• Title/Summary/Keyword: HC290

Search Result 16, Processing Time 0.017 seconds

Performance of HFC152a, HFC134a and HC290 Mixtures as Alternative Refrigerants for HFC134a (HFC152a, HFC134a, 프로판을 포함한 자동차용 대체/보충 냉매의 성능)

  • Kang, Nam-Koo;Bae, Guen-Hwan;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.383-391
    • /
    • 2010
  • In this study, HFC152a, HFC134a/HFC152a and HC290/HFC134a/HFC152a mixtures are studied for the supplementary and alternative refrigerants for HFC134a used in automobile air-conditioners. Due to the high global warming potential of HFC134a, it has to be phased out in the long run. Thermodynamic performance of these refrigerants are measured in a bench tester of 3.5 kW capacity with an open type compressor under both summer and winter conditions. Test results show that the coefficient of performance (COP) and capacity of pure HFC152a and HFC134a/HFC152a mixture are 9.1~12% and 7% higher than those of HFC134a. As for the HC290/HFC134a/HFC152a, the COP is up to 9.5% higher than that of HFC134a with 1~2% of HC290 while that is up to 6.1% lower than that of HFC134a with 5% HC290. The capacity of the ternary mixture, however, is 8.6% higher than that of HFC134a at all compositions tested. The compressor discharge temperatures of all refrigerants tested are $6{\sim}10^{\circ}C$ higher than that of HFC134a. For all refrigerants, the amount of charge is reduced up to 32% due to the decrease in liquid density. Overall, these refrigerants provide good performance with reasonable energy savings with less environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

The Effect of Biodiesel Blend Fuels As Reductants on NOx Conversion Efficiency of HC_SCR (환원제로서 바이오디젤 혼합연료가 HC-SCR의 NOx 변환효율에 미치는 영향 연구)

  • Song, Hoyoung;Lee, Minho;Kim, Kiho
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.140-145
    • /
    • 2015
  • This study was aimed at analyzing NOx conversion characteristics in the HC-SCR with biodiesel content changes of the secondary fuel injection (BD0, BD10, BD25). Test conditions for temperature were set to $290^{\circ}C$, $320^{\circ}C$ and $350^{\circ}C$ considering the upstream temperature of a HC-SCR, distillation of the secondary injected fuels and etc. The amount of fuel injection was adjusted with a fixed space velocity of 55,000(1/h). According to the test results of distillation, the T90 was the same level about $350^{\circ}C$ on all test fuels and the amount of evaporation was reduced at lower than $350^{\circ}C$ temperature condition with increasing biodiesel content. As biodiesel content which is mixed with the secondary injected fuel is increased, NOx reduction efficiency was determined to decrease. The difference of the Nox reduction ratio in a high temperature condition($320^{\circ}C$ and $350^{\circ}C$) than the low temperature($290^{\circ}C$) was more significant. These results are thought to be poor evaporation properties (distillation) and high molecular weight of the biodiesel.

Evaporation Heat Transfer Characteristics of Hydrocarbon Refrigerants R-290 and R-600a in the Horizontal Tubes

  • Roh, Geon-Sang;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.74-83
    • /
    • 2007
  • This paper presents the experimental results of evaporation heat transfer coefficients of HC refrigerants (e.g. R290 and R600a). R-22 as a HCFCs refrigerant and R-l34a as a HFCs refrigerant in horizontal double pipe heat exchangers, having four different inner diameters of 10.07, 7.73, 6.54 and 5.80 mm respectively. The experiments of the evaporation process were conducted at mass flux of $35.5{\sim}210.4 kg/m^2s$ and cooling capacity of $0.95{\sim}10.1 kW$. The main results were summarized as follows : The average evaporation heat transfer coefficient of hydrocarbon refrigerants(R-290 and R-600a) was higher than the refrigerants, R-22 and R-l34a. In comparison with R-22 the evaporation heat transfer coefficient of R-l34a is approximately $-11{\sim}8.1 %$ higher. R-290 is $56.7{\sim}70.1 %$ higher and R-600a is $46.9{\sim}59.7 %$ higher. respectively. In comparison with experimental data and some correlations, the evaporation heat transfer coefficients are well predicted with the Kandlikar's correlation regardless of a type of refrigerants and tube diameters.

Fomulation Study for GAP/ADN Propellant (GAP/ADN 추진제 조성 연구)

  • 유지창
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.25-25
    • /
    • 1998
  • 최근의 선진국의 전략미사일에 사용되는 추진제 개발 방향은 고에너지, 저민감, 무연 및 무공해 추진제를 목표로 하고 있다. 현재까지 가장 널리 사용되어온 AP는 성능이나 기계적 특성에서 우수한 산화제이나 로켓 모타 배출기체 중에 HC1을 생성함으로써 2차 연기를 생성하며, HC1 자체가 인체에 유해한 물질이라는 단점들을 가지고 있다. 또한 RDX나 HMX는 에너지가 높은 반면 쇽(shock)에 대해 매우 민감한 단점을 가지고 있다. AN은 이러한 HC1을 생성하는 AP의 단점과 쇽에 민감한 RDX와 HMX의 단점을 해결할 수 있는 대체 산화제로 사용할 수 있으나, 성능이 대외적으로 떨어지며 상변이와 흡습성이 높은 단점이 있다. ADN은 -100~+10$0^{\circ}C$범위에서 상 변이가 없고 밀도는 1.801g/㎤, Hf는 -290cal/g이다. ADN을 산화제로 사용하면 HTPB/AP 추진제와 동등하거나 그 이상의 성능을 갖는 추진제를 만들 수가 있으며, 유해 기체인 HC1을 배출하지 않음으로 인하여 2차 연기를 없애는 장점이 있다.

  • PDF

A Study of Hyperlipidemia in Koreans -II. Specially Related to Drinking Smoking Exercise and Environmental Characteristics and It's Risk Factors for Hypercholesterolemia- (한국인의 고지혈증에 관한 연구 -II. 고콜레스테롤혈증 소견자의 음주, 흡연, 운동 및 생활습관 특성과 그 위험인자를 중심으로-)

  • 허영란
    • The Korean Journal of Food And Nutrition
    • /
    • v.12 no.3
    • /
    • pp.290-299
    • /
    • 1999
  • This study was conducted to investigate drinking smoking exercise and environmental characteristics and it's risk factors for hypercholesterolemia (HC) in Korean. 344 adult men who took the annual health check-ups at D or J hospitals were participated in this corss-sectional study. The subjects were grouped by plasma total cholesterol level into three groups: normal cholesterolemic(n=139) borderline hyper-cholesterolemic (n=93) and hypercholesterolemic (n-112) groups. The data of plasma cholesterol level in the subjects were collected from medical records. Drinking smoking and exercise habits family and disease history personality type and stress level of subjects were investigated by using questionaries. The subjects with HC had longer drinking duration and drunk more frequently. The proportion of smok-er heavy smoker($\geq$2pack/day) and longer smoker ($\geq$30yrs) showed high in the HC but there were no significancy. The subjects with HC had preference for light exercise and exercised more frequently but there were no significant difference. The family history of cardiovascular diseases was higher in the were not different among the three groups. The relative risks on HC were 1.33 for family history, 1.22 for severe stress 1.06 for smoking and 1.04 for exercise.

  • PDF

An Experimental Study on Vapor-Liquid Equilibria of HFC and HC Refrigerant Mixtures (탄화수소 및 불화탄화수소 혼합냉매의 기상-액상 평형에 관한 실험적 연구)

  • 강병복;김민수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1031-1037
    • /
    • 2000
  • Isothermal vapor-liquid equilibrium(VLE) data have been obtained for the systems of propane(R290)+1,1,1,2-tetrafluoroethane(R134a) and 1,1,1,2-tetrafluoroethane(R134a)+isobutane(R60A) in the temperature range of 253.15 to 323.15K. Experiments were performed in a circulation type apparatus by injecting vapor through liquid pool using a magnetic pump. Both systems form azeotropes in the temperature range of this study. The experimental results were estimated with the Peng-Robinson equation of state. When the temperature-dependent binary interaction parameter was used in the Peng-Robinson equation of state, the absolute average deviation of the measured bubble point pressures from the values correlated by the Peng-Robinson equation was 0.65% and 0.78% for R290+R134a and R134a+600a, respectively. Azeotropic compositions for both systems were presented.

  • PDF

Evaporation kent transfer characteristics of R-290 and R-600a in the horizontal tubes (수평관내 R-290과 R-600a의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.264-269
    • /
    • 2008
  • This paper presents the experimental results of evaporation heat transfer coefficients of HC(e.g. R290 and R600a), R-22 as a HCFCs refrigerant in horizontal double pipe heat exchangers, having four different inner diameters of 10.07 mm and 6.54 mm respectively. The experiments of the evaporation process were conducted at mass flux of $35.5{\sim}210.4\;kg/m^2s$ and cooling capacity of $0.95{\sim}10.1\;kW$. The main results were summarized as follows : The average evaporation heat transfer coefficient of R-290 and R-600a was higher value than that of R-22. In comparison with R-22, the evaporation heat transfer coefficient of R-290 and 600a is approximately $56.7{\sim}70.1$ and $46.6{\sim}59.7%$ higher, respectively. In comparison with experimental data and some correlations, the evaporation heat transfer coefficients are well matched with the Kandlikar's correlation regardless of a type of refrigerants and tube diameters.

The application of hydrocarbon refrigerant mixtures in a hermetic reciprocating compressor for high back pressure conditions (고온용 밀폐형 왕복동 압축기에서 탄화수소계 혼합냉매 적용)

  • 김기문;박희용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.262-269
    • /
    • 1999
  • The application of hydrocarbon refrigerant mixtures in a hermetic reciprocating compressor for dehumidifier is investigated. The selected refrigerants are R12, R134a, HC-Blend (R290/R600a), CX(R152a/R600a) and OS-l2a. Both theoretical and experimental investigations have been performed for the selected refrigerants. The test results of hydrocarbon refrigerants have been compared to traditional refrigerant(R12) and R134a. The results show that hydrocarbon refrigerant mixtures(HC-Blend, CX and OS-l2a) are very good alternatives in the refrigeration system for R12 and R134a.

  • PDF

The application of hydrocarbon refrigerants in a hermetic reciprocating compressor for low back pressure conditions (저온용 밀폐형 왕복동 압축기에서 탄화수소계 냉매 적용)

  • 김기문;박희용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.683-694
    • /
    • 1998
  • The application of hydrocarbon refrigerants in a hermetic reciprocating compressor for refrigerator is investigated. The selected refrigerants are isobutane(R600a), propane(R290), R12, binary mixture of R600a/R290, and OS-21CII. Both theoretical and experimental investigations have been performed for the selected refrigerants. The test results of hydrocarbon refrigerants have been compared to the traditional refrigerant(R12). The results show that hydrocarbon refrigerants(HC-Blend, OS-21C II) are very good alternatives in the refrigeration system for R12.

  • PDF

Performance Characteristics of Air-Cooled Heat Pump System using Hydrocarbon Refrigerants According to Variation of Outdoor Temperature (실외 온도 변화에 따른 HC계 공랭식 히트펌프 시스템의 성능 특성)

  • Jun Chul-Ho;Lee Ho-Saeng;Kim Jae-Dol;Yoon Jung-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.218-224
    • /
    • 2006
  • The performance of an air to water vapor compression heat pump has been investigated experimentally. The main purpose of this study was to study the possibilities of using hydrocarbon refrigerants as a working fluid to replace R-22 for vapor compression heat pumps. Pure R-22 and R-290, R-600a, R-1270 were considered as working fluids. The performance of the system was characterized by compression shaft work, refrigeration capacity, pressure ratio, discharge temperature and COP. The experimental apparatus has basic parts of cycle that uses the air as a heat source. The experimental results show that refrigeration capacity of HC refrigerants is same or higher than that of R-22. On the other hand, compression shaft work of HC refrigerants is lower than that of R-22. Compression shaft work is lower than that of R-22. Come to the conclusion that, it is possible that hydrocarbon refrigerants could be drop-in alternatives for R-22.