• Title/Summary/Keyword: HEXA

Search Result 158, Processing Time 0.023 seconds

The effect of hexamethylenetetramine contents and cure properties on friction characteristics of phenolic resin (페놀수지의 마찰특성에 미치는 HEXA의 함량 및 경화도의 영향)

  • Kim, Dae-Kyeun;Jang, Ho;Yoon, Ho-Gyu
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.49-56
    • /
    • 1999
  • A material was formulated with Phenol novolac and HEXA only. The cure kinetics and thermal characteristics of phenol novolac with various HEXA contents were peformed by differential scanning calorimetry and thermal gravimetric analysis. All kinetic parameters of the curing reaction including the reaction order, activation energy, and rate constant were calculated and reported. The results indicate that the curing reaction goes through an autocatalytic kinetic mechanism. The friction and wear characteristics of this material were determined using friction material testing machine. The friction coefficient of phenol novolac with various HEXA contents was determined using the PV(pressure & velocity) factor. The most stable and highest friction coefficient with a various pressure and velocity condition was found at HEXA 10 wt.% material. The specific wear rate per unit sliding distance with a various HEXA contents was reported.

  • PDF

Catalytic Decomposition of SF6 from Semiconductor Manufacturing Process (촉매를 이용한 반도체 공정 SF6 처리에 관한 연구)

  • Hwang, Cheol-Won;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.1019-1027
    • /
    • 2013
  • Sulfur hexa-fluoride has been used as a etching gas in semiconductor industry. From the globally environmental issues, it is urgent to control the emissions of this significant greenhouse gas. The main objective of this experimental investigation was to find the effective catalyst for $SF_6$ decomposition. The precursor catalyst of hexa-aluminate was prepared to investigate the catalytic activity and stability. The precursor catalyst of hexa-aluminate was modified with Ni to enhance the catalytic activities and stability. The catalytic activity for $SF_6$ decomposition increased by the addition of Ni and maximized at 6wt% addition of Ni. The addition of 6wt% Ni in precursor catalyst of hexa-aluminate improved the resistant to the HF and reduced the crystallization and phase transition of catalyst.

Evaluation of the accuracy of the HexaPOD evo RT system using Non-coplanar beams in lung cancer (폐암환자의 비동일평면 선속 빔 치료 시 HexaPOD evo RT system 의 정확성 평가)

  • Jang, Sewuk;cho, Kangchul;Lee, Sangkyoo;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2015
  • Purpose : The aim of this study, evaluate the accuracy of HeaxPOD evo RT system using the non-coplanar beam. Materials and Methods : 13 treatment plans are used which applied non-coplanar beams and 10 treatment plans which coplanar beams are used. the correction value what adjust to 6D couch is determined by each patient's setup errors only rotation direction. The study executed followings. first, Applying the correction value, measure the point dose and calculate the ${\gamma}$-index(${\gamma}=3%$ / 3 mm, ${\gamma}=2%$ / 2 mm). second, acquire data as previous methods without correction by HexaPOD. Results : For comparing the two results, we find out the more precise applying HexaPOD by point dose 0.2% in coplanar and non-coplanar. in the case of ${\gamma}$-index<1(${\gamma}=3%$ / 3 mm), more precise 2.2% in coplanar and 7% in Non-coplanar. Particularly, ${\gamma}$-index<1(2% / 2 mm) show the difference 9.2% in coplanar and 15.1% non-coplanar between apply HexaPOD and dose not apply HexaPOD. Conclusion : Using the HexaPOD is more precise than without HexaPOD. It suggests that HexaPOD evo RT system is very useful for precise and high dose delivery.

  • PDF

Friction and Wear Characteristics of Friction Material with the Content of Hexamethylenetetramine (Hexamethylenetetramine의 함량에 따른 마찰재의 마찰.마모 특성)

  • Kim, Dae-Kyeun;Jang, Ho;Yoon, Ho-Gyu
    • Tribology and Lubricants
    • /
    • v.16 no.4
    • /
    • pp.266-273
    • /
    • 2000
  • The friction characteristics of phenolic resin and model friction materials were investigated with the content of hexamethylenetetamine (HEXA). At 10 wt.% of HEXA, the phenolic resin and model friction materials showed the most stable friction coeffcient in constant temperature test at various test conditions because of its good thermal stability and proper curing reaction. It was found from constant interval test in mild condition that the friction coeffcients of friction materials cured with 10 wt.% of HEXA was the highest and stable values in the whole range of braking operations. However, at the severe condition in constant interval test, the friction coefficient of friction materials cured with 10 wt.% to of HEXA was lowered and as the number of braking operation increased, the values became stable. In order to obtain the thormal stable friction materials, the content of HEXA from 5 to 10 wt.% could be recommended.

The Health Examinees (HEXA) Study: Rationale, Study Design and Baseline Characteristics

  • Health Examinees (HEXA) Study Group
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1591-1597
    • /
    • 2015
  • Background: Korea has experienced rapid economic development in a very short period of time. A mixture of traditional and modern risk factors coexists and the rapid change in non-genetic factors interacts with genetic constituents. With consideration of these unique aspects of Korean society, a large-scale genomic cohort study-the Health Examinees (HEXA) Study-has been conducted to investigate epidemiologic characteristics, genomic features, and gene-environment interactions of major chronic diseases including cancer in the Korean population. Materials and Methods: Following a standardized study protocol, the subjects were prospectively recruited from 38 health examination centers and training hospitals throughout the country. An interview-based questionnaire survey was conducted to collect information on socio-demographic characteristics, medical history, medication usage, family history, lifestyle factors, diet, physical activity, and reproductive factors for women. Various biological specimens (i.e., plasma, serum, buffy coat, blood cells, genomic DNA, and urine) were collected for biorepository according to the standardized protocol. Skilled medical staff also performed physical examinations. Results: Between 2004 and 2013, a total of 167,169 subjects aged 40-69 years were recruited for the HEXA study. Participants are being followed up utilizing active and passive methods. The first wave of active follow-up began in 2012 and it will be continued until 2015. The principal purpose of passive follow-up is based on data linkages with the National Death Certificate, the National Cancer Registry, and the National Health Insurance Claim data. Conclusions: The HEXA study will render an opportunity to investigate biomarkers of early health index and the chronological changes associated with chronic diseases.

Implementation of Low Loss Radome with Hexa mesh for Ku-Band

  • Seo, Kang;JeongJin, Kang
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.555-560
    • /
    • 2022
  • In this study, the insertion loss and phase delay according to the multi-layer structure radome parameters were analyzed using the boundary value solution approach, and the multi-layer structure and hexa mesh structures with low-loss electrical characteristics for the Ku-band transmission/reception frequency of 10.7 ~ 14.5 GHz were designed and manufactured. A hexa mesh was applied to minimize radio wave transmission and scattering, which lowered the transmittance refractive index according to the radio incident angle and minimized dielectric loss through high-density foam. Similar to the simulation result, the transmission loss obtained the gain in a specific receiving frequency band, and in the transmission frequency band, an excellent low loss characteristic was obtained with an insertion loss of 0.8dB or less. The results of this study can be used in radio transmission radomes of low-weight, low-cost end-system protection devices.

Robust Adaptive Control of A HexaSlide Type Parallel Manipulator

  • Kim, Jong-Phil;Kim, Sung-Gaun;Ryu, Jeha
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.4
    • /
    • pp.262-267
    • /
    • 2001
  • Jeha Ryu Department of Mechatronics, Kwangju Institute of Science and Technology This paper presents an application of a robust adaptive control strategy to HexaSlide type six degrees-of-freedom parallel manipulators. The HexaSlide type parallel manipulators are characterized as an architecture with constant link lengths that are attached to moving sliders on the ground and to a mobile platform. The proposed control law is developed based on a simplified second order system dynamic equation in joint space with uncertain mass, damper, spring, and Coulomb friction terms. These uncertain parameters are updated by an adaptation law that is derived by Lyapunov stability theorem. A robust adaptive control law by using the boundary layer is designed for the purpose of compensating for the neglected dynamic effects of the mobile platform and the six moving links that are modeled as a disturbance term. Experimental results show good and fast tracking performance.

  • PDF

Derivation of Linearized Dynamic Equations of Motion for HexaSlide Type Parallel Manipulators (6 자유도 HexaSlide 형 병렬기구의 선형화된 운동방정식 유도)

  • Kim, Jong-Phil;Ryu, Je-Ha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.743-750
    • /
    • 2000
  • This paper presents an equivalent linearization method and application to the equations of motion of a 6 degree-of-freedom PRRS HexaSlide type parallel manipulators which are characterized as the architecture with constant link lengths that are attached to moving sliders on the ground and to a mobile platform. Since dynamic equations of parallel manipulators are complicated and highly nonlinear, control bandwidth, adjustable control gain as well as vibration characteristics cannot be easily found. The proposed equivalent linearization method can be applied over specified workspace as well as on a path of mobile platform. Through an equivalent linearization method, one can easily get a simple linear dynamic model. This linearized dynamic model may be utilized in a simplified computed torque control strategy.

  • PDF

PRELIMINARY STUDY ON THE DESIGN OF IMPLANT ABUTMENT SCREW HEAD FOR RAPID FASTENING & LOOSENING (임플랜트 유지 나사 머리 홈의 설계가 나사를 푸는 시간에 미치는 영향에 관한 연구)

  • Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.193-200
    • /
    • 2002
  • For the purpose of decreasing the chair time in implant cases, the time needed to loosening and fastening the screw must be shortened. Nowadays, the two typical designs of screw head are slot and hexa form. This study aimed at the shortening of loosening and fastening time by modifying the slot and hexa form. Total of twelve dentists participate in these experiments, four of them were experienced and eight of them were novice dentists. 1. There were many differences in the speeds of screw loosening and fastening between personal experiences. Experienced dentists are faster than novice dentists. 2. There were many differences in the speeds by angulation of the implant, by the conditions of the muscle tonicity. 3. Revised slot and hexa Heads show the slightly shortened time for acrew looseing and fastening.

Feature, Problem find the Hereafter of Chrome-Containing Refractory (크롬계 내화물의 특징과 문제점 및 장래)

  • Yamaguchi, Akira
    • Ceramist
    • /
    • v.9 no.6
    • /
    • pp.12-17
    • /
    • 2006
  • One of characteristic of $Cr_2O_3-containing$ refractory is excellent resistance to corrosion. However, there is a problem that hexa-valent chromium, which is noxious to the human body, is easily formed by reaction between the refractory and slag with CaO, $Na_2O$ and/or $K_2O$. In this article, the reason why the $Cr_2O_3-containing$ refractory has excellent corrosion resistance qualities, he conditions under which hexa-valent chromium formed, methods for suppressing generation of hexa-valent chromium and the possibility of the refractory components excluding $Cr_2O_3$ for the furnace are described as a base of development of further excellent refractories.

  • PDF