수열원 히트펌프 용 HFC32/HFC152a 혼합냉매의 성능평가 (Performance of HFC32/HFC152a Mixture for Water-source Heat Pumps)

  • 강동규;김욱진;정동수
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.391-400
    • /
    • 2012
  • In this study, performance of HFC32/HFC152a mixture is measured in the composition range of 20 to 50% R32 with an interval of 10% for the comparison with the conventional HCFC22 in water-source heat pumps. Tests are carried out under the same capacity in a heat pump bench tester equipped with a variable speed compressor at the evaporation and condensation temperatures of 7/$45^{\circ}C$ and -7/$41^{\circ}C$ for summer and winter conditions, respectively. Test results show that the compressor power of the HFC32/HFC152a mixture is 13.7% lower than that of HCFC22 while the coefficient of performance(COP) the HFC32/HFC152a mixture is 15.8% higher than that of HCFC22. Hence, from the view point of energy efficiency, the HFC32/HFC152a mixture is excellent as compared to HCFC22. Compressor discharge temperatures of HFC32/HFC152a mixture are increased up to $15.4^{\circ}C$ as compared to that of HCFC22. The amount of charge for HFC32/HFC152 mixture decrease up to 27% as compared to that of HCFC22. Overall, HFC32/ HFC152a mixture is an excellent long term candidate to replace HCFC22 in water-source heat pumps.

가스계 혼합소화약제의 불꽃소화농도 (Flame Extinguishing Concentrations of Mixed Gaseous Agents)

  • 김재덕;임종성;이윤우;이윤용
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.34-40
    • /
    • 2001
  • 가스계 혼합소화약제의 소화성능을 검토하기 위하여 Cup-burner test장치를 설치하고 이성분계 및 삼성분계 혼합물의 불꽃소화농도를 측정하였다. 시험대상 이성분계 혼합물은 이산화탄소/HFC-23, 이산화탄소/HCFC-22, 이산화탄소/HFC-227ea, 이산화탄소/HFC-125, 이산화탄소/FIC-13I1, Hexafluoropropylene/HFC-23이고 삼성분계 흔합물은 이산화탄소/HFC-237HFC-l34a, 이산화탄소/HFC-23/HFC-227ea, 이산화탄소/HFC-23/HFC-125이다. Cup-burner test장치에서 측정된 가스계 혼합물의 소화농도는 단일성분의 소화농도와 혼합물의 구성비로 이루어진 모델에 의해 잘 예측됨을 알 수 있었다. 특히 이 모델은 혼합물의 구성성분이 물리적 소화성능을 지닐 때 잘 적용되며 화학적 소화성능의 영향이 강해질수록 측정값과의 오차가 커진다.

  • PDF

고효율 수퍼히트펌프에 관한 전산 해석 (Computer Simulation of a Super-Heat Pump System)

  • 김학준;정동수;김종보;하경용
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.234-248
    • /
    • 1995
  • A super-heat pump system composed of a suction line heat exchanger, low and high stage economizers, and a screw compressor is simulated to examine the energy performance and design options. CFC12, HCFC22, HFC134a, HCFC22/HCFC142b, HFC32/HFC134a, and HFC125/HFC134a are used as working fluids for comparison. The results indicate that the proposed system charged with appropriate mixtures is up to 33.4% more energy efficient than the normal system with CFC12. The performance of the super-heat pump system charged with mixtures was influenced by such factors as the temperature matching, heat source temperature difference, low stage economizer, and high stage economizer. The fluids with a larger liquid specific heat such as HFC134a would have more benefits when a suction line heat exchanger is installed. 40%HCFC22/60%HCFC142b mixture seems to be a good candidate to replace CFC12. On the other hand, 25%HFC32/75% HFC134a would be a good long term candidate to replace HCFC22.

  • PDF

고압가스계 소화약제(HFCs계열)와 질소의 상호용해도 측정 (Measurement of Mutual Solubility of High-pressure Gaseous Fire Extinguishing Agents(HFCs) and Nitrogen)

  • 임종성;박지영;이병권;김재덕;이윤용
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.26-31
    • /
    • 2002
  • Bromotrifluoromethane(halon-1301)과 bromochlorodifluoromethane(halon-1211)은 우수한 열역학적 성질에 의해 소화제로 널리 사용되어 오고 있다. 그러나 halon-1301과 halon-1211의 사용과 생산은 국제 환경조약인 Montreal protocol에 의해 점차 사용이 중지되고 있으며, 본격적인 규제에 대한 대책 마련이 요구되는 시점에 있다. 그리하여, 할론 사용규제와 더불어 각국은 할론 소화제 대신 HFCs를 사용하는 방안이 제시되었으며, 이미 선진국에서는 다양한 종류의 소화제 개발을 발표하고 있다. 본 연구에서는 대체 소화제로서 소화제의 배출시간을 단축시켜주는 가압가스 nitrogen과 halon 대체 물질인 HFCs 계열 물질중 chlorodifluoromethane(HFC-22), pentafluoroethane(HFC-125), 1,1,1,2-tetrafluoroethane(HFC-l34a)을 선정하여 이들간의 이성분계 혼합물에 대한 상호 용해력을 알아보기 위해 상평형을 측정하였다. 상평형은 기-액 순환이 동시에 이루어지는 circultion type 장치에서 측정되었으며, 실험온도는 실제 소화제 저장탱크의 온도범위인 283.15-303.15K로 선정하였고, 압력범위는 이 온도범위에서 탱크에 걸릴 수 있는 최저압력과 최고압력보다 충분히 여유를 두어 3.0-10.0 MPa조건에서 실험하였다. 실험데이터는 Peng-Robinson 상태방정식 및 Wong-Sandler mixing rules을 사용하여 혼합물의 거동을 예측하였고, 이를 실험 결과와 비교 검토하였다.

이산화탄소, HFC-l34a, HCFC-22의 열역학적 상태량 계산 절차의 응용 (Application of Procedures to Calculate Thermodynamic Properties of Carbon Dioxide, HFC-l34a and HCFC-22)

  • 박형준;박경근
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.389-396
    • /
    • 2003
  • Systematic methods to calculate thermodynamic properties of carbon dioxide, HFC-l34a and HCFC-22 are presented. First, application of a basic method to identify the saturation state with given temperature or pressure is attempted and the feasibility of auxiliary equations is tested. Next, detailed procedures are suggested to tell a phase when temperature/pressure and another property are specified. Finally Newton-Raphson method is applied to calculate unknown thermodynamic properties fixing the state with the two independent properties specified. The procedures described here are utilized to develop a computer program, which is used to find the relation between temperature and pressure with maximum isobaric heat capacity for super-critical carbon dioxide.

HFC152a, HFC134a, 프로판을 포함한 자동차용 대체/보충 냉매의 성능 (Performance of HFC152a, HFC134a and HC290 Mixtures as Alternative Refrigerants for HFC134a)

  • 강남구;배근환;박기정;정동수
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.383-391
    • /
    • 2010
  • In this study, HFC152a, HFC134a/HFC152a and HC290/HFC134a/HFC152a mixtures are studied for the supplementary and alternative refrigerants for HFC134a used in automobile air-conditioners. Due to the high global warming potential of HFC134a, it has to be phased out in the long run. Thermodynamic performance of these refrigerants are measured in a bench tester of 3.5 kW capacity with an open type compressor under both summer and winter conditions. Test results show that the coefficient of performance (COP) and capacity of pure HFC152a and HFC134a/HFC152a mixture are 9.1~12% and 7% higher than those of HFC134a. As for the HC290/HFC134a/HFC152a, the COP is up to 9.5% higher than that of HFC134a with 1~2% of HC290 while that is up to 6.1% lower than that of HFC134a with 5% HC290. The capacity of the ternary mixture, however, is 8.6% higher than that of HFC134a at all compositions tested. The compressor discharge temperatures of all refrigerants tested are $6{\sim}10^{\circ}C$ higher than that of HFC134a. For all refrigerants, the amount of charge is reduced up to 32% due to the decrease in liquid density. Overall, these refrigerants provide good performance with reasonable energy savings with less environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

고압상태의 다양한 용매 내에서 Poly(methylmethacrylate) (PMMA)의 상거동 (Phase Behavior of Poly(methylmethacrylate) (PMMA) in Varions Solvents at High Pressure)

  • 김제일;유기풍;임종성
    • 청정기술
    • /
    • 제13권1호
    • /
    • pp.28-33
    • /
    • 2007
  • 본 연구에서는 variable volume view cell이 장착된 상평형 장치를 사용하여 고압 상태의 다양한 용매 내에서 고분자인 Poly(methylmethacrylate) (PMMA)의 구름점(cloud point)를 측정하였다. 이때 사용된 용매는 chlorodifluoromethane (HCFC-22), dimethylether (DME), 1,1,1-trifluoroethane (HFC-143a), 1,1-difluoroethane (HFC-152a), 1,1,1,2-tetrafluoroethane (HFC-134a) 이였으며, 이들 용매에 $CO_2$를 첨가한 $HCFC-22+CO_2$$DME+CO_2$의 이성분계 혼합용매에서 $CO_2$의 조성 변화가 PMMA의 상거동에 미치는 영향을 살펴보았다. 실험 결과 PMMA는 HCFC-22에서는 340K, 5MPa 정도의 가장 낮은 온도 압력 조건에서부터 잘 용해되었으며 DME에서는 300K, 28MPa 정도의 비교적 낮은 온도 압력 범위에서 잘 용해되었으나, 그 밖의 불소화합물인 HFC-143a, HFC-152a, HFC-134a에서는 423.15K, 160MPa의 높은 온도 및 압력범위에서도 전혀 용해가 일어나지 않았다. 또한, PMMA+HCFC-22 혼합물에 $CO_2$를 첨가한 $PMMA+HCFC-22+CO_2$계의 경우는 LCST (lower critical solution temperature)의 상거동을 보였으나 PMMA+DME 혼합물에 $CO_2$를 첨가한 $PMMA+DME+CO_2$계의 경우는 UCST (upper critical solution temperature)의 상거동을 보였다. $CO_2$ 혼합용매 내에서 cloud point 압력은 동일한 온도에서 첨가되는 $CO_2$의 양에 비례하여 급격히 높아지는 것을 관찰할 수 있었고, 이로부터 PMMA를 SAS (supercritical antisolvent) 법에 의해 미세입자화 할 경우 $CO_2$가 DME와 HCFC-22에 대한 역용매로 사용될 수 있다는 것을 확인할 수 있었다. 또한 $CO_2$의 농도를 변화시킴으로써 PMMA의 cloud point를 자유롭게 조절할 수 있다는 것을 알 수 있었다.

  • PDF

황기홍국소스를 처리한 계육이 고지방 및 고콜레스테롤 식이 흰쥐의 체중과 혈청 및 간 조직의 지질 함량에 미치는 영향 (Effects of Chicken Treated with Hwangki-Beni Koji Sauces on Body Weight, Serum and Hepatic Lipid Profiles of Rats Fed High Fat and High Cholesterol Diets)

  • 김재원;김순동;윤광섭
    • 한국식품영양과학회지
    • /
    • 제39권9호
    • /
    • pp.1270-1278
    • /
    • 2010
  • 황기열수추출물(WEH)과 홍국 70% 에탄올추출물(EEB) 및 Monascus pilosus 액침배양액(LBK)을 동결건조한 등량 혼합물을 일반 베이스소스에 0.225% 혼합한 황기홍국소스(HBS)에 침지한 계육의 식이가 고지방-고콜레스테롤 병행식이 흰쥐의 체중, 장기중량, 혈청지질 함량에 미치는 영향을 조사하였다. 실험군은 정상군(NC), 고지방-고콜레스테롤 대조군(HFC), 고지방-고콜레스테롤 식이에 베이스소스를 처리한 계육을 15% 첨가한 식이군(HFC-BS) 및 고지방-고콜레스테롤 식이에 황기홍국소스를 처리한 계육을 15% 첨가한 식이군(HFC-HBS)으로 구분하여(5 마리/군) 5주간 사육하였다. 식이섭취량은 HFC-HBS군이 HFC 및 HFCBS군에 비하여 높았으나 식이효율과 사육후의 체중은 낮아 체중감소효과가 확인되었다. ALT 및 AST의 활성도 정상군에는 미치지 못하나 HFC군 및 HFC-BS군에 비하여 현저한 감소를 보였다. HFC-HBS군은 HFC-BS군에 비하여 혈청 triglyceride 함량은 34.06%, total cholesterol 함량은 6.28% 및 LDL-cholesterol 함량은 31.00%가 감소하였으며 HDL-cholesterol 함량은 1.72배 증가되었고 동맥경화지수는 2.52배 감소하였다. 간 조직의 총 지질, 중성지질 및 총콜레스테롤 함량도 HFC-HBS군이 HFC-BS군에 비하여 각각 9.53%, 5.25% 및 22.20%가 감소되었다. NC군은 정상적인 간 조직구조를 나타낸 반면 HFC군은 거의 모든 간세포가 multiple micro vesicles 형태의 지방을 함유하는 것으로 나타났다. 또한 HFC-BS군에서는 HFC군과 비교해 볼 때 소적형 지방축적은 감소되었으나 염증세포와 쿠퍼세포가 활성화된 모습을 보인 반면 HFC-HBS군은 HFC-BS군과 비교해 볼 때 간 실질세포 내 지방들은 아주 작은 포말형으로 나타나며 정상적인 간 실질세포의 형태가 잘 나타나 고지방-고콜레스테롤 식이로 인한 간세포 손상을 크게 완화시킨 것으로 사료된다.

동북아시아 지역에서의 공기괴별 HFC-23/HCFC-22의 배출특성 (Emission Characteristics of HFC-23 (CHF3)/HCFC-22 (CHClF2) between Different Air Masses in Northeastern Asia)

  • 리선란;김주일;김경렬
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.490-498
    • /
    • 2010
  • HCFC-22 (chlorodifluoromethane, $CHClF_2$), one of the major components in various refrigeration, is emitted mostly from developing countries, as its consumption is not limited until 2013 by the Montreal Protocol. In addition, HFC-23 (trifluoromethane, $CHF_3$), a by-product in the manufacture of HCFC-22, is also a powerful greenhouse gas. Here, we discuss the regional emission characteristics of these compounds based on high-frequency in-situ measurements using the "Medusa" GC-MS system. HCFC-22 and HFC-23 baseline concentrations measured at Gosan (Jeju Island, Korea) from November 2007 to December 2008 increased by 1.8 ppt/yr and 0.6 ppt/yr, respectively. Pollution events of these compounds were observed, very frequently (e.g., ~2~3 times) at Gosan than baseline levels. All the measurement data were divided into four groups by simultaneously considering the ratio (HFC-23/HCFC-22) and concentration (HCFC-22) at Trinidad Head (TH, California, USA). The residence time of trajectories were then analyzed in each of the four groups. The results exhibited the existence of a strong correlation with air mass origin for each group: 1) Air masses originating from Siberia in the north and from the Pacific in the south had ratios of 0.08~0.12 and concentrations of 196.9~254.3 ppt which is highly comparable to background air at TH. 2) Air masses passing over the Southern China exhibited similar ratios but higher HCFC-22 concentrations. 3) Air masses passing over the Northern China had ratios of 0.12~0.21. 4) Air masses passing over Korea and/or Japan had ratios of 0.01~0.08. Our results suggest that the HFC-23/HCFC-22 ratio can be used as a good indicator for the assessment of the pollution with Chinese origin. We also confirmed differences in air masses traveling over Northern and Southern China, most likely due to differences in air mass travelling speed over these regions before arriving at Gosan. This signature may be treated as one of the critical components in identifying the emission sources from different parts of China.

R32를 포함한 R22 대체 혼합냉매의 모세관 유동 특성 (Flow Characteristics of Refrigerant Mixtures with R32 in a Capillary Tube)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.177-186
    • /
    • 1996
  • The characteristics of the flow of pure HFC refrigerants(R32, R125, and R134a) and their mixtures through capillary tubes were investigated experimentally. Two capillary tubes with 1.2mm and 1.6mm inner diameter and 1.5m length were adopted as test sections. Mass flow rates and temperatures and pressures were measured for several condensing temperatures and degrees of subcooling at capillary tube inlet. The effects of the condensing temperature, inner diameter of capillary tube, and subcooling on the mass flow rate of refrigerants were discussed, and the mass flow rates of HFC refrigerants were compared with that of R22. The pressure and temperature distributions along the capillary tube compared with that of R22. The pressure and temperature distributions along the capillary tube show that there is a metastable equilibrium state in the flow through the tube. Underpressure for vaporization increases as refrigerant mass flux increases and inlet subcooling decreases. Empirical correlation was suggested to predict underpressure for vaporization of the HFC refrigerants.