• 제목/요약/키워드: HA-coated surface

검색결과 192건 처리시간 0.041초

EFFECT OF MULTILAYER COATING ON THE CORROSION RESISTANCE OF SINTERED STAINLESS STEELS

  • Choe, Han-Cheol;Ko, Yeong-Mu
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2003년도 추계학술발표회초록집
    • /
    • pp.136-137
    • /
    • 2003
  • In this study, in order to fabricate sintered dental implant, the effects of HA, Ti and TiN on corrosion and biocompatibility, cell toxicity, osseointegration of electroless Cu-plated and sintered stainless steel implant were investigated using various characteristics. The effects of Ti/TiN/HA coating on the interface activation and surface characteristics of sintered stainless steels(SSS) by electron-beam physical vapor deposition(EB-PVD) method have been studied. Stainless steel compacts containing 2, 4, and 10 wt%Cu were prepared by electroless Cu-plating method which results in the increased homogenization in alloying powder. The specimens were coated with HA, Ti and TiN with few $\mu\textrm{m}$ thickness respectively by EB-PVD method. The microstructures and phase analysis were conducted by using SEM. Biocompatibility were investigated in experimental dog. The corrosion behaviors were investigated using potentiosat in 0.9% NaCl solution and corrosion surface was observed using SEM and XPS.

  • PDF

알루미늄 중력주조용 내구성 도형제의 도형조건에 따른 내마모 및 내열특성 연구 (A Study on the Wear and Heat Resistance Properties of Durable Moldwash Conditions for Al Gravity Die Casting According to Mold Washing Process Condition)

  • 김억수;남궁정;박진하;이광학
    • 한국주조공학회지
    • /
    • 제28권5호
    • /
    • pp.237-241
    • /
    • 2008
  • This study has been carried out to investigate the wear and heat resistant properties of durable moldwash agent for Al gravity casting according to mold washing process conditions. The wear properties of coated specimen were performed by sliding wear testing machine and heat resistance were evaluated by measuring the loss of coated moldwash agent during emerging of coated specimen in Al melts. During testing, experimental variables were mold surface temperature, moldwash agent/distilled wear, and additive concentrations. The lower additive concentration and mold temperature caused the smooth surface roughness of coated specimen, It was found that the specimen coated with moldwash/water ratio 1:3, additive concentration 9wt% and mold temperature higher than $200^{\circ}C$ showed superior wear and heat treatment. Also, these results were supported by fluidity test.

역삼투막 표면에 음이온 고분자 코팅을 통한 파울링 현상 감소연구 (Study on the Fouling Reduction of the RO Membrane by the Coating with an Anionic Polymer)

  • 조은혜;정성일;임지원
    • 멤브레인
    • /
    • 제22권6호
    • /
    • pp.481-488
    • /
    • 2012
  • 폴리아마이드 역삼투막 표면에 음이온 수용성 고분자인 poly(vinyl amine)(PVAm)을 코팅한 후 오염물질인 bovine serum albumin (BSA), humic acid (HA), sodium alginate (SA)에 대하여 파울링 개선효과가 있는지를 알아보고자 하였다. PVAm의 코팅과 파울링 여부는 scanning electron microscopy (SEM)을 통해 관찰하였다. BSA, HA, SA 100 ppm 공급원액을 이용하여 2, 4, 8 bar로 압력을 변화시켜 투과성능실험을 수행한 결과 PVAm으로 코팅되지 않은 막과 코팅된 막 모두 압력증가에 따라 파울링 현상이 심화되었으나 PVAm으로 코팅된 막이 BSA, HA, SA의 경우 모두에서 약 30%이상 투과도가 향상되어 파울링 개선효과가 나타나는 것을 확인할 수 있었다. HA > SA > BSA의 순으로 파울링 개선효과가 나타났으며 HA의 경우 가장 두드러지게 나타났다.

하이드록시아파타이트 코팅 리포솜의 초음파에 의한 약물방출 (Ultrasound-Triggered Drug Release of Hydroxyapatite Coated Liposomes)

  • 조성근;위태인;하정;조선행;한건;한희동;신병철
    • 대한화학회지
    • /
    • 제57권4호
    • /
    • pp.493-498
    • /
    • 2013
  • 리포솜은 표적 약물을 봉입하여 병소에 안전하게 전달할 수 있는 약물전달체로서 연구되고 있다. 그러나 일반적인 리포솜은 표적부위에서 약물방출이 제한적인 문제점이 있다. 따라서 본 연구에서는 리포솜의 안정성을 향상시키고 표적부위에서 외부 초음파로부터 약물의 방출을 극대화시키기 위하여 하이드록시아파타이트(hydroxyapatite, HA)가 코팅된 리포솜을 개발하였다. 대조군 리포솜은 인지질과 콜레스테롤을 이용하여 제조하였고, 대조군 리포솜의 표면에 칼슘 아세테이트, 포스포릭에시드, 그리고 25% 암모니아용액을 이용하여 HA를 코팅하였다. 모델 약물로는 독소루비신을 사용하였다. HA코팅 리포솜의 크기는 120 nm 이었고, 약물봉입효율은 95% 이상이었다. 30% 혈장용액 내에서 HA코팅 리포솜의 입자크기는 일정한 상태를 유지하였으며, 대조군 리포솜은 크기가 1.4배 증가하였다. 외부 초음파 자극에 의한 리포솜으로부터 약물 방출을 유도한 후, 방출된 약물의 세포 이입율은 HA 코팅된 리포솜이 3배 이상 대조군 리포솜에 비하여 증가하였다. 본 연구에서는 외부 초음파 자극에 의하여 리포솜으로부터 약물의 방출을 극대화시키기 위한 초음파 민감형 리포솜을 개발하였고, 본 제형은 표적부위에서 약물의 방출을 효과적으로 제어하기 위한 분야에 활용이 가능할 것이다.

침적법에 의한 수산화아파타이트 코팅 금속재의 기초적 연구 (Hydroxyapatite Coating on Ti Plate by a Dipping Method)

  • 이준희;김석영;김영곤;이인섭
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.217-222
    • /
    • 1997
  • Hydroxyapatite(HA)-coated metal composites were made by the dipping method. The specimen substrates were Ti plates with a thickness of 2 mm. The HA coating was carried out in HA-sol for 1 min by the dipping method. The concentration of HA-sol for the coating ranged from 3.28 to 9.99 wt%. Excellent coating was observed on Ti substrate dipped once in 9.99 wt% sol. Preparation of Ti plates by sandblasting provided the better environment for coating HA on Ti surface than non-treated surface. As the concentration of sol increased, the weight change and the coating thickness increased. Above 7 wt% sol, they increased sharply.

  • PDF

Histomorphometric Analysis of Two Types of Coated Implants : a Preliminary Study Using the Rabbit Tibia Model

  • Yeo, In-Sung;Lee, Hyo-Jung
    • Journal of Korean Dental Science
    • /
    • 제2권1호
    • /
    • pp.28-30
    • /
    • 2009
  • Purpose : The purpose of this pilot experiment was to evaluate early bone response in two types of coated implants using the rabbit tibia model. Materials and Methods : Screw type titanium implants manufactured with a calcium metaphosphate (CMP) coating and hydroxyapatite (HA) coating were placed in the tibiae of 3 New Zealand White rabbits. The bone responses at 2 weeks after insertion were evaluated and compared by histomorphometry. Results : There was no significant difference in bone-to-implant contact between the groups (P>.05). However, some qualitative differences on histologic views were found. Conclusions : CMP-coating is suggested to be the preferred candidate for fast osseointegration over HAcoating.

  • PDF

Xanthan Gum으로 코팅된 Carbonyl Iron Particle를 이용한 자기유변유체 연마특성에 관한 연구 (Characteristics of MR Polishing using Carbonyl Iron Particles Coated with Xanthan Gum)

  • 이정원;하석재;신봉철;김동우;조명우;최형진
    • 소성∙가공
    • /
    • 제21권2호
    • /
    • pp.138-143
    • /
    • 2012
  • A polishing method using magnetorheological (MR) fluid has been developed as a new precision technique to obtain a fine surface. The process uses a MR fluid that consists of magnetic carbonyl iron (CI) particles, nonmagnetic polishing abrasives, water and stabilizers. But the CI particles in MR fluids cause a severe corrosion problem. When coated with Xanthan gum, the CI particles showed long-term stability in corrosive aqueous environment. The surface roughness obtained from the MR polishing process was evaluated. A series of experiments were performed on fused silica glass using prepared slurries and various process conditions, including different polishing times. Outstanding surface roughness of Ra=2.27nm was obtained on the fused silica glass. The present polishing method could be used to produce ultra-precision micro parts.

SURFACE CHARACTERISTICS AND BIOLOGICAL RESPONSES OF HYDROXYAPATITE COATING ON TITANIUM BY HYDROTHERMAL METHOD: AN IN VITRO STUDY

  • Kim, Dong-Seok;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jun
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.363-378
    • /
    • 2005
  • Statement of problem. Hydroxyapatite(HA) coated titanium surfaces have not yet showed the reliable osseointegration in various conditions. Purpose. This study was aimed to investigate microstructures, chemical composition, and surface roughness of the surface coated by the hydrothermal method and to evaluate the effect of hydrothermal coating on the cell attachment, as well as cell proliferation. Material and Methods. Commercially pure(c.p.) titanium discs were used as substrates. The HA coating on c.p. titanium discs by hydrothermal method was performed in 0.12M HCl solution mixed with HA(group I) and 0.1M NaOH solution mixed with HA(group II). GroupⅠ was heated at 180 $^{\circ}C$ for 24, 48, and 72 hours. GroupⅡ was heated at 180 $^{\circ}C$ for 12, 24, and 36 hours. And the treated surfaces were evaluated by Scanning electron microscopy(SEM), Energy dispersive X-ray spectroscopy(EDS), X-ray photoelectron spectroscopy(XPS), X-ray diffraction method(XRD), Confocal laser scanning microscopy(CLSM). And SEM of fibroblast and 3-(4,5- dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide(MTT) assay were used for cellular responses of the treated surfaces. Results. The color of surface changed in both groups after the hydrothermal process. SEM images showed that coating pattern was homogeneous in group II, while inhomogeneous in group I. H72 had rosette-like precipitates. The crystalline structure grew gradually in group II, according to extending treatment period. The long needle-like crystals were prominent in N36. Calcium(Ca) and phosphorus(P) were not detected in H24 and H48 in EDS. In all specimens of group II and H72, Ca was found. Ca and P were identified in all treated groups through the analysis of XPS, but they were amorphous. Surface roughness did not increase in both groups after hydrothermal treatment. The values of surface roughness were not significantly different between groups I and II. According to the SEM images of fibroblasts, cell attachments were oriented and spread well in both treated groups, while they were not in the control group. However, no substantial amount of difference was found between groups I and II. Conclusions. In this study during the hydrothermal process procedure, coating characteristics, including the HA precipitates, crystal growth, and crystalline phases, were more satisfactory in NaOH treated group than in HCl treated group. Still, the biological responses of the modified surface by this method were not fully understood for the two tested groups did not differ significantly. Therefore, more continuous research on the relationship between the surface features and cellular responses seems to be in need.

Initial adhesion of bone marrow stromal cells to various bone graft substitutes

  • Jo, Young-Jae;Kim, Kyoung-Hwa;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Chung, Chong-Pyoung;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제41권2호
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: The aim of this study is to determine whether certain biomaterials have the potential to support cell attachment. After seeding bone marrow stromal cells onto the biomaterials, we investigated their responses to each material in vitro. Methods: Rat bone marrow derived stromal cells were used. The biomaterials were deproteinized bovine bone mineral (DBBM), DBBM coated with fibronectin (FN), synthetic hydroxyapatite (HA), HA coated with FN, HA coated with $\beta$-tricalcium phosphate (TCP), and pure $\beta$-TCP. With confocal laser scanning microscopy, actin filaments and vinculin were observed after 6, 12, and 24 hours of cell seeding. The morphological features of cells on each biomaterial were observed using scanning electron microscopy at day 1 and 7. Results: The cells on HA/FN and HA spread widely and showed better defined actin cytoskeletons than those on the other biomaterials. At the initial phase, FN seemed to have a favorable effect on cell adhesion. In DBBM, very few cells adhered to the surface. Conclusions: Within the limitations of this study, we can conclude that in contrast with DBBM not supporting cell attachment, HA provided a more favorable environment with respect to cell attachment.

성견 치주질환 이환 발치와에 즉시 임플란트 매식술시 Titanium plasma sprayed 임프란트와 Hydroxyapatite coated 임프란트의 계면조직에 관한 연구 (HISTOLOGICAL COMPARISONS OF TITANIUM PLASMA SPRAYED IMPLANT AND HYDROXYAPATITE COATED IMPLANT TO BONE INTERFACE IN PERIODONTALLY INVOLVED EXTRACTION SOCKETS IN DOGS)

  • 김진숙;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.400-410
    • /
    • 1993
  • Dental implants have been widely used in the treatment of esthetic and functional problems of the mouth due to alveolar bone loss, after tooth extraction. The success of implantation strongly depends on osseointegration. For osseointegration, implant material, methodology, and design have been investigated. For materials, two popular materials at present are titanium and hydroxyapatite. For methods, immediate implantation is being used recently. The purpose of this study is to evaluate osseointegration between the unthreaded cylindrical TPS implant and the HA-coated implant by a histomorphometric analysis. For this analysis, experimental periodontits was induced on the 3, 4 premolars of adult dogs by the ligation of orthodontic threads. Thereafter, each tooth was extracted. TPS. Implants and HA-coated implants were immediately inserted in the extraction socket. In control group, TPS implants were immediately inserted, and In experimental group, HA implants were immediately inserted. The dogs were sacrificed after 12 weeks, then the specimens were prepared for LM and histomorphometric analysis. The conclusion of this study is as follows l. In both control and experimental group, no inflammatory cells were observed. 2. The results of the histomorphometric analysis showed that the total osseointegration was 48.5% in control group, and 68.8% in expermental group. The experimental group was higher than the control group, and the difference was not statistically significant (p<0.05). 3. The results of the histomorphometric analysis showed that the osseointegration in the hole was 40.6% in control group, and 70.2% in experimental group. The experimental group was higher than the control group, and the difference was statistically significant (p<0.05). In both control and experinental group, no inflammatory cells were observed. 4. The results of the histomorphometric analysis showed that the osseointegration in the lower part was 52.1% in control group, and 73.3% in experimental group. The experimental group was higher than the control group, and the difference was statistically significant (p<0.05). 5. In experimental group, the bone to HA interface seemed to be mixed of bone and HA. We could not distinguish HA from the bone. The HA coating was detached from the titanium surface.

  • PDF