search Result 21, Processing Time 0.023 seconds

Uranium Activity Analysis of Soil Sample Using HPGe Gamma Spectrometer (고순도 반도체(HPGe) 감마분광시스템을 이용한 토양 중 우라늄 방사능 분석)

  • Lee, Wan-No;Kim, Hee-Reyoung;Chung, Kun-Ho;Cho, Young-Hyun;Kang, Mun-Ja;Lee, Chang-Woo;Choi, Geun-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.105-110
    • /
    • 2010
  • Using N-type HPGe gamma spectrometer, uranium analysis technique of soil sample is developed where the chemical preprocessing is not a necessity. The results of uranium activities using the method presented in this paper were compared with those results with conventional alpha spectrometer and two results were similar from within uncertainty range. Therefore, this new method will be applied in uranium activity analysis of soil sample.

Performance of a Compton Suppression Spectrometer of the SNU-KAERI PGAA Facility

  • Sun Gwang Min;Park Chang Su;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.347-355
    • /
    • 2003
  • The \gamma-ray spectrometer of the PGAA (Prompt Gamma Activation Analysis) facility constructed at HANARO of the Korea Atomic Energy Research Institute was upgraded to the multi-mode spectrometer including the single mode, the Compton suppression mode and the pair mode. The performance of the spectrometer was tested and summarized. The background count rate and the uncertainty of the detection efficiency were reduced greatly in comparison with those before the new installation.

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

A 235U mass measurement method for UO2 rod assembly based on the n/γ joint measurement system

  • Yang, Jianqing;Zhang, Quanhu;Su, Xianghua;Li, Sufen;Zhuang, Lin;Hou, Suxia;Huo, Yonggang;Zhou, Hao;Liu, Guorong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1036-1042
    • /
    • 2020
  • Fast-Neutron Multiplicity Counter based on Liquid Scintillator Detector can directly measure the fast neutron multiplicity emitted by UO2 rod. HPGe gamma spectrometer; which has superior energy resolution; is routinely used for the gamma energy spectrum measurement. Combing Fast-Neutron Multiplicity Counter and HPGe γ-spectrometer, the n/γ joint measurement system is developed. The fast neutron multiplicity and gamma energy spectrum of UO2 rod assemblies under different conditions are measured by the n/γ joint measurement system. The induced fission rate and the 235U abundance, thereby the 235U mass; can be obtained for UO2 rod assemblies. The 235U mass deviation of the measured value from the reference value is less than 5%. The results show that the n/γ joint measurement system is effective and applicable in the measurement of the 235U mass in samples.

Feasibility about the Direct Measurement of 226Ra Using the Gamma-Ray Spectrometry (감마분광분석을 이용한 226Ra의 직접 측정방법에 대한 적용성 평가)

  • Ji, Young-Yong;Chung, Kun Ho;Lim, Jong-Myoung;Kim, Change-Jong;Jang, Mee;Kang, Mun Ja;Park, Sang Tae;Woo, Zuhee;Koo, Boncheol;Seo, Bokyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.2
    • /
    • pp.97-105
    • /
    • 2014
  • In the case of the direct measurement of $^{226}Ra$ using a HPGe gamma-ray spectrometer, the interference between gammarays with 186.21 keV of $^{226}Ra$ and 185.7 keV of $^{235}U$ should be corrected to calculate the net peak area in the energy spectrum. In general, it is very difficult to conduct peaks stripping with difference of about 0.5 keV, although a HPGe with the superior resolution is applied and the maximum channels is applied to the spectrometer. In this study, several interference correction techniques in the direct measurement were surveyed to evaluate the feasibility for the measurement of $^{226}Ra$ using the gamma-ray spectrometery. Applying the interference corrections to the analysis of raw materials and by-products, the method validation for the direct measurement of $^{226}Ra$ was conducted by evaluating the measurement uncertainty, linearity, and range. As a result, the optimum method of the interference correction was selected by comparing with the indirect measurement of which progenies of $^{226}Ra$, such as $^{214}Pb$ and $^{214}Bi$, were analyzed in the secular equilibrium state.

Study on Thermal Neutron Efficiency for Neutron Induced Prompt Gamma-ray Spectrometer Using Various Reflectors (즉발감마선 계측시스템의 반사체를 이용한 열중성자 효율증대 연구)

  • Park, Y.J.;Song, B.C.;Jee, K.Y.
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.426-429
    • /
    • 2003
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system equipped with a $^{252}Cf$ neutron source and a n-type coaxial HPGe detector was installed for the quantitative analysis of aqueous samples in KAERI, Korea. Since the thermal neutron flux for the $^{252}Cf$ neutron source is relatively low compared to that for the reactor, the use of a thermal neutron reflector in the NIPS system may lead to improved results. The enhancement by using various reflectors was carried out by comparing the Cl peak with or without a cadmium plate between sample and the $^{252}Cf$ source. The use of pyrolitic graphite as a reflector provided a good result.

Study on the Measurement of Radon concentrations in soil samples using γ-spectrometer (γ-spectrometer를 이용한 토양시료의 라돈농도 측정법에 관한 연구)

  • Kang, Sunga;Lee, Sangsoo;Choi, Guirack;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.31-36
    • /
    • 2013
  • The radioactive gas radon ($^{222}Rn$), which is generated from the decay process of uranium ($^{238}U$) originating from the soil of more than 85 percent higher the porosity of the soil, the soil can radiate out the possibility that many isotopes. In order to protect the human body from radon, above all, the development of accurate measurement techniques to formulate appropriate measures should be followed. This study Gamma-ray spectrometry using a high purity germanium (HPGe) detector, if you want to measure radon unstable the nature radiation of the background problems can be reduced, radium and radon daughter nuclides after radioactive equilibrium leads to Radon concentration was measured, the soil samples from the Gamma-ray emitting nuclides, and the energy spectrum is analyzed.

Characterization and experimental investigation for gamma-ray shielding competence of basalt-doped polyethylene nanocomposites

  • I.A. El-Mesady;F.I. El-Agawany;H. El-Samman;Y.S. Rammah;A. Hussein;R.A. Elsad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.477-484
    • /
    • 2024
  • Experimental investigations on gamma - rays attenuation parameters and dielectric spectroscopic properties were done on a polymeric mixture with chemical composition (100-x) polyethylene + x basalt, where x = 0, 1, 3, 5, 10, and 20 wt%. Using the melting blending technique,six nanocomposite polymeric samples were prepared. The linear attenuation coefficient µ of each prepared set of samples was measured using a gamma-ray spectrometer including High Purity Germanium detector (HPGe) at energies 662.5, 1173.24, and 1332.51 keV. Based on the measured values of (µ) and sample density, the other effective shielding parameters were calculated. The values of µ showed an increase with increasing the dopant ratios from 0.0 up to 20.0 wt%. In addition, the µ values decreased with the photon's energy. The µ values were found 0.0847 up to 0.1175 cm-1, 0.0571 up to 0.0855 cm-1, and 0.0543 up to 0.075 cm-1 at 662.5, 1173.24, and 1332.51 keV. for B0 up to B20, respectively. The ATR spectroscopy was done on the prepared samples, and a good evidence of adding the filler to the pure polyethylene (HDPE) was obtained. Besides, an enhancement in dielectric constant by insertion of basalt NPs also recorded and can be attributed to the large dielectric constant of basalt compared to pure HDPE.

Separation and Recovery for the Analysis of Radioiodine in RI Wastes (RI 폐기물 내 방사성요오드 분석을 위한 분리 및 회수)

  • Kang, Sang-Hoon;Han, Sun-Ho;Lee, Heung-N.;Jee, Kwang-Yong;Lee, In-Koo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.4
    • /
    • pp.267-272
    • /
    • 2007
  • Various kinds of RI wastes are discharged from licensed organizations of radioisotopes les such as hospitals and clinic organizations, educational organizations, research institutions, and public organizations. Radioiodines such as $^{125}I\;and\;^{131}I$ are radioisotopes mainly used in nuclear medicine and industry. A method for the determination of radioiodines in RI wastes has been applied to measure low level activity using acid decomposition method and HPGe gamma ray spectrometer. Prior to analysis of real samples, $^{131}I$ reference solution and 10 g of yellow tissue paper was added to flask in mantle and was heated in 100 mL of 0.4 N $K_2Cr_2O_7$ and 100 mL of 9 M $H_2SO_4$, and then distilled after adding 10 mL of 30% $H_2PO_3$ and 1 mL of 30% $H_2O_2$. The condensed iodine by circulator was extracted into $CCl_4$, then back-extracted into the aqueous phase with 10 mL of 5% $K_2SO_2$ solution. Finally, $^{131}I$ was measured at 364.48 keV using HPGe gamma ray spectrometer after precipitation and filtration. Chemical yield of three steps such as acid decomposition process, chemical separation process, and precipitation and filtration process was more han 94% respectively, MDA(Minimum Detectable Activity) of $^{131}I$ at this analytical condition was 0.6 Bq/g.

  • PDF