• 제목/요약/키워드: HCFC

검색결과 124건 처리시간 0.025초

The Study on the Performance Characteristics of $NH_3$ Refrigeration System using a Shell and Tube Type Heat Exchanger

  • Hong Suck-Ju;Ha Ok-Nam;Kim Jae-Youl;Kwon Il-Wook;Lee Seung-Jae;Jeon Sang-Sin;Jeong Song-Tae;Ha Kyoung-Soo
    • 한국공작기계학회논문집
    • /
    • 제14권4호
    • /
    • pp.69-74
    • /
    • 2005
  • Nowadays CFC and HCFC refrigerants are restricted because they causes to depletion of ozone layer. Accordingly, an experiment is apply to the $NH_3$ gas for refrigerant to study the performance characteristic and to improve the energy efficiency. An experiment are carried out for the condensed pressure in a range from 14.5bar to 16bar and for degree of superheat in a range from 0 to $10^{\circ}C$ at each condensed pressure. As the result of experiment, when degree of superheat is $1^{\circ}C$ and condensed pressure is 14.5bar, the refrigeration system showed the high performance.

일본의 $CO_2$ 냉매를 이용한 열펌프급탕기 개발 동향

  • 김만회
    • 대한설비공학회지:설비저널
    • /
    • 제31권7호
    • /
    • pp.65-70
    • /
    • 2002
  • 지구의 오존층을 보호하기 위한 몬트리올 의정서가 1987년 채택된 이후 오존층 파괴물질의 사용이 점차 감소되고 있다. 선진국의 경우 1995년 말부터 CFC냉매의 생산을 전폐하였고, HCFC냉매의 경우는 2020년 전폐를 목표로 대체냉매를 이용한 응용 기술개발 및 제품 생산이 진행되고 있다. 가정용 냉장고 및 차량용 에어컨에는 R-12의 대체냉매로 R-134a가 도입되었으며, 유럽을 중심으로 냉장고에는 HC계 냉매인 R-600a도 대체냉매로 사용되고 있다. 가정용 에어컨에는 혼합냉매인 R-407c 와 R-410a가 R-22 냉매를 대체하여 적용되고 있다. 그러나 현재, CFC및 HCFC 대체 냉매로 많이 사용되고 있는 HFC계 냉매도 지구 온난화 지수가 대단히 큰 문제를 가지고 있다. 1997년 채택된 교토의 정서에는 HFC계 냉매가 온실효과가 가스 배출규제물질에 포함되어 있다. 이에 따라서 오존층의 파괴지수가 영이고 지구온난화지수도 거의 없는 자연냉매가 주목을 받게 되었으며, 자연 냉매의 하나인 이산화탄소 ($CO_2$R744) 냉매의 응용기술 및 제품개발 연구가 선진국을 중심으로 폭넓게 진행되고 잇다. 본고에서는 $CO_2$냉매의 일반적인 특성을 간단히 소개하고 일본에서 진행되고 있는 $CO_2$냉매를 적용한 급탕시스템의 제품개발 및 시장현황에 대해서 기술하기로 한다.

  • PDF

CHARM을 통한 소화약제 위험성 평가에 관한 연구 (Risk Assessment of exposure to the extinguishing agents using CHARM)

  • 조중래;정태환
    • 한국방재안전학회논문집
    • /
    • 제10권2호
    • /
    • pp.35-41
    • /
    • 2017
  • 최근 소화약제 취급 관련 중독사고가 다발하고 있다. 산업이 발전하고 건물이 고층화됨에 따라 다양한 소화약제가 개발되고 있으며, 이에 따라 소화약제의 안전한 사용의 문제가 중요하게 대두되고 있다. 본 연구에서는 소화약제(HCFC-123, HFC-125)에 대한 화학물질 위험성평가를 안전보건공단에서 개발한 CHARM기법을 통해 실시해보았고, 의미 있는 결과를 얻을 수 있었다. 동 연구 자료가 향후 화학물질 안전관리 체계수립에 도움이 될 수 있기를 바란다.

대체냉매를 사용한 로타리 압축기의 마모시험 (Wear Test for Rotary Compressor using Alternative Refrigerants)

  • 좌성훈;백충국;장선태;오상경
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1995년도 제22회 학술대회
    • /
    • pp.28-37
    • /
    • 1995
  • To protect the ozone layer depeletion the CFC (chlorofluorocarbon). HCFC(hydrochlorofluorocarbon) refrigerants will be replaced with HFCs (hydro-fluorocarbon) as an alternative refrigerant. In recent years a good deal of effort has been made to develop new compressors which are compatible to the new referigent. This paper focused on developing accelerated screening test for predicting tribological characteristics of the rotary compressor in atmosphere of R407C as an alternative refrigerant with polyolester lubricant. Falex wear test machine with high pressure chamber has been used to simulate friction and wear behavior of the common contact geometries found in rotary compressors.

  • PDF

GC/FID를 이용한 Trifluoroacetic acid의 분석 (Analysis of Trifluoroacetic acid by GC/FID)

  • 노경록;홍영민;김만구
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.331-332
    • /
    • 2001
  • CFCs는 가정 제품과 공업적 과정에서 발포제와 냉매제로 오랜 기간 사용되었다. 1974년, CFCs는 Molina와 Rowland에 의해 성층권 오존의 고갈 요인으로 인식되었고, 최근에는 지구 온난화의 기여물질로써 관련되어 지고 있다. CFCs의 세계적인 생산은 Montreal 의정서와 그 개정안에 의해 점차 폐지되었고, 대체 물질로 HCFCs와 HFCs가 과도하게 사용되고 있다. 수소의 존재는 대체 물질의 대류권 산화를 가능하게 했고, 대체로 성층권에 영향을 미치지 않는다. (중략)

  • PDF

Rl23, R134a냉매 특성에 따른 증발기 설계 (Design of an evaporator heat exchanger for R123 and R134a refrigerants)

  • 김익생
    • 대한설비공학회지:설비저널
    • /
    • 제28권5호
    • /
    • pp.368-374
    • /
    • 1999
  • 최근 세계적으로 환경보호에 대한 관심이 고조됨에 따라 기술개발 방향이 환경을 고려한 규정 및 장치에 제한을 받고 있다. 따라서 냉동 공조 기기에 사용되는 기존의 CFC계열 냉매가 오존층 파괴의 주 원임이 판명됨에 따라 환경 문제가 없는 HCFC계열인 R123와 HFC R134a로의 대체가 불가피하게 되었다.

  • PDF

The Study on the Performance Characteristics due to the Degree of Superheat in $NH_3$ Refrigeration System III - The Comparison of Heat Exchanger Types -

  • Hong Suck-Ju;Ha Ok-Nam;Lee Kyu-Tae;Ha Kyung-Soo;Jeong Song-Tae;Hong Seong-In;Yun Kab-Sig;Kim Yang-Hyun;Kwon Il-Wook;Lee Jong-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권1호
    • /
    • pp.7-13
    • /
    • 2006
  • Because the usage of CFC and HCFC based refrigerants are restricted due to the depletion of ozone layer, the $NH_3$ gas, in the experiment is evaluated to the performance characteristics for the superheat control to improve the energy efficiency. The experiment is carried out about the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa through the degree of superheat from 0 to $10^{\circ}C$ at each condensing pressure. As a result, in the case of shell and tube type of heat exchanger, the COP is more efficient than other cases at the degree of superheat $1^{\circ}C$ at each condensing pressure. In the case of shell and disk type of heat exchanger, the COP is the most efficient at the degree of superheat 0.

연질 폴리우레탄 발포체 제조에서 발포제와 내부 온도와의 관계 (The Relationship between Blowing Agents and Inner Temperature at the Preparation of Flexible Polyurethane Forams)

  • 이석우;김진흥;김강호;양유경;안종일;명영찬
    • 한국응용과학기술학회지
    • /
    • 제16권2호
    • /
    • pp.179-185
    • /
    • 1999
  • 본 연구에서는 연질 폴리우레탄 발포제 제조에서 여러 발포제와 내부온도, 기계적 물성과의 관계에 대해서 연구, 조사하였다. 발포제로는 물을 주발포제로 하여 보조발포제는 CFC-11(trichlorofluoromethane), HCFC-114b(dichlorofluoroethane), dichloromethane, n-pentane, iso-pentane, cyclopentane을 사용하였다. 기계적 물성을 측정하기 위하여 연질 폴리우레탄 발포제의 밀도가 $0.015{\pm}0.002g/cm^3$$0.024{\pm}0.002g/cm^3$인 두 종류의 발포제를 제조하였다. 연질 폴리우레탄의 발포제의 제조시 발포제별로 내부온도를 측정하였으며, 48시간 경과 후 밀도, 인장강도, 신장율, 인열강도, 압축강도, 압축영구변형률을 측정하였다. 연구 결과 dichloromethane과 cyclopentane이 보조발포제로 가장 적합하였다.

Pentachloroethane의 불소화 반응에 관한 연구 (A Study on the Fluorination of Pentachloroethane)

  • 박건유;권영수;김훈식;이상득;이병권
    • 공업화학
    • /
    • 제4권2호
    • /
    • pp.318-323
    • /
    • 1993
  • CFC-11$(CFCl_3)$의 대체품인 HCFC-123$(CF_3CHCl_2)$의 합성을 위하여 Pentachloroethane($CHCl_2CCl_3$)을 제조하고, 이것을 antimony pentahalide 촉매의 존재하에서 불화수소와 반응시켰다. $CHCl_2CCl_3$의 불소화 반응은 촉매와 반응물간의 Cl-F교환 mechanism에 의해 진행되었으며 $CHCl_2CCl_3$의 불화도는 반응온도가 높을수록 증가하는 경향을 보여 주었다. 촉매농도 또한 생성물의 불화도에 영향을 미치나 반응온도에 비해 상대적으로 낮았다. $CCl_3CFCl_2$, $CFCl_2CFCl_2$, $CF_2ClCFCl_2$와 같은 부산물의 생성원인을 규명하기 위한 실험을 실시하여 부산물 생성 mechanism을 제안하였다.

  • PDF

$NH_3$ 냉동장치의 과열도 변화에 의한 성능 특성 연구 II -열교환기 타입 변경- (The Study on Performance Characteristics of $NH_3$ Refrigeration System for Various Degree of Superheat - Part II : The Change of Heat Exchanger Type -)

  • 하옥남;권일욱;전상신;이승재;정송태;하경수;윤갑식;이종인;홍경한
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.297-302
    • /
    • 2005
  • Since the use of CFC and HCFC refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the $NH_3$ gas to study the performance characteristics of $NH_3$ refrigeration system by the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa and for degree of superheat from $0^{\circ}C\;to\;10^{\circ}C$ at each condensing pressure. As a result of experiment, when the degree of superheat is $0^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.