• Title/Summary/Keyword: HI concentration

Search Result 238, Processing Time 0.039 seconds

Cloning and Characterization of the Lactococcus lactis subsp. lactis ATCC 7962 pts HI Operon

  • Kim, Tea-Youn;Park, Rae-Jun;Chang, Hae-Choon;Chung, Dae-Kyun;Lee, Jong-Hoon;Lee, Hyong-Joo;Kim, Jeong-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.6
    • /
    • pp.829-835
    • /
    • 2000
  • The ptsH and ptsI genes of Lactococus lactis subsp. lactis ATCC 7962 (L. lactis 7962), encoding the general proteins of phosphotransferase system (PTS) components, HPr and enzyme I, respectively, were cloned and characterized. A 1.3 kb PCR product was obtained using a primer set that was hybridized to the internal region of the L. lactis 7962 pts HI genes and then subcloned into a low-copy number vector, pACYC184. The 5' upstream and 3' downstream region from the 1.3 kb fragment were subsequently clone using the chromosome walking method. The complete ptsHI operon was constructed and the nucleotide sequences determined. Two ORFs corresponding to HPr (88 amino acids) and enzyme I (575 amino acids) were located. The ptsHI genes of L. lactis 7962 showed a very high homology (84-90%) with those genes from other Gram-positive bacteria. A primer extension analysis showed that the transcription started at either one of two adjacent bases upstream of the start codon. Using a Northern analysis, two transcripts were detected; the first, a 0.3 kb transcript corresponding to ptsH and the second, a 2 kb transcript corresponding to ptsH and ptsI. The transcription level of ptsH was higher than that of ptsI. The concentration of the ptsH transcript in cells grown on glucose was similar to that in cells grown on lactose, yet higher than that in cells grown on galactose. The ptsI transcript was scarcely detected in cell grown on lactose or galactose. The ptsI transcript was scarcely detected in cells grown on lactose or galactose. The results of a sequence analysis and Northern blot confirmed that the ptsH and ptsI genes of L. lactis 7962 were arranged in an operon like other known ptsHI genes and the expression of the ptsHI genes was regulated at the transcriptional level in response to the carbon source.

  • PDF

Strain-Relaxed SiGe Layer on Si Formed by PIII&D Technology

  • Han, Seung Hee;Kim, Kyunghun;Kim, Sung Min;Jang, Jinhyeok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.155.2-155.2
    • /
    • 2013
  • Strain-relaxed SiGe layer on Si substrate has numerous potential applications for electronic and opto- electronic devices. SiGe layer must have a high degree of strain relaxation and a low dislocation density. Conventionally, strain-relaxed SiGe on Si has been manufactured using compositionally graded buffers, in which very thick SiGe buffers of several micrometers are grown on a Si substrate with Ge composition increasing from the Si substrate to the surface. In this study, a new plasma process, i.e., the combination of PIII&D and HiPIMS, was adopted to implant Ge ions into Si wafer for direct formation of SiGe layer on Si substrate. Due to the high peak power density applied the Ge sputtering target during HiPIMS operation, a large fraction of sputtered Ge atoms is ionized. If the negative high voltage pulse applied to the sample stage in PIII&D system is synchronized with the pulsed Ge plasma, the ion implantation of Ge ions can be successfully accomplished. The PIII&D system for Ge ion implantation on Si (100) substrate was equipped with 3'-magnetron sputtering guns with Ge and Si target, which were operated with a HiPIMS pulsed-DC power supply. The sample stage with Si substrate was pulse-biased using a separate hard-tube pulser. During the implantation operation, HiPIMS pulse and substrate's negative bias pulse were synchronized at the same frequency of 50 Hz. The pulse voltage applied to the Ge sputtering target was -1200 V and the pulse width was 80 usec. While operating the Ge sputtering gun in HiPIMS mode, a pulse bias of -50 kV was applied to the Si substrate. The pulse width was 50 usec with a 30 usec delay time with respect to the HiPIMS pulse. Ge ion implantation process was performed for 30 min. to achieve approximately 20 % of Ge concentration in Si substrate. Right after Ge ion implantation, ~50 nm thick Si capping layer was deposited to prevent oxidation during subsequent RTA process at $1000^{\circ}C$ in N2 environment. The Ge-implanted Si samples were analyzed using Auger electron spectroscopy, High-resolution X-ray diffractometer, Raman spectroscopy, and Transmission electron microscopy to investigate the depth distribution, the degree of strain relaxation, and the crystalline structure, respectively. The analysis results showed that a strain-relaxed SiGe layer of ~100 nm thickness could be effectively formed on Si substrate by direct Ge ion implantation using the newly-developed PIII&D process for non-gaseous elements.

  • PDF

Shipboard Verification Test of Onboard Carbon Dioxide Capture System (OCCS) Using Sodium Hydroxide(NaOH) Solution (가성소다(NaOH) 용액을 이용한 선상 이산화탄소 포집 장치의 선박 검증시험)

  • Gwang Hyun Lee;Hyung Ju Roh;Min woo Lee;Won Kyeong Son;Jae Yeoul Jeong;Tae-Hong Kim;Byung-Tak NAM;Jae-Ik Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.61 no.1
    • /
    • pp.51-60
    • /
    • 2024
  • Hi Air Korea and Hanwha ocean are currently developing an Onboard Carbon dioxide Capture System (OCCS) to absorb CO2 emitted from ship's engine using a sodium hydroxide(NaOH) solution, and converting the resulting salt into a solid form through a chemical reaction with calcium oxide (CaO). The system process involves the following steps; 1)The reaction of CO2 gas absorption in water, 2)The reaction between carbonic acid (H2CO3) and NaOH solution to produce carbonate or bicarbonate, and 3)The reaction between carbonate or bicarbonate and CaO to form calcium carbonate (CaCO3). And ultimately, the solid material, CaCO3, is separated and discharged using a separator. The OCCS has been installed on an ship and the test results have confirmed significant reduction effects of CO2 in the ship's exhaust gas. A portion of the exhaust gas emitted from the engine was transferred to the OCCS using a blower. The flow rate of the transferred gas ranged from 800 to 1384 m3/hr, and the CO2 concentration in the exhaust gas was 5.1 vol% for VLSFO, 3.7 vol% for LNG and a 12 wt% NaOH solution was used. The results showed a CO2 capture efficiency of approximately 42.5 to 64.1 vol% and the CO2 capture rate approximately 48.4 to 52.2kg/hr. Additionally, to assess the impact of the discharged CaCO3on the marine ecosystem, we conducted "marine ecotoxicity test" and performed Computational Fluid Dynamics (CFD) analysis to evaluate the dispersion and dilution of the discharged effluent.

Fatigue Strength of CRHS Joints Subjected to Out-of-plane Bending

  • Bian, Li-Chun;Jeon, Yang-Bae;Yoon, Ho-Cheol;Lim, Jae-Kyoo
    • Proceedings of the KWS Conference
    • /
    • 2002.05a
    • /
    • pp.178-181
    • /
    • 2002
  • This is a partial report of the investigation of fatigue behaviour of hollow section T-joints with circular brace members and rectangular chord members (CRHS). Hot spot stresses and the stress concentration factors (SCFs) were determined experimentally. Fatigue testing was carried out under constant amplitude loading in air. The experimental SCF values for CRHS joints were found to be below those of circular-to-circular (CCHS) and rectangular-to-rectangular (RRHS) hollow section joints. The fatigue strength referred to experimental hot spot stress was in reasonably good agreement with current fatigue design codes for tubular joints.

  • PDF

A Study on Fatigue Crack Propagation Mechanism of GFRP in Synthetic Sea Water

  • Kim, Yon-Jig;Lim, Jae-Kyoo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.10
    • /
    • pp.1380-1385
    • /
    • 2001
  • This paper evaluates the fatigue fracture behavior of a chopped strand glass mat/polyester composite both in ai, and sea water, Bending fatigue (R=-1) was performed on dry and wet specimens, that is respectively in air and sea water. Where the pH concentration of sea water was controlled to 6.0,8.2, 10.0 and the wet specimens were immersed in the sea waters for 4 months. Throughout the tests, fatigue cracks both in the dry and wet specimens, tested in the air or sea water, occurred at the beginning of the cycle, followed by either of two regions one decreasing and the other increasing as the crack growth rate increases.

  • PDF

Fatigue Fracture Behaviour of Hollow Section Joints

  • Lichun Bian;Lim, Jae-Kyoo
    • Proceedings of the KWS Conference
    • /
    • 2001.10a
    • /
    • pp.281-284
    • /
    • 2001
  • Fatigue behaviour of eight different hollow section T-joints was investigated experimentally using scaled steel models. The joints had circular brace members and rectangular chords (CRHS). Hot spot stresses and the stress concentration factors (SCFs) were determined experimentally. Fatigue testing was carried out under constant amplitude loading in air. The experimental SCF values for CRHS joints were found to be between those of circular-to-circular (CCHS) and rectangular-to-rectangular (RRHS) hollow section joints. The fatigue strength referred to experimental hot spot stress was in reasonably good agreement with current fatigue design codes for tubular joints.

  • PDF

Determination of lead content in the plastic by ICP and AAS using HI reduction - PbSO4 dissolution method (HI 환원-PbSO4용해법을 이용한 ICP와 AAS에 의한 플라스틱 중의 납 정량 방법)

  • Lee, Hyun-Ja;Kim, Sang-Kyung;Lee, Se-Jin;Lee, Hyun-A
    • Analytical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.369-374
    • /
    • 2004
  • Plastic was decomposed with nitric acid after being carbonized by sulfuric acid. Then excess sulfuric acid and nitric acid was removed by evaporating and drying. Precipitated $SO{_4}^{-2}$ ion of $PbSO_4$ was resolved itself into $H_2S$ by HI in hydrochloric acid and was volatilized. Then $Pb^{+2}$ was dissolved and was measured by AAS and ICP. The test for reproducibility using PVC-Pb standard material (690-34610mg/kg) was conducted and the accuracy was more than 99.9% compared with the estimated concentration. The precision by AAS was 99.8% and that of ICP was 99.9%.

Efficiency calculation of the nMCP with 10B doping based on mathematical models

  • Yang, Jianqing;Zhou, Jianrong;Zhang, Lianjun;Tan, Jinhao;Jiang, Xingfen;Zhou, Jianjin;Zhou, Xiaojuan;Hou, Linjun;Song, Yushou;Sun, XinLi;Zhang, Quanhu;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2364-2370
    • /
    • 2021
  • The nMCP (Neutron sensitive microchannel plate) combined with advanced readout electronics is widely used in energy selective neutron imaging because of its good spatial and timing resolution. Neutron detection efficiency is a crucial parameter for the nMCP. In this paper, a mathematical model based on the oblique cylindrical channel and elliptical pore was established to calculate the neutron absorption probability, the escape probability of charged particles and overall detection efficiency of nMCP and analyze the effects of neutron incident position, pore diameter, wall thickness and bias angle. It was shown that when the doping concentration of the nMCP was 10 mol%, the thickness of nMCP was 0.6 mm, the detection efficiency could reach maximum value, about 24% for thermal neutrons if the pore diameter was 6 ㎛, the wall thickness was 2 ㎛ and the bias angle was 3 or 6°. The calculated results are of great significance for evaluating the detection efficiency of the nMCP. In a subsequent companion paper, the mathematical model would be extended to the case of the spatial resolution and detection efficiency optimization of the coating nMCP.

Optimization of Fractionation Conditions for Natural Organic Matter in Water by DAX-8 Resin and its Application to Environmental Samples (DAX-8 레진의 수중 자연유기물의 분획조건 최적화 및 환경시료에의 적용)

  • Lim, Hyebin;Hur, Jin;Kim, Joowon;Shin, Hyunsang
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.3
    • /
    • pp.133-142
    • /
    • 2022
  • Natural organic matter (NOM) is a heterogeneous mixture of organic matter with various polarities and molecular weights in an aquatic environment. This study investigated the effects of separation conditions (resin volume, organic matter, etc.) and the repeated use of the resin for the fractionation of organic components in the DAX resin fractionation method. The distribution characteristics of the organic components ((hydrophilic [Hi], hydrophobic acid [HoA], and hydrophobic neutral [HoN]) under the derived fractionation conditions were also analyzed. Constant fractionation results (i.e. HoA/Hi ratio) were obtained in the column capacity factor (i.e. the packed resin volume) in the range of 50 to 100. The resin-packed column maintained constant separation efficiency for up to two repeated uses. The above conditions were applied to wastewater and stream water samples (before and after rainfall). The results showed that the concentration of organic matter in the wastewater effluent was 2-15 times lower with an increased ratio of hydrophilicity to hydrophobicity (i.e. Ho/Hi) compared to the influent depending on the industrial wastewater classification. Particularly, HoN was found to have a high content distribution, 10.2-50.4% of the total dissolved organic matter (DOM), in the effluents. For the stream water, the content of Hi or HoN increased significantly after rainfall, suggesting a correlation with the distribution characteristics of pollutants from the stream watershed. The results provide useful data to enhance the reliability of the DAX resin fractionation and its application to environmental samples.

Risk assessment for Soil Contamination Warning Standard and Soil Background Concentration (토양오염 우려기준과 토양 자연배경농도에 대한 위해성평가)

  • Shin, Dong;Park, Seong-Jae;Jo, Young Tae;Bong, Jae-eun;Park, Jeong-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.3
    • /
    • pp.37-49
    • /
    • 2021
  • There is domestic Soil Contamination Warning Standard (SCWS) as remediation standard concentration of contaminated soils. No risk should be observed at soil concentration less than SCWS. Therefore, SCWS was evaluated to confirm the risk assessment. Background Concentration of Soil (BGC) and target remediation concentration were also assessed. The results show that Excess Cancer Risk (ECR) of SCWS was the highest in the groundwater intake pathway (Adult: 6.27E-04, Child: 2.81E-04). Total Cancer Risk (TCR) was 7.76E-04 and 4.30E-04 for adult and child, exceeding reference value (10-6). Hazard Quotient (Non-Carcinogenic Risk, HQ) was the highest in the indoor air inhalation pathway (Adult: 3.64E+03, Child: 8.74E+02). Hazard Index (Total Non-Carcinogenic Risk, HI) exceeded reference value 1. ECR of the BGC was the highest in the groundwater intake pathway (Adult: 1.71E-04, Child: 7.67E-05). TCR was 2.12E-04 for adults and 1.17E-04 for children, exceeding the reference value (10-6). HQ was the highest in groundwater intake pathway (Adult: 4.10E-01, Child: 1.84E-01). HI was lower than reference value 1 (Adult: 4.78E-01, Child: 2.50E-01). The heavy metal affecting ECR was Arsenic (As). The remediation-concentration of As was 7.14 mg/kg which is higher than BGC (6.83 mg/kg). TCR of As should be less than reference value (10-6), but it was higher for all of SCWS, BGC and target remediation concentration. Therefore, it is suggested that risk assessment factors should be re-evaluated to fit domestic environmental settings and SCWS should be induced to satisfy the risk assessment.