• Title/Summary/Keyword: HP

Search Result 1,872, Processing Time 0.031 seconds

Clothing Values, Lifestyles, and Purchasing Situations of Purchaser groups classified by Purchasing Price for preschool children's Wear (유아복(乳兒服) 구매비(購買費)에 따른 유아복(乳兒服) 구매자(購買者)의 의복(衣服)에 대(對)한 가치관(價値觀), 라이프스타일 및 구매실태(購買實態))

  • Shin, Hye-Won;Ha, O-Sun;Rhee, Jung-Uk;Kim, Hee-Ra;Kim, Tae-In
    • Journal of Fashion Business
    • /
    • v.9 no.4
    • /
    • pp.113-126
    • /
    • 2005
  • The purposes of this study were to classify purchaser into three groups by purchasing price for preschool children's wear and to identify the differences of clothing values, lifestyles, considerations in purchasing preschool children's wears, and purchasing places among the classified three groups. One hundred forty people living in Seoul with children aging between 3 and 7 were surveyed for this study. Cluster analysis, frequency analysis, chi-square analysis, ANOVA, and scheffe test were used to analyze the data. The findings of this study were as follows; 1) Purchaser were classified into three groups, namely the group of high purchasing price(HP), the group of medium purchasing price(MP), and the low purchasing price(LP). The HP had more monthly average income than the LP. 2) The HP showed high concerns in aesthetic and social clothing values, the MP considered social clothing value more important, while the LP showed high concern in economic clothing value. 3) Regarding the differences in lifestyles, the HP was more fashion-oriented and leisure-oriented, the MP was fashion-oriented, while the LP was economy-oriented. 4) When purchasing preschool children's wear, the HP showed high concerns in design and brand, the MP in activity, laundry-and-care, and brand, and the LP in activity, laundry-and-care, and price. The HP mainly purchased preschool children's wears in department store and imported goods store, the MP in department store, traditional market, and discount store, and the LP in discount store.

Tooth bleaching effect by light activation on the tooth surface and intra-pulpal temperature: an in vitro study (광활성 유무가 치아미백과 치아표면 및 치수 내 온도에 미치는 영향)

  • Shim, Youn-Soo;Woo, Hee-Sun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.4
    • /
    • pp.585-591
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate of the color change, tooth surface and intra-pulpal temperature of tooth bleaching by light activation Methods : Forty-eight extracted bovine teeth were immersed into a tea solution for 24 hours. The specimens were randomly divided into four groups(n=15):(G1) 15% HP + without light activation, (G2) 15% HP + light activation, (G3) 25% HP + without light activation, (G4) 25% HP + light activation. All specimens were bleached for 15 minutes three times. The spectrophotometer (CM-2600d, Konica Minolta, Osaka, Japan) was used including before bleaching, immediately after bleaching, 1 week, 1 and 3 months after the end of bleaching. The temperature rise were measured in the pulpal chamber and tooth surface with a digital thermocouple thermometer(Termopar Digital Multimeter, Tektronix DMM916, USA). Between the tested time points, the specimens were stored in distilled water. The data were analyzed by ANOVA, t-test and Tukey's post hoc test set at 0.05. Results : There was no significant color change by the use of light after the bleaching treatment(p>0.05). The dental bleaching treatments of teeth with 15% HP and 25% HP did not seem to be more effective when light source was used. There was no difference in color stability between groups within three month(p>0.05). There was an increase in tooth surface and pulp temperature, but it was not sufficient to cause damage to the pulp. Conclusions :The use of light activation has no obvious effective impact on the tooth bleaching effect.

Thixoforming Characteristics of Metal Matrix Composites (Phase identification of $SiC_p/AZ91HP$ Mg composite) (금속기 복합재료의 틱소포밍 특성 ($SiC_p/AZ91HP$ Mg 복합재료의 상분석을 중심으로))

  • Lee, Jung-Il;Kim, Young-Jig
    • Applied Microscopy
    • /
    • v.29 no.3
    • /
    • pp.281-289
    • /
    • 1999
  • The stirred and thixoformed $SiC_p/AZ91HP$ Mg composites are studied on the basis of microstructural analysis using transmission electron microscopy (TEM). The products of interfacial reaction are identified as $Mg_2Si$, MgO and $Mg_{17}Al_{12}$ phases and the crystallized phases are found to be orthorhmbic $Al_6Mn$ and decagonal T phases. It is shown that $Mg_2Si$ and $Mg_{17}Al_{12}$ phases are found at the surface of $SiC_p$ and $Al_6Mn$ is found near interface and crystallized on the matrix. Phase identification is carried out by crystallographic work based on primitive cell volume, zero order Laue zone (ZOLZ) patterns and single convergent beam electron diffraction (CBED) patterns containing higher order Laue zone ring from a nanosized region.

  • PDF

Inactivation Efficiency of Escherichia coli and Listeria monocytogenes in Ground Pork by Combination of Natural Food Ingredients and High Pressure Processing

  • Jung, Samooel;Yun, Hye-Jeong;Kim, Hyun-Joo;Ham, Jun-Sang;Kim, Il-Suk;Lee, Moo-Ha;Jo, Cheorun
    • Food Science of Animal Resources
    • /
    • v.32 no.1
    • /
    • pp.1-5
    • /
    • 2012
  • The objective of this study was to examine the effects of a combined treatment regarding antimicrobial food ingredients and high pressure processing (HP) on the inactivation efficiency of Escherichia coli and Listeria monocytogenes inoculated into ground pork. Ethanol extracted from garlic, leeks, onions, and ginger powder was prepared. Half of the prepared powder was irradiated at 5 kGy to see the effect of pasteurization before addition. The prepared food ingredients were added into radiation-sterilized ground pork (1%, w/w), and inoculated with E. coli and L. monocytogenes. The samples were vacuum-packed and applied with HP at 0.1 (control), 300, 450, and 600 MPa. Microbial log reduction increased with the increase of pressure up to 600 MPa. With minor exceptions, overall efficiency of HP treatment with regards to inactivation of pathogens increased. Inoculated microorganisms showed approximately 7-8 Log reductions by 600 MPa, except for L. monocytogenes treated with garlic (5.7 Log reductions). The E. coli reduction in ground pork mixed with ethanol extracted garlic showed the highest efficiency (1.86) compared to leeks (1.25-1.31), onions (1.17-1.44), and ginger (1.50-1.82) when treated at an HP of 450 MPa. There was no evidence for the advantage of pasteurization concerning the food ingredients before addition of antimicrobial food ingredients and HP. Results demonstrate that the combination of antimicrobial food ingredients and HP treatment may help improve the efficiency of sterilization in meat systems.

Clinical and Radiological Outcomes of Acute Acromioclavicular Joint Dislocation: Comparison of Hook Plate Fixation with Single Tight Rope Technique

  • Lee, Sung Hyun;Kim, Jeong Woo;Kook, Seng Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.153-161
    • /
    • 2017
  • Background: This study was conducted to compare the clinical and radiological outcomes of the locking hook plate fixation (HP) technique and the single tight rope (TR) technique applied for acute high-grade acromioclavicular (AC) joint separations. Methods: Between 2009 and 2014, 135 consecutive patients with acute AC joint separation Rockwood types III, IV, and V were subjected to surgical reconstruction. One hundred fourteen patients (84.4%) were available for retrospective evaluation. Of them, 62 and 52 were treated using the single TR group and clavicular HP group techniques, respectively. The visual analogue scale, Constant, American Shoulder and Elbow Surgeons (ASES), and Taft scores were used for clinical assessment. Postoperative shoulder range of motion was also assessed. An anteroposterior radiograph of the coracoclavicular distance (CCD) was obtained to evaluate the radiographic signs of recurrence. Results: The TR group patients had better Constant, ASES, and Taft scores than the HP group patients. The loss of reduction in terms of the CCD did not differ between groups. Subacromial osteolysis was observed in 34.6% of the cases in the HP group. However, there were no significant differences in the clinical outcomes between the patients with and without osteolysis in the HP group. Subcoracoid osteolysis, drill tunnel widening, and metal displacement were observed in 3.2%, 22.6%, and 4.8% of the cases in the TR group, respectively. Conclusions: The single TR technique was relatively more effective at treating acute high-grade AC joint injuries than the HP fixation technique (level of evidence: therapeutic; retrospective comparative study, Level III).

Utilization of Soybean for Swine Diets (양돈 사료에 있어 대두의 이용)

  • Yoo, Jong-Sang;Kim, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.156-166
    • /
    • 2007
  • Soybean meal was widely used as a protein source in pig feedstuff because it has a good amino acid balance compared with other vegetable sources. However, soybeans contain trypsin inhibitors and other antinutritional factors which can lead to lower the digestibility of amino acid, and consequently reduce the growth performance. Heat treatment of soybeans is helpful shown to decrease the antinutritional factors and elicit an improved growth performance. Additionally, microbial processe using(HP 100, HP 200 and HP 300), and non-protein constituent removal are suggested to improve the growth performance and nutrient digestibility. Inadequate heat treatment of soybeans gives no damage to adult pig, but it has been shown to decrease nutrient digestibility in young pig. So, soy protein concentrate (SPC) and Isolated soy protein(ISP) were more widely used for nursery pigs than growing and finishing pigs, since SPC and ISP have similar characteristics as milk product.

  • PDF

A Study on the Analysis of Radiation Dose for Thermoplastic Material and 3D Print Filament Materials (열가소성 플라스틱 재질과 3D 프린트 필라멘트 재질에 대한 방사선량 분석에 관한 연구)

  • Lee, Dong-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.181-189
    • /
    • 2021
  • This study is a prior research to manufacture a thermoplastic mask, which is a fixture used in radiation therapy, by 3D printing. It proceeded to analyze the filament material that can replace the thermoplastic. Among the commercially available filament materials, a material having similar characteristics to that of a thermoplastic mask was selected and the radiation dose was compared and analyzed. The experiment used Monte Carlo simulation. The shape in which the mask fixed the head was simulated for the ICRU sphere. The photon fluence was calculated at the skin Hp (0.07), the lens Hp (3), and the whole body Hp (10) by applying a thermoplastic plastic material and a filament material. As a result, when looking at the relative dose based on the thermoplastic plastic material, the difference was approximated within 4%. The material showing the most similar dose was PA-nylon. In selecting an appropriate filament material, it should be selected by comprehensively considering various conditions such as economical efficiency and radiation effects. It is thought that the results of this study can be used as basic data.

A High-Performance ECC Processor Supporting Multiple Field Sizes over GF(p) (GF(p) 상의 다중 체 크기를 지원하는 고성능 ECC 프로세서)

  • Choe, Jun-Yeong;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.3
    • /
    • pp.419-426
    • /
    • 2021
  • A high-performance elliptic curve cryptography processor (HP-ECCP) was designed to support five field sizes of 192, 224, 256, 384 and 521 bits over GF(p) defined in NIST FIPS 186-2, and it provides eight modes of arithmetic operations including ECPSM, ECPA, ECPD, MA, MS, MM, MI and MD. In order to make the HP-ECCP resistant to side-channel attacks, a modified left-to-right binary algorithm was used, in which point addition and point doubling operations are uniformly performed regardless of the Hamming weight of private key used for ECPSM. In addition, Karatsuba-Ofman multiplication algorithm (KOMA), Lazy reduction and Nikhilam division algorithms were adopted for designing high-performance modular multiplier that is the core arithmetic block for elliptic curve point operations. The HP-ECCP synthesized using a 180-nm CMOS cell library occupied 620,846 gate equivalents with a clock frequency of 67 MHz, and it was evaluated that an ECPSM with a field size of 256 bits can be computed 2,200 times per second.

Role of Krebs von den Lungen-6 (KL-6) in Assessing Hypersensitivity Pneumonitis

  • Mostafa, Amira Ismail;Salem, Ayman Elsayed;Ahmed, Heba Allah Moussa;Bayoumi, Aml Ibrahim;Halim, Radwa M. Abdel;Samie, Rasha M. Abdel
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.3
    • /
    • pp.200-208
    • /
    • 2021
  • Background: Hypersensitivity pneumonitis (HP) is an increasingly recognized form of diffuse parenchymal lung disease. Krebs von den Lungen-6 (KL-6) is now classified as a human MUC1 mucin protein, and regenerating type II pneumocytes are the primary cellular source of KL-6/MUC1 in the affected lungs of patients with interstitial lung diseases (ILD). Serum KL-6/MUC1 levels have been demonstrated to be useful for the evaluation of various ILD. To determine the role of circulating KL-6 in evaluating the disease activity and management of HP. Methods: An observational cross-sectional study was conducted on 51 patients with HP and 20 healthy controls. Serum KL-6 levels were measured in both groups. Patients were further assessed based on chest high-resolution computed tomography (HRCT), pulmonary function test, 6-minute walk test, echocardiography, bronchioalveolar lavage, and/or transbronchial biopsy. Patients were divided into the fibrotic and non-fibrotic groups according to the HRCT findings. Results: The median serum KL-6 levels were significantly higher in HP patients as compared to the control group. The median serum KL-6 levels were found to be higher in the non-fibrotic HP group (1,900 IU/mL) as compared to the fibrotic group (1,200 IU/mL). There was a significant inverse correlation between serum KL-6 serum level and the dose of steroids as well as the duration of steroid therapy. Conclusion: The presence of higher KL-6 levels in the non-fibrotic HP group implies its enhanced production by regenerating pneumocytes in response to alveolar injury. The significant association between serum KL-6 levels and the dose and the duration of steroid therapy emphasizes the significant role of steroids in the stabilization of the disease.

Comparative analysis of bond strength to root dentin and compression of bioceramic cements used in regenerative endodontic procedures

  • Maykely Naara Morais Rodrigues;Kely Firmino Bruno;Ana Helena Goncalves de Alencar;Julyana Dumas Santos Silva;Patricia Correia de Siqueira;Daniel de Almeida Decurcio;Carlos Estrela
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.59.1-59.14
    • /
    • 2021
  • Objectives: This study compared the Biodentine, MTA Repair HP, and Bio-C Repair bioceramics in terms of bond strength to dentin, failure mode, and compression. Materials and Methods: Fifty-four slices obtained from the cervical third of 18 single-rooted human mandibular premolars were randomly distributed (n = 18). After insertion of the bioceramic materials, the push-out test was performed. The failure mode was analyzed using stereomicroscopy. Another set of cylindrically-shaped bioceramic samples (n = 10) was prepared for compressive strength testing. The normality of data distribution was analyzed using the Shapiro-Wilk test. The Kruskal-Wallis and Friedman tests were used for the push-out test data, while compressive strength was analyzed with analysis of variance and the Tukey test, considering a significance level of 0.05. Results: Biodentine presented a higher median bond strength value (14.79 MPa) than MTA Repair HP (8.84 MPa) and Bio-C Repair (3.48 MPa), with a significant difference only between Biodentine and Bio-C Repair. In the Biodentine group, the most frequent failure mode was mixed (61%), while in the MTA Repair HP and Bio-C Repair groups, it was adhesive (94% and 72%, respectively). Biodentine showed greater resistance to compression (29.59 ± 8.47 MPa) than MTA Repair HP (18.68 ± 7.40 MPa) and Bio-C Repair (19.96 ± 3.96 MPa) (p < 0.05). Conclusions: Biodentine showed greater compressive strength than MTA Repair HP and Bio-C Repair, and greater bond strength than Bio-C Repair. The most frequent failure mode of Biodentine was mixed, while that of MTA Repair HP and Bio-C Repair was adhesive.