• 제목/요약/키워드: HI test

검색결과 480건 처리시간 0.03초

Serologlcal survey of infections agents in domesticated boars

  • Cho, Kwang-Hyun;Park, In-Hwa;Kim, Young-Hoan;Kim, Soon-Tae;Kim, Sung-Kook;Park, No-Chan;Son, Jae-Kwon;Jyeong, Jong-Sik
    • 한국동물위생학회지
    • /
    • 제24권4호
    • /
    • pp.359-367
    • /
    • 2001
  • A serological survey was performed to establish basic data for the prevalence of antibodies to some major diseases of domesticated boar serum samples from January to December 2000. Sera collected in breeding farms in Gyeongbuk province were tested for Aujeszky's disease virus(ADV), Porcine reproductive and respiratory syndrome virus(PRRSV), Porcine parvovirus(PPV), Japanese encephalitis virus (JEV), Bordetella bronchiseptica(B bronchiseptica), Mycoplasma ; APP), Toxoplasma, and Brucella. There was no antibody to ADV in domesticated boars serum samples detected by Anti-ADV-gpI assay kit. Sero-positive samples to PRRS by IFA were 0.9%(3/330) The HI titers to PPV ranged variously from less than 10 to over 1,280. Two hundred ninety-four out of 330 tested sera showed HI titer of less than 10. In HI test to JEV, 90.3% of the sera (298/330) were below 10. The majority of the serum samples had low prevalence of the antibody B bronchiseptica. ELISA titers to M hyopneumoniae ranged variously from $\leq$ 10 to $\geq$ 1,280. Antibody titers to A pleuropneumoniae type 2(APP2) and type 5(APP5) were 58.2% and 52.7%, respectively, and the tested samples showing ELISA antibody titers of less than 20. There was no significant geographical difference between APP2 and APP5 in this study. In the antibody test of Toxoplasma, 11.5%(38/330) were positive and samples were all negative in sera test of Brucella.

  • PDF

기준 메모리를 이용한 메모리 컴파일러 특성화 방법 (Characterization Method of Memory Compiler Using Reference Memories)

  • 신우철;송혜경;정원영;조경순
    • 전자공학회논문지
    • /
    • 제51권2호
    • /
    • pp.38-45
    • /
    • 2014
  • 본 논문에서는 메모리 컴파일러를 정확하고 빠르게 특성화할 수 있도록 기준 메모리를 기반으로 특성화하는 방법을 제안하였다. 제안한 특성화 방법은 메모리 컴파일러의 정확도를 유지하면서 특성화 시간을 최소화하기 위해 메모리 컴파일러의 타이밍 경향을 분석하고 분석 결과를 토대로 기준 메모리를 선정하고, 메모리간의 경향성을 대변할 수 있도록 모델링하였다. 본 논문에서 제안한 방법론을 검증하기 위하여 130nm에서 개발된 메모리 컴파일러를 제안한 방법을 이용하여 110nm 메모리 컴파일러를 특성화하였다. 이를 통해 생성한 메모리들의 특성과 SPICE를 사용하여 특성화한 결과를 비교하여 메모리 타이밍의 평균 오차율은 ${\pm}0.1%$ 이내였으며 실제 110nm 공정을 사용하여 제작된 메모리 BIST(Built-In Self Test) 테스트 칩으로 기능 검사한 결과, 수율(Yield)이 98.8% 임을 확인하였다. 또한, 180nm 공정을 사용하여 비교한 결과, 수율이 98.3%로 그 유용성을 확인할 수 있었다.

Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study

  • Dalili, Zahra;Taramsari, Mehran;Mehr, Seyed Zoheir Mousavi;Salamat, Fatemeh
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.19-24
    • /
    • 2012
  • Purpose : Field of view and voxel resolution of cone beam computed tomography (CBCT) might affect the diagnostic capability. This study was performed to compare between the standard and HiRes zoom modes in the diagnosis of external root resorption (ERR) using CBCT. Materials and Methods : Sixty three small cavities (0.25 mm depth and 0.5 mm diameter) were simulated on the buccal, lingual, and proximal surfaces at three different levels of 16 roots of teeth. After covering the root with nail varnish, the roots were inserted in the sockets and the model was placed in a water-containing lacuna. CBCT scans were taken in both standard and HiRes zoom modes using NewTom VG (QR srl Company, Verona, Italy). Then, an observer assessed the images to determine the presence or absence of the cavities. This process was repeated by increasing the size and depth of cavities to 0.5 mm depth and 1 mm diameter. Data were analyzed by McNemar test. The sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratio in evaluation of the simulated cavities were calculated. Results : There was a significant difference between the two imaging modes in diagnosing the shallow cavities (p=0.02).The sensitivity of the standard zoom in detecting the shallow cavities was lower than that of the HiRes zoom. The likelihood ratio of the HiRes zoom was higher in the diagnosis of both cavity types. Conclusion : This study suggested that a smaller voxel size in the HiRes zoom mode of CBCT is preferred for diagnosis of ERR.

Comparison of the MGISEQ-2000 and Illumina HiSeq 4000 sequencing platforms for RNA sequencing

  • Jeon, Sol A;Park, Jong Lyul;Kim, Jong-Hwan;Kim, Jeong Hwan;Kim, Yong Sung;Kim, Jin Cheon;Kim, Seon-Young
    • Genomics & Informatics
    • /
    • 제17권3호
    • /
    • pp.32.1-32.6
    • /
    • 2019
  • Currently, Illumina sequencers are the globally leading sequencing platform in the next-generation sequencing market. Recently, MGI Tech launched a series of new sequencers, including the MGISEQ-2000, which promise to deliver high-quality sequencing data faster and at lower prices than Illumina's sequencers. In this study, we compared the performance of two major sequencers (MGISEQ-2000 and HiSeq 4000) to test whether the MGISEQ-2000 sequencer delivers high-quality sequence data as suggested. We performed RNA sequencing of four human colon cancer samples with the two platforms, and compared the sequencing quality and expression values. The data produced from the MGISEQ-2000 and HiSeq 4000 showed high concordance, with Pearson correlation coefficients ranging from 0.98 to 0.99. Various quality control (QC) analyses showed that the MGISEQ-2000 data fulfilled the required QC measures. Our study suggests that the performance of the MGISEQ-2000 is comparable to that of the HiSeq 4000 and that the MGISEQ-2000 can be a useful platform for sequencing.

농가 생산성 증대를 위한 육계 초생추 질병 실태조사 (A survey on diseases to improve productivity in 1-day-old chicks of broiler farms)

  • 고원석;엄성심;조범준;;이병종;이성효;배정준
    • 한국동물위생학회지
    • /
    • 제30권3호
    • /
    • pp.329-338
    • /
    • 2007
  • Samples collected from 15 broiler farms(47 flocks, 920 1-day-old chicks) during March to December, 2006, To survey serum antibody titers of NDV, IBDV and MG/MS, the antibodies of ND viruses were detected by HI test and ELISA, against antibodies of IBD viruses and MG/MS by ELISA. The antibody titers of NDV showed 6.4, HI and 6,968, ELISA, respectively. The rate to below protective antibody levels(${\ge}5$, HI and ${\ge}1,000$, ELISA) were 8%, HI, 5%, ELISA, specially, Baeksemi were 22%, HI, 14%, ELISA. The rate of positive by ELISA showed 99%(914/920). The ELISA titer of IBDV showed mean titer 3,890. The rate of positive were 93% (857/920), specially, Baeksemi were 84%. The ELISA titers of MG/MS showed mean titer 5,666. The rate of positive were 78% (715/920) and 100%, Abor-Acre, 97%, Baeksemi, respectively. The antibodies not detected from 18%, ELISA titers was varied from 500 to 20,000. At antimicrobial susceptibility of E coli, Staphylococcus spp and Salmonella spp isolated from 1-day-old chicks, E coli were susceptible to AmC, AM, NOR, SXT, ENR, CIP, Staphylococcus spp were susceptible to AmC, SXT, AM, ENR and Salmonella spp were susceptible to AM, AmC, SXT and P.

Improvement of indirect enzyme-linked immunosorbent assay for detection of Japanese encephalitis virus antibodies in swine sera

  • Yang, Dong-Kun;Kim, Ha-Hyun;Jo, Hyun-Ye;Lee, Seung Heon;Jang, Sang-Ho;Lee, Sang-Oh;Choi, Sung-Suk;Cho, In-Soo
    • 대한수의학회지
    • /
    • 제57권1호
    • /
    • pp.31-36
    • /
    • 2017
  • Japanese encephalitis (JE) is an important zoonosis caused by the mosquito-transmitted JE virus (JEV), which is a causative agent of reproductive failure in pregnant sows. Detection of JEV antibodies in swine is performed by hemagglutination inhibition (HI), virus neutralization (VN), and the plaque reduction neutralization test (PRNT). The most stringent PRNT is the 90% endpoint PRNT ($PRNT_{90}$). These conventional assays are difficult to carry out in diagnostic laboratories with insufficient instruments or cell culture systems. An alternative assay that is easily conducted and time efficient is required. In this study, we improved the indirect enzyme-linked immunosorbent assay (I-ELISA) with clarified antigen for the detection of JEV antibodies. The I-ELISA results obtained from 175 swine serum samples were compared with HI, VN, and $PRNT_{90}$ results. The sensitivity of I-ELISA was 91.8%, 95.0%, and 94.7% compared with HI, VN, and $PRNT_{90}$ results, respectively. The specificity of I-ELISA was 92.2%, 94.7%, and 94.7% compared with HI, VN, and $PRNT_{90}$ results, respectively. Moreover, the I-ELISA results were significantly correlated with the HI (r = 0.93), VN (r = 0.95), and $PRNT_{90}$ (r = 0.92) results. These results suggest that the improved I-ELISA is useful for serosurveillance of JEV in swine.

두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향 (The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT)

  • 엄기천;김가중;백금문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.239-246
    • /
    • 2023
  • In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom's body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

The Biphasic Effect of Retinoic Acid Signaling Pathway on the Biased Differentiation of Atrial-like and Sinoatrial Node-like Cells from hiPSC

  • Feng Liu;Dandan Long;Wenjun Huang;Wanling Peng;Huan Lan;Yafei Zhou;Xitong Dang;Rui Zhou
    • International Journal of Stem Cells
    • /
    • 제15권3호
    • /
    • pp.247-257
    • /
    • 2022
  • Background and Objectives: Although human-induced pluripotent stem cells (hiPSC) can be efficiently differentiated into cardiomyocytes (CMs), the heterogeneity of the hiPSC-CMs hampers their applications in research and regenerative medicine. Retinoic acid (RA)-mediated signaling pathway has been proved indispensable in cardiac development and differentiation of hiPSC toward atrial CMs. This study was aimed to test whether RA signaling pathway can be manipulated to direct the differentiation into sinoatrial node (SAN) CMs. Methods and Results: Using the well-characterized GiWi protocol that cardiomyocytes are generated from hiPSC via temporal modulation of Wnt signaling pathway by small molecules, RA signaling pathway was manipulated during the differentiation of hiPSC-CMs on day 5 post-differentiation, a crucial time point equivalent to the transition from cardiac mesoderm to cardiac progenitor cells in cardiac development. The resultant CMs were characterized at mRNA, protein and electrophysiology levels by a combination of qPCR, immunofluorescence, flow cytometry, and whole-cell patch clamp. The results showed that activation of the RA signaling pathway biased the differentiation of atrial CMs, whereas inhibition of the signaling pathway biased the differentiation of sinoatrial node-like cells (SANLCs). Conclusions: Our study not only provides a novel and simple strategy to enrich SANLCs but also improves our understanding of the importance of RA signaling in the differentiation of hiPSC-CMs.

선별 검사를 위한 탁상용 폐활량기 (HI-801)의 임상적 유용성에 관한 고찰 (Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening)

  • 최혜숙;최천웅;박명재;강홍모;유지홍
    • Tuberculosis and Respiratory Diseases
    • /
    • 제62권4호
    • /
    • pp.276-283
    • /
    • 2007
  • 연구배경: 폐활량 검사는 간단하고 저렴한 폐질환의 선별 검사방법으로 흡연자나 호흡기 증상이 있는 환자에게 폐질환의 조기 발견을 위한 선별검사로 권고되고 있으며, 이에 따라 간단하고 저렴한 탁상용 폐활량 기기들이 공급되고 있다. 본 연구의 목적은 환기장애 소견을 보인 환자를 대상으로 탁상용 폐활량기와 병원 폐기능 검사실의 폐활량기의 폐활량 측정값을 비교 분석하여 그 일치도를 알아보고 이를 통해 탁상용 폐활량기의 임상환경에서의 정확성과 두 기기간의 임상적 상호 대체 허용성을 알아보고자 하였다. 방법: 2006년 4월부터 2006년 9월까지 경희의료원 건강검진 센터에서 HI-801기로 폐활량검사를 시행한 사람들 중 환기장애 소견을 보인 환자를 대상으로 폐기능 검사실에서 Vmax spectra 22d 폐활량기로 재검사를 시행하였다. 결과: 총 109명의 환자가 참여하였으며, 이 중 남자가 70명(64.2%)이었다. HI-801 기와 Vmax spectra 22d기로 측정한 폐활량 값들은 각각 FVC($3.03{\pm}0.62$ vs. $3.38{\pm}0.67L$), $FEV_1$($2.44{\pm}0.57$ vs. $2.61{\pm}0.58L$), PEFR($5.83{\pm}2.01$ vs. $7.70{\pm}2.11L/s$), FET($5.12{\pm}1.71$ vs. $6.68{\pm}1.11sec$), $FEF_{25%-75%}$($2.61{\pm}1.09$ vs. $2.48{\pm}1.08L/s$)였다. 두 기기간의 FVC, $FEV_1$, PEFR, $FEF_{25%-75%}$ 측정값의 상관 계수는 각각 r= 0.93, 0.94, 0.81, 0.84였으며, FVC, $FEV_1$은 Bland and Altman plot에서 95% 신뢰구간의 일치도 제한에서 각각 4%, 5% 만이 ${\pm}1.96SD$ 밖에 위치하였다. 결론: 탁상용 폐활량기인 HI-801 기는 병원 폐기능 검사실 Vmax spectra 22d 기와의 비교에서 높은 상관관계와 좋은 일치도를 보여, 탁상용 HI-801 기의 정확성을 알 수 있었으며, HI-801로 측정한 FVC, $FEV_1$ 값은 Vmax spectra 22d 기의 측정값을 임상적으로 대체할 수 있음을 보여주었다.

납착용 매몰재의 경화팽창과 열팽창에 관한 연구 (A STUDY FOR SETTING AND THERMAL EXPANSION OF DENIAL SOLDERING INVESTMENTS)

  • 신성애;임장섭;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제37권6호
    • /
    • pp.730-740
    • /
    • 1999
  • The purpose of this study was to investigate setting and thermal expansion of dental soldering investments. In order to compare expansion rates and to investigate the effect of water/powder ratio on expansion, setting and thermal expansion of low dental soldering investments were measured under three different water/powder ratio conditions. standard, 20% decreased and 20% increased. Setting expansion of investments was measured by use of dialgauge method. Each measurement was started two minutes later from the beginning of spatulation and recorded every one minute for one hour. Thermal expansion of cylindrical test specimens, 10mm diameter, 50mm length, was recorded in a thermodilatometer at heating rate of $10^{\circ}C$ per minute from $25^{\circ}C\;to\;700^{\circ}C$. The results of this study were obtained as follows: 1. Setting expansion rates under the standard water/powder ratio condition were 0.198% in Speed-E, 0.090% in Deguvest, 0.080% in CM and Hi-temp. Setting expansion of Speed-E was significantly different from those of CM, Deguvest and Hi-temp, and setting expansion of Deguvest was significantly different from those of CM and Hi-temp(p<.05). 2. Under the decreased water/powder ratio condition, there was significant increase in setting expansion of 4 dental soldering investments (p<.05). 3. There were no significant differences in setting expansions of investments except Hi-temp between standard and increased water/powder ratio condition(p<.05). 4. Thermal expansion rates under the standard water/powder ratio condition were 1.923% in Deguvest, 1.629% in Speed-E, 1.619% in Hi-temp and 1.580% in CM. No significant differences in thermal expansions under the standard water/powder ratio condition existed only between Speed-I and Hi-temp(p<.05) 5. Under the decreased water/powder ratio condition, there was significant increase in thermal expansion of CM and Deguvest but decrease in thermal expansion of Speed-E (p<.05). 6. Under the increased water/powder ratio condition, there was significant decrease in thermal expansion of CM, Deguvest and Speed-I but decrease in thermal expansion of Hi-temp(p<.05).

  • PDF