• 제목/요약/키워드: HIP treatment

검색결과 390건 처리시간 0.031초

개에서 내측슬개골 탈구 등급에 따른 고관절 이상과의 상관관계에 대한 방사선학적 평가 (Radiographic Evaluation of Hip Conformation in the Dogs with Medial Patella Luxation)

  • 이기자;박은정;권영항;최호정;이영원
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.278-282
    • /
    • 2013
  • This study was performed in 41 dogs with unilateral or bilateral medial patella luxation (MPL) and/or cranial cruciate ligament rupture (CCLR). These dogs were classified into 4 groups according to MPL grading system. Radiographic evaluation was performed for pelvis and stifle joint in the dogs. Norberg, inclination, quadriceps and femoral varus angle were measured and analyzed with MPL grading and the existence of cranial cruciate ligament rupture. The Norberg and inclination angle showed no differences between 4 grading groups and between CCLR and no CCLR groups. However, quadriceps and femoral varus angle were statistically different between grade 1, 2 and grade 3, 4 groups. They also have shown the statistical difference between CCLR and no CCLR group. Further studies for how these parameters affect the prognosis and the results of surgical treatment of MPL should be needed.

Effect of pressure and temperature on bulk micro defect and denuded zone in nitrogen ambient furnace

  • Choi, Young-Kyu;Jeong, Se-Young;Sim, Bok-Cheol
    • 한국결정성장학회지
    • /
    • 제26권3호
    • /
    • pp.121-125
    • /
    • 2016
  • The effect of temperature and pressure in the nitrogen ambient furnace on bulk micro defect (BMD) and denuded zone (Dz) is experimentally investigated. It is found that as pressure increases, Dz depth increases with a small decrease of BMD density in the range of temperature, $100{\sim}300^{\circ}C$. BMD density with hot isostatic pressure treatment (HIP) at temperature of $850^{\circ}C$ is higher than that without HIP while Dz depth is lower due to much higher BMD density. As the pressure increases, BMD density is increased and saturated to a critical value, and Dz depth increases even if BMD density is saturated. The concentration of nitrogen increases near the surface with increasing pressure, and the peak of the concentration moves closer to the surface. The nitrogen is gathered near the surface, and does not become in-diffusion to the bulk of the wafer. The silicon nitride layer near the surface prevents to inject the additional nitrogen into the bulk of the wafer across the layer. The nitrogen does not affect the formation of BMD. On the other hand, the oxygen is moved into the bulk of the wafer by increasing pressure. Dz depth from the surface is extended into the bulk because the nuclei of BMD move into the bulk of the wafer.

신장 암의 비구주위 단독 전이 환자에서 종양절제 및 재건술 - 증례 보고 - (Tumor Resection and Reconstruction in Periacetabular Single Metastases of Renal Cell Carcinoma - A Case Report -)

  • 신덕섭;한동성
    • 대한골관절종양학회지
    • /
    • 제13권2호
    • /
    • pp.113-118
    • /
    • 2007
  • 골반 골에 생기는 종양은 복잡한 해부학적 구조와 체부 깊숙이 위치하는 특성으로 인하여, 상당히 커진 후에야 발견되는 경우가 많아서 진단이 늦어지고, 수술이 어려워지는 경우가 많이 있다. 특히 비구 주위에 발생한 종양은 종양의 제거 후에 고관절의 기능을 유지 할 수 있는 재건술의 방법이 극히 제한되어 있고, 수술도 어려우며, 재건술의 예후 또한 예측하기 어렵다. 저자는 신장암이 골반 골 비구 주위로 단독 전이 된 환자의 광범위 종양절제 후 저온 가열 처리한 자가골 과 인공고관절로 재건 한 증례를 보고한다.

  • PDF

노년 남성의 하반신 체형 유형화에 관한 연구 (Classification of the Lower Half of the Body by the Somatotypes of Elderly Men)

  • 석혜정;임남영
    • 복식
    • /
    • 제59권8호
    • /
    • pp.123-131
    • /
    • 2009
  • This study aims at presenting the basic data related to the somatotype of elderly men at the point of Korea's entering into an aging society. Efforts were made to classify the lower-half somatotype of elderly men, with the application of the measurements of 261 elderly men of 60 years of age and over up to 70, which were available from the physique measurement survey project for Koreans. The number of analysis items was 31. The statistical treatment was made through SPSS win 12.0 program, and the analytical methods used were the basic statistics, factor analysis, and cluster analysis. The findings are as follows: Elderly men experienced the decreases in height and weight, in comparison with middle-aged ones, while they showed a flat shape at trunk, with more protruded waist and abdomen and with flat buttock. The analysis of the constituting factors for the lower-half body of elderly men resulted in the 6 items. The elements constituting the lower-half body of elderly men included the shape from waist to hip, the spread of hip and height of knee, the shape of leg, thigh size, the length of leg, and the volume of abdominal. The total accountability was 81.59 %. The cluster analysis for lower-half somatotype of elderly men resulted in the classification of three types. The above findings are intended to assist the designing of ready-made slacks with a high level of fitness for elderly men.

Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System

  • Youngho Cho;Jae-uk Shin;Sangwoo Kim
    • Hip & pelvis
    • /
    • 제35권1호
    • /
    • pp.47-53
    • /
    • 2023
  • Purpose: The purpose of this study is to compare the radiological results of fixation using the femoral neck system (FNS) and cannulated screw (CS) for treatment of femoral neck fractures. Materials and Methods: A retrospective study of patients with femoral neck fractures who underwent internal fixation and had follow-up of more than six months from 2010 to 2020 was conducted. A total of 87 patients were enrolled in the study. The FNS group included 20 patients and the CS group included 67 patients. Classification of fractures was performed according to Garden and Pauwels classification. Operation time, intraoperative blood loss, sliding distance of the implant, lateral soft tissue irritation caused by implants, and complications were evaluated. Results: The mean operation time was 40.30 minutes in the FNS group and 46.84 minutes in the CS group. The mean intraoperative bleeding volume was 51.25 mL in the FNS group and 72.16 mL in the CS group. Bone union was achieved in 18 patients in the FNS group (90.0%) and in 61 patients in the CS group (91.0%). The mean sliding distance of the implant was 4.06 mm in the FNS group and 3.92 mm in the CS group. No patients in the FNS group and 12 patients in the CS group complained of soft tissue irritation. Conclusion: A shorter operative time, less intraoperative bleeding, and less irritation of soft tissue were observed in the FNS group. FNS could be an alternative to CS for fixation of femoral neck fractures.

SLM 방식으로 적층 제조된 Ti-6Al-4V 합금의 HIP 처리에 따른 준정적 및 동적 기계적 특성 변화 (Influence of Hot Isostatic Press on Quasi-static and Dynamic Mechanical Properties of SLM-printed Ti-6Al-4V Alloy)

  • 장지훈;최영신;김형균;이동근
    • 열처리공학회지
    • /
    • 제33권3호
    • /
    • pp.99-106
    • /
    • 2020
  • Selective laser melting (SLM) is an additive manufacturing process by melting metallic powders and stacking into layers, and can product complex shapes or near-net-shape (NNS) that are difficult to product by conventional processes. Also, SLM process is able to raise the efficiency of production by creating a streamlined manufacturing process. For manufacturing in SLM process using Ti-6Al-4V powder, analysis of microstructural evolution and evaluation of mechanical properties are essential because of rapid melting and solidification process of powders according to high laser power and rapid scan speed. In addition, it requires a post-processing because the soundness and mechanical properties are degraded by defects such as pore, un-melted powder, lack-of-fusion, etc. In this study, hot isostatic press (HIP) was conducted as a post-processing on SLM-printed Ti-6Al-4V alloy. Microstructure of post-processed Ti-6Al-4V alloy was compared to as-built Ti-6Al-4V, and the evolution of quasi-static (Vickers hardness, room temperature tensile characteristic) and dynamic (high-cycle fatigue characteristic) mechanical properties were analyzed.

고관절 전치환술 환자의 Critical pathway적용효과 (Effects of Critical Pathway(CP) on the patients with Primary Total hip replacement(THR))

  • 이미경;도복늠
    • 간호행정학회지
    • /
    • 제8권2호
    • /
    • pp.295-308
    • /
    • 2002
  • Purpose: The purpose of this quasi-experimental research is to develop the CP for primary THR patients and verify its effectiveness. Method: The CP is designed for both patients and medical employees to meet the 14-day-long hospitalization with an expert and clinical validity test, and the standardized orders are also created. 21 eligible subjects for the control group(with common care plan) and 27 subjects for the experimental group(with CP service) were assigned. Data were collected from questionnaires to evaluate patients' satisfaction level of nursing care and CP, investigation of physical complications, inspection of LOS(length of hospital stay) and hospital charges from April 2000 to February 2001 at K-hospital in Daegu. The collected data were analyzed by using the SAS program. Results: After implementation of CP, there was a statistically significant reduction in mean length of stay. The hospital charges have no considerable difference between two groups. Frequency of physical complications is reduced considerably. The experimental group scored much higher than the control group on the satisfaction level toward nursing care. And in the analysis of CP satisfaction questionnaires, many subjects have high satisfaction in items of 'I see the treatment process and hospital life', 'I feel that I am participating in my treatment process with health care staff'. The analysis of variances which cause a prolonged LOS supports that it's necessary to strengthen an evaluation of pre-operative outpatients' condition and link the home nursing care system in discharge for more shortening of LOS. Conclusion: The above results show that CP can have a positive impact on satisfaction level of inpatients with primary THR and the hospital.

  • PDF

외상성 두부 손상에 의한 수두증의 Vojta치료 증례 (The Report of Vojta Therapy in Hydrocephalus on Traumatic Brain Injury)

  • 이근희;구봉오;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제14권1호
    • /
    • pp.125-130
    • /
    • 2002
  • This study was applied using vojta therapy in the patient with hydrocephalus occurred by on traumatic brain injury. Vojta treatment was a recently developed of the brain damage patient treatment which can be applied eariler than the other traditional methods. The results were as follows. 1. Hip joint flexion contracture from $100^{\circ}$ to $15^{\circ}$ was improved on prone position. 2. Left convexity curve on thracolumbar region due to functional scoliosis the normal aligment. 3. The thumb finger was changed from thumb-in to thumb-out. 4. Right tilted pelvis on prone position became the normal symmetry

  • PDF

BIOCOMPATIBISITY OF ION BEAM PROCESSED FILMS DEPOSITED ON SURGICAL TI-6AI-4V

  • Lee, I-S;Song and I-j Yu
    • 한국진공학회지
    • /
    • 제6권S1호
    • /
    • pp.16-22
    • /
    • 1997
  • ion beam processing of materials for medical application has gained increasing interest in the last decade and the implantation of nitrogen into TI-6AI-4V to improve corrosive-wear performance is currently used for processing of total hip and knee joints. Oxides and nitrides of Ti, Zr, Al, Cr were deposited on TI-6AI-4V substrates by DC magnetron sputtering dual ion beam sputtering and ion beam assisted deposition. The cytotoxicity of these films were investigated by MTT method and showed comparable to untreated TI-6AI-4V Plasm-sprayed hydroxyapatite(HAp) coatings showed excellent cytotoxicity regardless of heat treatment. intermediate layer coatings of nitrides and oxides increased the bond strength of HAp to substrate by intrdducing chemical bond at interface. Heat treatment of HAp coatings also improved the chemical bond at interfaces and increased the bond strength of untreated TI-6AI-4V to 16.4 kg/$\textrm{cm}^2$ but still lower than 33.1 kg./$\textrm{cm}^2$ of ir oxide as a imtermediate layer caoting.

  • PDF

무릎관절 재활 운동기기의 운동범위 분석 (Analysis of Range-of-Motion in Continuous Passive Motion Rehabilitation)

  • 박원만;김윤혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1515-1517
    • /
    • 2008
  • The purposes of this study were to measure the ranges of motion in knee joint and during continuous passive motion(CPM) treatment and to computationally calculate joint angles at the knee joint dependent on the CPM machine design and its application. Four CPM machines and eleven candidates were recruited for this study. Experimental and numerical studies have been peformed to calculate the range-of-motion of CPM machines. From the experimental measurements, the average range of motions at the knee joint for the CPM machine #1, #2, #3, and #4 were lower than the manufactures suggested values due to improper alignments of the hip and knee joints to the CPM machines. Different design of CPM machine generated different outcomes of the ROM at the knee joints during CPM. The experiments and kinematic simulation in this study could be used to provide useful guidance in the treatment of CPM after joint surgery.

  • PDF