• 제목/요약/키워드: H1*-H2* measure

Search Result 809, Processing Time 0.03 seconds

Study on the Filter Collection Methods of Ammonia and Ammonium Salts in the Atomosphere (대기중의 암모니아 및 암모늄염의 필터포집법에 관한 연구)

  • Hui Kang Kim;橋本芳一;Yong Keun Lee
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.36-42
    • /
    • 1982
  • Filters were evaluated to use in the collection of ammonia and ammonium salts in the atmosphere. Ammonia from standard gas generator was collected on a glass fiber filter impregnated with a mixture of 3% boric acid and 25% glycerin. The collection efficiency by the impregnated filter was 96.4${\pm}$2.15% in pH control method and 97.4${\pm}$1.06% in the atmosphere for five measurements, respectively. Adsorption and desorption of gaseous ammonia were compared using three commercially available filters; glass fiber, quartz fiber and polycarbonate filters. Both glass and quartz fiber filters indicated some loss of ammonium salts and adsorption of ammonia, respectively. However, polycarbonate filter was found to be satisfactory for the collection of ammonium salts in the atmosphere. The minimum measurable concentration of ammonia was 0.83ppb (ca. 0.63${\mu}g$/$m^3$) by spectrophotometry of the indophenol method for the sample collected by 47mm${\phi}$ filter(20l/min, 60min). The sensitivity of the present method is about 20 folds higher than that of conventional method of bubbler collection followed by spectrophotometry, so that this method makes it possible to measure thevariation of ammoniacal concentrations in the atmosphere for a short time period of about 60 min.

  • PDF

The Effect of An Increase of Closed Quotient on Improvement of Voice Quality after Type I Thyroplasty in Patients with Unilateral Vocal Cord Paralysis (일측 성대마비 환자에서 성대내전술 후 성대접촉율의 증가가 음질 개선에 미치는 영향)

  • Kim, Han-Su;Choi, Seung-Hee;Lim, Jae-Yol;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.16-20
    • /
    • 2004
  • Purpose : To assess perceptual, acoustic and aerodynamic measure of voice quality in patients with unilateral vocal cord paralysis before and after type I thyroplasty. Methods : The clinical records of patients operated type I thyroplasty in the Departement of otorhinoalryngolgy, Yongdong Severance hospital from November 2001 to November 2003 were reviewed. All patients uderwent a vocal function evaluation including perceptual, acoustic and aerodynamic measures of voice preoperative and on $60^{th}$ postoperative day. The perceptual and acoustic measures were obtained from recording of patients' reading a 'Sanchak' passage. The perceptual evaluation was performed by 2 speech pathologist using a 4-point rating scale. Acoustic parameters(voice range profile low(RAL), voice range profile high(RAH), average fundamental frequency(AFX), closed quotient, harmonic to noise ratio, jitter and shimmer) were investigated by Lx speech studio. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured using the Phonatory function analyzer. The maximum phonation time was also measured. The data were statistically analyzed. A paired t-test (p<0.1) was used to compare preoperative and postoperative results. And multiple regression test was used to find which parameter was most correlated to improvement of postoperative voice quality. Results : Among aerodynamic parameters, Psub $(88.11mmH_2O{\rightarrow}58.7mmH_2O)$, MPT(7.87sec${\rightarrow}$12.53sec), MFR (359.8ml/sec${\rightarrow}$161.06ml/sec) were statistically improved. AFx(205.5Hz${\rightarrow}$163.27Hz), AQx(23.9%${\rightarrow}$48.3%), RAL, RAH. Jotter and shimmer were improved. In multiple regression test, AFx and AQx was noted as the two meost correlated parameters to improvement of postoperative breathiness. But general grade of voice quality was more correlated to Psub and shimmer. Conclusion : Vocal fold medialization procedures effectively reduce glottic gap. Increasing of contact area of both vocal folds induced improvement in aerodynamic parameters and leaded stabilizing of vocal fold vibration. That effect results in improvement in acoustic parameters (shimmer, jitter, signal-to-noise ratio, voice range profile) and voice quality.

  • PDF

Effect of Paeonia Lactiflora Pallas on Atopic Dermatitis-Related Inflammation in HaCaT Cell (작약이 HaCaT 세포에서 아토피 피부염 관련 염증 억제에 미치는 영향)

  • Lee, Hye-In;Kim, Eom Ji;Son, Dongbin;Joo, Byung Duk;Sohn, Youngjoo;Kim, Eun-Young;Jung, Hyuk-Sang
    • Korean Journal of Acupuncture
    • /
    • v.39 no.2
    • /
    • pp.43-53
    • /
    • 2022
  • Objectives : Paeonia lactiflora Pallas (PLP) have been reported to have pharmacological effects such as anti-inflammatory and analgesic. However, it is not yet known whether PLP extract has anti-inflammatory effect on HaCaT cells, human keratinocyte. Methods : To confirm the anti-inflammatory effect of PLP on keratinocyte, TNF-𝛼/IFN-𝛾-stimulated HaCaT cells were used. HaCaT cells were pre-treated with PLP for 1h before stimulation with TNF-𝛼/IFN-𝛾. Then HaCaT cells were stimulated with TNF-𝛼/IFN-𝛾 for 24 h, the cells and media were harvested to measure the inflammatory cytokines levels. Granulocyte-macrophage colony stimulating factor (GM-CSF), monocyte chemoattractant protein-1 (MCP-1), interleukin 1 beta (IL-1𝛽), and TNF-𝛼 were analyzed by enzyme-linked immunosorbent assay (ELISA), and the mRNA expression of thymus and activation-regulated chemokines (TARC), IL-6, and IL-8 were measured by reverse transcription-polymerase chain reaction (RT-PCR). We also investigated the inhibitory mechanism of the mitogen-activated protein kinase (MAPKs) including ERK, JNK, and p38 and nuclear factor-kappaB (NF-𝜅B) by PLP using western blot. Results : PLP did not show cytotoxicity in HaCaT cells. In TNF-𝛼/IFN-𝛾-stimulated HaCaT cells, PLP significantly inhibited the expression of GM-CSF, MCP-1 IL-1𝛽, TNF-𝛼, TARC and IL-6. PLP inhibited the phosphorylation of ERK and translocation of NF-𝜅B into the nucleus. Conclusions : These results indicate that PLP could ameliorate the TNF-𝛼/IFN-𝛾-stimulated inflammatory response through inhibition of MAPK and NF-kB signal pathway. This suggests that PLP could be used beneficial agent to improve skin inflammation.

Process of Change, Self Efficacy and Decisional Balance Corresponding to Stage of Change in Smoking Cessation in Industrial Workers (산업장 남성근로자의 금연변화단계별 변화과정, 자기효능감과 의사결정 균형에 관한 연구)

  • Lee, Yun-Mi;Park, Nam-Hee;Seo, Ji-Min
    • Korean Journal of Adult Nursing
    • /
    • v.15 no.3
    • /
    • pp.483-492
    • /
    • 2003
  • Purpose: The study was performed to identify the process of change, decisional balance and self-efficacy corresponding to the stage of smoking cessation behavior based on Transtheoretical Model in industrial workers. Method: A convenience sample of 146 industrial workers except for the never smokers, were recruited at a H industry in Ulsan. Data were collected from February 1 to 28, 2002. The research instruments were Stages of Change of Smoking Cessation Measure(DiClemente et al, 1991), Process of change(Prochaska, 1988), Smoking Abstinence Self Efficacy (SASE: DiClemente et al, 1985) and Decisional balance(SDB; Kim, 1999). Result: The results of this study were as follows; 1. The subjects were distributed in each stage of smoking cessation change: There were 64 subjects (43.0%) in the precontemplation stage, 35 subjects(23.5%) in the contemplation stage, 28 subjects(18.8%) in the preparation stage, 14 subjects(10.1%) in the action stage and 7 subjects(4.7%) in the maintenance stage. 2. Analysis of variance showed that experiental process(F=2.808, p=.042), behavioral process (F=4.567, p=.004) self-efficacy(F=9.809, p=.000), pros(F=11.107, p=.000), cons(F=6.686, p=.000), pros- cons(F=3.446, p=.018) were significantly associated with the stages of smoking cessation change. 3. Through discriminant analysis, it was found that 'PROS' was the most influential variable in discriminating the four stages of change. Conclusion: This study can provide the basis of staged matching smoking cessation program using TTM for more effective and useful intervention.

  • PDF

The Study on the Level of Air Pollution at Four Department Stores in Pusan Area (부산지역 4개 백화점의 공기오염도에 관한 조사연구)

  • Moon, D.H.;Rhee, HW.;Lee, C.U.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.164-180
    • /
    • 1991
  • For the purpose of contributing to the promotion of health of the employees working at the same kind of department store or similar type of business and the people utilizing them and preparing the basic data for the establishment of mangagement measure by assessing the level of air pollusion at indoor and outodoor of four department store among the distribution service business in Pusan area, authors measured the concentration of sulfur dioxide, nitrogen dioxide, formaldehyde and total suspanded particle according to the measuring height of variable at indoor and outodoor from Aug. 1990. to sep. an. d Jan, 1991 to Feb.: for each two months in summer and winter, and studied by dividing the variable factor into atmospheric factor (temperature, humidity and air velociy) The results are as follows ; 1. The mean concentration of air pollutants at indoor to total subjects was nitrogen dioxide 31.1ppb, sulfur dioxide 51.7ppb, formaldehyde 162.lppb and total suspanded particle $67.7{\mu}g/m^3$, and it was higher in winter than in summer (P>0.05) 2. The mean concentration of formaldehyde to total subjects was higher indoors than outdoors (P<0.001), in case of nitrogen dioxide there was no significant difference and sulfur dioxide and total suspanded particle were higher outdoors than indoors (P<0.05) 3. The concentration of nitrogen dioxide and sulfur dioxide proved to be a adverse correlation, reducing with height. 4. According to the result questioned about the exposure concentration of pollutant and the general symptom caused by the pollutant, nitorgen dioxide and symptom proved to be a positive correlation (P<0.09).

  • PDF

Theoretical construction of solar wind proton temperature anisotropy versus beta inverse correlation

  • Seough, Jungjoon;Yoon, Peter H.;Kim, Khan-Hyuk;Lee, Dong-Hun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.118.1-118.1
    • /
    • 2012
  • In situ observations from the Wind spacecraft that statistically analyzed the solar wind proton at 1 AU has indicated that the measured proton temperature anisotropies seems to be regulated by the oblique instabilities (the mirror and oblique firehose). This result is in contradiction with the prediction of linear kinetic theory that the ion-cyclotron (for ${\beta}_{\parallel}$ < 2) and parallel firehose (for ${\beta}_{\parallel}$ <10) would dominate over the oblique instabilities. Various kinds of physical mechanisms have been suggested to explain this disagreement between the observations and linear theory. All of the suggestions consider the solar wind as a unoform magnetized plasma. However the real space environment is replete with the intermediate spatio-temporal scale variations associated with various physical quantities, such as the magnetic field intensity and the solar wind density. In this paper we present that the pervasive intermediate-scale temporal variation of the local magnetic field intensity can lead to the modification of the proton temperature anisotropy versus beta inverse correlation for temperature-anisotropy-driven instabilities. By means of quasilinear kinetic theory involving such temporal variation, we construct the simulated solar wind proton data distribution associated the magnetic fluctuations in (${\beta}_{\parallel}$, $T_{\perp}/T_{\parallel}$) space. It is shown that the theoretically simulated proton distribution and a general trend of the enhanced fluctuations bounded by the oblique instabilities are consistent with in situ observations. Furthermore, the measure magnetic compressibility can be accounted for by the magnetic spectral signatures of the unstable modes.

  • PDF

THE 3.3 ㎛ PAH FEATURE AS A SFR INDICATOR: PROBING THE INTERPLAY BETWEEN SF AND AGN ACTIVITIES

  • Kim, Ji Hoon;Im, M.;Kim, D.;Woo, J.H.;Park, D.;Imanishi, M.;AMUSES Team, AMUSES Team;LQSONG Team, LQSONG Team
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.281-284
    • /
    • 2012
  • We utilize AKARI's slitless spectroscopic capability to detect the $3.3{\mu}m$ polycyclic aromatic hydrocarbons (PAHs) emission and measure star formation (SF) activity for various AKARI programs. First, we obtain $2{\sim}5{\mu}m$ spectra of 20 flux-limited galaxies with mixed SED classes in order to calibrate the $3.3{\mu}m$ PAH luminosity ($L_{PAH3.3}$) as a star formation rate (SFR) indicator. We find that $L_{PAH3.3}$ correlates with $L_{IR}$ as well as with the $6.2{\mu}m$ PAH luminosity ($L_{PAH6.2}$). The correlations does not depend on SED classes. We find that ULIRGs deviate from the correlation between PAH luminosities and $L_{IR}$, while they do not for the correlation between PAH luminosities. We suggest possible effects to cause this deviation. On the other hand, how AGN activity is linked to SB activity is one of the most intriguing questions. While it is suggested that AGN luminosity of quasars correlates with starburst (SB) luminosity, it is still unclear how AGN activity is connected to SF activity based on host galaxy properties. We are measuring SFRs for the LQSONG sample consisting of reverberation mapped AGNs and PG-QSOs. This is an extension of the ASCSG program by which we investigated the connection between SB and AGN activities for Seyferts type 1s at z ~ 0.36. While we found no strong correlation between $L_{PAH3.3}$ and AGN luminosity for these Seyferts 1s, $L_{PAH3.3}$ measured from the central part of galaxies correlates with AGN luminosity, implying that SB and AGN activities are directly connected in the nuclear region.

Bond Strength Evaluation of Asphalt Emulsions used in Asphalt Surface Treatments (아스팔트포장의 표면처리에 사용되는 유화아스팔트의 접착력 특성 평가)

  • Im, Jeong Hyuk;Kim, Y. Richard;Yang, Sung Lin
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.1-8
    • /
    • 2014
  • PURPOSES : The objective of this study is to evaluate the bond strength of asphalt emulsions including polymer-modified emulsions for chip seals and fog seals using the bitumen bond strength (BBS) test. METHODS : For the laboratory testing, the Pneumatic Adhesion tensile Testing Instrument(PATTI) device is used to measure the bond strength between the asphalt emulsion and aggregate substrate based on the AASHTO TP-91. In order to conduct all the tests in controled condition, all test procedures are performed in the environmental chamber. The CRS-2L and the SBS CRS-2P emulsions are used as a polymer-modified emulsion, and then unmodified emulsion, the CRS-2, is compared for the evaluation of chip seal performance. For the fog seal performance evaluation, two types of polymer-modified emulsions and one of unmodified emulsion, the CSS-1H, are employed. For chip seal study, the BBS tests are performed at 30, 60, 120, and 240 minutes of curing times with curing and testing temperatures of $15^{\circ}C$, $25^{\circ}C$, and $35^{\circ}C$. The fog seal tests are conducted at 30, 60, 90, 120, 180 minutes, and 24 hours with curing and testing temperatures of $25^{\circ}C$, $30^{\circ}C$, and $35^{\circ}C$. RESULTS AND CONCLUSIONS : Overall, chip seal emulsions and fog seal emulsions show the similar bond strength trend. At the same testing condition, polymer-modified emulsions show better bond strength than unmodified emulsions. Also, there is no significant difference between polymer-modified emulsions. One of important findings is that the most bond strength reaches their final bond strength within one hour of curing time. Therefore, the early curing time plays a vital role in the performance of chip seals and fog seals.

A Comparison Study of Heat Loss Characteristics in Monofilament and Multifilament Superconducting Coils Driven with AC Currents (단일필라멘트와 다중필라멘트 초전도 코일의 교류 전류에 의한 발열 특성 비교 평가)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.111-116
    • /
    • 2011
  • Since superconducting wires have no resistance, electromagnets based on the superconducting wires produce no resistive heating with DC current as long as the current does not exceed the critical current of the wire. However, unlike resistive wires, superconducting wires exhibit AC heat loss. Embedding fine superconducting filaments inside copper matrix can reduce this AC loss to an acceptable level and opens the way to AC-capable superconducting coils. Here, we introduce an easy and accurate method to measure AC heat loss from sample superconducting coils by measuring changes in the rate of gas helium outflow from the liquid helium dewar in which the sample coil is placed. This method provides accurate information on total heat loss of a superconducting coil without any size limit, as long as the coil can fit inside the liquid helium dewar. With this method, we have evaluated AC heat loss of two superconducting solenoids, a 180-turn solid NbTi wire with 0.127 mm diameter (NbTi coil) and a 100-turn filamented wire with 1.4 mm diameter where 7 NbTi filaments were embedded in a copper matrix with copper to NbTi ratio of 6.7:1 (NbTi-Cu coil). Both coils were wound on 15 mm-diameter G-10 epoxy tubes. The AC heat losses of the NbTi and NbTi-Cu coils were evaluated as $53{\pm}4.7\;{\mu}W/A^2Hzcm^3$ and $0.67{\pm}0.16\;{\mu}W/A^2Hzcm^3$, respectively.

The Concentrations of PCBs in the Serum and Theri Predictors of Exposure n Korean Women (일부 한국 성인 여성들의 혈중 PCBs 농도 및 그 노출요인의 연구)

  • 민선영;정문호;이강숙;노영만;구정환
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.2
    • /
    • pp.97-107
    • /
    • 2000
  • PCBs [Polychlorinated biphenyls] are halogenated aromatic compounds with the empirical formula C12H10-nCln(n=1~10), and are a mixture of possible 209 different chlorinated congeners. PCBs were widely used as dielectric fluids for capacitors, transformers, plasticizers, lubricant inks, and paint additives. once released into the environment, PCBs persist for years because they are so resistant to degradation. In addition to their high degree of lipophilicity. In 1970s, the worldwide production of PCBs seem to be still in use. The environmental load of PCBs was prohibited since 1983 in Korea. In spite of these actions, many PCBs seem to be still in use. The environmental load of PCBs will continue to be recycled through air, land, water, and the biosphere for decades to come. This study was conducted to measure the concentrations of PCBs I the serum samples of 112 women by GC/MSD(Hewlett Packard 5897 Gas Chromatography-Mass Chromatography Detector) and CG/ECD(Hewlett Packard 5890 series-II gas chromatography-Electron capture detector, U.S.A). The main results of this study were as follows; The mean and standard deviation of serum PCBs were 3.613, 0.759 ppb, respectively and median of it was 3.828 ppb. The correlation coefficients of the concentrations of 13 PCB congeners ranged from 0.7913 to 0..9985 and were significantly correlated between each items(p=0.0001). The PCB concentrations were positively associated with age(simple linear regression; R2=0.86, =0.08023, p<0.001) and with total lipids in serums(simple linear regression; R=0.7058, =0.00486, p<0.001). The age adjusted model (Y=$\beta$0+$\beta$1age+$\beta$2X) was applied for possible predictors of PCBs levels in serum. For BMI(Body Mass Index), major residential area, and fish, meat, and dairy consumption, there was no association with PCBs levels, Also there was negative association for the number of pregnancy and lactation period with PCBs levels.

  • PDF