• Title/Summary/Keyword: H2S sensing

Search Result 212, Processing Time 0.027 seconds

The Washing Effect of Precipitation on PM10 in the Atmosphere and Rainwater Quality Based on Rainfall Intensity (강우 강도에 따른 대기 중 미세먼지 저감효과와 강우수질 특성 연구)

  • Park, Hyemin;Byun, Myounghwa;Kim, Taeyong;Kim, Jae-Jin;Ryu, Jong-Sik;Yang, Minjune;Choi, Wonsik
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_3
    • /
    • pp.1669-1679
    • /
    • 2020
  • This study examines the washing effect of precipitation on particulate matter (PM) and the rainwater quality (pH, electrical conductivity (EC), water-soluble ions concentration). Of six rain events in total, rainwater samples were continuously collected every 50 mL from the beginning of the precipitation using rainwater collecting devices at Pukyong National University, Busan, South Korea, from March 2020 to July 2020. The collected rainwater samples were analyzed for pH, EC, and water-soluble ions (cations: Na+, Mg2+, K+, Ca2+, NH4+, and anions: Cl-, NO3-, SO42-). The concentrations of particulate matter were continuously measured during precipitation events with a custom-built PM sensor node. For initial rainwater samples, the average pH and EC were approximately 4.3 and 81.9 μS/cm, and the major ionic components consisted of NO3- (5.4 mg/L), Ca2+ (4.2 mg/L), Cl- (4.1 mg/L). In all rainfall events, rainwater pH gradually increased with rainfall duration, whereas EC gradually decreased due to the washing effect. When the rainfall intensities were relatively weak (<5 mm/h), PM10 reduction efficiencies were less than 40%. When the rainfall intensities were enhanced to more than 7.5 mm/h, the reduction efficiencies reached more than 60%. For heavy rainfall events, the acidity and EC, as well as ions concentrations of initial rainwater samples, were higher than those in later samples. This appears to be related to the washing effect of precipitation on PM10 in the atmosphere.

SAR Measurements of Surface Displacements at Augustine Volcano, Alaska, Associated with the 1986 and 2006 Eruption

  • Lee, C.W.;Jung, H.S.;Won, J.S.;Lu, Z.;Kwoun, O.I.
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.401-404
    • /
    • 2007
  • Augustine volcano is an active stratovolcano located at the southwest of Anchorage, Alaska. Augustine volcano had experienced seven significantly explosive eruptions in 1812, 1883, 1908, 1935, 1963, 1976, and 1986, and a minor eruption in January 2006. We measured the surface displacements of the volcano by radar interferometry and GPS before and after the eruption in 2006. ERS-1/2, RADARSAT-1 and ENVISAT SAR data were used for the study. Multiple interferograms were stacked to reduce artifacts caused by different atmospheric conditions. Least square (LS) method was used to reduce atmospheric artifacts. Singular value decomposition (SVD) method was applied for retrieval of time sequential deformations. The observed surface displacements from satellite radar interferometry were compared with GPS data. Satellite radar interferometry helps to understand the surface displacements system of Augustine volcano.

  • PDF

Development of Rock Slope Survey and Analysis System using GIS

  • Park, H. J.;Chang, B. S.;Lee, S.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.144-146
    • /
    • 2003
  • Techniques for rock slope management and assessment must be developed for the prevention and mitigation of rock fall hazards. To enable this, the rock discontinuity such as fault and joint data must be surveyed, analysed and managed. For this, the discontinuities were detected by automatic and semi-automatic method using DEM and ortho-rectified image of rock slope and the rock slope analysis and management system was developed using GIS. Using the system, slope locations and discontinuities data were constructed to spatial database. The system is consist of ‘Data Management’, ‘Rock Slope DB’, ‘Basic Information’, ‘Image Processing’, ‘Image Analys ing’, ‘Edit’, ‘View’, ‘Theme’, ‘Graphic’, ‘Window’ and ‘Help’. The system was developed using avenue of ArcView 3.2.

  • PDF

Analysis of soil erosion hazard zone using GIS

  • Kim J. H.;Kim K.T.;Park J. S.;Choi Y.S.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.664-667
    • /
    • 2004
  • This paper is aimed at analyzing the soil erosion hazard zone in farm land. RUSLE was used for an analysis of soil erosion amount, and for the spatial data of basin, soil erosion amount was calculated by extracting the respect topography space related factors of RUSLE using DEM, Landuse, Soil map as base map. As a result of analysis on the calculated soil erosion amount according to land use type, it was analyzed that the most soil erosion occurred in orchard area, i.e., 40.08ton/ha/yr at average. It was classified into 5 classes depending on the calculated soil erosion amount. of which Class V was decided as soil erosion hazard zone, and for this area, 72.5ha or so, $2.4\%$ of the entire farm land was assessed as erosion hazard zone.

  • PDF

Study on Angular Rate Sensor using Sol-Gel PZT thin film (Sol-gel 압전체 박막을 이용한 각속도 센서에 대한 연구)

  • Lee, S. H.;R. Meada;M. Esashi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.34-34
    • /
    • 2003
  • Piezoelectric or magnetostrictive materials, known as smart materials, have been researched widely for sensors or actuators in micro system technology. In our research, thick sol-gel lead zirconate titanate(Pb(Zr$\sub$1-x/Ti$\sub$x/)O$_3$) films were fabricated and their characteristics were investigated f3r angular rate sensor applications. The thickness of the PZT films is 1.5${\mu}$m, which is required by a vibration angular rate sensor for a good actuation and sensing. The remnant polarization of the PZT flms is 12.0 ${\mu}$C/$\textrm{cm}^2$. The electromechanical constants of PZT thin film showed the value of susceptance(B) of 4800${\mu}$ s at capacitance of 790pF. The PZT films were applied to the vibration angular rate sensor structure and the vibration of 1.78 ${\mu}$m in amplitude at the resonant frequency of 35.8㎑ was obtained by driving voltage of 5V$\sub$p-p/ of bulk piezoelectric materials with out of phase signal through voltage and inverting amplifier.

  • PDF

A Non-enzymatic Hydrogen Peroxide Sensor Based on CuO Nanoparticles/polyaniline on Flexible CNT Fiber Electrode (CuO Nanoparticles/polyaniline/CNT fiber 유연 전극 기반의 H2O2 검출용 비효소적 전기화학 센서)

  • Min-Jung Song
    • Korean Chemical Engineering Research
    • /
    • v.61 no.2
    • /
    • pp.196-201
    • /
    • 2023
  • In this study, a CNT fiber flexible electrode grafted with CuO nanoparticles (CuO NPs) and polyaniline (PANI) was developed and applied to a nonenzymatic electrochemical sensor for H2O2 detection. CuO NPs/PANI/CNT fiber electrode was fabricated through the synthesis and deposition of PANI and CuO NPs on the CNT fiber surface using an electrochemical method. Surface morphology and elemental composition of the CuO NPs/PANI/CNT fiber electrode were characterized by scanning electron microscope with energy dispersive X-ray spectrometry. And its electrochemical characteristics were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA). Compared with a bare CNT fiber as a control group, the CuO NPs/PANI/CNT fiber electrode showed a 4.78-fold increase in effective surface area and a 8.33-fold decrease in electron transfer resistance, which leads to excellent electrochemical properties such as a good electrical conductivity and an efficient electron transfer. These improved characteristics were due to the synergistic effect through the grafting of CNT fiber, PANI and CuO NPs. As a result, this electrode enhanced the H2O2 sensing performance.

A Study on the Development of Noninvasive Tissue-Reflectance Oximeter (Noninvasive Tissue-Reflectance Oximeter의 개발에 관한 연구)

  • Chang, S.Y.;Kim, N.J.;Koo, C.H.;Lee, J.K.;Lim, H.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.420-423
    • /
    • 1997
  • The oxygen saturation of blood can be measured by sensing the difference absorption in optical spectra of Hb and $HbO_2$, as the well known previous study. [1] In this study we developed the noninvasive tissue reflectance oximeter(TRO) using three kinds of LEDs which produce a peak spectral emission at a wavelength of 565, 660 and 940nm. And we tested the unction of the TR oximeter by comparing the output signals measured on normal tissue to measured on low oxygenated tissue. The results showed that oxygen saturation of blood and biological tissue can be monitored from the separation arrangement light source and detector.

  • PDF

Study of a Recurring Anticyclonic Eddy off Wonsan Coast in Northern Korea Using Satellite Tracking Drifter, Satellite Ocean Color and Sea Surface Temperature Imagery (위성원격탐사를 이용한 동해 원산연안의 재발생 와동류 연구)

  • 서영상;장이현;김정희
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.3
    • /
    • pp.211-220
    • /
    • 2000
  • Even though recurring eddies at the terminal end of the East Korean Warm Current have been identified in the thermal infrared imagery from the NOAA/AVHRR sensor and ocean color data from Orbview-2/SeaWiFS sensor, it is difficult to make observation in the field regarding recurring eddies located around the Wonsan coastal area in North Korea. But we could get in situ data related to an eddy from an ARGOS satellite tracking drifter trapped in the eddy on January 4th, 1999. An ARGOS drifter, a NOAA satellite tracked buoy was trapped by the eddy during January 4th.March 18, 1999. The ARGOS drifter rotated 10 times per 72 days on the edge of the eddy located at $39^{\circ}N$, $129^{\circ}E$. The diameter of the eddy was about 100 km. The horizontal rotation velocity of the recurring cold-core anti-cyclonic eddy was 1.53 km/h(42 cm/sec). The sea surface temperatures of the eddy varied from $14.7^{\circ}C$ on January 5, 1999 to $9.6^{\circ}C$ on March 18,1999. To study the mechanism of the recurring eddy. we tried to find out the relationship between the vector of the drifter moving in the eddy and the wind vector in Sokcho and Ulleung Island located near the eddy in southern Korea, and the difference in sea level between Ulleung Island and Mukho. We hope the results of this study would be useful for calibration and validation data of simulation and numerical modeling studies of the recurring eddy.

후속열처리 공정을 이용한 FD Strained-SOI 1T-DRAM 소자의 동작특성 개선에 관한 연구

  • Kim, Min-Su;O, Jun-Seok;Jeong, Jong-Wan;Jo, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.35-35
    • /
    • 2009
  • Capacitorless one transistor dynamic random access memory (1T-DRAM) cells were fabricated on the fully depleted strained-silicon-on-insulator (FD sSOI) and the effects of silicon back interface state on buried oxide (BOX) layer on the memory properties were evaluated. As a result, the fabricated 1T-DRAM cells showed superior electrical characteristics and a large sensing current margin (${\Delta}I_s$) between "1" state and "0" state. The back interface of SOI based capacitorless 1T-DRAM memory cell plays an important role on the memory performance. As the back interface properties were degraded by increase rapid thermal annealing (RTA) process, the performance of 1T-DRAM was also degraded. On the other hand, the properties of back interface and the performance of 1T-DRAM were considerably improved by post RTA annealing process at $450^{\circ}C$ for 30 min in a 2% $H_2/N_2$ ambient.

  • PDF

Spatially filtered multi-field responses of piezothermoelastic cylindrical shell composites

  • Tzou, H.S.;Bao, Y.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.2
    • /
    • pp.111-124
    • /
    • 1996
  • New active "intelligent" structural systems with integrated self-sensing, diagnosis, and control capabilities can lead to a new design dimension for the next generation high-performance structures and mechanical systems. However, temperature effects to the piezoelectric transducers are not fully understood. This paper is concerned with a mathematical modeling and analysis of a laminated piezothermoelastic cylindrical shell composite exposed to mechanical, electric, and thermal fields. Generic shell equations and solution procedures are derived. Contributions of spatial and time components in the mechanical, electric, and temperature excitations are discussed, and their analytical solutions derived. A laminated cylindrical shell composite with fully distributed piezoelectric layers is used in a case study; its multi-field step and impulse responses are investigated. Analyses suggest that the fully distributed actuators are insensitive to even modes due to load averaging and cancellation. Accordingly, these even modes are filtered from the total response and only the modes that are combinations of m = 1, 3, 5, ${\cdots}$ and n = 1, 3, 5, ${\cdots}$ participating in dynamic response of the shell.