Evaluation of Acoustic, Thermal, and Morphological Properties in the Egg White Phantom

  • Kim, Mi-Seon;Kim, Ju-Young;Moon, Dong-Jun;Noh, Si-Cheol;Choi, Heung-Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권1호
    • /
    • pp.7-15
    • /
    • 2015
  • The egg white phantom is a thermal lesion visualization phantom able to illustrate a thermal lesion. It is often used to evaluate the performance of HIFU and is less expensive than the BSA phantom. This study determined the optimal phantom composition for evaluated therapeutic ultrasound machines by varying the egg white concentration in the egg white phantom and demonstrated its utility as a therapeutic ultrasound phantom. The egg white phantom at varying egg white concentrations (10-40% in 10% intervals) was fabricated, and its thermal properties and acoustic properties were assessed. In addition, the size and shape of the formed lesion were compared between the egg white phantom and bovine liver tissue according to the electrical power. The results showed that 30% egg white phantom was optimal for the performance evaluation due to its thermal and acoustic properties. The generated thermal lesions formed sequentially as a cigar, ellipse, tadpole, and cone shapes according to the electrical power; a similar tendency was observed in the liver tissue. Hence, we conclude that the egg white phantom will prove useful in quantitatively evaluating the thermal effects of therapeutic ultrasound.

초음파 치료의 효율성 향상을 위한 초음파 온열 시뮬레이터 개발 (The Development of Ultrasonic Hyperthermia Simulator to Improve the Efficiency of Ultrasonic Therapy)

  • 유우진;노시철;정동환;박재현;최민주;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권5호
    • /
    • pp.418-427
    • /
    • 2009
  • As many people are westernizing their life style and food consumption habits, a number of patients who have malignant tumors which grow very rapidly and hazardously destroy the human body are increasing. Ultrasonic hyperthermia is not only one of the tumor treatment methods which employs the non-radioactive ultrasonic waves to increase the temperature at the tumor region up to $40\sim45^{\circ}C$ to destroy and suppress tumor cells but also has been proved by many studies. Due to the rapid development of High Intensity Focused Ultrasound(HIFU), the ultrasound hyperthemia extensively boosts its applications in clinical field. For those reasons, Computed simulation factor should be needed before inspection to patients. To prove efficiency of ultrasonic hyperthermia, precise acoustic field measurement considering tissue characteristics and a heating experiment with tissue mimicking material phantom were conducted for effectiveness of simulation program. Finally, in this study, the computer simulation program verified the anticipated temperature effects induced by ultrasound hyperthermia. In the near future, it is hoped that this simulation program could be utilized to improve the efficiency of ultrasound hyperthermia.

Effect of Mn on Dielectric and Piezoelectric Properties of 71PMN-29PT [71Pb(Mg1/3Nb2/3)O3-29PbTiO3] Single Crystals and Polycrystalline Ceramics

  • Oh, Hyun-Taek;Joo, Hyun-Jae;Kim, Moon-Chan;Lee, Ho-Yong
    • 한국세라믹학회지
    • /
    • 제55권2호
    • /
    • pp.166-173
    • /
    • 2018
  • In order to investigate the effect of Mn on the dielectric and piezoelectric properties of PMN-PT [$Pb(Mg_{1/3}Nb_{2/3})O_3-PbTiO_3$], four different types of 71PMN-29PT samples were prepared using the solid-state single crystal growth (SSCG) method: (1) Undoped single crystals, (2) undoped polycrystalline ceramics, (3) Mn-doped single crystals, and (4) Mn-doped polycrystalline ceramics. In the case of single crystals, the addition of 0.5 mol% Mn to PMN-PT decreased the dielectric constant ($K_3{^T}$), piezoelectric charge constant ($d_{33}$), and dielectric loss (tan ${\delta}$) by about 50%, but increased the coercive electric field ($E_C$) by 50% and the electromechanical quality factor ($Q_m$) by 500%, respectively. The addition of Mn to PMN-PT induced an internal bias electric field ($E_I$) and thus specimens changed from piezoelectrically soft-type to piezoelectrically hard-type. This Mn effect was more significant in single crystals than in ceramics. These results demonstrate that Mn-doped 71PMN-29PT single crystals, because they are piezoelectrically hard and simultaneously have high piezoelectric and electromechanical properties, have great potential for application in fields of SONAR transducers, high intensity focused ultrasound (HIFU), and ultrasonic motors.

Mn-Modified PMN-PZT [Pb(Mg1/3Nb2/3)O3-Pb(Zr,Ti)O3] Single Crystals for High Power Piezoelectric Transducers

  • Oh, Hyun-Taek;Lee, Jong-Yeb;Lee, Ho-Yong
    • 한국세라믹학회지
    • /
    • 제54권2호
    • /
    • pp.150-157
    • /
    • 2017
  • Three types of piezoelectric single crystals [PMN-PT (Generation I $[Pb(Mg_{1/3}Nb_{2/3})O_3-PbTiO_3]$), PMN-PZT (Generation II $[Pb(Mg_{1/3}Nb_{2/3})O_3-Pb(Zr,Ti)O_3]$), PMN-PZT-Mn (Generation III)] were grown by the solid-state single crystal growth (SSCG) method, and their dielectric and piezoelectric properties were measured and compared. Compared to (001) PMN-PT and PMN-PZT single crystals, the (001) PMN-PZT-Mn single crystals exhibited a higher transition temperature between the rhombohedral and tetragonal phases ($T_{RT}=144^{\circ}C$), as well as a higher coercive electric field ($E_C=6.3kV/cm$) and internal bias field ($E_I=1.6kV/cm$). The (011) PMN-PZT-Mn single crystals showed the highest coercive electric field ($E_C=7.0kV/cm$), and the highest stability of $E_C$ and $E_I$ during 60 cycles of polarization measurement. These results demonstrate that both Mn doping (for higher electromechanical quality factor ($Q_m$)) and a (011) crystallographic orientation (for higher coercive electric field and stability) are necessary for high power transducer applications of these piezoelectric single crystals. Specifically, the (011) PMN-PZT-Mn single crystal (Gen. III) had the highest potential for application in the fields of SONAR transducers, high intensity focused ultrasound (HIFU), ultrasonic motors, and others.

전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구 (A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia)

  • 박문규;노시철;박재현;최흥호
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.

지방 조직 유화를 위한 집속형 초음파 변환기 설계 및 제작에 관한 연구 (A Study on the Design and Fabrication of Fat Emulsification Adapted Focused Ultrasonic Transducer)

  • 김주영;김재영;정현두;노시철;문창수;문치웅;최흥호
    • 전자공학회논문지
    • /
    • 제52권11호
    • /
    • pp.127-134
    • /
    • 2015
  • 초음파를 이용한 조직 자극 기법은 지속적으로 연구, 개발되고 있으며, 최근 미용 및 비만 치료에 대한 관심이 높아짐에 따라 초음파 지방 제거술에 대한 다양한 연구가 진행되고 있다. 본 연구에서는 초음파 지방 제거술을 위한 초음파 변환기를 설계하고, 조사조건에 따른 집속영역의 형태와 열 변성 영역을 시뮬레이션 하였다. 이를 통하여 제원을 검증하였으며, 제작된 변환기의 초음파 방사 특성 및 가열 특성을 측정하여 유효성을 평가하였다. 또한 복합 구조의 매질을 대상으로 초음파 가열 특성을 예측하였으며 제작된 변환기의 집속점 형태 및 가열 특성이 지방층을 충분히 유화시킬 수 있을 것으로 판단하였다. 본 연구의 결과는 보다 효율적이고 안전한 초음파 지방 제거술의 기초 연구로 활용될 것으로 사료된다.

마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발 (Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle)

  • 김준태;주규태;차은종;김명미;정진형
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.394-402
    • /
    • 2021
  • 고령사회의 진입과 인간의 평균 수명이 연장되고, 여성의 사회적 진출 및 남성들의 외모에 대한 관심증가, 미디어 매체를 통한 K-문화가 전 세계적으로 관심을 받으면서 자연스럽게 관심은 K-Bueaty에 집중되고 있다. 최근, 의료관광 분야의 점유를 보면 성형 및 피부과와 같은 피부미용 의료관광의 경우 중국, 일본 등 아시아뿐만 아니라 북미, 유럽 등에서 인기를 누리고 있다. 사람의 노화를 가장 먼저 외면적으로 확인할 수 있는 부위는 바로 얼굴의 피부 주름이다. 깨끗하고 주름이 없으면서 탄력성 있는 건강한 피부는 대부분의 사람들이 원하는 바람이다. 대표적으로 집속형초음파자극(HIFU:High Intensity Focused Ultrasound)와 저주파, 고주파(RF:Radio Frequency), 미세전류를 이용한 갈바닉 테라피, 급속 냉각을 이용한 크라이오 테라피 등 피부의 컨디션과 상태에 따라 관리하는 방식이 달라지며, 같은 기전을 이용한 의료기기 및 피부미용 기기의 시술 역시 출력 및 자극 부위 등에 따라 시술의 효과가 차이가 난다. 본 연구는 수많은 피부미용 의료기기 및 미용기기 중 마이크로니들을 이용한 침습형 고주파 피부 의료기기를 개발하고자 국제규격인 IEC 60601-2(의료기기개별기준규격)및 MFDS(Ministry of Food and Drug Safety : 식품의약품안전처)에서 고시한 고주파 자극기 기준 규격을 준수한 고주파 출력 장치를 설계 및 개발하였다. 회로 설계는 Class-A Topology를 이용한 증폭장치(AMP:Amplifier)와 Half-Bridge Topology를 이용한 전원장치로 이루어져 있다. 개발된 고주파 출력 장치를 측정한 결과 평균 63.86%의 효율을 얻었으며, 최대출력은 116.7W, 50.67dBm으로 측정되었다.

집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험 (Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges)

  • 김준태;김주희;주규태;김경아;최안렬;조재현;정진형
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.477-484
    • /
    • 2022
  • 본 연구는 집속형초음파자극시스템의 카트리지부를 시료로 사용하여 의료기기 안전성 평가 기준인 GLP(Good Laboratory Practice)에 관한 시험 중 동물실험을 통한 피부 자극 시험 및 피부 감작성시험을 진행하였다. New Zealand White Rabbit 암컷 6마리를 이용하여 IACUC 승인 후 시험을 진행하였으며, 실험기간 동안 사망한 개체 수는 없었으며, 실험동물에서 어떤 이상 증상도 관찰되지 않았다. 극성, 비극성 자극 지수는 모두 '0.0'으로 나타났다. 또한, 피부감작성 평가의 경우 IACUC 승인을 통한 기니피그 30마리를 통하여 대조군 및 실험군으로 나누어 시험검체 및 공시험액을 별도의 희석 없이 용출액 자체를 사용하여 모든 유도 및 유발단계를 적용하였다. 실험결과대조동물의 피부반응 등급은 0등급이었으며, 시험동물의 피부반응에서 1등급 이상을 나타내는 동물은 없었다. 두 시험 결과에서 피부의 이상 증상은 발견되지 않았으며, 인체에 적용하여 환자를 치료할 경우 시험에 사용된 시험재료로부터 피부의 이상 증상이 생기는 질환 등은 나타나지 않는지에 관하여 안정성을 알아 보고자 하였다.

집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰 (Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems)

  • 김준태;김주희;주규태;김경아;류옥수;조재현;정진형
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.164-177
    • /
    • 2022
  • 의료기기 사용적합성 평가란 최종 시제품 제작 완료이전 실제 사용자를 통한 의료기기의 평가를 말한다. 국제전자의료기기 안전규격 중 하나인 IEC 62366은 유럽 및 미국 등 주요 선진국의 의료기기 인허가 획득을 위해 반드시 적용해야 하는 규격이다. 국내의 경우 식약처 고시를 통하여 2021년 1월부터 등급별로 순차적 적용을 시행하고 있다. 본 연구에서는 (주)이끌레오에서 개발 중인 집중형초음파자극시스템의 사용자 적합성 평가 중 형성평가를 인천 G 대학 병원 의료기기융합 센터를 통하여 참가자 전문의 15인을 모집하였고, 공동 시나리오 개발을 통하여 시험을 진행하였다. 작업 수행 여부 결과에서는 90.67%의 수행율을 보였으며, 수행 완료 후 참가자 설문 조사결과 문항별 결과 분석에서 '사용자 인터페이스의 용이성' 86.67%, '정보의 식별성/가독성/이해도' 문항에서 94%의 보통 이상의 응답 비율을 보였다.