• Title/Summary/Keyword: HHF

Search Result 20, Processing Time 0.025 seconds

Numerically-Investigated Thermal Performances of Hybrid Fin Heat Sinks for Lightweight Thermal Management of LED Modules Under Natural Convection (자연대류상의 LED 모듈의 경량열관리를 위한 하이브리드 휜 히트싱크의 수치적으로 조사된 열성능)

  • Kim, Kyoung Joon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.586-591
    • /
    • 2015
  • This study discusses numerically-explored thermal performances of hybrid fin heat sinks (HF HSs) for lightweight thermal management of LED modules under natural convection. A hollow hybrid fin heat sink (HHF HS) and a solid hybrid fin heat sink (SHF HS) are proposed as HF HSs. A 3-D CFD analysis has been carefully conducted to obtain reliable numerical results. The 3-D CFD study investigates the effects of both fin spacing and an internal channel diameter on performances of the HHF HS and the SHF HS. The study results show that the mass-based thermal resistance of the HHF HS is 20~32% smaller compared with the pin fin heat sink (PF HS). The results also show that the mass-based thermal resistance of the HHF HS decreases with the increase of the channel diameter. These results are mainly due to coupled effects of the mass reduction and heat pumping through an internal channel. Considerably superior mass-based thermal performances of the HHF HS to the conventional PF HS suggest the feasible application for the lightweight thermal management of the LED modules under natural convection.

Numerical study on the thermal performance of passively cooled hybrid fins (수동적으로 냉각되는 하이브리드 휜들의 열성능에 대한 수치적 연구)

  • Jeon, Mun Soo;Kim, Kyoung Joon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.816-821
    • /
    • 2013
  • This paper reports numerical study results with respect to the thermal performance of various hybrid fins (HFs) and a pin fin (PF) passively cooled under natural convection state. Investigated HFs are a basic hybrid fin (BHF), a hollow hybrid fin (HHF), and a solid hybrid fin (SHF). CFD models for both HFs and the PF have been developed to explore their thermal performance under various heat dissipations. Thermal performances of fins have been analyzed by quantifying array-based heat transfer coefficients, $h_a$, and mass-based heat transfer coefficients, $h_m$, for each fin. Study results show that $h_a$ of the SHF is 23% greater than that of the PF. $h_m$ of the HHF is found to be even 140% greater than that of the PF, and the HHF is found to be 40% better than the BHF in terms of the mass-based performance, $h_{m{\cdot}}$.

Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans (휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Youn;Bae, Seo-Youn;Choi, Sangjun;Kim, Won;Min, Sung Hyon;Park, Jihoon;Ahn, Jongju
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

Crystallograpbic and Magnetic Properties of $Ni_{0.65}Zn_{0.35}Cu_{0.3}Fe_{1.7}O_4$ ($Ni_{0.65}Zn_{0.35}Cu_{0.3}Fe_{1.7}O_4$의 결정학적 및 자기적 특성 연구)

  • 김우철;김삼진;김철성;이승화
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.3
    • /
    • pp.136-142
    • /
    • 1999
  • $Ni_{0.65}Zn_{0.35}Cu_{0.3}Fe_{1.7}O_4$ has been studied with x-ray diffraction, Mossbauer spectroscopy, and vibrating sample magnetometer. The crystal structure is found to be a cubic spinel with the lattice constant $a_0=8.403{\AA}$. Mossbauer spectra of have been taken at various temperatures ranging from 12 K to 665 K. as the temperature increases toward $T_N$ a systematic line broadening effect in the Mossbauer spectrum is observed and interpreted to originate from different temperature dependencies of the magenetic hyperfine fields at various iron sites. Also, by using binomial distribution equation we obtained the hyperfine fields of tetrahedral[A] and octahedral sites[B], $H_{hf}(A)=470\;kOe,\; H_{hf}(B0)=495 \;kOe,\; H_{hf}(B1)=485\;kOe, \;H_{hf}(B2)=453\;kOe,\; H_{hf}(B3)=424\;kOe,\; H_{hf}(B4)=390\;kOe,\; H_{hf}(Bavr)=451\;kOe$ respectively at room temperature. The isomer shift indicates that the iron ions are ferric at tetrahedral[A] and octahedral sites[B], respectively. The Neel temperature is determined to be $T_N=665\;K$. The results of the VSM data gave the magnetic moment and coercivity values of $M_S=66\; emu/g\;and\;H_C=36\;Oe$.

  • PDF

High Heat Flux Test of Cu/SS Mock-up for ITER First Wall (ITER 일차벽의 Cu/SS Mock-up에 대한 고열부하 시험)

  • Lee, D.W.;Bae, Y.D.;Hong, B.G.;Lee, J.H.;Park, J.Y.;Jeong, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.325-330
    • /
    • 2006
  • In order to verify the integrity of the first wall (FW) of the International Thermonuclear Experimental Reactor (ITER), the fabricated Cu/SS mock-up is tested in the JAEA Electron Beam Irradiation Test Stand (JEBIS). To fabricate the Cu/SS mock-up, CuCrZr and 316L authentic stainless steel (SS316L) are used for Cu alloy and steel, respectively The hot isostatic pressing (HIP) is used as a manufacturing method with a $1050^{\circ}C$ and 150 MPa. The high heat flux (HHF) test is performed using an electron beam with a heat flux of $5MW/m^2$ and a cycle of 15-sec on time and 30-sec off time. The temperature measurement in the HHF test shows good agreement with the results obtained from ANSYS code analysis, which is used for determining the HHF test conditions.

Prognostic and Safety Implications of Renin-Angiotensin-Aldosterone System Inhibitors in Hypertrophic Cardiomyopathy: A Real-World Observation Over 2,000 Patients

  • Chan Soon Park;Tae-Min Rhee;Hyun Jung Lee;Yeonyee E. Yoon;Jun-Bean Park;Seung-Pyo Lee;Yong-Jin Kim;Goo-Yeong Cho;In-Chang Hwang;Hyung-Kwan Kim
    • Korean Circulation Journal
    • /
    • v.53 no.9
    • /
    • pp.606-618
    • /
    • 2023
  • Background and Objectives: The prognostic or safety implication of renin-angiotensin-aldosterone system inhibitors (RASi) in hypertrophic cardiomyopathy (HCM) are not well established, mainly due to concerns regarding left ventricular outflow tract (LVOT) obstruction aggravation. We investigated the implications of RASi in a sizable number of HCM patients. Methods: We enrolled 2,104 consecutive patients diagnosed with HCM in 2 tertiary university hospitals and followed up for five years. RASi use was defined as the administration of RASi after diagnostic confirmation of HCM. The primary and secondary outcomes were all-cause mortality and hospitalization for heart failure (HHF). Results: RASi were prescribed to 762 patients (36.2%). During a median follow-up of 48.1 months, 112 patients (5.3%) died, and 94 patients (4.5%) experienced HHF. Patients using RASi had less favorable baseline characteristics than those not using RASi, such as older age, more frequent history of comorbidities, and lower ejection fraction. Nonetheless, there was no difference in clinical outcomes between patients with and without RASi use (log-rank p=0.368 for all-cause mortality and log-rank p=0.443 for HHF). In multivariable analysis, patients taking RASi showed a comparable risk of all-cause mortality (hazard ratio [HR], 0.70, 95% confidence interval [CI], 0.43-1.14, p=0.150) and HHF (HR, 1.03, 95% CI, 0.63-1.70, p=0.900). In the subgroup analysis, there was no significant interaction of RASi use between subgroups stratified by LVOT obstruction, left ventricular (LV) ejection fraction, or maximal LV wall thickness. Conclusions: RASi use was not associated with worse clinical outcomes. It might be safely administered in patients with HCM if clinically indicated.

Development of a Novel Passive Harmonic Filter (신개념 수동형 고조파 필터 개발과 성능에 관한 평가)

  • Park, Byoung-Ju;Lee, Han-Sang;Jang, Gil-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.29-36
    • /
    • 2006
  • The interest for harmonic problems has been increasing due to the increment of nonlinear loads. The loads such as DC power system, personal computers, UPS system, inverters and converters operate as harmonic current sources. In this paper, a new type of the passive filter, Hybrid Harmonic Filter (HHF) is suggested to mitigate harmonic problems in power systems. The HHF is developed for reducing harmonic current, especially on the system that includes 6-pulse bridge rectifiers. Also, it is expected to prevent the overheating of transformers and feeders due to overcurrent and to correct the power factor.

Performance of fly ash stabilized clay reinforced with human hair fiber

  • Rekha, L. Abi;Keerthana, B.;Ameerlal, H.
    • Geomechanics and Engineering
    • /
    • v.10 no.5
    • /
    • pp.677-687
    • /
    • 2016
  • Industrialization and urbanization are the two phenomena that are going relentless all over the world. The consequence of this economic success has been a massive increase in waste on one hand and increasing demand for suitable sites for construction on the other. Owing to the surplus raw materials and energy requirement needed for manufacturing synthetic fibers, applications of waste fibers for reinforcing soils evidenced to offer economic and environmental benefits. The main objective of the proposed work is to explore the possibilities of improving the strength of soil using fly ash waste as an admixture and Human Hair Fiber (HHF) as reinforcement such that they can be used for construction of embankments and land reclamation projects. The effect of fiber content on soil - fly ash mixture was observed through a series of laboratory tests such as compaction tests, CBR and unconfined compression tests. From the stress - strain curves, it was observed that the UCC strength for the optimised soil - flyash mixture reinforced with 0.75% human hair fibers is nearly 2.85 times higher than that of the untreated soil. Further, it has been noticed that there is about 7.73 times increase in CBR for the reinforced soil compared to untreated soil. This drastic increase in strength may be due to the fact that HHF offer more pull-out resistance which makes the fibers act like a bridge to prevent further cracking and thereby it improves the toughness which in turn prevent the brittle failure of soil-flyash specimen. Hence, the test results reveal that the inclusion of randomly distributed HHF in soil significantly improves the engineering properties of soil and can be effectively utilized in pavements. SEM analysis explained the change of microstructures and the formation of hydration products that offered increase in strength and it was found to be in accordance with strength tests.

Human Studies on Functional Foods: How They Are Regulated (기능성식품 인체적용시험 제도 비교)

  • Kim, Joo-Hee;Kim, Ji-Yeon;Won, Hye-Suk;Kwon, Hye-Jin;Kwon, Hye-Young;Jeong, Hye-In;Kwon, O-Ran
    • Journal of Nutrition and Health
    • /
    • v.43 no.6
    • /
    • pp.653-660
    • /
    • 2010
  • Along with the steady growth of health functional food (HFF) markets, research evaluating the human effects of HFF has been expanding. In this study, we investigated the regulatory and management system of human study on HFF in the USA, Japan and UK, and the Korean domestic regulations on HHF, medicines, medical devices, cosmetics and biotechnology in order to improve the domestic management system. In these four countries, institutional review board (IRB) or research ethics committee (REC) approvals are required for on human study of HHF, but regulatory and management systems differ from country to country. In the USA, human studies on HFF for structure/function claims do not require the FDA's prior approval but clinical trials of the disease treatment effects of HHF require prior approval from the FDA. In the USA, IRBs are managed by the Department of Health and Human Services (DHHS) rather than the FDA, and IRBs in those institutions which would execute the clinical trials requiring prior approval from the FDA or human studies funded by the USA federal government are required to be registered on the DHHS. In the UK, although the government does not require prior approval of human study, authorized RECs managed by the National Research Ethics Service (NRES) and other independent RECs review the human study. In Japan, human study for HFF must conform with "Ethical guidelines for epidemiological research" and IRB registration has not been required. In Korean domestic regulations, the responsibilities, compositions, functions and operations of IRBs on medicines, medical devices and biotechnology are legally specified, but not those of IRB on HHF. These foreign statuses for the management of human study on HFF and comparisons with Korean regulations are expected to be used as basic data to improve the domestic legal system.

Distributions of Hyperfine Parameters in Amorphous $Fe_{83}B_9Nb_7Cu_1$ Alloys (비정질 $Fe_{83}B_9Nb_7Cu_1$의 M$\)

  • 윤성현;김성백;김철성
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.271-277
    • /
    • 1999
  • Amorphous $Fe_{83}B_9Nb_7Cu_1$ alloy has been studied by M$\"{o}$ssbauer spectroscopy. Revised Vincze method was used and distributions of hyperfine field, isomer shift, and quadrupole line broadening of the sample at various temperatures have been evaluated and Curie temperature and $H_{hf}\;(0)$ were calculated to be 393 K and 231 kOe, respectively. Temperature variation of reduced average hyperfine field shows a flattered curvein comparison with the Brillouin curve for S=1. This behavior can be explained on the basis of Handrich molecular field model, in which the parameter Δ, which is a measure of fluctuation in exchange interactions, is assumed to have the temperature dependence ${Delta}=0.75-0.64{\tau}+0.47{\tau}^2$ where $\tau$ is $T/T_C$. At low temperature, the average hyperfine field can be fitted to $H_{hf}\;(T)=H_{hf}\;(0)\;[1-0.44\;(T/T_C)^{3/2}-0.28(T/T_C)^{5/2}-… ]$, which indicates the presence long wave length spin wave excitations. At temperature near TC, reduced average hyperfine field varies as $1.00\;[1-T/T_C]^{0.39}$. It is also found that half-width of the hyperfine field distribution was 102 kOe (3.29 mm/s) at 13 K and decreased monotonically as temperature increased. Above the Curie temperature, an average quadrupole splitting value of 0.43 mm/s was found. Average line broadening due to quadrupole splitting distribution was 0.31 mm/s at 13 K and decreases monotonically to 0.23 mm/s at 320 K, whereas that due to the isomer shift distribution is 0.1 mm/s at 13 K and 0.072 mm/s at 320 K, which is much smaller than that of both hyperfine field and quadrupole splitting. The temperature dependence of the isomer shift can be fitted within the harmonic approximation to a Deybe model with a Debye temperature ${Theta}_D=424{\pm}5K$.TEX>.

  • PDF