• Title/Summary/Keyword: HA기기

Search Result 417, Processing Time 0.026 seconds

Development of a Scalable Clustering A/V Server for the Internet Personal-Live Broadcasting (인터넷 개인 생방송을 위한 Scalable Clustering A/V Server 개발)

  • Lee, Sang-Moon;Kang, Sin-Jun;Min, Byung-Seok;Kim, Hag-Bae;Park, Jin-Bae
    • The KIPS Transactions:PartC
    • /
    • v.9C no.1
    • /
    • pp.107-114
    • /
    • 2002
  • In these days, rapid advances of the computer system and the high speed network have made the multimedia services popularized among various applications and services in the internet. Internet live broadcasting, a part of multimedia services, makes it possible to provide not only existing broadcasting services including audio and video but also interactive communications which also expand application scopes by freeing from both temporal and spatial limitation. In the Paper, an interned Personal-live broadcasting server system is developed by allowing individual users to actively create or join live-broadcasting services with such basic multimedia devices as a PC camera and a sound card. As the number of broadcasters and participants increases, concurrent multiple channels are established and groups are to be expanded. The system should also guarantee High Availability (HA) for continuous services even in the presence of partial failure of the cluster. Furthermore, a transmission mode switching is supported to consider network environments in the user system.

The Research Relating to QA of the Absorbed Dose in the 10 MeV E-beam Facility in Accordance with the International Standards (국제표준에 따른 10 MeV급 전자빔 조사시설의 흡수선량 품질보증에 관한 연구)

  • Ha, Tae-Sung;Ahn, Cheol;Jung, Pyeong-Hwan;Cho, Jeong-Hee;Lee, Jong-Seok;Lee, Hye-Nam;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • In the field of healthcare, the conventional sterilization treatments have been replaced by irradiation methods which are in accordance with internationally well established quality standards. The quality control in radiation sterilization assures that the absorbed dose of the irradiated material is in agreement with its requirements and standards. The electron beam irradiation requires technical assessments of more process parameters than gamma irradiation does. Korea has witnessed wide uses of electron accelerators since early 2000 but there hasn't been research experiences relating to quality system in accordance with international standards. The new large scale e-beam irradiation system with the specification of 10 MeV, 8 kW was installed and operated in 2008 by Seoul Radiology Services Co. It consists of the electron accelerator, product handling system, safety, documentation and control subsystems into an integrated system to meet the requirement of the Good Manufacturing Practice such as process quality assurance and management of product tracking records. To implement the international standard such as EN ISO11137, it is necessary to understand the purposes aimed in the standard and carry out the tests following the procedures required. This study presented the specification of the e-beam facility and showed what its design requirements and features are. The test results on a variety of process parameters were presented and validated it they are within the required limits.

A study on necessity of education and safety awareness to high school students when accessing laboratories (고등학생들의 연구실 이용에 따른 안전 인식 및 교육 필요성에 관한 연구)

  • Choi, Seo-Yeon;Lee, Ha-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.139-146
    • /
    • 2016
  • The purpose of this study is to investigate the necessity of safety awareness and education regarding the use of laboratories, and to foster safety awareness during intramural and extracurricular activities in high schools. The study conducted a questionnaire to 290 eleventh grade students of three high schools located in Seoul. The collected data were statistically analyzed. The result illustrates that 64.8% of students have experienced safety education during a regular class, 6.6% have experienced accidents, and 68.0% have experienced safety education during field activities. The result concludes that there is a lack of prior safety education as well as overall low awareness on the necessity of safety education. In particular, students who have experienced safety education recognizes the necessity of emergency education regarding laboratory accident more than those who did not receive such education. Thus, a systematic management of laboratory safety education and multilateral management measures for students' safety are required. There is a relatively high correlation between safety intention of R&D and Education factors and Community and Laboratory Safety Education. As much as there is a high safety demand regarding the laboratory instruments and experiment, it shows high intention of safety lab operation as well as count measurement of lab accident. This study recommends developing a laboratory safety education program and management methods appropriate for high school students.

A Study on the Minimum Ignition Limit Voltages for LPG-Air Mixtures by Discharge Sparks in Radio-frequency Circuits (고주파 전기회로의 개폐불꽃에 의한 LPG-공기 혼합가스의 최소점화한계전압에 관한 연구)

  • Lee Chun-ha;Kim Jae-ouk;Jee Sung-ouk;Song Hun-jik;Lee Gang-sik;Lee Dong-in
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.79-84
    • /
    • 1998
  • This paper describes the minimum ignition limit voltages for LPG-Air 5.25[Vol$\%$] mixture gas by discharge sparks in radio-frequency limits using RF power supply and IEC type ignition spark apparatus. As a result, the minimum ignition limit voltages is increased in proportional to the rate of increasing of frequency in LPG-Air mixture gas. Especially, the minimum ignition limit voltages increase remarkably between 3[KHz] and 10[KHz]. It is considered that ignition is caused by one discharge until 3[KHz] and, beyond 3[KHz] ignitiof is caused by more than two discharges. The reason is analyzed that energy loss is caused by existing pause interval between discharges. It is considered that the result can be used for not only data for researches and development of intrinsically safe explosion-proof RF machines which are applied tole-equipments and detectors used in dangerous areas but also for datum for its equipment tests.

  • PDF

A DC-DC Converter Design for OLED Display Module (OLED Display Module용 DC-DC 변환기 설계)

  • Lee, Tae-Yeong;Park, Jeong-Hun;Kim, Jeong-Hoon;Kim, Tae-Hoon;Vu, Cao Tuan;Kim, Jeong-Ho;Ban, Hyeong-Jin;Yang, Gweon;Kim, Hyoung-Gon;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.517-526
    • /
    • 2008
  • A one-chip DC-DC converter circuit for OLED(Organic Light-Emitting Diode) display module of automotive clusters is newly proposed. OLED panel driving voltage circuit, which is a charge-pump type, has improved characteristics in miniaturization, low cost and EMI(Electro-Magnetic Interference) compared with DC-DC converter of PWM(Pulse Width Modulator) type. By using bulk-potential biasing circuit, charge loss due to parasitic PNP BJT formed in charge pumping, is prevented. In addition, the current dissipation in start-up circuit of band-gap reference voltage generator is reduced by 42% and the layout area of ring oscillator is reduced by using a logic voltage VLP in ring oscillator circuit using VDD supply voltage. The driving current of VDD, OLED driving voltage, is over 40mA, which is required in OLED panels. The test chip is being manufactured using $0.25{\mu}m$ high-voltage process and the layout area is $477{\mu}m{\times}653{\mu}m$.

Comparison among Gamma(${\gamma}$) Line Systems for Non-Linear Gamma Curve (비선형 감마 커브를 위한 감마 라인 시스템의 비교)

  • Jang, Won-Woo;Lee, Sung-Mok;Ha, Joo-Young;Kim, Joo-Hyun;Kim, Sang-Choon;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.265-272
    • /
    • 2007
  • This proposed gamma (${\gamma}$) correction system is developed to reduce the difference between non-linear gamma curve produced by a typical formula and result produced by the proposed algorithm. In order to reduce the difference, the proposed system is using the Least Squares Polynomial which is calculating the best fitting polynomial through a set of points which is sampled. Each system is consisting of continuous several kinds of equations and having their own overlap sections to get more precise. Based on the algorithm verified by MATLAB, the proposed systems are implemented by using Verilog-HDL. This paper will compare the previous algorithm of gamma system such as Existing system with Seed Table with the latest that such as Proposed system. The former and the latter system have 1, 2 clock latency; each 1 result per clock. Because each of the error range (LSB) is $1{\sim}+1,\;0{\sim}+36$, we can how that Proposed system is improved. Under the condition of SAMSUNG STD90 0.35 worst case, each gate count is 2,063, 2,564 gates and each maximum data arrival time is 29.05[ns], 17.52[ns], respectively.

A Study on the Uniform Mixing of Ammonia-Air with the Change of Ammonia Supply Device Shape in a De-NOx System (탈질설비에서 암모니아 혼합기의 형상에 따른 암모니아-공기 균일 혼합에 관한 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.20-26
    • /
    • 2019
  • Selective catalytic reduction(SCR) method is widely used among various methods for reducing nitrogen oxides in combustion devices of coal power plant. In the present study, the computational fluid dynamic analysis was accomplished to derive the optimal shape of ammonia-dilution air mixing device in a ammonia injection grid. The distribution characteristics of flow and $NH_3$ concentration had been elucidated for the reference shape of ammonia mixing device(Case 1). In the mixing device of Case 1, it could be seen that $NH_3$ distribution was shifted to the wall opposite to the inlet of the ammonia injection pipe. For the improvement of $NH_3$ distribution, the case(Case 2) with closing one upper injection hole and 4 side injection holes, the case(Case 3) with installing horizontal plate at the upper of ammonia injection pipe, the case(Case 4) with installing horizontal plate and horizontal arc plate at he upper of ammonia injection pipe were investigated by analyzing flow and $NH_3$ concentration distributions. From the present study, it was found that the % RMS of $NH_3$ for Case 4 was 4.92%, which was the smallest value among four cases, and the range of $R_{NH3}$ also has the optimally uniform distribution, -10.82~8.34%.

Investigation of the Molecular Diagnostic Market in Animals (동물 분자 진단 시장의 동향)

  • Park, Chang-Eun;Park, Sung-Ha
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.26-33
    • /
    • 2019
  • Recently, the rapid growth of the companion animal market has led to the development of animal disease diagnosis kits. Therefore, the utility of the introduction of biomarkers for the development of animal molecular diagnostics is being reevaluated. A good biomarker should be precise and reliable, distinguish between normal and diseased states, and differentiate between different diseases. Recently reported genetic markers, tumor markers (cell free DNA, circulating tumor cells, granzyme, and skin tumors), and others (brucellosis, programmed death recovery-1, symmetric dimethylarginine, periostin, and cysteinyl leukotrien) have been developed. The biomarkers are used for risk prediction or for the screening, diagnosis, and monitoring of disease progression. The most important criteria for related biomarkers are disease specificity. Many potential biomarkers have emerged from laboratory and test studies, but they have not been validated in independent or large-scale clinical studies. Candidate biomarkers evaluate disease associations, verify the effectiveness of biomarkers for early detection and disease progression, and incorporate them into humans and animals. In the future, it will be necessary to reevaluate the utility of well-structured biomarker-based research and study the development of kits that can be used in on-site tests in accordance with the trends introduced in the diagnosis of animal diseases.

A Study on the Flow Characteristics of the Flue Gas Recirculation with the Change of Venturi Tube Shape (벤튜리관 형상에 따른 배기가스 재순환 유동 특성에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hun;Kim, Dae Yeon
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.12-18
    • /
    • 2019
  • Exhaust gas recirculation method is widely used among various methods for reducing nitrogen oxides in automobile engines and incinerators. In the present study, the computational fluid dynamic analysis was accomplished to derive the optimal location of air nozzle exit position by changing its position in a venturi tube for the maximum flue gas recirculation effect. In addition, the flue gas recirculation characteristics with a cone at the exit of air nozzle was elucidated with flue gas recirculation flow rate ratio and mixed gas exit temperature. When the air nozzle exit position was changed from the start position (z = 0) to the end position (z = 0.6m) of the exhaust gas recirculation exit pipe, the change of streamline and temperature distribution in the venturi tube was observed. The exhaust gas recirculation flow rate and the average temperature at the mixed gas exit position was quantitatively compared. From the present study, the optimal location of air nozzle exit position for the maximum flue gas recirculation flow rate ratio and maximum mixed gas exit temperature is z = 0.15m (1/4L). In addition, when the cone is installed at the outlet of the air nozzle, the velocity of the air nozzle outlet is increased, the flue gas recirculation flow rate was increased by about 2 times of the flow rate without cone, and the mixed gas exit temperature is increased by $116^{\circ}C$.

The Effects of Using Consumers' Risk Perception and Service Quality on the Intention of Repurchase in the Rental Service (렌탈 서비스 이용고객의 위험지각 및 서비스품질이 재이용의도에 미치는 영향)

  • Ha, Gyu-Soo;JUN, Seo-Hoon
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.569-584
    • /
    • 2022
  • This study can be helpful in establishing and establishing company-wide marketing strategies from the supplier's point of view by analyzing the effects of rental service users' risk perception and service quality on customers' re-use intentions, and revealing differences according to demographic characteristics. It was intended to provide valid results. A total of 218 data were used as analysis data. Frequency, factor, mean, reliability and regression analysis, ANOVA, and t-test were performed through SPSS program (statistics). As a result of the study, first, as a result of analyzing the effect of risk perception on rental service quality, functional and psychological risks have a negative (-) effect on service quality. Second, in the relationship between service quality and re-use intention, the empathy factor has a high positive (+) effect, and as a result of analyzing the effect of risk perception on re-use intention, functional and psychological risk have the greatest influence, and financial Risk perception was also highly influential. In conclusion, the research results suggest that increasing the concentration of marketing strategies by reducing the negative (-) effect related to risk perception for short-term customers and housewives and enhancing the reliability and empathy for service quality can maximize the sales of suppliers.