• Title/Summary/Keyword: H1*-H2* measure

Search Result 809, Processing Time 0.031 seconds

Statistics of two-point correlation and network topology for Ly α emitters at z ≈ 2.67

  • Sungryong Hong;Arjun Dey;Kyoung-Soo Lee;Alvaro A Orsi;Karl Gebhardt;Mark Vogelsberger;Lars Hernquist;Rui Xue;Intae Jung;Steven L Finklestein;Sarah Tuttle;Michael Boylan-Kolchin
    • Monthly Notices of the Royal Astronomical Society
    • /
    • v.483 no.3
    • /
    • pp.3950-3970
    • /
    • 2019
  • We investigate the spatial distribution of Ly α-emitting galaxies (LAEs) at z ≈ 2.67, selected from the NOAO Deep Wide-Field Survey, using two-point statistics and topological diagnostics adopted from network science. We measure the clustering length, r0 ≈ 4 h-1 Mpc, and the bias, bLAE = 2.2+0.2-0.1. Fitting the clustering with halo occupation distribution (HOD) models results in two disparate possibilities: (1) where the fraction of central galaxies is <1 per cent in haloes of mass >1012 M and (2) where the fraction is ≈20 per cent. We refer to these two scenarios as the 'Dusty Core Scenario' for Model#1, since most of the central galaxies in massive haloes are dead in Ly α emission, and the 'Pristine Core Scenario' for Model#2, since the central galaxies are bright in Ly α emission. Traditional two-point statistics cannot distinguish between these disparate models given the current data sets. To overcome this degeneracy, we generate mock catalogues for each HOD model using a high-resolution N-body simulation and adopt a network statistics approach, which provides excellent topological diagnostics for galaxy point distributions. We find three topological anomalies from the spatial distribution of observed LAEs, which are not reproduced by the HOD mocks. We find that Model#2 matches better all network statistics than Model#1, suggesting that the central galaxies in >1012 h-1 M haloes at z ≈ 2.67 need to be less dusty to be bright as LAEs, potentially implying some replenishing channels of pristine gas such as the cold mode accretion.

Feature Analysis of Different In Vitro Antioxidant Capacity Assays and Their Application to Fruit and Vegetable Samples (In Vitro 항산화능 측정법에 대한 특징 분석과 채소.과일 시료에 대한 적용 사례 고찰)

  • Kim, Min-Jung;Park, Eun-Ju
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.7
    • /
    • pp.1053-1062
    • /
    • 2011
  • Reactive oxygen species (ROS), including singlet oxygen (${O_2}^1$), superoxide anion radical ($O_2{\cdot}^-$), hydroxyl radical ($HO{\cdot}$), peroxyl radical ($ROO{\cdot}$), hydrogen peroxide ($H_2O_2$), and hypochlorous (HOCl), are generated as byproducts of normal cellular metabolism. ROS induce damage to many biological molecules, such as lipids, proteins, carbohydrates, and DNA. It is widely believed that some degenerative diseases caused by ROS can be prevented by the high intake of fruits and vegetables due to their antioxidant activities. Recently, research on natural antioxidants has become increasingly active in various fields. Several assays have been developed to measure the total antioxidant capacity of antioxidants in fruits and vegetables in vitro. These assays include those for DPPH radical scavenging activity, SOD-like activity, total polyphenol content, oxygen radical absorbance capacity, reducing power, trolox equivalent antioxidant capacity (ABTS assay), single-cell gel electrophoresis (comet assay), and a cellular antioxidant activity assay. Because different antioxidant compounds may act through different mechanisms in vitro, no single assay can fully evaluate the total antioxidant capacity of foods. Due to the complexity of the composition of foods, it is important to be able to measure antioxidant activity using biologically relevant assays. In this review, recently used assays were selected for extended discussion, including a comparison of the advantages and disadvantages of each assay and their application to fruits and vegetables.

Gamma-ray Exposure Rate Monitoring by Energy Spectra of NaI(Tl) Scintillation detectors

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.3
    • /
    • pp.158-165
    • /
    • 2017
  • Background: Nuclear facilities in South Korea have generally adopted pressurized ion chambers to measure ambient gamma ray exposure rates for monitoring the impact of radiation on the surrounding environment. The rates assessed with pressurized ion chambers do not distinguish between natural and man-made radiation, so a further step is needed to identify the cause of abnormal variation. In contrast, using NaI(Tl) scintillation detectors to detect gamma energy rates can allow an immediate assessment of the cause of variation through an analysis of the energy spectra. Against this backdrop, this study was conducted to propose a more effective way to monitor ambient gamma exposure rates. Materials and Methods: The following methods were used to analyze gamma energy spectra measured from January to November 2016 with NaI detectors installed at the Korea Atomic Energy Research Institute (KAERI) dormitory and Hanbat University. 1) Correlations of the variation of rates measured at the two locations were determined. 2) The dates, intervals, duration, and weather conditions were identified when rates increased by $5nSv{\cdot}h^{-1}$ or more. 3) Differences in the NaI spectra on normal days and days where rates spiked by $5nSv{\cdot}h^{-1}$ or more were studied. 4) An algorithm was derived for automatically calculating the net variation of the rates. Results and Discussion: The rates measured at KAERI and Hanbat University, located 12 kilometers apart, did not show a strong correlation (coefficient of determination = 0.577). Time gaps between spikes in the rates and rainfall were factors that affected the correlation. The weather conditions on days where rates went up by $5nSv{\cdot}h^{-1}$ or more featured rainfall, snowfall, or overcast, as well as an increase in peaks of the gamma rays emitted from the radon decay products of $^{214}Pb$ and $^{214}Bi$ in the spectrum. This study assumed that $^{214}Pb$ and $^{214}Bi$ exist at a radioactive equilibrium, since both have relatively short half-lives of under 30 minutes. Provided that this assumption is true and that the gamma peaks of the 352 keV and 1,764 keV gamma rays emitted from the radionuclides have proportional count rates, no man-made radiation should be present between the two energy levels. This study proved that this assumption was true by demonstrating a linear correlation between the count rates of these two gamma peaks. In conclusion, if the count rates of these two peaks detected in the gamma energy spectrum at a certain time maintain the ratio measured at a normal time, such variation can be confirmed to be caused by natural radiation. Conclusion: This study confirmed that both $^{214}Pb$ and $^{214}Bi$ have relatively short half-lives of under 30 minutes, thereby existing in a radioactive equilibrium in the atmosphere. If the gamma peaks of the 352 keV and 1,764 keV gamma rays emitted from these radionuclides have proportional count rates, no man-made radiation should exist between the two energy levels.

Development of Two-color Radiation Thermometer for Harsh Environments

  • Mohammed, Mohammed Ali Alshaikh;Kim, Ki-Seong
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.184-194
    • /
    • 2016
  • Many industrial processes require reliable temperature measurements in harsh environments with high temperature, dust, humidity, and pressure. However, commercially-available conventional temperature measurement devices are not suitable for use in such conditions. This study thus proposes a reliable, durable two-color radiation thermometer (RT) for harsh environments that was developed by selecting the appropriate components, designing a suitable mechanical structure, and compensating environmental factors such as absorption by particles and gases. The two-color RT has a simple, compactly-designed probe with a well-structured data acquisition system combined with efficient LabVIEW-based code. As a result, the RT can measure the temperature in real time, ranging from 300 to $900^{\circ}C$ in extremely harsh environments, such as that above the burden zone of a blast furnace. The error in the temperature measurements taken with the proposed two-color RT compared to that obtained using K-type thermocouple readouts was within 6.1 to $1.4^{\circ}C$ at a temperature range from 200 to $700^{\circ}C$. The effects of absorption by gases including $CO_2$, CO and $H_2O$ and the scattering by fine particles were calculated to find the transmittance of the two wavelength bands of operation through the path between the measured burden surface and the two-color probe. This method is applied to determine the transmittance of the short and long wavelength bands to be 0.31 and 0.51, respectively. Accordingly, the signals that were measured were corrected, and the true burden surface temperature was calculated. The proposed two-color RT and the correction method can be applied to measure temperatures in harsh environments where light-absorbing gases and scattering particles exist and optical components can be contaminated.

The effect of low level laser irradiation on proliferation and alkaline phosphatase activity of human gingival fibroblast in vitro (저출력 레이저 조사가 치은섬유아세포의 증식과 염기성 인산분해효소의 활성에 미치는 영향)

  • Park, Byung-Ki;Lim, Kee-Jung;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.715-724
    • /
    • 1996
  • This study was performed to identify the proliferation and to measure the alteration of alkaline phosphatase activity in human gingival fibroblasts cultured. For the present study, the authors cultured the human gingival fibroblasts oriented from the sound interdental gingiva, and used third passage. It was used methyl $[^3H]$ Thymidine to identify the proliferation in human gingival fibroblasts and used 410nm of the spectrophotometer to measure the alteration of the alkaline phosphatase activity in human gingival fibroblasts. The results were as follows: 1. There was a statistically significant increase in the proliferation of gingival fibroblasts following low level laser irradiation at 24 hour(p<0.05). 2. There was a statistically significant increase in activity of alkaline phosphatase compared to control group at 5-day laser irradiation after in laser irradiation groups(p<0.05). And there was a statistically significant increase in activity of alkaline phosphatase compared to control group at 7-day laser irradiation after in the I-minute laser irradiation group(p<0.05), but there was a statistically significant decrease in activity of alkaline phosphatase compared to 1minute laser irradiation group at 7-day laser irradiation in the 2-minute laser irradiation group after(p<0.05). The results, within the limits of the present experiments, suggest that, the low level laser irradiation accelerates the proliferation of gingival fibroblasts and alters the alkaline phosphatase activity until the restricted period.

  • PDF

A Study on the Algorithm for Detection of Partial Discharge in GIS Using the Wavelet Transform

  • J.S. Kang;S.M. Yeo;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.4
    • /
    • pp.214-221
    • /
    • 2003
  • In view of the fact that gas insulated switchgear (GIS) is an important piece of equipment in a substation, it is highly desirable to continuously monitor the state of equipment by measuring the partial discharge (PD) activity in a GIS, as PD is a symptom of an insulation weakness/breakdown. However, since the PD signal is relatively weak and the external noise makes detection of the PD signal difficult, it therefore requires careful attention in its detection. In this paper, the algorithm for detection of PD in the GIS using the wavelet transform (WT) is proposed. The WT provides a direct quantitative measure of the spectral content and dynamic spectrum in the time-frequency domain. The most appropriate mother wavelet for this application is the Daubechies 4 (db4) wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, is very well suited to detecting high frequency signals of very short duration, such as those associated with the PD phenomenon. The proposed algorithm is based on utilizing the absolute sum value of coefficients, which are a combination of D1 (Detail 1) and D2 (Detail 2) in multiresolution signal decomposition (MSD) based on WT after noise elimination and normalization.

Health Condition and Satisfaction of Elderly People Living in Free Welfare Facilities (무료시설 노인의 건강상태와 생활만족도)

  • Kim, Yoen-Kyoung;Park, Kyung-Min
    • Journal of Korean Academy of Rural Health Nursing
    • /
    • v.2 no.1
    • /
    • pp.5-13
    • /
    • 2007
  • Purpose: This study focused on the health conditions and satisfaction in day-to-day life of elders using welfare facilities where there is no charge, and thus provides basic data for development of quality services required for health enhancement and a variety of demands from these elders. Method: The participants in the study were 140 elders selected at random from facilities for elders in Taegu. The tools for the study were the Korean Health Status Measure for the Elderly (Shin, H. C., 2002), and Yoon's "Criteria of Older Adults Life Satisfaction"(1982). Results: Differences in life satisfaction were found according to general characteristics of the elders, and that a lack of caretaker professionalism and relationships with other elders, but not the program were scored lower. In the correlation between health status and life satisfaction, it was found that emotional, social function and physical pain showed correlations with life satisfaction. Conclusion: It is necessary for the enhancement of health status of these elders and improvement in life satisfaction that a variety of nursing interventions be implemented.

A study on velocity profiles and inlet length of developing transitional pulsating flows in the entrance region of a square duct (정4각 덕트 입구영역에서 천이파동유동의 속도분포와 입구길이에 관한 연구)

  • 유영태;모양유;홍성삼
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.92-104
    • /
    • 1993
  • In the present study, the velocity profiles and entrance length of developing transitional pulsating flows are investigated both analytically and experimentally in the entrance region of a square duct. The systems of conservation equations for transitional pulsating flows in a square duct are solved analytically by linearizing the non-linear convective terms. Analytical solutions are obtained in the form of infinite series for velocity pofiles. The experimental study for the air flow in a square duct(40mm*40mm*4000mm) is carried out to measure velocity profiles and other parameters by using a hot-wire anemometer with a data acquisition and processing system. The distribution of velocity profiles( $u_{ps}$ / $u_{m,ta}$) in the decelerating period is higher than in the accelerating period. The distribution of the axial component of the axial component of velocity in the transitional flow is nearly uniform in the central region of the duct, and decrease rapidly near the wall. The entrance length correlation of the transitional pulsating flows in a square duct is obtained to be $L_{e}$/ $D_{h}$=0.83 $A_{1}$R $e_{ta}$ /(.omega. sup+1)$^{2}$TEX>

  • PDF

Technology of Fuel cell stack fault detection by THDA (전고조파 왜율 분석을 통한 연료전지 스택 고장진단 기술)

  • Kim, UckSoo;Park, HyunSeok;Kang, SunDoo;Eom, JeongYong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.90.1-90.1
    • /
    • 2011
  • This technology is applicable to Electrical vehicle that using Energy from Hydrogen Fueled Cell. Electricity & water is got from chemical reaction between H2 & O2 in stack. This technology is used when fault diagnosis of Fuel cell is needed. It is General method that measure each cell's voltage of stack for fault diagnosis. but, this technology is method of measuring entire voltage of stack. For this reason, fault diagnosis system is simplified and cost of system is lower than previous one. In normal stack condition, characteristic graph of voltage-current has linearity. In fault stack condition, it has non-linearity. we use this characteristic to diagnosis of stack fault. In this technology, Specific frequency current is injected into stack & Stack voltage is measured in response. After that, stack voltage difference is analyzed to diagnosis of stack fault. Presently, Development of current injection module & basic program of THDA is finished. in future we will develop the technology of precise measurement technology about entire stack voltage.

  • PDF

Effect of nutrient composition in a mixed meal on the postprandial glycemic response in healthy people: a preliminary study

  • Kim, Jiyoung S.;Nam, Kisun;Chung, Sang-Jin
    • Nutrition Research and Practice
    • /
    • v.13 no.2
    • /
    • pp.126-133
    • /
    • 2019
  • BACKGROUND/OBJECTIVES: The glycemic index (GI) is a measure of the postprandial glucose response (PPGR) to food items, and glycemic load (GL) is a measure of the PPGR to the diet. For those who need to maintain a healthy diet, it is beneficial to regulate appropriate levels of blood glucose. In reality, what influences the meal GI or GL depends on the macronutrient composition and the physical chemistry reactions in vivo. Thus, we investigated whether different macronutrients in a meal significantly affect the PPGR and the validity of calculated GI and GL values for mixed meals. SUBJECTS/METHODS: 12 healthy subjects (6 male, 6 female) were recruited at a campus setting, and subjects consumed a total of 6 test meals one by one, each morning between 8:00 and 8:30 am after 12 h of fasting. PPGR was measured after each consumed meal and serial finger pricks were performed at indicated times. Test meals included 1) 68 g oral glucose, 2) 210 g rice, 3) rice plus 170 g egg white (RE), 4) rice plus 200 g bean sprouts (RS), 5) rice plus 10 g oil (RO), and 6) rice plus, egg white, bean sprouts, and oil (RESO). The incremental area under the curve (iAUC) was calculated to assess the PPGR. Mixed meal GI and GL values were calculated based on the nutrients the subjects consumed in each of the test meals. RESULTS: The iAUC for all meals containing two macronutrients (RS, RO, or RE) were not significantly different from the rice iAUC, whereas, the RESO iAUC ($2,237.5{\pm}264.9$) was significantly lower (P < 0.05). The RESO meal's calculated GI and GL values were different from the actual GI and GL values measured from the study subjects (P < 0.05). CONCLUSIONS: The mixed meal containing three macronutrients (RESO) decreased the PPGR in healthy individuals, leading to significantly lower actual GI and GL values than those derived by nutrient-based calculations. Thus, consuming various macronutrient containing meals is beneficial in regulating PPGR.