• Title/Summary/Keyword: HACCP-based sanitation evaluation tool.

Search Result 2, Processing Time 0.017 seconds

Development of the Computer-Assisted HACCP System Program and Developing HACCP-Based Evaluation Tools of Sanitation for Institutional Foodservice Operations (단체급식의 HACCP 전산프로그램 및 위생관리 평가도구 개발)

  • 이정숙;홍희정;곽동경
    • Korean Journal of Community Nutrition
    • /
    • v.3 no.4
    • /
    • pp.655-667
    • /
    • 1998
  • The Computer-assisted Hazard Analysis and Critical Control Point(HACCP) program has been developed for a systematic implementation of HACCP principles in identifying, assessing and controlling hazards in institutional foodservics operations. The HACCP-based sanitation evaluation tool has been developed, based on the results of the computerized assisted HACCP program in 4 service sites of C contracted foodservice company, including 2 general hospitals with 650-beds, one office operation of 400 meals per day, and one factory foodservice of 1,000 meals per day. All database files and processing programs were created by using Unify Vision tool with Windows 95 of user environments. The results of this study can be summarized as follows : 1. This program consists of the pre-stage for HACCP study and the implementation stage of the HACCP system. 1) The pre-stage for HACCP study includes the selection of menu items, the development of the HACCP recipe, the construction of product flow diagrams, and printing the HACCP recipes and product flow diagrams. 2) The implementation of the HACCP system includes the identification of microbiological hazards, the determination of critical control points based on the decision tree base files. 3) The HACCP-based sanitation evaluation tool consisted of 3 dimensions of time-temperature relationship, personal hygiene, and equipment-facility sanitation. The Cronbach's alphas calculation indicated that the tool was reliable. The results showed that the focus groups rated the mean of importance in time-temperature relationship, personal hygiene, and equipment-facility sanitation as 4.57, 4.59 and 4.55 respectively. Based on the results, this HACCP-based sanitation evaluation tool was considered as an effective tool for assuring product quality. This program will assist foodservice managers to encourage a standardized approach in the HACCP study and to maintain a systematic approach for ensuring that the HACCP principles are applied correctly.

  • PDF

Development of the Hospital Foodservice Facility Evaluation tools based on the General HACCP-based Sanitation Standards and Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설ㆍ설비 위생관리 점검도구 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.3
    • /
    • pp.339-353
    • /
    • 2003
  • The rapid increase in food borne illness outbreaks in Korea has been one of the major threats to the Nation's Health. Foodservice establishments have been identified as the major place for these outbreaks, mainly due to the lack of sanitary management and sanitary facility management practices. The purposes of the study were to develop hospital foodservice facility evaluation tools, based on the general HACCP-based standards and guidelines, for hospital food service establishments, to ensure the safety of these foodservices and to reduce the risk of food home illness. The scope of this study included: 1) an assessment of the current foodservice sanitation practices and managements for 6 general hospitals, with more than 400 beds, and 3 general hospitals, with less than 400 beds; 2) the development of foodservice establishments sanitation evaluation tools and sanitation standards, based on the HACCP system. The survey data showed varied results between the hospitals surveyed. Most of the hospital foodservice operations had many problems with ventilation and the plumbing. The total dimensional mean scores for the hospitals with more than 400 beds and less than 400 beds were 31.5 and 27.0, respectively. The highest dimension scores were for the water supply facility and lighting, with the lowest for insect and rodent control and toxic materials management. The levels of the mean scores were very low, especially for the general hospitals with less than 400 beds. These low mean scores may have arisen from critical problems within the hospital foodservice operations. The most needed facility management items for improvement were: storage shelf should be spaced 6 inches from the floor and walls, the use of three compartment sinks, utility sinks and cleaning facilities, with a floor drain for cleaning mops or liquid wastes, a ventilation hood designed to prevent dripping onto food, cooking facilities should be disassembled for washing and sanitizing, a separated hand washing sink and a sanitized food board for each area should be provided, all toxic material must have warning labels attached, and be stored in an area away from food preparation under padlock. The evaluation tool consisted of 14 dimensions, with 65 check-off items. The results of this study will provide basic facilities' guidelines to regulators, or foodservice industry personnel, wishing to build, or expend, and establish an efficient flow of food. As a result, food borne illnesses will be effectively prevented, and the Nation's health will be promoted for the development of their own sanitation standards, with a checklist for the safe production of foods.