• Title/Summary/Keyword: HDR Imaging

Search Result 30, Processing Time 0.032 seconds

Logarithmic Tone Mapping for High Dynamic Range Imaging

  • Lee, Joo-Hyun;Jeon, Gwang-Gil;Jeong, Je-Chang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.154-157
    • /
    • 2009
  • High dynamic range image can describe the real world scenes that have a wide range of luminance intensity. To display high dynamic range (HDR) image into conventional displayable devices such as monitors and printers, we proposed the logarithmic based global mapping algorithm that consider the features of image using mapping parameters. Based on characteristics of image, we first modify input luminance values for reproducing perceptually tuned images and then displayable output values are obtained directly. The experimental results show that the proposed algorithm achieves good subjective results while preserving details of image, furthermore proposed algorithm has fast simple and practical structure for implementation.

  • PDF

Color Correction Method for High Dynamic Range Image Using Dynamic Cone Response Function (동적 원추 세포 응답을 이용한 높은 동적 폭을 갖는 영상 색상 보정 방법)

  • Choi, Ho-Hyoung;Yun, Byoung-Ju
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.104-112
    • /
    • 2012
  • Recently, the HDR imaging technique that mimics human eye is incorporated with LCD/LED display devices to deal with mismatch between the real world scene and the displayed image. However, HDR image has a veiling glare limit as well as a scale of the local contrast problem. In order to overcome these problems, several color correction methods, CSR(center/surround Retinex), MSR (Multi-Scale Retinex), tone-mapping method, iCAM06 and so on, are proposed. However, these methods have a dominated color throughout the entire resulting image after performing color correction. Accordingly, this paper presents a new color correction method using dynamic cone response function. The proposed color correction method consists of tone-mapping and dynamic cone response. The tone-mapping is obtained by using a linear interpolation between chromatic and achromatic. Thereafter, the resulting image is processed through the dynamic cone response function, which estimates the dynamic responses of human visual system as well as deals with mismatch between the real scene image and the rendered image. The experiment results show that the proposed method yields better performance of color correction over the conventional methods.

Evaluating Quadriceps Muscle Damage after Downhill Running of Different Intensities using Ultrasonography (내리막 달리기 후 국소 근손상의 영상학적 비교분석 : 운동 강도의 영향)

  • Sun, Min Ghyu;Kim, Choun Sub;Kim, Maeng Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.1028-1040
    • /
    • 2019
  • The current study was performed to investigate the magnitude of exercise-induced muscle damage (EIMD) after downhill running (DR) of different intensities and to examine the availability of muscle echo intensity as biomarkers to detect regional damage within quadriceps muscle group (QG) following DR. Healthy college-age men (n=11) were experienced twice DR sessions [$50%HR_{max}$ DR, LDR; $70%HR_{max}$ DR, HDR] separated by a 2-week wash-out period with the random order. After DR, severity of EIMD according to exercise intensity were determined by serum creatine kinase (CK) activity, muscle tenderness, and neuromuscular function indicators such as a maximal voluntary isometric contraction (MVIC) and range of motion (ROM). Transvaginal B-mode imaging had been employed to evaluate regional muscle echo intensity within QG [rectus femoris, RF; vastus lateralis, VL; vastus medialis, VM; vastus intermedius, VI]. After both DR sessions, changes in serum CK activity and muscle tenderness have tended to more increase in HDR compared to those of LDR. There was a significant interaction effect between exercise intensity during DR and the time course of serum CK activity(p<.05). However, there were no statistical differences between sessions in muscle tenderness. The time course of changes in the neuromuscular functions after DR were similar to those of regional muscle echo intensity regardless exercise intensity. Although neuromuscular function showed to decline in HDR more than those of LDR after DR, no statistical differences between sessions. In contrast, there were significant interaction effects between sessions and time course of changes in RF and VL muscle echo intensity(p<.01), but not shown in those of VI and VM. These results indicated that each muscles within the QG show different response profiles for EIMD during DR, exercise intensity influences on these responses as well. In particular, current findings suggested that muscle echo intensity derived from ultrasound imaging is capable of detecting regional muscle damage in QG following DR.

HDR image display combines weighted least square filtering with color appearance model

  • Piao, Meixian;Lee, Kyungjun;Jeong, Jechang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2016.06a
    • /
    • pp.260-263
    • /
    • 2016
  • Recently high dynamic range imaging technique is hot issue in computer graphic area. We present a progressive tone mapping algorithm, which is based on weighted least squares optimization framework. Our approach combines weighted leastsquaresfiltering with iCAM06, for showing more perceptual high dynamic range images in conventional display, while avoiding visual halo artifacts. We decompose high dynamic range image into base layer and detail layer. The base layer has large scale variation, it is obtained by using weighted least squares filtering, and then the base layer incorporates iCAM06 model. Then, adaptive compression on the base layer according to human visual system. Only the base layer reduces contrast, and preserving detail. The resultshows more perceptual color appearance and preserve fine detail, while avoiding common artifacts.

  • PDF

3D Shape Acquisition Using HDRI and Structured Lighting (HDR 영상과 구조적 조명을 이용한 3차원 형상 취득 기법)

  • Park, Tae-Jang;Won, Jae-Hyun;Lee, Man-Hee;Park, In-Kyu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.198-200
    • /
    • 2010
  • 구조적 조명 기법은 그레이코드 패턴광을 물체에 투영시켜 정확하게 3차원 형상 정보를 복원 할 수 있는 방법이다. 그러나 물체에 투영되는 그레이코드 패턴광이 카메라에 정확하게 인식 되어야 보다 정밀하게 3차원 좌표를 추정할 수 있다. 즉, 주변광의 밝기가 패턴광의 밝기에 비해 무시할 수 없을 정도로 밝은 경우 카메라가 물체와 투영된 패턴을 정확히 인식하기 어렵다. 본 논문에서는 구조적 조명 기법이 주변의 밝기에 따라 제한적인 문제점을 해결하기 위해 High Dynamic Range Imaging (HDRI) 알고리즘을 적용시켜 보다 넓은 동적 범위의 밝기 영역에서 3차원 형상을 정확하게 복원하는 방법을 제안한다. 실험결과 HDRI를 이용하여 복원하였을 경우 그렇지 않은 경우에 비해 복원 정밀도가 크게 개선되는 것을 확인할 수 있다.

  • PDF

Super Resolution Reconstruction from Multiple Exposure Images (노출이 다른 다수의 입력 영상을 사용한 초해상도 영상 복원)

  • Lee, Tae-Hyoung;Ha, Ho-Gun;Lee, Cheol-Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.1
    • /
    • pp.73-80
    • /
    • 2012
  • Recent research efforts have focused on combining high dynamic range imaging with super-resolution reconstruction to enhance both the intensity range and resolution of images. The processes developed to date start with a set of multiple-exposure input images with low dynamic range (LDR) and low resolution (LR), and require several procedural steps: conversion from LDR to HDR, SR reconstruction, and tone mapping. Input images captured with irregular exposure steps have an impact on the quality of the output images from this process. In this paper, we present a simplified framework to replace the separate procedures of previous methods that is also robust to different sets of input images. The proposed method first calculates weight maps to determine the best visible parts of the input images. The weight maps are then applied directly to SR reconstruction, and the best visible parts for the dark and highlighted areas of each input image are preserved without LDR-to-HDR conversion, resulting in high dynamic range. A new luminance control factor (LCF) is used during SR reconstruction to adjust the luminance of input images captured during irregular exposure steps and ensure acceptable luminance of the resulting output images. Experimental results show that the proposed method produces SR images of HDR quality with luminance compensation.

Quality Assurance of Air Kerma Strength for Ir-192 High Dose Rate Source (Ir-192 고선량률 선원에 대한 공기커마강도의 품질보증)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.147-151
    • /
    • 2007
  • AAPM TG43 report has recommended to measure air kerma strength with the strength of source. Main purpose of this study is to verify the accuracy of air kerma strength provided by manufacturer. Materials for this study were MAX-4001 Electrometer, HDR 1000 Plus of the corporation of standard imaging, and 6 french bronchial Applicator with 1000 mm. we measured ionization current in 10-90 mm range from the bottom of the central axis of chamber. The reference point of calibration displayed by the maximum ionization current in the ionization current curve was measured, and air kerma strength was computed from the maximum ionization current. we acquired 50 mm distance to correspond with the maximum ionization current in the ionization current curve. Its distance has perfectly fitted to the source reference point of calibration certificate of UW-ADCL. Air kerma strength computed value has measured about 0.5% more than calibration value provided by manufacturer. Air kerma strength of calibration certificate provided by manufacturer has acquired reliable results. This study shows that considering the move error of dwell position of source and the dead space length in well-type chamber is a good way to get an accurate result.

  • PDF

The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging (방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.207-215
    • /
    • 1998
  • There have been many radiation measurement methods so far among which film dosimetry, TLD, and ion chamber are the most frequently used methods. But this study describes a new radiation measurement method which uses polymer gel and magnetic resonance imaging(MRI). The objective of this study is to fabricate a polymer gel sensitive to radiation and to generate a dose to MRI contrast relationship, and to apply this results to the radiation measurement for the brachytherapy. To do this, 12 cm diameter cylindrical gel phantom was made, and the phantom was irradiated using the 30 mm diameter circular collimator which was used for radiosurgery. And this irradiated phantom was scanned with MRI. To find out the relationship between the radiation dose and the transversal relaxation time, an image processing software(IDL) was used. From this study it is found out that the radiation dose showed linear relationship to the transversal relaxation time of the gel up to 17 Gy($R^2$=0.993) and they had a different relationship above 17 Gy. The dose distributions were calculated using these results for the Ir-192 sources, one for the HDR afterloading system and the other for a 2 mCi seed source. And these calculated dose distributions were compared to the ones from the treatment planning computers. From this study the dose to the irradiated gel's transversal relaxation time relationship was examined, and this result was tried for the measurement of the brachytherapy.

  • PDF

Estimation of Differently Exposed Low Dynamic Range Images from a Single Bayer Image (단일 Bayer 영상으로 부터 다양한 노출을 가지는 Low Dynamic Range 영상들의 추정)

  • Lee, Tae-Hyoung;Ha, Ho-Gun;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.2
    • /
    • pp.74-79
    • /
    • 2011
  • HDR(high dynamic range) imaging techniques supports wider dynamic range than normal images captured from general still camera. These usually need several shots to obtain LDR(low dynamic range) images, causing ghosting artifacts. Accordingly, this paper suggests a method to generate new LDR images from a single Bayer image using Exposure LUT(look-up table) by considering channel dependency. We prior construct exposure LUT for each RGB channel, showing the relationship between input and average output luminance values. In the process, by applying the average luminance of input image and current exposure to LUT, new exposures which are determined by user choice are first estimated. Next, LDR images which are corresponded to new exposures are generated based on each LUT. Saturated areas are improved by considering channel dependency in the last procedure. In the experimental comparison, high PSNR values are obtained between estimated and captured images. Also, we have similar appearance on displayed images.

Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교)

  • Cho, Jung-Ken;Han, Tae-Jong
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose : In spite of recent remarkable improvement of diagnostic imaging modalities such as CT, MRI, and PET and radiation therapy planing systems, ICR plan of uterine cervix cancer, based on recommendation of ICRU38(2D film-based) such as Point A, is still used widely. A 3-dimensional ICR plan based on CT image provides dose-volume histogram(DVH) information of the tumor and normal tissue. In this study, we compared tumor-dose, rectal-dose and bladder-dose through an analysis of DVH between CTV plan and ICRU38 plan based on CT image. Method and Material : We analyzed 11 patients with a cervix cancer who received the ICR of Ir-192 HDR. After 40Gy of external beam radiation therapy, ICR plan was established using PLATO(Nucletron) v.14.2 planing system. CT scan was done to all the patients using CT-simulator(Ultra Z, Philips). We contoured CTV, rectum and bladder on the CT image and established CTV plan which delivers the 100% dose to CTV and ICRU plan which delivers the 100% dose to the point A. Result : The volume$(average{\pm}SD)$ of CTV, rectum and bladder in all of 11 patients is $21.8{\pm}6.6cm^3,\;60.9{\pm}25.0cm^3,\;111.6{\pm}40.1cm^3$ respectively. The volume covered by 100% isodose curve is $126.7{\pm}18.9cm^3$ in ICRU plan and $98.2{\pm}74.5cm^3$ in CTV plan(p=0.0001), respectively. In (On) ICRU planning, $22.0cm^3$ of CTV volume was not covered by 100% isodose curve in one patient whose residual tumor size is greater than 4cm, while more than 100% dose was irradiated unnecessarily to the normal organ of $62.2{\pm}4.8cm^3$ other than the tumor in the remaining 10 patients with a residual tumor less than 4cm in size. Bladder dose recommended by ICRU 38 was $90.1{\pm}21.3%$ and $68.7{\pm}26.6%$ in ICRU plan and in CTV plan respectively(p=0.001) while rectal dose recommended by ICRU 38 was $86.4{\pm}18.3%$ and $76.9{\pm}15.6%$ in ICRU plan and in CTV plan, respectively(p=0.08). Bladder and rectum maximum dose was $137.2{\pm}50.1%,\;101.1{\pm}41.8%$ in ICRU plan and $107.6{\pm}47.9%,\;86.9{\pm}30.8%$ in CTV plan, respectively. Therefore, the radiation dose to normal organ was lower in CTV plan than in ICRU plan. But the normal tissue dose was remarkably higher than a recommended dose in CTV plan in one patient whose residual tumor size was greater than 4cm. The volume of rectum receiving more than 80% isodose (V80rec) was $1.8{\pm}2.4cm^3$ in ICRU plan and $0.7{\pm}1.0cm^3$ in CTV plan(p=0.02). The volume of bladder receiving more than 80% isodose(V80bla) was $12.2{\pm}8.9cm^3$ in ICRU plan and $3.5{\pm}4.1cm^3$ in CTV plan(p=0.005). According to these parameters, CTV plan could also save more normal tissue compared to ICRU38 plan. Conclusion : An unnecessary excessive radiation dose is irradiated to normal tissues within 100% isodose area in the traditional ICRU plan in case of a small size of cervix cancer, but if we use CTV plan based on CT image, the normal tissue dose could be reduced remarkably without a compromise of tumor dose. However, in a large tumor case, we need more research on an effective 3D-planing to reduce the normal tissue dose.