• Title/Summary/Keyword: HEART RATE

Search Result 3,363, Processing Time 0.038 seconds

Clinical Results of Mitral Valvular Surgery in Patients with Moderate Ischemic Mitral Regurgitation Undergoing Coronary Artery Bypass Grafting (중등도의 허혈성 승모판막 폐쇄부전 환자의 관상동맥 우회로 조성술 시 승모판막 수술의 유무에 따른 원상 결과)

  • Yu Song-Hyeon;Chang Byung-Chul;Yoo Kyung-Jong;Kang Meyun-Shick;Hong You-Sun
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.611-618
    • /
    • 2006
  • Background: There have been controversies whether mitral valvular surgery is necessary in the patients with moderate ischemic mitral regurgitation undergoing coronary artery bypass grafting. The purpose of this study is to evaluate the long term clinical results of patients with moderate ischemic mitral regurgitation. Material and Method: Between January 1992 and February 2005, 44 patients with moderate ischemic mitral regurgitation underwent coronary artery bypass grafting. Concomitant mitral valvular procedure was performed in 20 patients (group 1) and isolated coronary artery bypass grafting was performed in 24 patients (group 2). There were no significant difference between groups except cardiopulmonary bypass time (p<0.01). Postoperative follow up duration was $30.1{\pm}29.6$ months and last follow up echocardiographic examination was performed at $21.2{\pm}28.0$ months. Result: There was no difference in operative mortality between groups (group 1 vs group 2, 15.0% vs 8.3%, p=0.493). Grade of mitral regurgitation ${(0.81{\pm}0.91\;vs\;1.50{\pm}0.05,\;p=0.046)}$ and reduction in regurgitation grade ${(1.75{\pm}0.93\;vs\;0.70{\pm}1.26,\;p=0.009)}$ were different between two groups. But there were no significant differences in left ventricular ejection fraction ${(34.1{\pm}11.4%\;vs\;41.6{\pm}12.9%)}$, left ventricular end systolic volume ${(118.2{\pm}63.9\;ml%\;vs\;85.6{\pm}281\;ml)}$, New York Heart Association functional class ${(2.1{\pm}0.2\;vs\;2.4{\pm}1.2)}$ and 5 year survival rate ${(85{\pm}8%\;vs\;82{\pm}8%)}$. There was no risk factor for operative mortality and the only risk factor for late death was preoperative atrial fibrillation (p=0.042). There was no significant correlation between mitral valvular surgery and late death. Conclusion: Concomitant mitral valvular procedure in patients with moderate ischemic mitral regurgitation undergoing coronary artery bypass grafting had no significant positive effect on survival and ventricular function compared with isolated coronary artery bypass grafting. Prospective randomized study may be needed to evaluate the necessity of concomitant mitral procedure and to find more effective method for the improvement of ventricular function.

Interrelationships and Differences of Brachial-Ankle Pulse Wave Velocity (baPWV), Body Composition and Cardiovascular Variables between Genders Who Have Been Exercised or Not in Elderly (운동참여 여부와 성별에 따른 노인의 맥박파전파속도, 신체구성과 심혈관계 변인의 상관성 및 재변인의 차이)

  • Lee, Jong-Woo;Kim, Dae-Sik;Cho, Eun-Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.378-387
    • /
    • 2016
  • This study sought to investigate interrelationships and differences of brachial-ankle pulse wave velocity (baPWV), body composition and cardiovascular variables between genders who have been exercised or not in elderly. One hundred fifty participants were classified four groups. Especially out of variables, in male elderly group who had participated in exercise program the PWV range were significantly correlated with muscle mass (r=0.357, p=0.026), SBP (r=0.468, p=0.003), right baPWV (r=0.406, p=0.010), and left baPWV (r=0.333, p=0.038). In male elderly group who had not participated in exercise program, the PWV range were significantly correlated with heart rate (r=0.395, p=0.014), right baPWV (r=0.598, p=0.000), and left baPWV (r=0.602, p=0.000). In female elderly group who had participated in exercise program, the PWV range were significantly correlated with name of diagnosis (r=0.321, p=0.044), SBP (r=0.399, p=0.011), DBP (r=0.545, p=0.000), right baPWV (r=0.648, p=0.000), and left baPWV (r=0.676, p=0.000). In female elderly group who had not participated in exercise program, the PWV range were significantly correlated with age (r=0.471, p=0.003), right baPWV (r=0.836, p=0.000), and left baPWV (r=0.801, p=0.000). The PWV among four groups were not significant different after experiment. However, there were significant differences in the waist/hip ratio (F=9.197, p=0.000), muscle mass (F=74.295, p=0.000), and %fat (F=35.045, p=0.000) from body composition. And there were significant differences in the SBP (F=3.525, p=0.017) after experiment. In conclusion, these data show that regular exercise is associated with arterial compliance (PWV range, right or left PWV) and differed from genders. In other words, this paper may support the concept that regular exercise program may exert a protective effect on arterial compliance, body composition and cardiovascular systems.

Effect of Self-Myofascial Release on Body Composition, Vascular and Metabolic Functions in Obese Female College Students (자가근막이완 운동이 비만 여자대학생의 신체조성과 혈관 및 대사기능에 미치는 효과)

  • Lee, Jae-Hoon;Kim, Ji-Sun;Oh, Yoo-Seong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.769-777
    • /
    • 2020
  • The purpose of this study was to investigate the effects of 8 weeks Self-Myofascial Release exercise on body composition, vascular and metabolic functions in obese female college students. The subjects were 19 obese female college students (n = 9) who were randomly assigned to an exercise group(n=9) and control group(n=9), with an exception of except 1 abandonment. The Self-Myofascial Release exercise group performed exercises twice a week for 8 weeks and for 40 minutes at one time using a foam roller, and the control group maintained normal life pattern for the same period. Body composition was measured by body weight, body fat percentage, vascular function was measured by pulse wave velocity(PWV), augmentation index(AIx), brachial artery vascular flow-mediated dilation(FMD), and metabolic function was measured by fasting glucose and triglyceride levels. The Self-Myofascial Release exercise with foam roller showed no significant effect on body weight and body fat percentage. The Self-Myofascial Release exercise with foam roller showed no significant effect on heart rate, FMD, PWV but, SBP, CSBP and AIx were significant decreased. The Self-Myofascial Release exercise with foam roller showed no significant effect on fasting glucose and triglyceride levels. In conclusion, 8-week Self-Myofascial Release exercise for obese female college students showed no significant effect on body composition and metabolic function, but improved SBP, CSBP and AIx levels significantly. Therefore, Self-Myofascial Release exercise will be an effective way to improve the vascular function of obese female college students.

Early Clinical Outcome and Doppley Echocardiographic Data after Cardiac Valve Replacement with the ATS prosthesis (ATS 인공 판막의 조기 임상성적 및 도플러 심에코 검사 소견)

  • 박계현;박승우
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.663-669
    • /
    • 1997
  • This is a report on the clinical outcome and hemodynamic profile of the ATSwcardiac valve prosthesis, which is a recently introduced pyrolytic carbon bileaflet prosthesis. We retrospectively reviewed the early outcome of 100 consecutive patients who underwent isolated cardiac valve replacement with the ATS(w prosthesis from October 1994 through June 1996 at our hospital. All patients were evaluated with Doppler echocardiography before discharge from the hospital. The mean age of the patients was 48.6 years(range: 2 to 74). A tota of 124 prosthesis were implanted; 71 mitral, 46 aortic, and 7 tricuspid. The two most frequently used sizes were 27 mm(40.8%) and 29 mm(35.2%) in the mitral position, and 23 mm(30.4%) and 21 mm(28.3%) in the aortic position. There was no early or late death. The total follow-up period was 950 patient-months with 99% follow-up rate. Serious late morbidity occurred in three patients; reoperation in two patients for late rupture of Sinus of Valsava in one and for endocarditis with prosthetic dehiscence in the other, and intracranial hemorrhage due to hypertension in one patient. There has been no thromboembolic complication or structural valval deterioration. In the mitral position, the average values of peak and mean transprosthetic pressure gradients and valve area calculated from pressure half time were 6.9$\pm$2.8 mmHg, 2.6$\pm$ 1.5 mmHg, and 2.7 $\pm$0.8 cm2 respectively. In the aortic position, the peak and mean pressure gradients'were 26.4 $\pm$ 15.9 mmHg and 14.2 $\pm$ 7.9 mmHg. For the mitra prostheses larger than 25-mm size, there was no significant difference among prosthetic sizes in terms of transprosthetic gradients, whereas there was a significant negative correlation between the prosthesis size and the transprosthetic gradients for the aortic valves. The peak and mean Pressere pradients were 52.2 $\pm$ 17.6 tmHg and 26.9$\pm$ 7.4 mmHg across the 19-mm aortic Prostheses, and 27.1 $\pm$ 11.9 mmHg and 13.3$\pm$6.6 mmHg across the 21-mm size. Above results can lead to the conclusion that the early clinical outcome of the ATS valve prosthesis is quite satisfactory, And the hemodynamic characteristics are comparable, if not better, with other bileaflet prostheses.

  • PDF

Effects of Aqua-Acupuncture of Carthami Flos(GV15) on the Changes of Cerebral Hemodynamics in Rats (아문(瘂門)(GV15)의 홍화약침(紅花藥針)이 백서(白鼠)의 뇌혈류역학(腦血流力學) 변동(變動)에 미치는 영향(影響))

  • Ahn, Young-sun;Wei, Tung-shuen;Cho, Myung-rae;Chae, Woo-seok;Yun, Yeo-choong
    • Journal of Acupuncture Research
    • /
    • v.19 no.5
    • /
    • pp.92-111
    • /
    • 2002
  • Objective : Carthami Flos has been used as a herb to promote blood circulation to remove blood stasis in oriental medicine for many centuries, and Amun(GV15) has been used as a meridian point to treat apoplexy etc. To investigate treatment of cerevral vascular disease(CVA) by promoting blood circulation and removing blood stasis(活血化瘀法), we observed the experimental effects and mechanism of auqa-acupunture of Carthami Flos(ACF) injected into GV15 on cerevral hemodynamics and cardiovascular system of rats. Method : Aqua-acupuncture of Carthami Flos(ACF) was injected into GV15, and then we investigated experimental effects and mechanism of ACF on the cerebral hemodynamics[regional cerebral blood flow(rCBF), pial arterial diameter(PAD), meal arterial blood pressure(MABP)] and cardiovascular system[cardiac muscle contractile force(CMF), heart rate(HR)I by pretreatment with methylene blue(MTB) and indomethacin(IDN). The changes in rCBF, MABP, CMF and HR were tested by Laser Doppler Flowmetry(LDF), and the changes in PAD was determinated by video microscopy methods and video analyzer. Results :The results were as follows in normal rats ; The changes of rCBF and PAD were significantly increased by ACF($120{\mu}{\ell}/kg$) in a injected time-dependent manner, but MABP was not changed by ACF. The changes of cardiovascular system were increased by ACF in a injected time-dependent manner. And pretreatment with MTB was significantly inhibited ACE induced increase of rCBF and PAD, and was decreased ACF induced increase of HR. And pretreatment with IDN was increased ACF induced MABP and CMF. And the results were as follows in cerebral ischemic rats ; The changes of rCBF was increased stabilizly by treatment with ACF($120{\mu}{\ell}/kg$) in during the period of cerebral reperfusion, but pretreatment with MTB was increased ACF induced increase of rCBF during the period of cerebral reperfusion. The results were as follows in normal rats ; The changes of rCBF and PAD were significantly increased by ACF($120{\mu}{\ell}/kg$) in a injected time-dependent manner, but MABP was not changed by ACF. The changes of cardiovascular system were increased by ACF in a injected time-dependent manner. And pretreatment with MTB was significantly inhibited ACF induced increase of rCBF and PAD, and was decreased ACF induced increase of HR. And pretreatment with IDN was increased ACF induced MABP and CMF. And the results were as follows in cerebral ischemic rats ; The changes of rCBF was increased stabilizly by treatment with ACF($120{\mu}{\ell}/kg$) in during the period of cerebral reperfusion, but pretreatment with MTB was increased ACF induced increase of rCBF during the period of cerebral reperfusion Conclusions : In conclusion, ACF causes a diverse response of rCBF, PAD an HR, and action of ACF is mediated by cyclic GMP. I suggested that ACF has an anti-ischemic effect through the improvement of crebral hemodynamics in a transient cerebral ischemia.

  • PDF

Risk Factors Analysis and Results of the Arterial Switch Operation for Transposition of the Great Arteries with Intact Ventricular Septum (심실중격결손을 동반하지 않은 대혈관전위증 환자에서 동맥 전환술의 결과 및 위험인자 분석에 관한 연구)

  • 김용진;오삼세;이정렬;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.108-118
    • /
    • 1999
  • Background: To evaluate the risk factor and long-term result of arterial switch operation , a retrospective study was done. Material and Method: A retrospective analysis was done to evaluate the early and long-term results on 58 patients who underwent an arterial switch operation(ASO) for transposition of the great arteries(TGA) with intact ventricular septum, between January 1988 and December 1996. Beforesurgery, 36 patients(62.1%) underwent balloon atrial septostomy, 32 patients(51.7%) received PGE1 infusion, and preparatory banding of pulmonary artery was performed on 6 patients(mean LV/RV pressure ratio 0.53$\pm$0.11). Result: The age at operation ranged from 1 to 137 days(mean 24$\pm$26 days) and the weights ranged from 1.8 to 6.8 kg (mean 3.5$\pm$0.8 kg). There were 14 early deaths(24.1%), but of the last 24 patients operated on since 1994, there were only 2 early deaths(8.3%). In the risk factor analysis, the date of operation was the only risk factor for early death(p-value < 0.01). Eight of the 14 early deaths were due to acute myocardial failure(mainly inadequate coronary blood flow). The length of follow-up ranged from 2 months to 8 years, average of 36$\pm$27 months. The follow-up included sequential noninvasive evaluations and 21 catheterizations and angiographic studies performed 5 to 32 months postoperatively with particular attention to the great vessel and coronary anastomosis, ventricular function, valvular competence, and cardiac rhythm. There were 5 late deaths(11.4%), one of thesedeaths was related to the late coronary problems, two to aspiration, one to uncontrolled chronic mediastinitis, and one to progressive aortic insufficiency and heart failure. The most frequent postoperative hemodynamic abnormality was supravalvular stenosis and the degree of pulmonary or aortic obstruction had slowly progressed in some cases, however there were no children who had to undergo a reoperation for supravalvular pulmonary or aortic stenosis. Aortic regurgitation was identified in 9 patients, which was mild in 7 and moderate in 2 and had progressed in some cases. Two patients who had an unremarkable perioperative course were identified as having coronary artery obstructions. The other late survivors were in good condition, were in sinus rhythm, and had normal LV functions. Actuarial survival rate at 8 years was 68.8%. Conclusion: We concluded that anatomic correction will be established as the optimal approach to the TGA with intact ventricular septum, though further long-term evaluations are needed.

  • PDF

Cardiovascular and Perceived Exertion Response to Treadmill Running and Cycle Ergometer Exercise in Responder and Nonresponder Acute Coronary Syndrome Patients (심장재활에 참여한 급성 관상동맥증후군 환자에서 약물 반응과 운동 형태의 변화에 따른 심혈관과 운동자각도의 반응)

  • Kim, Young-Joo;Kim, Chul-Hyun
    • Journal of Life Science
    • /
    • v.18 no.9
    • /
    • pp.1263-1270
    • /
    • 2008
  • The purpose of this study is to investigate the effect of exercise mode and anti-hypertensive drug responding status on the cardiovascular response and perceived exertion in acute coronary syndrome (ACS) patients. Seventy-five patients who participated in six-week exercise rehabilitation therapy performed a treadmill running and a cycle ergometer exercise at intensities of 60%HRR and 85%HRR respectively. Systolic and diastolic blood pressure, mean arterial blood pressure (MAP), rate pressure production (RPP), and ratings of perceived exertion (RPE) were measured. The results of cardiovascular response by the different exercise modes with moderate and intensive intensity of anti-hypertensive drug responder and nonresponder ACS patients were following: First cycle ergometer exercise induced significantly higher SBP, DBP, MAP, RPP and MAP than treadmill running exercise at the intensities of 60%HRR and 85%HRR in both anti-hypertensive responder and nonresponder ACS patients (p<0.05). Secondly anti-hypertensive nonresponder ACS patients had significantly higher DBP and MAP that anti-hypertensive responder ACS patients at all the exercise modes (p<0.05). Finally there was no difference of RPP between anti-hypertensive responder and nomresponder ACS patients, although anti-hypertensive nonresponder ACS patients showed higher blood pressure and RPP than anti-hypertensive responder ACS patients. In conclusion, cycle ergometer induced increased cardiovascular response at same intensities of treadmill running exercise and anti-hypertensive nonresponder ACS patients had even more increased cardiovascular response than anti-hypertensive responder ACS patients with no difference in perceived exertion during exercise. These results suggested that cycle ergometer exercise should be greatly careful with the risk of higher blood pressure, especially for those who are patients with hypertensive blood pressure.

Prenatally Diagnosed Uncommon Mosaic Autosomal Trisomy

  • Lee, Bom-Yi;Park, So-Yeon;Lee, Moon-Hee;Kim, Jin-Woo;Park, Ju-Yeon;Choi, Eun-Young;Lee, Yeon-Woo;Oh, Ah-Rum;Lee, Shin-Young;Kim, Min-Hyung;Ryu, Hyun-Mee
    • Journal of Genetic Medicine
    • /
    • v.6 no.1
    • /
    • pp.95-99
    • /
    • 2009
  • Prenatal diagnosis of rare autosome mosaicism involvingchromosomes other than chromosome 13, 18, 21 or the sex chromosome is encountered prognostic dilemma during genetic counseling. We report four cases of level III uncommon mosaicism of trisomy 5, 16 and 20,diagnosed prenatally. In case 1 with mosaic trisomy 20, there was a higher mosaic ratio of trisomy 20 in the repeat amniocentesis (62.1%) than in the first (36.6%) with normal fetal ultrasound finding except for a relatively small aorta on a 3-vessel view of the fetal heart. Case 2 showed a low rate of mosaic trisomy 20 (5.25%) in cultured amniocytes but normal karyotype in the repeat amniocentesis, who delivered a normal healthy baby. Case 3 showed a 13.6% of trisomy 16 mosaicism in the 30 cells of cultured amniocytes. Sixty cells from a fetal blood sample at termination showed non-mosaic 46,XX normal karyotype, while skin fibroblasts had 22.5% trisomy 16 in 40 metaphases. The autopsy showed ventricular septal defect (VSD). Case 4 with low grade mosaicism (10.5%) of trisomy 5 resulted in elective termination, though the ultrasoumd showed growsly normal fetus. Although level III mosaicism is regarded as true mosaicism, it is difficult to predict the outcome of the fetus with rare mosaic autosome trisomy. Therefore mosaic autosome trisomy of fetus should be carefully interpreted with more various approaches including repeat sampling and targeted fetal ultrasound.

  • PDF

Immunogenicity, Reactogenicity and Safety of a Combined DTPa-IPV Vaccine Compared with Separate DTPa and IPV Vaccines in Healthy Korean Infants (한국의 건강한 영아를 대상으로 DTPa-IPV 혼합백신을 접종한 경우와 DTPa 백신과 IPV 백신을 각각 투여하였을 경우의 면역원성, 반응원성 및 안전성)

  • Kim, Chang Hwi;Cha, Sung Ho;Shin, Son Moon;Kim, Chun Soo;Choi, Young Youn;Hong, Young Jin;Chey, Myoung Jae;Kim, Kwang Nam;Hur, Jae Kyun;Jo, Dae Sun;Kim, Sung Shin;Lee, Sang Lak;Song, Eun Song;Ramakrishnan, Gunasekaran;Ok, Jin Ju;Van Der Meeren, Olivier;Bock, Hans L.;Kim, Jung Soo
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.156-168
    • /
    • 2010
  • Purpose : To compare immunogenicity and reactogenicity of a combined diphtheria-tetanus-acellular pertussis-inactivated poliovirus vaccine (DTPa-IPV, $Infanrix^{TM}$ IPV, GlaxoSmithKline Biologicals) with co-administration of commercially available DTPa and IPV vaccines at separate injection sites (DTPa+IPV). Methods : A total of 458 infants aged 8-12 weeks were randomized to receive three-ose primary vaccination at 2, 4 and 6 months with DTPa-IPV or DTPa+IPV. Blood samples were collected pre and post vaccination for measurement of immune responses. Reactogenicity was assessed following each dose using diary cards. Results : One month post-dose 3, seroprotection rates for anti-diphtheria, anti-tetanus and anti-poliovirus types 1, 2 and 3 were ${\geq}99.5%$ and vaccine response rates to pertussis antigens were at least 98.6% in both DTPa-IPV and DTPa + IPV groups. Non-inferiority between the groups was demonstrated based on pre-defined statistical criteria. Incidences of both local and systemic symptoms were within the same range across both groups with grade 3 symptoms reported following no more than 4.3% of DTPa-IPV doses and 4.5% of DTPa + IPV doses. Two serious adverse events (both pyrexia) after DTPa-IPV administration were considered vaccine-related. Both infants recovered fully. Conclusion : Combined DTPa-IPV vaccine was immunogenic and well tolerated when used as a three-dose primary vaccination course in Korean infants. DTPa-IPV could be incorporated into the Korean vaccination schedule, reducing the number of injections required to complete primary immunization.

Comparison of the Clinical Performance between Two Pulse Oximeters in NICU: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$ (신생아 중환자실에서 맥박산소측정기의 감지도 비교: Nellcor $N-595^{(R)}$ versus Masimo $SET^{(R)}$)

  • Lee, Heun-Ji;Choi, Jang-Hwan;Min, Sung-Ju;Kim, Do-Hyun;Kim, Hee-Sup
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.245-249
    • /
    • 2010
  • Purpose: Numerous false alarms by pulse oximetry, which is widely used in neonatal intensive care unit, can delay response to true alarms. Masimo $SET^{(R)}$ was introduced lately, to overcome false alarms by motion. We compared the clinical performance of two devices (Nellcor $N-595^{(R)}$ and Masimo $SET^{(R)}$) for the evaluation of the false alarm frequency during usual motion artifacts and stable state. Methods: A total of 20 preterm infants weighing 1,000-2,500 g were enrolled in the study. The sensors of two devices were placed on the different feet on the same infants, and both devices were programmed to emit an alarm for episode of hypoxemia (SpO2$\leq$85%). The false alarms were defined as episodes of poor correlation with ECG heart rate, poor waveforms, and the absence of obvious signs of hypoxia. We compared the frequency of false alarms between the two devices. Results: The mean chronological age was 20.8 days and the mean body weight was 1,668 g on the study day. The frequency of total false alarm was significantly fewer for Masimo $SET^{(R)}$ pulse oximetry (48 in Nellcor $N-595^{(R)}$, 27 in Masimo $SET^{(R)}$) although the false alarm during usual motion artifacts was not significantly between two devices (32 in Nellcor $N-595^{(R)}$, 19 in Masimo $SET^{(R)}$). Conclusion: The Masimo $SET^{(R)}$ pulse oximetry has fewer false alarm rates and identified more true hypoxic events than Nellcor $N-595^{(R)}$ pulse oximetry. Therefore, it is useful for adequate oxygen therapy and helps to decrease unnecessary handling by clinicians and nurses.