• Title/Summary/Keyword: HEPA Filter

Search Result 55, Processing Time 0.028 seconds

Design of a HEAP Filter Assembly for Air-Filter in Nuclear Power Plant (원자력 발전소 공기 조화용 HEPA 필터 설계)

  • Park, Jong-Beom;Kwon, Tae-Jong;Moon, Ki-Won;Lee, Se-Yup
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.781-783
    • /
    • 2000
  • In developing the assemble HEPA(High Efficiency Particulate Air) Filter, the main frame and sub frame can be easily assembled and disassembled and tightly sealed. The sub frame(included Media) will be made of the manageable material. so it will be easily compacted with the spent filter compactor. It does not take a lot of time for disassembling the spent filter. The main frame can be recycled and the volume of the spent filter is reduced, so the cost for treating the radioactive waste is reduce. And the changing costs can be reduced, because the cost of the media is lower than the filter.

  • PDF

Changes in microbial phase by period after hepa filter replacement in King oyster(Pleurotus eryngii) mushroom cultivation (큰느타리 재배사에서 헤파필터 교체 이후 기간에 따른 미생물상 변화)

  • Park, Hye-Sung;Min, Gyong-Jin;Lee, Eun-Ji;Lee, Chan-Jung
    • Journal of Mushroom
    • /
    • v.18 no.4
    • /
    • pp.398-402
    • /
    • 2020
  • This study was conducted to set up a proper replacement cycle of High Efficiency Particulate Air (HEPA) filters by observing the microbial populations in the air of the cultivation house of Pleurotus eryngii, before and after HEPA filter replacement at different periods. The density of bacteria and fungi in the air during each cultivation stage was measured using a sampler before the replacement of the HEPA filter. The results showed that airborne microorganisms had the highest density in the mushroom medium preparation room, with 169.7 CFU/㎥ of bacteria and 570 CFU/㎥ of fungi, and the removed old spaun had 126.3 CFU/㎥ of bacteria and 560 CFU/㎥ of fungi. The density of bacteria and fungi in the air at each cultivation stage before the replacement of the HEPA filter was 169.7 CFU/㎥ and 570 CFU/㎥, and 126.3 CFU/㎥ and 560 CFU/㎥, during the medium production and harvesting processes, respectively. After the replacement of the HEPA filter, the bacterial density was the lowest in the incubation room and the fungal density was the lowest in the cooling room. The microbial populations isolated at each period consisted of seven genera and seven species before the replacement, including Cladosporium sp., six genera and six species after 1 month of replacement, including Penicillium sp., 5 genera and 7 species after 3 months of replacement, including Mucor plumbeus, and 5 genera and 12 species, 5 genera and 10 species, and 5 genera and 10 species, 4, 5, and 6 months after the replacement, respectively, including Penicillium brevicompactum. During the period after replacement, the species were diversified and their number increased. The density of airborne microorganisms decreased drastically after the replacement of the HEPA filter. Its lowest value was recorded after 2 months of replacement, and it increased gradually afterwards, reaching a level similar to or higher than that of the pre-replacement period. Therefore, it was concluded that replacing the HEPA filter every 6 months is effective for reducing contamination.

Numerical analysis on the inner flow characteristic for small smoke collector (소형 흡연집진기 내부 유동특성에 관한 수치해석)

  • Jang, Sung Cheol;Woong, Kim Jae;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.67-75
    • /
    • 2013
  • This study is flow analysis on the smoke collector in smoking room. The smoke collector for improving impure air at smoking area is analyzed and the inner flow filed in smoke collector is confirmed on the study result. The velocity with pressure distribution according to suction flow rate at filter entrance is also compared. Pressure characteristic and pressure resistance coefficient are analyzed according to flow analysis result for each other filter. The pressure drop of about 15 Pa occurs at the normal driving mode to strainer inlet from HEPA filter outlet. On the other hand, the pressure drop about 44% increases at turbo mode.

Performance of the Exhaust Filtration System of Hot Cell at PIEF (조사후시험시설에서의 핫셀 배기포집시스템의 성능평가)

  • Hwang, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

Mold Occurring on the Air Cleaner High-Efficiency Particulate Air Filters Used in the Houses of Child Patients with Atopic Dermatitis

  • Kim, Seong Hwan;Ahn, Geum Ran;Son, Seung Yeol;Bae, Gwi-Nam;Yun, Yeo Hong
    • Mycobiology
    • /
    • v.42 no.3
    • /
    • pp.286-290
    • /
    • 2014
  • Fungi are the known sources of irritation associated with atopic diseases (e.g., asthma, allergic rhinoconjunctivitis, and atopic eczema). To quantitatively estimate their presence in the indoor environment of atopic dermatitis-inflicted child patient's houses (ADCPHs), the high-efficiency particulate air (HEPA) filters installed inside the air cleaners of three different ADCPHs were investigated for the presence of mold. The air cleaner HEPA filters obtained from the three different ADCPHs were coded as HEPA-A, -B, and -C, respectively, and tested for the presence of mold. The colony forming units (CFUs) corresponding to the HEPA-A, -B, and -C filters were estimated to be $6.51{\times}10^2{\pm}1.50{\times}10^2CFU/cm^2$, $8.72{\times}10^2{\pm}1.69{\times}10^2CFU/cm^2$, and $9.71{\times}10^2{\pm}1.35{\times}10^2CFU/cm^2$, respectively. Aspergillus, Penicillium, Alternaria, Cladosporium, Trichoderma, and other fungal groups were detected in the 2,494 isolates. The distribution of these fungal groups differed among the three filters. Cladosporium was the major fungal group in filters HEPA-A and -C, whereas Penicillium was the major fungal group in the filter HEPA-B. Nine fungal species, including some of the known allergenic species, were identified in these isolates. Cladosporium cladosporioides was the most common mold among all the three filters. This is the first report on the presence of fungi in the air cleaner HEPA filters from ADCPHs in Korea.

방사성환기설비 운전에 있어서의 부압변동 요인 및 대응 방안

  • 이강무;이범철;이영희;김태국;손종식;홍권표;김홍태
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.334-335
    • /
    • 2004
  • It is important that the contaminated air is not revealed to the outside of the facility. The inside of the facility should be classified into several zones according to the radioactivity and each zone should maintain tile differential negative pressure between the zones also. It is not easy to equilibrate the pressure during the operation. On the normal operation, the clogging of the HEPA filter and the opening of the doors/shutters influence very much. We could maintain the differential negative pressure between the zones by the constant watching and periodical replacement of the filters.

  • PDF

Flow Simulation of Chamber System to Obtain Particle Uniformity and Study on Bio-aerosol Reduction Test (입자 균등성 확보를 위한 시험 챔버의 유동 시뮬레이션 및 이를 이용한 기상 부유균 저감 특성의 실험적 연구)

  • Park, Dae-Hoon;Hyun, Junho;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.10 no.2
    • /
    • pp.83-91
    • /
    • 2014
  • Since airborne bacteria have been known to aggravate indoor air quality, studies on reducing bacteria particles increase recently. In this study, a chamber(0.8m x 0.8m x 1.56m) system was built in order to simulate real conditions for reducing airborne bacteria, and evaluated by a simple aerosol reduction test. A method utilizing CFD(Computational Fluid Dynamics) simulation was used to detect the horizontal cross-sectional area which represents particle distribution in the chamber. Then an air-cleaner with HEPA filter and Carbon Fiber Ionizer was located on that area for aerosol reduction test. The CFD result found the area was located at 0.2m height from the bottom of the chamber, and the test showed aerosol reduction efficiencies using measurements of number concentration and CFU(colony forming unit) per each case. At the measurement of number concentration, the reduction efficiency of air-cleaner with filter and ionizer(Case 3) was about 90% after 4 minutes from the stop of the bacteria injection, and that with only filter(Case 2) was about 90% after 8 minutes from the beginning. Lastly, that without filter and ionizer(Case 1) was about 30% after 10 minutes. At the measurement of CFU, it shows similar results but it is related to viability of bio-aerosol.